오므론 DCN1-3T-포트 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

오므론 DCN1-3T-포트 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

오므론 DCN1-3T-포트

DCN1-3T-포트 = DCN1-3. 업계에서는 일반적으로 DeviceNet T-브랜치 스플리터로 알려져 있습니다. / 3-포트 TAP 터미널 블록, it is printed with the markingT-PORT TAPand serves as a dedicated branching module for Omron DeviceNet fieldbus. Model Suffix Differentiation (Mandatory Reading for Procurement) Model Configuration Description DCN1-3 (bare unit) Base only, without 5 세트 ...

  • 제품 세부정보

DCN1-3T-포트 = DCN1-3. 업계에서는 일반적으로 DeviceNet T-브랜치 스플리터로 알려져 있습니다. / 3-포트 TAP 터미널 블록, it is printed with the markingT-PORT TAPand serves as a dedicated branching module for 옴론 DeviceNet fieldbus.

Model Suffix Differentiation (Mandatory Reading for Procurement)

모델Configuration Description
DCN1-3 (bare unit)Base only, without 5 sets of terminal blocks; XW4B terminals must be ordered separately
DCN1-3CStandard equipped with 5 side-entry screw terminals (most widely used in industry)
DCN1-3NCTop-entry latch-type terminals for screw-free fast wiring
  1. Hardware Port Structure (5-channel 5-pin DeviceNet Standard)
  2. 2 Main Line Ports: Bus trunk line input and output for daisy-chain networking
  3. 3 Branch Ports: 최대 지원 3 DeviceNet slave devices connected simultaneously (센서, remote I/Os, 인버터)
  4. Built-in Terminating Resistor Socket: Blue plug-in terminal on the module side. A 121Ω terminating resistor must be inserted at the bus end to suppress signal reflection

핀 정의 (Standard 5-pin DeviceNet):

1: V− (Power Negative), 2: CAN_L, 3: CAN_H, 4: V+ (Power Positive), 5: Shield Ground

III. 핵심 전기 & 기계 사양

  1. 전기 등급

Bus Standard: DeviceNet 2.0A / 2.0비

공급 전압: DC 11~24V (bus-powered)

Single Branch Current Rating: 맥스. 4에이; Total module rated current: 8에이

Matching Terminating Resistor: Built-in mounting position, supplied with 121Ω / 0.25W resistor

Supported Baud Rates: Full range 125k / 250케이 / 500 kbps

  1. 환경 & Mounting Specifications

설치: Snap-on mounting on standard 35mm DIN rail

전체 치수: 142(엘) × 45(여) × 31.3(디) mm

순중량: 110 g

작동 온도: -10℃ ~ +55℃

보관 온도: -25℃ ~ +70℃, Humidity 5%~95% non-condensing

보호 등급: IP20 (for cabinet installation only; not for outdoor exposed use)

  1. Networking Principle & 응용 시나리오
  2. Network Topology

The two main ports of DCN1-3 are directly connected to the trunk line, with independent equipment tapped off the 3 branch ports.

장점: No on-site wire stripping and jointing required; faults on one branch are isolated without disrupting communication on the entire bus.

제한: Total cable length per branch must comply with DeviceNet specifications (최대. 100 m per branch at 500 kbps).

  1. Typical Industrial Applications

Automotive assembly lines, 포장 기계, logistics sorting lines

Branch splitting for Omron DeviceNet remote I/Os (DRT series), 3G3MV / 3G3RX inverters, E3Z / E2E bus sensors

  1. 포장 목록 & 옵션 액세서리

Standard Factory Package for DCN1-3C

  1. 1 × DCN1-3 Main Unit
  2. 5 sets of 5-pin screw terminals XW4B-05C1-H1-D
  3. 1 × 121Ω bus terminating resistor

Separately Orderable Accessories

DCN1-3 (terminal-less version): Terminals need to be purchased additionally

DCN1-1 / DCN1-2: Compact 1-port / 2-port TAPs (alternative models within the same series)

DCA1 series DeviceNet bus cables, pre-assembled M12 connectors

  1. 일반적인 문제 해결 매트릭스
결함 현상근본 원인해결책
Branch devices undetectable during bus scanLoose terminal crimping; CAN_H / CAN_L reversed단자를 다시 조이세요; verify pin assignment for red and blue signal wires
Severe communication lag & packet loss across the whole busNo terminating resistors fitted at both bus endsInsert matching resistors into the DCN1 module at the far end of the link
No power supply to branch devices after power-onLoose crimps on V+ / V− power cablesInspect wiring on pins 1 그리고 4
Frequent disconnection of single-branch devicesExcessively long branch cables; ungrounded shieldingShorten branch cables; connect shield terminals to cabinet earth bar

Ⅶ. Cross-Series Alternative Comparison

모델Number of BranchesCable Entry Type응용 시나리오
DCN1-1C1 나뭇가지측면 나사 단자Short branch for single-point devices
DCN1-2C2 branches측면 나사 단자Compact layout with two slave devices
DCN1-3C3 branches측면 나사 단자Central multi-way splitting (주류 모델)
DCN1-4C4 branchesTop entryDense cabinet layout with multiple devices

설치 완료 & Configuration Manual for OMRON DCN1-3 (DCN1-3T-PORT)

The DCN1-3 is a dedicated T-type 3-way branching terminal block for DeviceNet (commonly referred to as T-PORT). The whole operation consists of six steps: Mechanical Mounting → Terminal Wiring → Terminating Resistor Setup → Network Topology Compliance → PLC Software Configuration → Power-On Test. All operations must be performed with power disconnected.

  1. Preparatory Tools & 재료
  2. Standard Supplied Materials (DCN1-3C terminal-equipped version)

DCN1-3 main unit, 5 sets of 5-pin screw terminals XW4B-05C1-H1-D, 1 × 121Ω terminating resistor

  1. 도구

Flathead screwdriver, 와이어 스트리퍼, dedicated 5-core shielded DeviceNet cable (Red = V+, Black = V−, White = CAN_H, Blue = CAN_L, Bare wire = Drain Shield)

  1. 소프트웨어

CX-Programmer + CX-Integrator (Omron DeviceNet network configuration tool)

  1. 단계 1: Mechanical DIN Rail Mounting (Power Disconnected)
  2. Rail Latches: Upper and lower latches are located at the unit bottom. Hook onto the top edge of a standard 35mm DIN rail first, then press down the bottom latch until a click sound confirms locking.
  3. Removal: Pinch the bottom latch outward and lift upward to detach the unit.
  4. Alternative Fixing: If no DIN rail is available, fasten the unit to the cabinet backplate via Φ3.5 mounting holes on both sides.
  5. 환경 요구 사항: IP20 rated, for cabinet interior use only. Keep away from high-interference sources such as inverters and contactors; operating environment range: -10~+55℃.

III. 단계 2: Terminal Definition & 표준 배선 (Core Procedure)

  1. Unified 5-Pin Pinout (Identical for all terminals)
핀번호.와이어 색상신호 이름기능 설명
1검은색V−24V bus power negative
2파란색CAN_LCommunication differential negative signal wire
3하얀색CAN_HCommunication differential positive signal wire
4빨간색V+24V bus power positive
5Bare Copper WireDrain ShieldCable shield grounding
  1. Distinction of 5 터미널 (2 Main Line Ports + 3 Branch Ports; Trunk lines must connect to the two marked terminals)

단말기 1 (): Trunk IN (Input from PLC master station / preceding bus segment)

단말기 2 (): Trunk OUT (Output to next bus segment)

> 주요 내용: The two terminals are directly connected with minimal internal resistance and must carry the main trunk line. The remaining 3 unmarked terminals are branch ports for external slave devices including DRT remote I/Os, inverters and bus sensors.

터미널 3/4/5: Independent branch outputs for Branch 1 / 2 / 3

  1. Terminal Wiring Procedures
  2. Pull out the XW4B terminal block and loosen all set screws.
  3. Strip 5 mm insulation from cable ends; crimp bare drain shield wire separately to Pin 5.
  4. Insert wires strictly in the order: Red to Pin4, Black to Pin1, White to Pin3, Blue to Pin2, then fully tighten screws (Multiple wires in one pin hole are prohibited).
  5. Reinstall the terminal block and confirm no loose wiring or exposed conductors.
  6. Shield Grounding Rule: Single-End Grounding. Connect Pin5 shield to the earth bar only inside the PLC master cabinet; leave shielding floating at remote device ends to avoid circulating current caused by double-ended grounding which disrupts communication.
  7. 단계 3: Terminating Resistor Installation (Critical for Stable Communication; Common Error Point)
  8. A dedicated black socket on the right side of the DCN1-3 unit is reserved for the supplied 121Ω terminating resistor.
  9. 규칙: Only fit one 121Ω resistor at each physical extreme end of the entire DeviceNet trunk line; no terminating resistors shall be fitted on any intermediate DCN1 splitters.

예: Fit a resistor at the PLC master port as the start of the link; fit another resistor on the last device / last DCN1 of the entire bus; leave resistor sockets empty on all intermediate DCN1 units.

  1. Prohibition: Fitting 3 or more resistors on one bus will pull down bus voltage and cause device disconnections.
  2. 단계 4: Mandatory Wiring Topology & Length Specifications (Violation Causes Direct Communication Failure)
  3. Topology Requirement: Must adopt Linear Trunk + Short Branches. Star or tree-shaped parallel wiring is forbidden.
  4. Branch Length Limits (Thin Cable Standard)

500 kbps: 맥스. single branch length ≤6 m; total length of all branches on network ≤30 m

250 kbps: 맥스. single branch length ≤6 m; total length of all branches on network ≤78 m

125 kbps: 맥스. single branch length ≤6 m; total length of all branches on network ≤156 m

  1. Wiring Separation: Maintain a minimum clearance of 10 cm between DeviceNet cables and power cables; cross perpendicularly if intersection is unavoidable. Long parallel laying is prohibited.
  2. Current Capacity: 맥스. 4 A per single branch; total module current ≤8 A. A supplementary DeviceNet power splitter DCN1-1P shall be added for multi-device branches requiring extra power supply.
  3. 단계 5: PLC Software Network Configuration (CX-Integrator)

The DCN1-3 only performs physical cable splitting, has no address and requires no independent software configuration. Only the bus master and downstream slaves need to be set up:

Operation Flow

  1. Launch CX-Programmer and create a new project; add PLC CPU (CJ1 / CP1 / NJ series) and insert a DeviceNet master module (예를 들어. CJ1W-DRM21).
  2. Right-click the master module → launch CX-Integrator network configuration tool.
  3. Set global bus baud rate (all devices on the network must share the identical baud rate: 125 / 250 / 500 kbps).
  4. Click [Network Scan]; the software will automatically identify all slave devices connected to the three branches of DCN1-3.
  5. Assign a unique node address (1~63, no duplicates) to each slave device.
  6. Configure I/O data mapping and download network parameters to the PLC master station.
  7. Save the project and close the configuration tool.

Ⅶ. 단계 6: Power-On, 통신 테스트 & 문제 해결

  1. Power-Up Sequence
  2. Double-check all wiring, terminating resistors and shield grounding for correctness.
  3. Power on the PLC and DeviceNet bus first.
  4. Power on slave devices on branches sequentially (remote I/Os, 인버터, 등.).
  5. Communication Acceptance Criteria

RUN indicator of PLC master module stays solid ON; ERR indicator remains OFF.

All scanned slaves show online status without red fault markers in CX-Integrator.

Stable read/write access to slave I/O signals with no packet loss or communication errors.

Quick Troubleshooting Matrix

결함 현상근본 원인해결책
No devices detected across the whole busCAN_H / CAN_L reversed; trunk line connected to branch terminals; no terminating resistors at both endsSwap wires on Pin 2 그리고 3; re-route trunk to * marked terminals; install 121Ω resistors at both ends
Single-branch devices drop offlineBranch cable exceeds 6 중; loose terminal crimping; overloaded branch currentShorten branch cables; retighten terminals; add supplementary bus power module
Intermittent communication lag & random disconnectionsDouble-ended shield grounding; parallel routing with power cables; excessive terminating resistors fittedFloat shielding at remote ends; separate cable routing; retain resistors only at two link ends
No 24V power to devicesLoose V+ / V− pins; insufficient bus supply powerRe-crimp red and black power cables; install DCN1-1P power splitter

Ⅷ. Non-Negotiable Installation Prohibitions

  1. Do not route trunk lines into the 3 unmarked branch terminals, which will trigger abnormal communication impedance.
  2. Do not fit terminating resistors on any DCN1 units other than the two physical bus ends.
  3. Do not use branch cables longer than 6 미터.
  4. Do not reverse CAN_H and CAN_L signal wires.
  5. Do not insert multiple conductors into one wiring terminal hole.
  6. Do not install outdoors without a cabinet (IP20 with no waterproof rating).

이전:

다음:

답장을 남겨주세요