IFM IFT245 All-Metal Inductive Proximity Sensor - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 IFM IFT245 All-Metal Inductive Proximity Sensor - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

감지기/

IFM IFT245 All-Metal Inductive Proximity Sensor

IFK3006-BPKG/AM/P/US IFT245 belongs to IFM IT hygienic all-metal inductive sensor series. It is designed for food and pharmaceutical applications with cleaning requirements. Featuring an all-metal sensing face, it can withstand high-pressure spray cleaning. ✅ Key Specifications Item Parameter Dimension M12×1, overall length 70 mm Sensing distance 6 mm, Non-flush mount (NF) Output type 3-wire DC PNP ...

  • 제품 세부정보

IFK3006-BPKG/AM/P/US

IFT245 belongs to IFM IT hygienic all-metal inductive sensor 시리즈. It is designed for food and pharmaceutical applications with cleaning requirements. Featuring an all-metal sensing face, it can withstand high-pressure spray cleaning.

✅ Key Specifications

목매개변수
차원M12×1, overall length 70 mm
감지거리6 mm, Non-flush mount (NF)
출력 유형3-wire DC PNP Normally Open (아니요)
공급 전압10~30 VDC
스위칭 주파수250 헤르츠
Max load current100 엄마
Hysteresis1~20% Sr
Reduction factorSteel=1; Stainless steel=1; Brass=0.9; Aluminium=0.8; Copper=0.6
주변 온도0~100 ℃
진입 보호IP69K (High-pressure washdown)
Max pressure on sensing face최대 100 술집
Protections역극성 보호, 단락 보호, 과부하 보호
재료스테인레스 스틸 하우징, all-metal sensing face, food-grade material
인증CE, cULus, EAC, EC1935/2004, FDA

📌 Model Code Definition (IFT Series)

만약에: Inductive proximity sensor

티: Hygienic all-metal series, wash & 고온 내성, dedicated for food & 음료 산업

245: M12, 6 mm 플러시되지 않은, PNP 아니요, 70 mm length, M12 커넥터

🧩 Construction & 배선

연결: M12 4핀 수 커넥터

핀 할당:

  1. 갈색: +24다섯
  2. 파란색: 0다섯
  3. 검은색: PNP NO 출력
  4. 사용되지 않음

🎯 Typical Applications

음식 & 음료, pharmaceutical and dairy production lines; CIP/SIP online cleaning equipment; workstations with frequent thermal cycling and high-pressure spray; metal workpiece presence detection and limit positioning.

장점: All-metal sensing face. Unlike conventional sensors with plastic front caps, it resists cracking and material buildup which causes bacterial growth. It withstands alkaline/acidic detergent flushing and thermal shock.

⚠️ Installation Notes

  1. Non-flush mounting: The sensor front end must NOT be embedded in metal. Sufficient clearance must be reserved for surrounding metal, otherwise the sensing distance will be reduced.
  2. Recommended target: Mild steel. Sensing range decreases when detecting aluminium or copper, so installation margin should be reserved.
  3. High-pressure cleaning: Direct spray from high-temperature high-pressure water gun is permitted, but avoid mechanical impact to the sensing face.

🔁 Alternative Model Reference

IFT244: 같은 차원, PNP 평상시 닫힘

IFT246: 같은 차원, NPN 상시 열림

IFT259: M12, 5 mm flush mount version

IGT247: M18, 5 mm flush mount, hygienic all-metal

🛠️ Common Troubleshooting

  1. 출력 없음: Check supply polarity (reverse polarity protected, but long-term reverse connection is not recommended); corrosion inside M12 connector due to water ingress; target beyond effective working distance (≤4.9 mm).
  2. 잘못된 트리거링: Strong nearby metal interference; temperature approaching 100 ℃ limit; cable routed in parallel with power cables causing EMI.
  3. Intermittent signal: Loose connector, water ingress after high-pressure wash, material buildup on sensing face.

📎 Additional Information

No IO-Link, discrete on/off version only

무게 약. 31 g

IFM IFT245 Typical Application Cases

Core advantages summary: M12 hygienic 316L stainless steel, IP69K, acid & alkali detergent resistant, thermal shock 0~100 ℃, sensing face pressure rating up to 100 술집, PNP 아니요, 6 mm 플러시되지 않은. Specially designed for hygienic production lines requiring daily CIP/SIP and high-pressure washdown.

사례 1: Filling head position detection on dairy filling lines (가장 일반적인)

Working condition: Stainless steel filling valves on fresh milk/yogurt aseptic filling stations. Daily CIP hot alkaline cleaning and direct high-pressure water spray, repeated thermal cycling from ambient to 85 ℃, corrosive detergents.

기능: Detect position of metal piston on filling cylinder. PLC allows material discharge only after confirming filling head is lowered in place.

Selection reasons

  1. IP69K rated for direct high-pressure washdown. All-metal front without plastic end cap prevents milk residue accumulation and bacterial growth, compliant with FDA / EC1935 food contact material requirements.
  2. Tolerates repeated thermal shock; conventional plastic-face sensors tend to crack and leak under such conditions.
  3. Compact M12 thread fits narrow space near filling valves; stable detection for stainless steel targets with 6 mm 감지 범위.

메모: Non-flush mounting required. Reserve clearance around adjacent metal to avoid sensing distance attenuation.

사례 2: Gripper position detection on PET bottle aseptic blow-fill-cap lines

Working condition: Aseptic cold filling line with daily disassembly cleaning, acidic disinfectant spray, 높은 습도, high-speed reciprocating movement of metal grippers.

기능: Confirm stainless steel bottle gripper fully clamped, preventing false filling of empty holders and bottle bursting.

Pain point solved: Plastic front caps of standard proximity switches corrode and blister under disinfectant spray. IFT245 one-piece all-metal construction resists disinfectant spray and delivers stable signal under vibration. 250 Hz switching frequency matches fast gripper motion.

사례 3: Cutting / conveyor limit for meat processing

Working condition: Ham & cooked meat production line, splashing brine, blood and grease. Daily high-pressure hot water + alkaline detergent wash, high humidity environment.

기능: Limit detection for stainless steel baffles and conveyor push blocks, verify pusher mechanism fully retracted.

Highlights: 316L stainless steel housing resists brine corrosion; sensing face withstands minor mechanical impact; gold-plated contacts in M12 connector reduce oxidation risk in humid environments.

사례 4: Position feedback of hopper doors for tablet presses / capsule fillers in solid dosage pharmaceutical

Working condition: GMP clean room, CIP cleaning, intermittent high-temperature steam purging. Clean area requires zero dead space for dust accumulation.

기능: Detect open/closed status of stainless steel hopper flip door. Interlock protection to prevent powder leakage once door locking is confirmed.

특징: Hygienic dead-space-free design; laser-etched nameplate will not peel off after repeated cleaning. Temperature range covers high cleaning temperature and meets GMP requirements for clean equipment.

사례 5: Tray presence detection for food retort / pasteurization lines

Working condition: Hot water pasteurization with cyclic temperature 0~95 ℃. Exterior of equipment undergoes daily high-pressure washdown, metal trays entering and exiting retort chamber.

기능: Confirm stainless steel tray in place before chamber door closes and sterilization cycle starts.

Fitment: Wide temperature range with thermal shock resistance. Sealing integrity maintained under splashing water and steam; sensing face rated for 100 바 압력.

사례 6: Stainless tray counting / presence detection for baking oven conveyor

Working condition: Cooling section after oven, hot baking trays, grease and flour dust, daily hot water cleaning.

기능: Detect tray presence and counting on conveyor; interlock to prevent conveyor blockage.

메모: Sensing distance reduces when detecting aluminium trays, installation margin must be reserved (reduction factor Al=0.8).

Extended non-food hygienic applications (less common but feasible)

Position feedback for valve actuators on pharmaceutical purified water pipelines with periodic sodium hypochlorite flushing; limit sensing for agitator mechanisms on small hygienic emulsification tanks.

General Site Implementation Guidelines (Applicable to all cases)

  1. 설치: Non-flush installation, do not embed into metal. Mild steel target recommended; best performance on stainless steel.
  2. 케이블: M12 4-pin A-coded connector. Food-grade washdown resistant M12 cable recommended.
  3. 보호: Avoid prolonged direct high-pressure jet hitting the thread and connector seam.
  4. Anti-fault measures: Route sensor cables away from high-power solenoid valves and motors to avoid EMI false triggering.
  5. 산출: PNP 아니요, compatible with mainstream hygienic PLCs such as Siemens and Rockwell Automation.

Alternative Models within the Series

Normally closed version: IFT244

NPN normally open: IFT246

M12 flush mount 5 mm: IFT259

IFM IT Hygienic All-Metal Inductive Proximity Sensor List (IFT / IGT / IIT / IET, series of IFT245)

Series common features: 316엘 (1.4404) all-metal sensing face, IP69K, max pressure rating 100 술집, 0~100 ℃, FDA / EC1935 food approval, M12 4-pin A-coded connector, 3-wire DC 10~30VDC.

Naming rule: IFT=M12, IGT=M18, IIT=M30, IET=M8; qf=flush/semi-flush, nf=non-flush; NO=Normally Open, NC=Normally Closed

IFT (M12×1, same housing sub-series as IFT245)

모델감지거리설치산출Overall Length mm비고
IFT2403 mmFlush qfPNP 아니요60Short range flush, food hygienic
IFT2443 mmFlush qfNPN 아니요60NPN variant of IFT240
IFT2456 mmNon-flush nfPNP 아니요70Main model in this document
IFT2466 mmNon-flush nfNPN 아니요70NPN variant of IFT245
IFT2476 mmNon-flush nf피엔피앤씨70Normally closed version
IFT2486 mmNon-flush nfNPN NC70NPN normally closed
IFT2595 mmFlush qfPNP 아니요45Compact short body 45mm
IFT2606 mmNon-flush nfPNP 아니요45Short housing for confined space
IFT2007 mmNon-flush nfPNP 아니요50Older M12 all-metal
IFT2054 mmFlush qfPNP/NPN programmable70Switchable output

IGT (M18×1 hygienic all-metal, same IT series)

모델감지거리설치산출Overall Length mm비고
IGT2475 mmFlush qfPNP 아니요70Most popular M18 hygienic model
IGT25012 mmNon-flush nfNPN 아니요70Long sensing range M18
IGT26110 mmFlush qfPNP 아니요45Short housing M18
IGT26212 mmNon-flush nfPNP 아니요45Short housing M18 non-flush

IIT (M30×1.5 hygienic all-metal, same IT series)

모델감지거리설치산출Overall Length mm비고
IIT24518 mmFlush qfPNP 아니요50M30 flush
IIT24625 mmNon-flush nfPNP 아니요65M30 ultra-long sensing distance

IET (M8×1 compact hygienic all-metal, same IT series)

모델감지거리설치산출Overall Length mm비고
IET2003 mmSemi-flush qfPNP 아니요45Smallest M8 hygienic type
IET2015 mmNon-flush nfPNP 아니요45M8 non-flush

🔎 Quick Selection Reference (Based on IFT245)

Same M12, 6 mm 플러시되지 않은, NPN → IFT246

Same M12, 6 mm 플러시되지 않은, Normally Closed → IFT247

M12, 5 mm flush, short 45mm body for tight space → IFT259

공간이 제한되어 있음, short housing 6 mm non-flush M12 → IFT260

Longer detection range, switch to M18 hygienic type → IGT247 (5 mm flush) / IGT250 (12 mm 플러시되지 않은)

✅ General Series Notes

  1. All sensors adopt all-metal sensing face, not PEEK plastic front used on standard sensors; designed exclusively for CIP/SIP cleaning applications.
  2. Reduction factor: Steel=1, Stainless steel=1, Brass=0.9, Aluminium=0.8, Copper=0.6.
  3. Mounting restriction: Non-flush (nf) models cannot be embedded in metal. Clearance must be reserved for surrounding metal or sensing distance will drop. 플러시(qf) versions can be embedded in metal.
  4. Uniform M12 A-coded 4-pin male connector for all; washdown food-grade cable recommended.
  5. No IO-Link, pure discrete switching output. IO-Link capability available on other IFM all-metal series.

Important Distinction: IC Series (Do not confuse)

IxC series also has all-metal sensing face, but it is developed for machine tool cutting fluid environments. No food hygienic certifications, cannot replace IT food-grade sensors.

이전:

답장을 남겨주세요

메시지를 남겨주세요