상태: 단종 (End of Order) in Sep 2024. 재고만 있음 / used units available. New projects require alternative models.
시리즈: E8F2 Mini Cube Digital Pressure Sensor, Gauge Pressure, Positive Pressure, NPN Output
✅ Model Code Explanation
E8F2: 시리즈, LED digital display pressure sensor
에이: Measuring range 0~100 kPa (positive pressure)
01: 100kPa specification
기음: NPN open collector output; B = PNP version (E8F2-A01B)
📌 Key Specifications
| 목 | 매개변수 |
| Pressure Type | Gauge Pressure |
| Rated Range | 0~100 kPa (0~14.5 psi) |
| 보증 압력 | 400 kPa |
| Applicable Media | Non-corrosive, non-flammable gas (압축 공기, 등.) |
| 전원공급장치 | DC12~24V ±10%, ripple p-p ≤10% |
| Max Current Consumption | ≤70mA |
| 산출 | 2-channel independent NPN open collector switch output + 1~5V linear analog output (output impedance 1kΩ) |
| Switch Output Load | Max 30mA, external voltage ≤DC30V |
| 응답 시간 | ≤5ms (switch output) |
| 정확성 | Repeatability ±1%FS; Linearity ±1%FS; Display accuracy ±3%FS±1 digit |
| 작동 모드 | Hysteresis mode / Window mode / Auto-teach |
| 표시하다 | 3.5-digit red LED + green bar graph, orange LED for OUT status |
| Pressure Port | 아르 자형(PT)1/8 taper thread + M5 internal thread dual port |
| 케이블 | Pre-wired cable, standard length 2m |
| 인클로저 등급 | IP50 |
| 작동 온도 | 0~+55℃ (no icing); Storage -10~60℃ |
| 차원 | 28×28×29mm, Weight approx.110g |
| 보호 | 역극성 보호, 부하 단락 보호 |
🧩 Application Scenarios
Pneumatic pressure detection, vacuum adsorption (this model is positive pressure; select E8F2-AN0C for negative pressure), fixture pressure confirmation, air source pressure monitoring, pressure judgment in semiconductor/electronics production, OK/NG pressure judgment with PLC.
⚠️ Alternative Selection Recommendation (새로운 프로젝트)
E8F2 discontinued. 오므론 recommends next-generation E8CC series for replacement with same range 0~100kPa NPN digital pressure sensor.
Replacement checkpoints: pressure port, NPN output type, 1~5V analog signal, 장착 브래킷, 배선 정의.
🛠️ Accessories
E89-F3: Mounting bracket included with main unit
E89-F4: Panel mount bracket (별도로 판매됨)
📎 HS Code Reference (Customs Declaration)
90262090 Pressure sensor (for gas pressure measurement)
🔍 Inspection Checklist for Used Units
- 모습: 하우징에 균열이 발생하지 않음, no corrosion at pressure port, intact cable sheath
- 전원 켜기 테스트: LED digits and bar graph display normally, no garbled characters
- Zero-point reset function test
- Pressure calibration: Connect adjustable air source, verify readings and 1~5V analog output
- Operation test of 2 OUT switch outputs, hysteresis/window mode switching
- Insulation and short-circuit protection test
비교표: E8F2-A01C (원래의) vs E8CC-A01C (Official Recommended Replacement)
중요사항: E8FC is flow sensor and cannot replace E8F2 pressure sensor. The official direct replacement for E8F2-A01C is E8CC-A01C (0~100kPa, NPN, 2m 케이블). E8CC pressure sensor and E8FC flow sensor are frequently confused.
| 비교항목 | E8F2-A01C (단종) | E8CC-A01C (권장 교체) | Replacement Remarks |
| 제품 유형 | Mini Cube Digital Pressure Sensor | Slim Digital Pressure Sensor | Both gauge pressure, 0~100kPa positive pressure for gas measurement |
| 측정 범위 | 0~100 kPa (Gauge) | 0~98 kPa (≈0~100kPa, Gauge) | Equivalent for engineering application |
| Pressure Port | 아르 자형(PT)1/8 taper thread + M5 internal thread dual port | 아르 자형(PT)1/8 taper thread + M5 internal thread dual port | Thread identical, no air tube modification required |
| 전원공급장치 | DC12~24V ±10% | DC12~24V ±10% | Power supply compatible |
| 출력 구성 | 2-channel NPN open collector switch + 1~5V analog voltage | 2-channel NPN open collector switch + 1~5V analog voltage | Same signal type |
| Analog Output Spec | 1~5V, output impedance 1kΩ, load ≥500kΩ | 1~5V, output impedance 20Ω, load ≥10kΩ | E8CC analog output has stronger drive capability, no PLC analog input modification |
| Switch Output Load | Max 30mA per channel | Max 80mA per channel | E8CC has larger current margin |
| 응답 시간 | ≤5ms (switch output) | ≤5ms (switch output) | Same response speed |
| 정확성 | Repeatability±1%FS; Linearity±1%FS; Display ±3%FS±1 digit | Repeatability±1%FS; Linearity±1%FS; Display ±3%FS±1 digit | Same accuracy specifications |
| 작동 모드 | Hysteresis / Window / Auto-teach | Hysteresis / Window / Auto-teach | Identical menu logic |
| 인클로저 등급 | IP50 | IP50 | Only for dry cabinet installation, 방수가 아닌 |
| 케이블 유형 | Pre-wired 2m cable | Pre-wired 2m cable | Wiring color definition differs, do not directly match wires |
| 표시하다 | 3.5-digit red LED + bar graph | 2.5-digit LCD | Different display hardware, 동일한 기능 |
| 보증 압력 | 400kPa | 490kPa | E8CC higher proof pressure, 향상된 안전성 |
| 작동 온도 | 0~+55℃ (no icing) | −10~+55℃ | E8CC better low-temperature tolerance |
| 무게 | Approx.110g | Approx.80g | E8CC lighter, different outline; mounting bracket must be replaced |
| Applicable Media | Non-corrosive, non-flammable gas (압축 공기) | Non-corrosive, non-flammable gas (압축 공기) | Suitable for pneumatic adsorption & air source pressure monitoring |
| 상태 | 단종 2024, 재고 / used only | 단종, limited stock; E8PE recommended for new projects | E8CC also phasing out; select E8PE for new machine design |
Replacement Implementation Guide
✅ No air tube change, no PLC program modification. Only replace mounting bracket, re-set pressure threshold and zero calibration after power on.
⚠️ E8CC slim strip housing vs E8F2 cube housing. Mounting hole incompatible, original E89-F3 bracket cannot be reused. Use dedicated E8CC bracket.
Long-term Alternative for New Projects (E8PE Series)
When E8CC stock is exhausted, E8PE-B01C (0~100kPa, NPN, M12 커넥터, IO-링크, IP67) is recommended for new machines.
차이점: M12 connector instead of pre-wired cable; analog output changed to 4-20mA, PLC analog wiring adjustment required. Prioritize E8CC-A01C for direct retrofit of existing equipment.
Common Pitfall Reminder
E8FC is liquid flow sensor (for cooling water / oil flow + 온도 측정), NOT pressure sensor. Do not confuse E8CC pressure sensor and E8FC flow sensor during model selection.
Accuracy Parameters from OMRON Original Datasheet: E8F2-A01C vs E8CC-A01C
FS = Full Scale
| Accuracy Item | E8F2-A01C (0~100kPa) | E8CC-A01C (0~98kPa) |
| Switch Repeatability (켜기/끄기) | ±1%FS max | ±1%FS max |
| 선형성 (1~5V analog) | ±1%FS max | ±1%FS max |
| Total Analog Output Accuracy | 1~5V output: ±5%FS max | Analog output accuracy: ±3%FS max |
| Display Accuracy | ±3%FS ±1 digit (0~55℃ full temp range) | 0~50℃:±3%FS ±1 digit |
| 50~55℃:±4%FS ±1 digit | ||
| -10~0℃:±5%FS ±1 digit | ||
| Hysteresis (Switch dead band) | Adjustable built-in hysteresis | ≤2%FS |
Brief Explanation
- Switch judgment (OK/NG):Both have identical repeatability. Accuracy difference negligible for pneumatic pressure threshold replacement.
- 아날로그 획득 (PLC AD input):E8CC analog output has better overall accuracy (±3%FS vs E8F2 ±5%FS).
- Display reading:Identical specification at ambient 25℃. E8CC error increases at low temperature or near 55℃ high temperature.
- Minor range difference: E8F2 0~~100kPa; E8CC 0~~98kPa, acceptable equivalent in engineering.
Output Signal Comparison Table: E8F2-A01C vs E8CC-A01C
Both have identical output configuration: 2-channel independent NPN switch + 1 channel 1~5V analog voltage signal. No PLC interface modification required for retrofit.
| 목 | E8F2-A01C | E8CC-A01C | Replacement Remarks |
| 스위치 출력 | 2-channel independent NPN open collector. NO/NC configurable; Hysteresis / Window / Auto-teach supported | 2-channel independent NPN open collector. NO/NC configurable; Hysteresis / Window / Auto-teach supported | Same logic function |
| Max load current per switch channel | 30엄마 | 80엄마 | E8CC higher load capacity |
| Linear Analog Output | 1~5V voltage signal (1V@0kPa, 5V@full scale) | 1~5V voltage signal (1V@0kPa, 5V@full scale) | Same voltage level; E8CC low output impedance, compatible with standard PLC analog input |
| 출력 임피던스:1kΩ | 출력 임피던스:20오 | ||
| Minimum load resistance ≥500kΩ | Minimum load resistance ≥10kΩ | ||
| Switch response time | ≤5ms | ≤5ms | Same speed |
| Cable color assignment | 갈색: Power+, 파란색: 0다섯, 검은색: 아웃1, 하얀색: 아웃2, 회색:1~5V Analog | 갈색: Power+, 파란색:0다섯, 검은색:1~5V Analog, 하얀색:밖으로 | ⚠️ Wire color definition different! Do not hard connect by matching colors only |
| Communication Output | 없음 | 없음 | No RS485 / IO-Link for both |
주요 요약
✅ Same signal types: 2-channel NPN switch + 1~5V analog voltage, no PLC program change needed.
⚠️ Different wire color mapping, most common field replacement error point.
✅ Analog is voltage output, NOT 4-20mA current signal.
접촉기,회로 차단기,감지기,인코더,PLC,변환기