Schneider TM5SPS2 Power Distribution Module

Modicon TM5 24VDC I/O Power Distribution Module (PDM) It belongs to Schneider TM5 distributed remote I/O series, compatible with M258 / LMC058 controllers. It supplies power to the TM5 backplane bus, and provides segmented 24V field power for I/O modules. It isolates different I/O power domains and expands backplane power capacity. ✅ Core Functions Power ...

  • 製品詳細

Modicon TM5 24VDC I/O 配電モジュール (PDM)

It belongs to シュナイダー TM5 distributed remote I/O series, compatible with M258 / LMC058 controllers. It supplies power to the TM5 backplane bus, and provides segmented 24V field power for I/O modules. It isolates different I/O power domains and expands backplane power capacity.

✅ Core Functions

  1. 電源 for TM5 internal power bus: マックス. output 1136mA (≤55℃); 740ミリアンペア (55~60℃)
  2. I/O field power segment: 24VDC, 最大. 10あ, to supply field side of DI/DO/AI/AO I/O modules on the right side of this base
  3. Segmented power isolation: A full TM5 station can be divided into multiple independent 24V I/O power domains. Short-circuit on one segment will not shut down the entire bus.
  4. Diagnostic status bits for bus: Bus OK / power warning, I/O data valid, readable via PLC program.

📋 Electrical Specifications

定格入力電圧: 24VDC, 動作範囲 20.4 ~ 28.8VDC

Max current of I/O power segment: 10あ. No built-in fuse; external Type T slow-blow fuse (max 10A/250V) is mandatory.

逆極性保護: 利用不可. Never reverse +24V and 0V wiring.

分離: 500Vac RMS isolation between TM5 bus circuit and I/O power segment

Max power dissipation: 1.91W, module self-consumption 25mA@24V

保護クラス: IP20 (キャビネット取り付けのみ)

寸法: W12.5mm × H99mm × D75mm, 重量約. 30g

Module ID code: 7104 (decimal)

Ambient operating temperature: -10 ~+55℃ (full current); derating from 55~60°C

🧩 Hardware & 構成

Compatible bus bases: TM5ACBM01R / TM5ACBM05R; Terminal block TM5ACTB12PS

取り付け: DINレール, slotted on TM5 bus base, mixed installation with TM5 I/O modules

ソフトウェア: マシンエキスパート (SoMachine). Module status word is available for reading bus power warning and network status.

⚠️ TM5SPS2 vs TM5SPS2F (Key Selection Guide)

TM5SPS2: External fuse required, max 10A for I/O segment

TM5SPS2F: Built-in 6.3A fuse, I/O segment limited to 6.3A, no external fuse needed

📌 Typical Applications

包装機械, マテリアルハンドリング, machine tool distributed remote I/O islands. Deploy TM5SPS2 for backplane power shortage or segmented protection for sensor/actuator power.

🛠️ Troubleshooting Guide

  1. Bus warning bit triggered: Check 24V voltage drop, ヒューズが切れた, overload or short circuit in I/O segment
  2. Module no communication: Verify TM5 bus connector, base address and module ID recognition
  3. No field power to I/O modules: Check external 24V input at PS2 terminals and external fuse status

注記: All 0V connections must be tied together and connected to Functional Earth (FE) to meet EMC requirements. Only PELV safety extra-low voltage power is permitted; mains AC voltage cannot be directly connected.

📎 Alternatives & シリーズ比較

TM5SPS1: I/O power segmentation only, no TM5 backplane bus power supply

TM5SPS2F: Same function with built-in 6.3A fuse

TM5SBER2: TM5 remote I/O receiver module with integrated bus power supply

Schneider TM5SPS2 Wiring Instructions

TM5SPS2 must be used with TM5ACTB12PS (12-pin spring terminal block). The terminal block snaps under the TM5ACBMxx bus base, and the electronic module plugs onto the base. Terminal numbers are printed on the terminal block.

  1. 端子の定義 (12-pin TM5ACTB12PS)
端子番号.信号名説明Fuse Requirement
1PS1 +24VTM5 backplane bus positive supply (feeds internal TM5 bus)Series Type T slow-blow 1A fuse (250V) upstream
2PS1 0VTM5 backplane bus negativeCommon ground with PS1 power supply
3ノースカロライナ州Not connected, no wiring allowed—
4ノースカロライナ州Not connected, no wiring allowed—
5PS2 +24VI/O field power segment positive (supplies all DI/DO/AI/AO I/O modules to the right of this module)Series Type T slow-blow fuse max.10A (250V) upstream
6PS2 0VI/O field power segment negativeCommon ground with PS2 power supply
7ノースカロライナ州Not connected—
8ノースカロライナ州Not connected—
9ノースカロライナ州Not connected—
10ノースカロライナ州Not connected—
11ノースカロライナ州Not connected—
12ノースカロライナ州Not connected—

✅ Quick distinction between two power rails:

PS1 (Pin1/2) = TM5 backplane bus power; PS2 (Pin5/6) = I/O field load power. Two separate 24V supplies can be used for isolated power segmentation.

  1. Two Typical Wiring Schemes

スキーム 1: Single 24V Power Supply (標準)

+24V from power supply is split into two branches: one through 1A T-fuse → Terminal 1; another through 10A T-fuse → Terminal 5

Power 0V: Tie Terminal 2 and Terminal 6 together, connect to power supply 0V. Link 0V to Functional Earth (FE) for EMC compliance.

注意事項: Bus power and I/O power share the same source. Short circuit on I/O side will not directly damage the bus, but the power supply capacity must cover both backplane and I/O loads.

スキーム 2: Two Independent 24V Supplies (Isolated Segmentation, 推奨)

PS1 (Pin1/2): Independent 24V supply with 1A slow-blow fuse, dedicated for TM5 backplane bus

PS2 (Pin5/6): Separate 24V supply with 10A slow-blow fuse for sensors and actuators of right-side I/O modules

The 0V of the two power supplies must be interconnected and connected to FE functional earth

アドバンテージ: Short circuit in I/O circuit will blow only the PS2 fuse, while TM5 backplane bus remains online. Suitable for high-reliability machines.

  1. ワイヤー仕様 (スプリング端子)

Wire gauge range: 0.08 ~ 2.5 mm², 推奨:

Main power cable: 0.75~1.5 mm²

Low-current signal: 0.5 mm²

Wire temperature rating ≥80°C, stripping length approx.8mm

  1. LED Indicator Definition (On Module Body)

E Fault LED:

Blinking: Low bus voltage / insufficient PS1 voltage / bus overload. Common field mistake: only PS2 (Pin5/6) wired while PS1 (Pin1/2) is missing → E LED blinks.

常時点灯: PS2 I/O power segment fault, 過負荷または短絡

RUN LED: 常時点灯: モジュールは正常です; オフ: No module power or bus fault

  1. Critical Safety & Wiring Prohibitions
  2. ❌ No built-in fuse! External Type T slow-blow fuse is mandatory for PS2 (max 10A). PS1 requires 1A slow-blow fuse. Module damage may occur without proper fusing in short-circuit events.
  3. ❌ No reverse polarity protection. Never swap +24V and 0V; reversed polarity will permanently damage TM5SPS2.
  4. ❌ Only PELV/SELV safety isolated 24VDC power supplies are allowed. Mains AC cannot be connected directly.
  5. ❌ Do not wire NC unused terminals (3,4,7~12) to prevent accidental short circuits.
  6. ✅ EMC mandatory requirement: All 0V tied together and connected to FE functional earth; FE shall not be confused with protective earth PE.
  7. ✅ Current derating: ≤55°C ambient for full backplane 1136mA; reduced to 740mA for 55~60°C.
  8. Pre-power-on Wiring Check List
  9. Confirm PS1 (Pin1,2) 24V is connected; do not only wire PS2 (Pin5,6)
  10. Verify Type T slow-blow fuses with correct ratings
  11. All 0V commoned and bonded to FE
  12. Terminals fully clamped, no loose connection or exposed copper strands causing short
  13. Measure before power-up with multimeter: 24VDC between pin1-2; 24VDC between pin5-6, correct polarity
  14. Configuration Notes (マシンエキスパート / SoMachine)

When the module is inserted into the base, software recognizes Module ID:7104. Status words available:

DcOk: Boolean flag for valid bus power

Bus power warning bit: Low voltage pre-alarm, usable for PLC alarm programming

Schneider Modicon TM5 Full Series Model List & Bill of Materials

互換性のあるコントローラー: M258 / LMC058 / LMC078; プログラミングソフトウェア: マシンエキスパート (以前は SoMachine)

System architecture: Bus base + electronic module + removable spring terminal block. SPS power distribution modules are core components for power segmentation.

  1. Power Distribution Modules (PDM, same series as TM5SPS2)
モデル説明主な特長互換性のあるベースCompatible Terminal Block
TM5SPS1I/O Power Segmentation ModuleSupplies 24V field power only to right-side I/O modules. No TM5 backplane bus power supply. No built-in fuse, max 10ATM5ACBM01R / 05RTM5ACTB12PS
TM5SPS1FI/O Power Segmentation with Built-in FuseI/O segment power only, built-in 6.3A fuse, no backplane power supplyTM5ACBM01R / 05RTM5ACTB12PS
TM5SPS2バックプレーンバス + I/O Dual Power SupplyPowers TM5 backplane bus and right-side I/O field power. No built-in fuse, I/O segment max 10ATM5ACBM01R / 05RTM5ACTB12PS
TM5SPS2FDual Power Module with Fuseバックプレーンバス + I/O segment power, replaceable built-in 6.3A fuseTM5ACBM01R / 05RTM5ACTB12PS
TM5SPS3IPDM Interface Power ModuleDedicated power module for Sercos III bus interfaceTM5ACBN1TM5ACTB12PS
  1. Bus Transceiver Modules (Remote Station Core)
モデル説明応用Compatible Terminal Block
TM5SBET1TM5 Bus TransmitterController-side bus transmitter, local start pointTM5ACTB12PS
TM5SBET7High-speed Bus TransmitterLong-distance high-speed transmissionTM5ACTB12PS
TM5SBER2TM5 Bus ReceiverRemote I/O island receiver with integrated backplane + I/O power supplyTM5ACTB12PS
  1. Bus Bases (Mechanical Base, modules plug onto bases)

Two base types: White straight-through bases, Grey isolated bases (for SPS power/transceiver modules)

|TM5ACBM11|White Bus Base|24V I/O power pass-through, no address rotary switch|Standard DI/DO/AI/AO modules|

|TM5ACBM15|White Bus Base|Power pass-through, with rotary address switch|Standard DI/DO/AI/AO modules|

|TM5ACBM01R|Grey Isolated Base|Isolates I/O power on left side, no address switch|SPS power modules, SBER2 receiver|

|TM5ACBM05R|Grey Isolated Base|Left I/O power isolation, with address rotary switch|SPS power modules, SBER2 receiver|

|TM5ACBN1|Sercos Dedicated Base|Sercos III bus special base, used with TM5SPS3|TM5NS31, TM5SPS3|

  1. Removable Spring Terminal Blocks (Must be ordered separately)
モデルピン色Applicable Module Types
TM5ACTB066-ピン白Small channel DI/DO/AI modules
TM5ACTB1212-ピン白General-purpose I/O modules
TM5ACTB12PS12-ピングレーSPS power modules, SBER2 receiver
TM5ACTB1616-ピン白High-density I/O
TM5ACTB3232-ピン白High-density I/O
  1. Digital Input Modules DI
モデルチャンネル仕様
TM5SDI2D2から24VDC sink, 3-ワイヤー
TM5SDI4D4から24VDC sink, 3-ワイヤー
TM5SDI6D6から24VDC sink, 2-ワイヤー
TM5SDI12D12から24VDC sink, 1-ワイヤー
TM5SDI16D16から24VDC sink, 高密度
TM5SDI2DF2から24VDC high-current input type
TM5SDI2A2からAC100~240V AC input
TM5SDI6U6からUniversal input
  1. Digital Output Modules DO
モデルチャンネル仕様
TM5SDO2T2する24V transistor output
TM5SDO4T4する24V transistor
TM5SDO4TA4するEnhanced transistor
TM5SDO6T6する24V transistor
TM5SDO8TA8するEnhanced transistor
TM5SDO12T12するトランジスタ
TM5SDO16T16するHigh-density transistor
TM5SDO2R / 4R2/4するRelay dry contact output
TM5SDO2S2するThyristor AC output
  1. Mixed I/O Modules DI+DO
モデルチャンネル説明
TM5SDM8DTS8DI+4DO24ワシントンDCで
TM5SDM12DT8DI+4DO12-point mixed I/O
TM5SMM6D2L6DI+2DOEconomical mixed module
  1. Analog Modules AI / へ
モデルチャンネル信号の種類
TM5SAI2L2AI4~20mAの電流
TM5SAI4L4AI4~20mA
TM5SAI8L8AI4~20mA
TM5SAI2V2AI±10V voltage
TM5SAO2L2へ4~20mA output
TM5SAO4L4へ4~20mA
TM5SAO2V2へ±10V voltage output
  1. High-speed Counter / エンコーダモジュール (SEシリーズ)
モデルチャンネルタイプ
TM5SE1IC025051 チャネル5V differential encoder
TM5SE1IC010241 チャネル24V single-ended encoder
TM5SE2IC010242 チャネル24V single-ended encoder
TM5SE1SC100051 チャネル5V single-ended encoder
  1. Communication Interface Modules
モデルインタフェースプロトコル
TM5PCRS2RS232Modbus RTU
TM5PCRS4RS485Modbus RTU
TM5PCDPSDPスレーブプロフィバス-DP
TM5NCO1CANopen SlaveCANopen
TM5NEIP1イーサネット/IPEtherNet/IP Remote I/O
TM5NS31Sercos IIISercos III motion bus
  1. 付属品
  2. TM5SD000: Dummy filler module for reserved slots
  3. TM5SPDG12F / TM5SPDD12F: 12-channel power distribution terminal module
  4. TM5SPDG5D4F: Multi-channel combined power distribution module

✅ TM5SPS2 Minimum Complete BOM for Purchase

  1. TM5SPS2 Power Distribution Electronic Module
  2. TM5ACBM01R Grey Isolated Base (no address) / TM5ACBM05R (with address rotary switch), select one
  3. TM5ACTB12PS Grey 12-pin spring terminal block (必須, separate order item)

Assembly rule: Insert SPS module into grey isolated base TM5ACBM01R/05R; snap TM5ACTB12PS terminal block underneath the base.

✅ Quick Selection Rules

  1. Standard DI/DO/AI/AO → White base TM5ACBM11/15 + white terminal block ACTB06/12
  2. SPS power segmentation, SBER2 receiver module → Grey isolated base + Grey ACTB12PS terminal block
  3. Insufficient backplane power, need segment protection → TM5SPS2; prefer built-in fuse for simpler wiring → TM5SPS2F
  4. Sensor power segmentation only, no requirement to boost backplane power → TM5SPS1 / TM5SPS1F

前へ: