Danfoss FC-302P55KT5E20H2BGXXXXSXXXXAXBXCXXXXDX Frequency Converter - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Danfoss FC-302P55KT5E20H2BGXXXXSXXXXAXBXCXXXXDX Frequency Converter - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

전기 같은/

Danfoss FC-302P55KT5E20H2BGXXXXSXXXXAXBXCXXXXDX Frequency Converter

VLT AutomationDrive FC-302 High-Performance General-Purpose Frequency Converter Order No.: 131F7151 Model Segment-by-Segment Decoding FC-302 P55K T5 E20 H2 B G XXXX SXXXX AXBXCXXXXDX Field Meaning Description FC‑302 Product Series VLT AutomationDrive FC‑302, with motion control, Safe‑Stop, supports servo‑type applications P55K Power Rating 55 kW / 75 HP T5 Power Supply Specification 3‑phase 380‑500 V AC E20 Ingress Protection ...

  • 제품 세부정보

VLT AutomationDrive FC-302 High-Performance General-Purpose Frequency Converter

주문번호: 131F7151

Model Segment-by-Segment Decoding

FC-302 P55K T5 E20 H2 B G XXXX SXXXX AXBXCXXXXDX

필드의미설명
FC‑302제품 시리즈VLT AutomationDrive FC‑302, with motion control, Safe‑Stop, supports servo‑type applications
P55K전력 등급55 kW / 75 HP
T5Power Supply Specification3‑phase 380‑500 V AC
E20유입 방지IP20 open‑frame, 캐비닛 마운트 설치
H2RFI FilterClass C3 industrial EMC filter (2nd environment, factory‑floor use)
Brake ChopperBuilt‑in brake chopper, brake resistor connectable
G조작 패널LCP102 graphical Chinese panel (표시하다 & 키패드)
XXXXPCB Coating / Power OptionX = Standard uncoated PCB, no extra power‑supply options
SXXXXSoftware RevisionLatest factory‑standard firmware version
도끼Option Slot ANo A‑slot communication card (slot A empty; 프로피네트, EtherNet‑IP etc. can be retrofitted)
BXOption Slot BNo B‑slot expansion card
CXOption Slot CNo C‑slot MCO motion‑control card
DXOption Slot DNo D‑slot option card

핵심 전기 사양

정격 출력: 55 kW

입력: 3-phase 380-500 V AC

Continuous output current: 106 에이

초과 적재: 160 % for 1 min (high-overload mode)

Chassis frame size: C4

On-board components: DC link reactor, brake chopper, Class C3 RFI filter

Standard protocol: 모드버스-RTU; no additional communication cards fitted

안전 기능: Safe-Stop hardware terminal

주변 온도: Full-rating at 40 °C; derate above up to max. 50 °C

Key Configuration Summary

✅ 55 kW, 380-500 다섯, IP20 open-frame

✅ Built-in brake chopper, compatible with brake resistor

✅ Equipped with LCP-102 graphical operator panel

✅ Class C3 industrial EMC filter, integrated DC-link reactor

❌ No Profinet / EtherNet-IP or other fieldbus cards; can be retrofitted via A/B slots

❌ No MCO motion-control card

일반적인 응용 분야

팬, 슬리퍼, 압출기, 컨베이어, 믹서, machine-tool spindles. Supports closed-loop vector, open-loop and servo modes; suitable for applications with regenerative braking energy.

Spare-part & Replacement Hints

  1. If brake chopper is not required: change B to X; order number will differ.
  2. For Profinet: fit option AL (MCA120); for EtherNet-IP: fit option AN (MCA121).
  3. Same power rating without panel: replace G with X, model becomes FC-302P55KT5E20H2BXXXXSXXXXAXBXCXXXXDX

FC-302P55KT5E20H2BGXXXXSXXXXAXBXCXXXXDX

55 kW / 380-500 V IP20, built-in brake chopper, 클래스 C3 EMC 필터, LCP102 graphical Chinese panel; no communication card, no MCO motion-control card.

  1. Essential Wiring Notes (power OFF; allow DC-bus minimum 20 min discharge time)

Main-Power Circuit

단말기기능비고
L1/L2/L33‑phase 380‑500 V inputDo NOT swap with U/V/W motor terminals
U/V/WMotor outputConnect to 3‑phase motor; shielded cable recommended
BR+ / BR‑Brake resistorFor built‑in brake chopper; connect brake resistor here, DO NOT connect to DC‑bus terminals
+DC /‑DCDC‑link busUsed for common‑DC‑bus multi‑drive systems; leave unconnected for standard operation
체육보호 접지Reliable earthing mandatory

Cable sizing suggestion for 55 kW: power-supply cable ≥16 mm²; motor cable ≥16 mm²; brake-resistor cable ≥10 mm².

Control-circuit mandatory connections (fault or drive-inhibited if ignored)

  1. STO Safe-Torque-Off: short terminal 12 에게 37. Without short-circuit, inverter output is inhibited. For external safety circuits, wire safety contacts in series.
  2. Coast-to-stop terminal 27 is factory-active: if coast-to-stop is not needed: set parameter 5-12 = 0 (no function). To retain coast-to-stop: 짧은 12-27.
  3. 터미널 12/13: internal +24 V output (max. 200 mA); terminal 20 = digital-input common ground.
  4. Analogue inputs: 53 (0-10 V voltage); 54 (4-20 엄마). Hardware dip-switches select voltage / 현재 모드.
  5. 터미널 68/69: RS485 Modbus-RTU; 68 = A, 69 = B.

Example terminal-based start-stop logic

18 (에서): 시작 (parameter 5-10 = Start)

19 (에서): 뒤집다 (parameter 5-11 = Reverse)

54: 4-20 mA frequency reference

계전기 01-02-03: configurable for Run / Fault signalling.

Practical advice: power-up without motor first and check I/O status. For commissioning, decouple motor coupling and test at low speed.

  1. Factory-reset procedures

Method 1: Recommended Initialisation (retains run-hours and communication settings)

  1. Main Menu → 14-Special Functions → 14-22 작동 모드
  2. 선택하다 2 Initialisation → press OK
  3. Disconnect main supply; wait until panel fully dark; re-apply power
  4. A80 “Drive initialised” informational message appears (not a fault); press Reset.

Method 2: Full Hard Initialisation (all parameters cleared)

  1. 전원 끄기; wait for panel to extinguish.
  2. Hold Status + Main Menu + OK keys together, then switch-on main supply.
  3. Keep holding for 5 s then release. Full factory reset completes on power-on.

Parameter backup tip: 0-50 LCP Copy → select 1 Copy all parameters to LCP. The panel can store parameters for download to identical units. Do NOT copy parameters across different power ratings.

  1. Key Commissioning Parameters (unit fitted with built-in brake chopper)
매개변수설명Suggested Setting
1‑01Motor Control PrincipleVVCplus / Flux Vector. Asynchronous motor: VVCplus; high low‑speed torque: select Flux Vector
1‑20~1‑26Motor Nameplate DataEnter nameplate power, 전압, 현재의, 빈도, speed exactly
1‑29AMA Motor Auto‑TuneStatic AMA; perform with mechanical load decoupled
2‑10Brake FunctionEnable built‑in brake chopper → 1 할 수 있게 하다
2‑11Brake‑resistor Ohmic ValueInput actual resistor value for thermal protection
2‑12Brake‑resistor Power RatingInput resistor power rating to activate resistor thermal‑model protection
3‑41/3‑42Ramp up‑/down‑timeLengthen deceleration for high‑inertia loads to avoid AL‑16 over‑voltage
5‑10/5‑11Digital‑Input FunctionsConfigure start‑stop, direction commands

Brake-chopper warning: short-circuited or under-rated low-ohm resistors will destroy the brake chopper. Always populate 2-11 & 2-12 for thermal protection.

  1. Incoming-inspection checklist for second-hand FC-302-55 kW (C4 frame)

육안검사

  1. PCBs: check for water ingress, corrosion or burn marks. Examine cooling air-path and fan for heavy dust. Manually spin fan for free rotation, 달라붙지 않음.
  2. 전원 단자: check for arcing / burn damage. Verify nameplate model string: FC-302P55KT5E20H2B G……, order No. 131F7151.
  3. Test all keys on LCP102 graphical panel.

Power-off static multimeter tests (full DC-bus discharge mandatory)

  1. Rectifier stage: measure forward / reverse diode drop L1/L2/L3 against +DC /-DC.
  2. IGBT stage: measure U/V-W versus +DC, -DC. Three-phase readings must be well-matched; large deviation indicates module failure.
  3. Brake circuit: test BR+ / BRchopper transistor for short-circuit breakdown.
  4. Confirm no control-terminal-to-earth short-circuits.

No-load power-on test (motor disconnected)

  1. Power-on, verify no active faults. Read run-hours 15-00; inspect fault-history log 15-30.
  2. Perform factory reset then AMA auto-tune. Run 0-50 Hz no-load; check three-phase output-voltage balance. Unbalance points to IGBT / drive-board damage.
  3. Brake-chopper functional test: set short deceleration time to induce regeneration; observe DC-bus voltage rise and brake activation.
  4. STO test: 열려 있는 12-37 link → STO fault appears; re-short to clear.
  5. Full point-by-point test for all digital inputs and relay outputs.

Motor-coupled test

Disconnect mechanical load. Run motor, verify balanced 3-phase current, no vibration or abnormal noise. High-overload 160 % / 1 min test: exercise with caution.

Common failure items: fan wear, current-sensor drift, brake-chopper damage, STO safety-circuit faults, aged electrolytic capacitors. Typical alarms: AL13 Over-current, AL16 Over-voltage, AL29 Heatsink Over-temp, AL-8 STO fault.

  1. Domestic Chinese-manufactured alternative selection (55 kW high-performance vector, 380-500 다섯)

FC-302 features: flux-vector control, asynchronous & PMSM support, built-in DC-link reactor, built-in brake chopper, expandable fieldbus cards, STO Safe-Torque-Off. Verify feature-match before substitution.

상표 & 모델주요 매칭 기능비고
혁신 MD380‑T55‑GOpen‑ / 폐루프 벡터; STO‑capable; 프로피네트 / EtherCAT expandable; brake‑unit optionalGeneral‑purpose industrial constant‑torque. Confirm brake‑chopper availability for your project.
INVT CHV190‑055G‑4High‑performance vector; asynchronous / PMSM support; expandable fieldbus; STOFor extruders, 컨베이어, 믹서; brake unit built‑in or external option
델타 CH2000‑55 kWFlux‑vector control; STO safety; expandable communication cardsHeavy‑duty applications, good substitution compatibility

Substitution caveats:

  1. Original FC-302 has integrated DC-link reactor. Many domestic alternatives omit this; add external DC-reactor for sites with high-harmonic-grid conditions.
  2. Original unit includes built-in B-option brake chopper. Confirm alternative unit has on-board brake chopper or plan for external brake unit.
  3. STO Safe-Torque-Off may be an option card for some domestic drives; do not overlook for safety-related machinery.
  4. 연락: base unit has no fieldbus card (MCA120 Profinet retrofittable). Confirm bus-interface requirements for replacement drive.
  5. Quick fault-troubleshooting guide
  6. Drive will not run; alarm AL-8: inspect STO loop (12-37 단락 / safety-contact continuity).
  7. Coast-to-stop-related alarm: either short 12-27 or set parameter 5-12 to no-function.
  8. Deceleration over-voltage AL16: ① extend deceleration ramp time; ② confirm brake chopper enabled; ③ validate brake-resistor value & 전력 등급.
  9. AL29 Heatsink Over-temperature: clean dust build-up, inspect fan, reduce carrier-frequency, limit sustained ambient temperature ≤40 °C.

Danfoss FC-302P55KT5E20H2BGXXXXSXXXXAXBXCXXXXDX Full Detailed Specifications

시리즈: VLT® AutomationDrive FC-302; 주문번호: 131F7152 (B = built-in brake chopper, G = LCP102 graphical Chinese panel)

프레임 크기: C4; IP20 cabinet-mount open-frame; 3-phase 380-500 V; 55 kW / 75 HP; integrated DC-link reactor, Class C3(A2) RFI filter, built-in brake chopper; no A/B/C/D option-cards; standard uncoated PCB.

  1. Main Supply Input Ratings
사양
입력 전압3‑phase 380‑500 V AC, tolerance ‑10 % ~ +10 %
입력 주파수50/60 Hz ±5 %
정격 입력 전류112 에이 (@400 V nominal)
Integrated DC‑link Reactor✅ Standard. Mitigates mains harmonics; meets IEC 61000‑3‑12
RFI / EMC 필터H2 = Class C3(A2), 2nd industrial environment. Factory‑floor application only; not for residential locations
Power‑Factor PerformanceHigh fundamental power factor > 0.98 via DC‑link reactor
Supply‑Drop‑Out HandlingVoltage ride‑through function configurable
  1. 모터 출력: 힘, 현재의 & 초과 적재 (C4 frame, 55 kW)
Continuous Power Rating55 kW / 75 HP
High‑Overload Continuous Output Current106 에이 (380‑440 V); 105 에이 (441‑500 V)
High‑Overload Intermittent Over‑current160 % × In = 169 A, 60 s duration, once per 10 min cycle
Normal‑Overload Continuous Current147 에이 (380‑440 V) / 130 에이 (441‑500 V)
Normal‑Overload Overload Ratio110 %, 60 s duration
출력 전압 범위0 up to input‑supply voltage
Output‑Frequency Range0‑1000 Hz
PWM Carrier‑FrequencyFactory default 4 kHz; adjustable 2‑16 kHz; derate power at higher carrier frequencies
Control AlgorithmsVVCplus, open‑/closed‑loop flux vector, permanent‑magnet synchronous motor, servo mode
Motor Auto‑Tune AMAStatic AMA and rotating AMA supported

Application guidance: High-overload for extruders, 믹서, 호이스트. Normal-overload for fan-pump quadratic-torque loads.

  1. Brake-circuit Specifications (B-option built-in brake chopper)
사양
Brake Chopper✅ On‑board integrated via BR+ / BR‑ terminals; external brake unit unnecessary
Peak Brake Power110 kW peak for this 55 kW frame
Minimum Permissible Brake‑resistor Resistance13 Ω minimum. Never use lower‑value resistors; chopper destruction risk
Brake‑resistor Thermal‑protectionSoftware thermal‑model via parameters 2‑11 resistor‑value; 2‑12 resistor‑power rating
DC‑bus Operating‑voltageTypical 540‑675 V; brake‑chopper activation threshold 785 V for 400 V systems
Common‑DC‑bus Compatibility+DC /‑DC terminals support multi‑drive common‑DC‑bus system architecture
  1. Safety-related Functions
  2. STO Safe-Torque-Off (hard-wired terminals 12-37), PL d / SIL 2 rating. Hardware-level IGBT gating inhibition; cannot be overridden by software.
  3. Coast-to-stop via digital-input terminal 27.
  4. 모터 열 보호: ETR electronic thermal relay; PTC / KTY84 temperature-sensor inputs.
  5. I/O Interface Specifications (제어 보드)

Digital Inputs DI (6 channels total)

Logic level 24 V, PNP / NPN compatible. Input impedance ~ 2 kΩ. On-board 24 V supply max. 200 mA.

터미널: 18, 19, 27, 29, 32, 33; common reference terminal 20.

Digital Outputs DO (2 open-collector channels)

24 다섯, maximum 40 mA sink-current.

릴레이 출력 (3 릴레이)

01-02-03: AC 250 V, 2 에이; 04-05-06; 07-08-09. Configurable for Run, 잘못, Alarm signalling.

Analogue Inputs AI

AI53: 0-10 V voltage input.

AI54: hardware-dip-switch selectable 0-10 V / 4-20 엄마. 입력 임피던스: voltage-mode 10 kΩ; current-mode 200 Ω.

Analogue Output AO

AO42: 0-10 다섯, max. 1 mA. Can output frequency, motor-current, torque etc.

Communications Interfaces

Standard hardware: RS485 Modbus-RTU (terminals 68 A, 69 B).

Slots A/B/C/D empty as-delivered. Retrofit-capable options: MCA120 (프로피네트), MCA121 (EtherNet-IP), MCA111 (디바이스넷), MCO305 motion-control card.

  1. 기계적 치수, 무게 & 환경 등급 (C4 frame IP20)
Height H1300 mm
폭W420 mm
Depth D386 mm
순중량46.4 kg
Gross Shipping Weight49.5 kg
냉각방식Forced air‑cooling; replaceable fan module; rear‑channel air‑flow path
설치Cabinet‑mount IP20 only, not for direct exposed field installation. Side‑by‑side tight‑pack cabinet‑mount permitted.

Environmental Operating Conditions

Operating ambient: -10 °C ~ +40 °C full power. Derate output > 40 °C; absolute maximum operating temperature 50 °C (저하된).

저장 & 운송 온도: -25 °C ~ +65 °C.

고도: full rating ≤ 1000 m above sea-level; derate 1 % output power per additional 100 m elevation.

PCB 코팅: XXXX = standard uncoated PCB. Specify coated-PCB variant for corrosive-gas environments.

  1. 전력 손실 & 능률

Total power loss at nominal load: approx. 1020 W.

능률: 98 % at rated operating point.

  1. 조작 패널 & 소프트웨어

LCP102 graphical multi-language Chinese-capable keypad-display (G-option). Parameter copy-backup feature; panel-extension-cable support for remote mounting.

Firmware identifier SXXXX = latest factory production firmware.

Commissioning software MCT-10: PC-connected upload / download parameters, fault-log recording.

  1. Hardware Protection & Alarm Events

Over-current, over-voltage, 저전압, earth-fault, 출력 단락, heatsink over-temperature, 모터 과부하, STO Safe-Stop, brake-resistor over-temperature, fan-fault, communication-fault.

  1. Full Model-code Re-check

FC-302 P55K T5 E20 H2 B G XXXX SXXXX A X B X C XXXX D X

FC-302: product family

P55K: 55 kW power

T5: 3-phase 380-500 V supply

E20: IP20 open-frame construction

H2: Class C3 RFI filter

비: 브레이크 초퍼 내장 (key feature of this unit)

G: LCP-102 graphical operator panel

XXXX: uncoated standard PCB, no auxiliary-power options

SXXXX: factory-standard firmware

도끼 / BX / CX / DX: slots A/B/C/D empty, no fieldbus or motion-control cards fitted.

Important note: Part-number 131F7151 corresponds to variant without brake-chopper and without operator-panel (B=X, G=X). The present full-feature unit uses order-number 131F7152 (B+G options).

이전:

답장을 남겨주세요