Square standard type, 非シールド, 直流3線式, NPN いいえ, 2メートルケーブル, classic model of TL-Q series
✅ モデルコードの説明
TL: 誘導的 近接センサー
Q: Square type (17×17mm)
5: 定格検出距離 5 mm
M: Built-in amplifier
C: NPN出力 (B = PNP)
1: 通常開 (いいえ) (2 = 通常閉, ノースカロライナ州)
Z: Revised suffix for domestic standard version
📌 主な仕様
センシング原理: Inductive type, for ferromagnetic metals (iron only); sensing distance drops sharply for copper, aluminum and other non-ferrous metals
検出距離: 5 mm ±10%; practical setting distance 0~4 mm
出力: NPNオープンコレクタ, 通常開 (いいえ)
電源電圧: DC10~30V (nominal DC12-24V)
負荷電流: マックス. 200 ミリアンペア
応答頻度: 500 Hz
Hysteresis distance: ≤10% of rated sensing distance
保護クラス: IP67
周囲温度: -25℃~+70℃ (no icing or condensation)
ハウジング: PBT/ABS, dimension 17×17×28 mm
ケーブル: Standard 2m lead wire
Built-in protection: 逆極性保護, surge absorption, load short-circuit protection
🧵 Wiring Definition (3-ワイヤー)
Brown wire: DC+ (パワーポジティブ)
Blue wire: 直流(0V)
Black wire: NPN出力 (PLCの入力端子に接続; one end of load to black wire, the other end to +24V)
When metal approaches → output turns ON, indicator light illuminates
📋 Cross-reference for the same series (for selection & 交換)
TL-Q5MC2-Z: NPN NC
TL-Q5MB1-Z: PNP いいえ
TL-Q5MB2-Z: PNP NC
TL-Q5MD1/2: DC 2-wire type
⚠️ Installation Notes (Critical for non-shielded type)
Non-shielded design. Do not mount tightly against metal. Keep sufficient clearance on side and rear surfaces, otherwise false triggering or reduced sensing distance will occur. Suitable for independent mounting to detect metal targets on front face.
🛠️ Typical Applications
Equipment limit detection, 数える, metal presence confirmation, conveyor positioning, machine tool fixture detection, compatible with digital inputs of Mitsubishi / シーメンス PLC.
🔁 Domestic Replacement Reference
Square 17×17mm, NPN いいえ, 非シールド, 5mm sensing proximity sensors from brands such as Hugong, オートニクス.
Wiring Diagram for TL-Q5MC1-Z (NPN いいえ)
Wiring rule: Brown = Positive, Blue = Negative, Black = Signal
茶色: DC+ 24V
青: DC0V
黒: NPN出力 (when iron approaches → black wire pulled to 0V, indicator ON)
This is non-shielded type. Side and rear surfaces cannot be close to metal to avoid false trigger.
1) Drive intermediate relay (independent load test)
Brown → 24V+
Blue → 24V-
Black → One terminal of relay coil
The other terminal of relay coil → 24V+
✅ Iron detected: Relay energized; No iron: Relay de-energized
2) Mitsubishi FX (sink input, 最も一般的な)
茶色: 24V+
青: 0V
黒: X0 (X input terminal)
PLC COM terminal: Connect to 24V+
Sink input: X point detects 0V signal → input LED ON, matching NPN output
3) Siemens S7-200SMART / S7-1200 (DI sink wiring)
茶色: 24V+
青: 0V
黒: I0.0 (DI terminal)
Input common terminal 1M: Connect to 24V+
注記: Siemens DI supports sink/source switching. NPN sensor requires 1M connected to +24V. If 1M is connected to 0V, it is for PNP sensors, this model cannot work.
4) オムロン CP1E/CP1H
茶色: 24V+
青: 0V
黒: Input terminal (例えば. 0.00)
COM: Connect to 24V+
⚠️重要: Sensor power supply and PLC power supply must share the same GND (0V connected together), otherwise signal jitter and unstable detection.
- Quick Multimeter Test Method (Test before power-on to avoid damage)
- 配線: Brown to 24V+, Blue to 0V, black wire open-circuit
- No iron nearby: Voltage on black wire ≈ 24V, indicator OFF
- Iron block close to front face (≤4mm): Voltage on black wire ≈ 0V, indicator ON
- Iron removed: Back to 24V, indicator OFF
If the performance is inconsistent → sensor damaged or wiring error
Ⅲ. Troubleshooting List for TL-Q5MC1-Z
| 現象 | Check Items |
| Indicator keeps ON all the time, cannot reset | ① Non-shielded installation: surrounding metal too close; ② Iron powder/chips on sensing surface; ③ Black wire shorted to 24V; ④ Internal transistor breakdown |
| Indicator always OFF, no response even with iron | ① Brown & Blue reversed, voltage lower than 10V; ② Insufficient power capacity; ③ Broken wire; ④ Sensor burnt; ⑤ Target is non-ferrous metal (aluminum/copper barely detectable) |
| Indicator ON but PLC receives no input | ① Wrong PLC COM wiring (NPN cannot use COM to 0V); ② No common GND; ③ Faulty input channel; ④ Long cable & interference; ⑤ Exceed 500Hz response frequency for high-speed counting |
| Signal intermittent / jumping randomly | ① Metal interference around non-shielded sensor; ② Signal cable routed together with power cables for inverter/servo; ③ Large ripple of power supply; ④ Working distance over 4mm; ⑤ Mutual interference between adjacent proximity sensors |
| Burned shortly after power-on | ① Long-term reverse connection (reverse protection exists but not for continuous reverse voltage); ② Load short-circuit; ③ Supply voltage over 30V |
- インストール & 配線仕様 (Non-shielded Priority)
- 検出距離: Practical working distance ≤4mm, avoid using the 5mm limit
- Mounting clearance: Keep ≥15mm clearance between sensor side/rear and metal. Shielded type can be flush mounted.
- Multi-sensor side-by-side installation: Center distance ≥30mm between two TL-Q sensors to prevent mutual interference
- ケーブル: Standard 2m; If extended, シールドケーブルを推奨します, shield grounded at single end; Do not run together with inverter / servo power cables
- Minimum iron target: Iron plate ≥17×17×1mm. Small workpiece causes unstable detection.
- Emergency Conversion Solution
If PLC only supports source input (COM connected to 0V) and only TL-Q5MC1-Z (NPN) 利用可能:
Use the NPN output to drive a DC24V miniature relay, then feed the relay dry contact to PLC input for signal isolation conversion.
Typical Application Cases of TL-Q5MC1-Z (NPN いいえ, 非シールド, 5mm)
Core constraints: Only detect ferromagnetic metal; reserve clearance from surrounding metal for non-shielded type; response frequency 500Hz; NPN いいえ, signal ON when metal approaches
場合 1: Workpiece arrival detection on conveyor line (最も広く使用されている)
Scene: Belt conveyor, tooling pallet assembly line, confirm iron/stainless steel workpiece arrives at station
解決: Sensor mounted at side of station, small iron sheet installed on pallet as target. When pallet arrives and iron sheet enters 0–4mm sensing zone, NPN signal sent to PLC input
論理: Signal ON → stop conveyor, start clamping / machining / marking; Signal OFF → release
注意事項:
Keep ≥15mm gap between conveyor frame metal and sensor side to avoid false trigger
アルミニウム / copper workpiece cannot be directly detected, add iron target plate
対応PLC: Mitsubishi FX, Siemens S7-200SMART (sink input)
場合 2: 起源 & hard limit for machine slide / manipulator
Scene: Small CNC equipment, servo slide, transfer manipulator origin homing and overtravel protection
解決: Iron target plate fixed on slide side, sensor installed at origin position. When slide returns home, trigger signal, PLC reset position and confirm origin completion. A second sensor can be used as overtravel limit.
アドバンテージ: 非接触, 機械的摩耗がない, better durability than mechanical limit switch under oil and iron chip environment
Risk reminder: Non-shielded type cannot attach to machine sheet metal, use bracket for floating installation. Iron chips accumulated on sensing surface will cause continuous false trigger, regular blow cleaning required.
場合 3: ギヤ / rotary table speed detection & pulse measurement
Scene: Indexing table, motor driven gear, rotary fixture, speed measurement, stall detection, 同期制御
解決: Ferromagnetic gear teeth aligned to sensor, pulse output when teeth pass by. PLC high-speed counter collects pulses to calculate rotation speed and stall status.
上限: マックス. 500Hz, suitable for low-speed rotary table (low RPM), not for high-speed spindle
試運転: Gap between tooth top and sensor controlled at 2–3mm; tooth width cannot be too small to guarantee stable pulse.
場合 4: Counting screws, nuts and stamping small parts
Scene: Vibratory feeder discharge, stamping blanking, hardware assembly machine, count ferrous parts
解決: Sensor mounted beside vibratory feeder track, trigger one pulse when screw passes sensing zone. PLC accumulates count, alarm or stop machine when reaching set value.
問題点: Repeated triggering for fast passing small parts; add debounce delay / single pulse latch in PLC program
制限: Only ferrous parts; weak magnetic stainless steel has reduced sensing distance, reduce gap accordingly.
場合 5: シリンダー / clamping fixture status feedback
Scene: Pneumatic clamping mechanism, fixture cylinder, confirm jaw clamping completion
解決: Iron target plate fixed at end of cylinder piston rod, sensor installed at cylinder tail. When cylinder extends to clamp, iron sheet approaches sensor and signal ON, PLC confirms clamping finished and allows next action.
比較: Better than cylinder magnetic switch — no risk of magnet demagnetization; 短所: Extra metal target plate needed.
場合 6: Low-level material alarm for ferrous bulk material silo
Scene: Iron powder, iron chips, steel ball silo, low material level alarm (lower limit detection)
解決: Sensor installed at lower side wall of silo. When material level higher than sensor, metal material covers sensing surface, signal ON; when material level drops below sensor, signal OFF, PLC triggers low material alarm for feeding reminder.
制限: Only for ferromagnetic bulk material; clean sensing surface regularly under heavy dust environment.
場合 7: Metal part presence confirmation & missing part check for packaging machine
Scene: Auto parts and hardware packaging machine, confirm iron gasket / iron clip is loaded
解決: Sensor fixed at station. When packaging is in place and target detected, 普通; no signal = missing part, trigger reject mechanism.
注意事項: Packaging machine frame has lots of metal, isolate sensor with bracket, cable shielding required, keep away from inverter power cables.
場合 8: 自動倉庫 & turnover pallet identification
Scene: Roller conveyor pallet positioning, iron sheet pre-installed on pallet bottom for station positioning and diverting
解決: Sensor mounted above or side of roller frame. When pallet flows to target station, iron sheet triggers signal, PLC stops roller and starts scanning or transfer action.
Multi-sensor mounting: Center distance ≥30mm between two TL-Q sensors to avoid mutual interference.
一般選抜 & Field Troubleshooting Summary for this Model
- 出力: NPN いいえ, cannot directly connect to PLC source input (COMから0Vへ); intermediate relay conversion required
- 取り付け: 非フラッシュ / 非シールド, do not mount against metal, ≥15mm clearance reserved for side and rear metal
- Target object: Standard target 17×17×1mm iron plate; sensing distance decreases for stainless steel / weak magnetic stainless steel; aluminum and copper barely detectable
- 環境: IP67, splash-proof and dust-proof, not for long-term immersion; suitable for machine tool, コンベア, stamping, packaging and light automation
- に適さない: Counting speed >500Hz, 長距離検出, aluminum/copper/plastic workpiece, flush mounting inside metal housing
- Complete Model List of TL-Q Series (17×17mm Square, 非シールド, DC24V)
Basic specs: 非フラッシュ (非シールド), 5検出距離mm, 500Hz応答周波数, DC10~30V, IP67; suffix -Z = standard 2m cable for domestic market; -F-Z = oil-resistant cable; -R = robot flexible cable; ending digit 5 = anti-interference frequency variant
1) DC 3-wire type (主流, TL-Q5MC / TL-Q5MB)
NPN出力 (C=NPN)
- TL-Q5MC1-Z: 通常開 (いいえ) (あなたのターゲットモデル)
- TL-Q5MC2-Z: 通常閉 (ノースカロライナ州)
- TL-Q5MC1-F-Z: Oil-resistant cable, NPN いいえ
- TL-Q5MC2-F-Z: Oil-resistant cable, NPN NC
- TL-Q5MC1-R: Robot flexible cable, NPN いいえ
- TL-Q5MC15: Different frequency anti-interference, NPN いいえ (for dense side-by-side installation)
PNP出力 (B=PNP)
- TL-Q5MB1-Z: 通常開 (いいえ)
- TL-Q5MB2-Z: 通常閉 (ノースカロライナ州)
- TL-Q5MB1-F-Z: Oil-resistant cable, PNP いいえ
- TL-Q5MB2-F-Z: Oil-resistant cable, PNP NC
- TL-Q5MB15: Different frequency anti-interference, PNP いいえ
2) DC 2-wire type (TL-Q5MD, non-polar 2-wire)
- TL-Q5MD1-Z: 通常開 (いいえ)
- TL-Q5MD2-Z: 通常閉 (ノースカロライナ州)
- TL-Q5MD15: Different frequency anti-interference, いいえ
- TL-Q5MD1-R: Flexible robot cable, 2-wire NO
3) Smaller variant of same series (2検出距離mm, 8×9mm)
TL-Q2MC1: NPN いいえ, DC3-wire, 2検出距離mm, no NC version.
- モデルコードの内訳 (TL-Q5M C 1 -Z)
TL-Q: Square non-shielded type
5: Sensing distance 5mm
M: Standard cable lead type
C: NPN; B: PNP; D: DC 2-wire
1: 通常開 (いいえ); 2: 通常閉 (ノースカロライナ州)
-Z: Domestic standard 2m cable; -F-Z: Oil-resistant; -R: High-flex cable; ending 5: anti-interference different frequency
Ⅲ. TL-N Series (Same outline, reference for larger sensing distance)
- TL-N5ME1/ME2: 25×25mm, 5mm, NPN
- TL-N7MD1/MD2: 7mm, DC 2-wire
- TL-N12MD: 12mm; TL-N20MD: 20mm
- Frequently Ordered Standard Models (2m標準ケーブル)
- NPN いいえ: TL-Q5MC1-Z (widely stocked)
- NPN NC: TL-Q5MC2-Z
- PNP いいえ: TL-Q5MB1-Z
- PNP NC: TL-Q5MB2-Z
- DC 2-wire NO: TL-Q5MD1-Z
- 追加の選択に関する注意事項
- All models are non-shielded (非フラッシュ), ≥15mm clearance required between side/rear and metal, cannot mount directly on sheet metal.
- Only for ferromagnetic metal; sensing distance reduced for stainless steel; aluminum and copper are almost undetectable.
- When multiple sensors are installed side by side, select models ending with 5 (different frequency) to avoid mutual interference.