Leuze BCL22S-M312 Laser Barcode Scanner

(슬로건, not Lenze) 주문번호: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type) Model Decoding `BCL 22 S M 312` BCL22: 제품 시리즈, industrial fixed barcode reader S: Single-line scanning M: High-speed version, 1000 scans per second (N version = 800 scans/s) 312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm Key Technical ...

  • 제품 세부정보

(슬로건, ~ 아니다 렌츠)

주문번호: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type)

모델 디코딩

`BCL 22 S M 312`

BCL22: 제품 시리즈, industrial fixed barcode reader

에스: Single-line scanning

중: High-speed version, 1000 scans per second (N version = 800 scans/s)

312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm

주요 기술 사양

사양
광원655 nm red laser, laser class 2
Scan Rate1000 scans/s
Reading Distance50 … 260 mm
Barcode Module0.2~0.8 mm
Supported BarcodesCode39/93/128, EAN‑UPC, Interleaved 2‑of‑5, Codabar, Pharmacode
전원공급장치DC 10‑30 V, 최대. 310 엄마
입출력2 디지털 입력 / 2 디지털 출력, output max. 700 엄마
통신 인터페이스RS232 process port, RS232 service configuration port; 15‑pin male Sub‑D
유입 방지IP65
치수68 × 82 × 28 mm, weight 370 g
작동 온도0~+40℃, storage ‑20~+60℃

애플리케이션

Conveyor line barcode reading, 물류 분류, 포장 기계, production-line part identification, warehouse automation. Supports Auto-Config automatic setup, external trigger reading, multi-code reading (최대 63 codes).

인터페이스 & 부속품

15-pin male Sub-D connector; matching cable: KD BCL 2. MA30/MA31 modules extend Leuze multiNet-plus RS485 bus networking.

대사 / 호환 모델

  1. BCL22-SM312 (identical original part)
  2. BCL22-SN312: N-variant, 800 scans/s, identical optics
  3. Upgrade alternative: BCL348i SM 100 (new-generation, supports RS232/422/485 and Ethernet)

Common Fault Points & Used-Unit Inspection Checklist

  1. Polygon mirror motor aging: 비정상적인 소음, intermittent decode failures, stationary laser scan line
  2. Oxidation or broken wires at 15-pin Sub-D connector
  3. Scratched laser window leading to unstable decoding
  4. Damaged I/O output channels caused by over-current

메모: This device is manufactured by Leuze. Lenze is a drives brand; the two are frequently confused.

BCL22S-M312 (슬로건) 15-Pin Male Sub-D Pinout

Device side: 15-pin male Sub-D. MA2 / MA4 connection modules are strongly recommended; direct crimping of Sub-D plugs is not advised. Power supply DC10-30 V; I/O is PNP output, inputs active-high.

신호설명
1SW‑IN1Digital Input 1: external scan trigger
2SW‑IN2Digital Input 2: auxiliary function (다시 놓기 / barcode gate)
3SW‑OUT2Switch Output 2: decode success / status signal
4SW‑OUT1Switch Output 1: barcode read valid signal
5GND_SAI/O output ground
6VDD_INMain power positive DC10‑30 V
7GND_INMain power 0 V reference
8체육보호 접지; must connect to chassis ground for noise immunity
9RXD‑PROProcess‑port RS232‑RXD (scanner receive)
10TXD‑PROProcess‑port RS232‑TXD (scanner transmit barcode data)
11예약된, do not connect
12예약된, do not connect
13예약된, do not connect
14예약된, do not connect
15예약된, do not connect

배선 참고 사항

  1. 의사소통: Barcode data uses pins 9/10 RS232 process port. The 9-pin service configuration port resides on the MA wiring module and is not present on the 15-pin connector.
  2. 트리거 모드: Apply 24 V high level to SW-IN1 for one-shot trigger; 0 V stops scanning.
  3. 출력: SW-OUT1 / 2 are PNP, output voltage equals supply VDD_IN, 최대. 700 엄마. When connecting to PLC inputs, tie PLC common terminal to 0 V.
  4. MA2 / MA4 original modules are highly recommended. Home-brewed 15-Sub-D cables frequently cause communication instability and noise-related data loss.
  5. Always connect PE protective earth. Un-grounded units on conveyor systems suffer garbled data and false triggering.

Matching Cable Part-Numbers

KD BCL2: Standard cable with power, I/O and RS232 signals, typical lengths 3 m / 5 m; Order No. 50036410.

MA30 / MA31: MultiNet-Plus bus modules for RS485 multi-scanner networking.

Direct Replacement Comparison

BCL22S-M312: single-line laser scanner, 1000 scans/s, reading range 50-260 mm, barcode module 0.2-0.8 mm, RS232, 2-~에 / 2-out, IP65, for high-speed conveyor-line 1D barcode acquisition.

Imported Upgrade Replacements (project-level drop-in compatible, configuration reuse)

  1. BCL348i SM 100

Optical range 50-280 mm, 1000 Hz scan rate; adds TCP-IP Ethernet while retaining RS232, 2-~에 / 2-out I/O. Preferred upgrade for BCL22 series retrofits; Order No. 50124782.

메모: mounting hole pattern differs; custom adapter bracket required.

  1. BCL22-SM312: Exact original spare-part replacement, Order No. 50032097.

Domestic Alternative Scanners (for production-line retrofits)

Domestic Model주요 사양비고
Newland NLS‑FS500‑1DSingle‑line laser, 50‑300 mm, 1000 scans/s; RS232, 2IN/2OUT; IP65Conveyor‑line 1D reading; output format can emulate Leuze protocol, 비용 효율적
Hikrobot MV‑ID2000‑LSingle‑line laser, large depth‑of‑field; RS232/Ethernet configurable I/OFor new projects requiring direct MES Ethernet upload

메모: Domestic alternatives have different mechanical mounting dimensions. Serial protocol frames require commissioning; true plug-and-play is not possible. For legacy production-line spare-parts, prefer the BCL348i SM100.

Practical Used-Unit Test Procedure for BCL22

  1. Power-on and listen to polygon motor: steady low hum is normal. Rattling, jitter or stationary scan line indicates motor failure; repair costs are high, avoid purchasing such units.
  2. Inspect laser window for scratches or haze; scratches cause partial-field decode failures.
  3. I/O test: apply 24 V trigger to IN1; OUT1 must assert 24 V upon successful decode. Absent output indicates burnt output transistor.
  4. RS232 loop-back test by shorting TXD/RXD. Verify no broken conductors or bent / oxidized pins inside the 15-pin connector.
  5. Barcode read test using 0.3-0.5 mm module barcode across full 50-260 mm working range. Frequent failures at nearor far-range indicate degraded optics.

BCL22S-M312 Scan Frequency

1000 scans per second (1000 scans/s)

M = high-speed variant: 1000 헤르츠

Sibling N-variant (BCL22S-N312): 800 scans/s

보충: Polygon-mirror single-line laser delivers 1000 scan lines per second, suited for high-speed conveyor lines.

Optical version 312: reading range 50-260 mm, barcode module 0.2-0.8 mm.

BCL22S-M312 ↔ S7-200 SMART RS232 Wiring

⚠️ The native S7-200 SMART port is RS485 and cannot connect directly to RS232 scanner. SB CM01 signal board is mandatory, configured for RS232 mode, using Free-Port communication to receive barcode strings.

For BCL22 15-Sub-D male connector: MA2 / MA4 wiring modules are strongly recommended; avoid direct soldering to Sub-D plugs.

Hardware Cross-Wiring (3-wire RS232, no hardware handshaking)

BCL22 (15‑Pin Sub‑D) 핀Signal DescriptionSB‑CM01 Terminal
Pin10 TXD‑PRO (Scanner Transmit)Barcode data output from scannerTerminal 4 RxA (PLC Receive)
Pin9 RXD‑PRO (Scanner Receive)Commands sent to scannerTerminal 1 TxB (PLC Transmit)
Pin7 GND_IN (Power Ground)RS232 signal reference groundTerminal 3 M (PLC logic ground)

Rule of thumb: Scanner TX connects to PLC RX; scanner RX connects to PLC TX; common ground is mandatory. Missing ground leads to garbled characters and dropped data.

힘 & I/O Wiring (external-trigger mode, typical factory setup)

BCL22 power supply:

Pin6 VDD_IN: DC24 V positive

Pin7 GND_IN: 24 V return / 0 다섯

Pin8 PE: protective earth, connect chassis to ground for noise suppression

External scan trigger:

SW-IN1 (Pin1): driven by PLC digital output; 24 V high-level triggers scan, 0 V stops.

SW-OUT1 (Pin3): PNP output asserts 24 V on successful decode; wired to PLC digital input.

SB-CM01 System-Block Configuration (Micro/WIN SMART)

  1. System Block → SB CM01, communication mode select: RS232
  2. BCL22 factory-default serial parameters:

Baudrate: 9600

Data bits: 8, Stop bits: 1, 둥가: None

  1. PLC Port 1 (SB-CM01) set to Free-Port mode; SMB130 = 1600 (9600, 8-N-1 Free-Port).

Register note: SB-CM01 maps to Port 1. Free-Port control byte SMB130. Receive buffer uses SMB134-SMB141. RCV instruction targets Port 1, do not use Port 0 (on-board RS485).

BCL22 Scanner Parameter Setup (Leuze-Config software)

  1. 출력 모드: trigger-based reading; transmit barcode string automatically upon successful decode, suffix CR(0디) or CR+LF(0D0A).
  2. Disable XON/XOFF software flow-control; disable RTS/CTS hardware handshaking.
  3. Trigger source: rising edge on external IN1 for single-shot scan.
  4. Output format: transmit barcode payload only, no extra protocol headers.

PLC Free-Port Receive Logic

Use RCV instruction; define carriage-return CR (160디) as message end delimiter.

Upon complete receipt of barcode string, copy buffer contents to VB memory area; re-arm RCV instruction for next acquisition.

Timeout-only termination is discouraged. BCL22 appends CR character to every output string; frame delimiter is far more reliable.

Field Troubleshooting

  1. Garbled characters: missing common ground; baud-rate / parity mismatch; cable shield grounding at both ends.
  2. No data received: TX/RX swapped; download RS232 system-block configuration and power-cycle PLC to activate SB-CM01.
  3. I/O trigger does not start scanning: IN1 needs valid 24 V high level; scanner internal parameter must enable external-trigger mode.
  4. 케이블 길이 >15 m: RS232 is unsuitable for long distances. Use MA31 module for MultiNet-Plus RS485 bus extension.

Fall-back without SB-CM01

Native Port 0 is RS485. Fit an active RS232-RS485 converter. RS232 side connects to BCL22; converter RS485 side connects to PLC Port 0 terminals 3 & 8. Configure Port 0 for Free-Port. 산업 환경용, SB-CM01 solution is preferred; converters incur higher noise-error risk