피닉스컨택트 DoubleLevel Pushin DINRail 터미널 블록, 주문번호: 3210567
기본정보
시리즈: PTTB 2.5 (CLIPLINE complete PT Pushin Series)
유형: Doublelevel feedthrough terminal block, 2 independent potentials, 4 연결점 (2 per level)
Connection Technology: Pushin toolfree connection. Solid conductors or stranded conductors with wire ferrules can be inserted directly. For bare stranded conductors, press the orange actuator lever before inserting wires.
설치: DIN rail NS35/7.5, NS35/15
너비: 5.2 mm, grey; Insulation material PA, UL94V0 flame retardant
Wire stripping length: 810 mm
전기 사양
| 매개변수 | 값 |
| Rated voltage Un | 500 다섯 |
| 정격 전류 입력 | 22 에이 (2.5 mm²) |
| 맥스. permissible current | 26 에이 (4 mm² solid conductor) |
| Conductor cross‑section | 0.14‑4 mm² / AWG26‑12 |
| 정격 전류 내전압 | 6 kV, Over‑voltage Category III, Pollution Degree 3 |
| 작동 온도 | -60℃ ~ +110℃ |
주요 특징
- Doublelevel independent circuits. Two signal/power circuits within one 5.2 mmwide unit, 캐비닛 공간 절약. Frontside wiring for easy operation in confined cabinet spaces.
- Builtin test jacks: test ports in doublefunction shaft plus extra external test connection. Multimeter probes can be applied without disconnecting wiring.
- 인증: UL, cULus, VDE, ATEX/IECEx for hazardous areas, DIN EN 455452 for railway, DNV marine certification. Suitable for railway equipment, machinery, process automation and explosive hazardous areas.
- Part of CLIPLINE complete system, compatible with system jumpers, marker strips and end partitions.
Commercial Data
주문번호: 3210567
표준 포장: 50 pcs per pack
단위중량: 대략. 11 g
Domestic Equivalent Reference
명세서: 5.2 mm doublelevel pushin terminal block, 2 electricallyisolated potentials, 0.144 mm², 22 에이, DINrail mount
혁신: ITB2.52D
바이드뮐러: A2T 2.5
DINKLE: DK2.52P
메모: 교체시, verify currentcarrying capacity, stripping length, jumper compatibility and certifications for explosionproof / railway projects.
PTTB 2,53210567
주문번호: 3210567|Product: Doublelevel electricallyisolated pushin DINrail terminal block|CLIPLINE complete PT Pushin series
- 기계 사양
| 목 | 사양 |
| Levels / Connection points | 2 levels, 4 터미널, full electrical isolation between upper and lower levels |
| Rail compatibility | NS35‑7.5 / NS35‑15 standard DIN rail |
| Unit width | 5.2 mm |
| 단열재 | PA polyamide, UL94‑V0 flame rating |
| Stripping length | 8‑10 mm |
| 단위중량 | ≈11 g |
| 연결 방법 | Push‑in connection; direct insertion for solid conductors / stranded conductors with ferrules; press orange actuator lever for bare stranded conductors |
| Conductor range | 0.14‑4 mm², AWG26‑12 |
| Pack quantity | 50 pcs |
- 전기 사양 (IEC 6094771)
| 목 | 값 |
| Rated voltage Un | 500 V AC |
| 정격 전류 입력 | 22 에이 (2.5 mm²) |
| 맥스. permissible current | 26 에이 (4 mm² solid conductor) |
| 정격 전류 내전압 | 6 kV, Over‑voltage Category III, Pollution Degree 3 |
| 작동 온도 | -60℃ ~ +110℃ (operational) |
| Touch‑safe protection | Finger‑ and back‑of‑hand safe protection per DIN EN 50274 |
- Builtin Functions & 액세서리 호환성
- Dual test points: test ports in doublefunction shaft plus separate external test jacks. Multimeter probes can measure signals without wire disassembly.
- 시스템 호환성: fully interoperable with CLIPLINE complete system accessories: jumpers, end partitions, ZB marker strips, separator partitions.
- 인증: UL/cULus, VDE, IECEx, DIN EN455452 railway, DNV marine, RoHS 규제.
- 일반적인 애플리케이션: cabinet I/O signal wiring, 전력 분배, railway equipment, process automation hazardousarea cabinets, marine equipment.
- 비교: PTTB 2.5 (3210567) vs PT2.5TWIN
Frequently confused doublelevel pushin terminal blocks
| 비교항목 | PTTB 2.5 (3210567) | PT 2.5‑TWIN (3211062) |
| Potential relation | Fully‑isolated two independent circuits | 높은 & lower levels internally connected, single potential (1‑to‑2 branching) |
| Connection terminals | 4 independent terminals | 4 터미널, upper‑lower levels electrically connected |
| Application purpose | Two isolated signals / two independent power circuits | One input branched to two outputs |
| 너비 | 5.2 mm | 5.2 mm |
| 평가 | 22 A /500 V | 22 A /500 V |
⚠️Selection Pitfall: Using TWIN (commonpotential) to substitute PTTB (isolated doublelevel) will result in shortcircuit upon poweron. Always verify potential relationship in projects.
- Selection Notes for Domestic Replacements
Reference models: Inovance ITB2.52D; Weidmüller A2T2.5; DINKLE DK2.52P
Mandatory confirmation: doublelevel electrical isolation, NOT TWIN commonpotential type
Verify: conductor range 0.144 mm², 22 A rating, 5.2 mm width, test jacks, leveractuated operating structure
For railway / explosionproof projects: domestic substitutes must satisfy corresponding certification requirements; mechanical dimension match alone is not sufficient.
- 설치 & 유지 관리 지침
- Do NOT forceinsert bare stranded conductors without ferrules. Always depress the orange lever before inserting bare flexible wires, otherwise internal spring damage and excessive contact resistance with overheating risk may occur.
- Jumpers shall only be applied within the same level. Crosslevel jumpering is prohibited; use dedicated jump wires for crosslevel connections.
- Use standard 2.3 mm multimeter probes. Oversized probes may damage test jacks.
Application Scenarios of PTTB 2,53210567 (Doublelevel Isolated Pushin Terminal Block)
Core characteristics: 5.2 mm width, electricallyisolated two independent circuits, 4 연결점, Pushin toolfree wiring, builtin test jacks; 22 에이 / 500 다섯; certified for railway, ATEX/IECEx hazardousarea, marine DNV applications.
⚠️Reminder: It is NOT a TWIN commonpotential terminal. Upper and lower levels are electrically separated for two independent circuits, NOT for 1to2 branching.
- Industrial Automation Control Cabinet (Most Common Use)
- PLC I/O Signal Circuits
One single terminal block handles two DI/DO signals to save DINrail space. Upper level connects to PLC side; lower level connects to field sensors / 액추에이터. Builtin test jacks allow multimeter measurement without disconnection during commissioning. Ideal for highdensity wiring in robot, 포장, injectionmolding and machinetool cabinets.
- Two independent control power distribution
Within one unit: one channel for 24 V control power, the other for isolated signal power, preventing interference between different power circuits. Used for smallsize solenoid valves and indicator light loops.
- Isolated inputoutput transfer
Two fullyisolated circuits for internal cabinet signal transfer, where signal grounds must be separated.
- RollingStock & Railway Vehicles (Certificationcritical Application)
Qualified with DIN EN455452 railway fireprotection and EN50155 vibrationshock standards. 넓은 작동 온도 60 ~ +110 ℃, 높은 진동 저항.
- Onboard cabinet: door control, airconditioning, 조명, passengerinformation systems. Compact cabinet requires highdensity wiring.
- Locomotive / EMU control panels: transfer of two isolated signals and power circuits. Springclamp connection avoids screwloosening under vibration.
Prefer original Phoenix unit for railway projects. Domestic alternatives must pass firesafety and vibration certifications; mechanical dimension matching is insufficient.
- 공정산업 / HazardousArea Cabinets (ATEX/IECEx)
- Chemical and pharmaceutical explosionproof cabinets: isolated transfer for intrinsicallysafe and nonintrinsicallysafe signals. Doublelevel isolation prevents crosscircuit interference, complying with hazardousarea wiring requirements.
- Transmitter signal wiring: one channel for 420 mA analog signal, the other for isolated alarm loop. Saves cabinet installation space.
- 선박 & Offshore Equipment (DNV Marine Approval)
Control cabinets on vessels and deck enclosures. Vibrationresistant, widetemperature, humiditytolerant. Used for two independent signal / power circuit transfer.
- 기타 산업용 애플리케이션
- 빌딩 자동화 / HVAC Control Cabinets: DDC controller wiring for two independent sensor signals (온도, 습기). Optimized for compact smallsize cabinets.
- NewEnergy Equipment (Energystorage, smallscale PV cabinets): Lowvoltage controlloop wiring for isolated 24 V signal channels.
- Testbenches & 실험실 장비: Two independent test circuits with convenient probeaccess test jacks to improve commissioning efficiency.
✅ Typical Correct Wiring Examples
- Upper level: Circuit A (24V+ /24V); Lower level: Circuit B (separate isolated 24V+ /24V), circuits fully independent.
- Upper level: DI input signal; Lower level: DO output signal, isolated signal transfer.
❌ Forbidden Practices
- Do NOT use as PT2.5TWIN (commonpotential 1to2 splitter). PTTB upperlower levels are insulated with no internal continuity. For oneinputtwooutput branching, select Order No. 3211062.
- Crosslevel jumpers are prohibited. Jumpers can only connect terminals on the same level.
선택 지침
Choose PTTB2.53210567: Two circuits require full electrical isolation.
Choose PT 2.5TWIN3211062: One signal to be branched into two outputs, upperlower levels internally connected.
접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC