Rockwell 1756-EN2TR 이중 포트 통신 모듈

1756:ControlLogix platform series ENRockwell EtherNet/IP communication 2:Dual-port Ethernet TTwisted-pair copper interface RDLR (Device-Level Ring) 지원하다 (core identifier) Core Technical Specifications Item Parameter Interfaces 2×RJ45 with embedded switch, both ports share one single IP address, independent sub‑networks are not supported Speed 10/100 Mbps auto‑negotiation Backplane Power Consumption 5.1V DC, 1에이; power dissipation 5.1W CIP Connections Max. 256 ...

  • 제품 세부정보

1756:ControlLogix platform series

안에:록웰 이더넷/IP 의사소통

2:Dual-port Ethernet

티:Twisted-pair copper interface

아르 자형:DLR (Device-Level Ring) 지원하다 (core identifier)

핵심 기술 사양

매개변수
인터페이스2×RJ45 with embedded switch, both ports share one single IP address, independent sub‑networks are not supported
속도10/100 Mbps auto‑negotiation
Backplane Power Consumption5.1DC에서, 1에이; power dissipation 5.1W
CIP Connections맥스. 256 CIP connections; 128 TCP connections
Message Processing25000 조달청; supports up to 8‑axis CIP Motion
TopologiesStar, linear daisy‑chain, DLR Device‑Level Ring (single‑link fault self‑recovery)
작동 온도0~+60℃; 1756‑EN2TRXT wide‑range version: ‑25~+70℃
설치Any slot in ControlLogix chassis, RIUP hot‑swap supported
Firmware SeriesMainstream Series‑C; suffix K: 1756‑EN2TRK conformal coated version
격리Basic insulation between Ethernet and backplane; USB port for temporary commissioning only, prohibited in hazardous areas

⚠️Important: EN2TR only supports DLR ring redundancy. PRP dual-network and dual-IP hot-standby redundancy are NOT available. Two ports operate as an embedded switch, not two independent network adapters.

Primary Application Scenarios

  1. EtherNet/IP remote I/O and distributed I/O (예를 들어. 1734-AENTR) for ControlLogix controllers
  2. DLR ring architecture: 조립 라인, 포장 기계, 수처리, 자재 취급, auto network self-recovery upon single cable breakage
  3. HMI & SCADA host communication; CIP-Motion servo motion network
  4. Preferred upgrade replacement for legacy 1756-ENBT, delivering greatly improved performance

시리즈 선택 & 비교

모델포트DLR기가비트특징
1756‑EN2T1×RJ45Basic single‑port EtherNet/IP, no ring support
1756‑EN2TR2×RJ45Dual‑port DLR, widely deployed in projects
1756‑EN2TP2×RJ45PRP dual‑network redundancy, dual independent IP addresses
1756‑EN4TR4×RJ45기가비트, CIP‑Security, 512 사이, next‑generation upgrade option

교체 옵션

  1. Direct drop-in replacement: 1756-EN2TR (Series-C). Keep consistent firmware revision; plug-and-play without program modification
  2. 성능 업그레이드: 1756-EN4TR (기가비트 이더넷, higher connection capacity, CIP security support)
  3. Harsh environment variants: 1756-EN2TRXT wide-temperature; 1756-EN2TRK conformal coating

Hardware Installation & IP Configuration Guidelines

  1. RIUP hot-swap supported; hot-swap forbidden in hazardous / 폭발 위험 지역
  2. IP configuration methods:

Module thumbwheel: setting static IP `192.168.1.xxx` via setting 1-254; 위치 999 enables BOOTP/DHCP assignment

Static IP assignment via BOOTP-DHCP tool; configure IP inside Studio5000 project and download

  1. DLR ring wiring: Port1 connects upstream device, Port2 connects downstream device; close both ends to form a ring. At least one DLR Supervisor (ring manager) must exist in the ring. Ordinary non-managed switches cannot be inserted into DLR ring, which causes ring flapping and communication failure.
  2. Cable requirement: minimum Cat5e shielded Ethernet cable

일반적인 문제 해결

  1. Ring convergence failure: Ordinary switches or multiple Supervisor nodes inside ring. Remove non-managed switches and retain exactly one Supervisor.
  2. I/O glitch after cable break: DLR convergence time exceeds RPI request packet interval. Use PRP module (EN2TP) for motion-critical applications.
  3. Duplicate IP alarm: Both ports connected to same switch network. One port for ring connection only; never plug both ports into common switch.
  4. Electronic key error 160114: Firmware mismatch between project definition and physical hardware. Enable compatible-module setting or upgrade module firmware.

Key LED Indicators

좋아요: Module status; steady green = normal; flashing red = self-test; solid red = module fault

LNK/ACT: Port link & data activity indicator

NET: Network status

DLR: Device-Level Ring status

I can provide further materials upon request:

  1. Minimal DLR ring configuration steps (Studio5000)
  2. Index for official 1756-EN2TR Chinese manual
  3. Inspection checklist for second-hand modules

1756-EN2TR Main Application Scenarios

Module positioning: Dual-port EtherNet/IP communication module for ControlLogix platform with DLR Device-Level Ring. Embedded switch shares one IP address; PRP dual-network redundancy is unsupported.

  1. DLR Device-Level Ring (핵심 이점)

For field-level networks requiring self-recovery (<3 ms convergence) against single cable damage. Supports star, linear daisy-chain and closed DLR ring topologies.

자재 취급 & 라인 정렬; 포장 & filling lines; 자동차 용접 & assembly station networks

Remote I/O ring for water treatment, 펌프장, tunnels and bridges; reduces switch count and cabling cost

Ring prerequisites: All ring nodes must be DLR-capable. Exactly one DLR Supervisor is required. Ordinary non-managed switches shall not be inserted.

  1. Distributed Remote I/O Master Communication

Acts as backplane-mounted EtherNet/IP interface for ControlLogix, connecting remote I/O adapters such as 1734-AENTR and 1738-AENTR.

Collect DI/DO, AI/AO signals for widely dispersed field points in large-scale plants

Direct upgrade substitute for legacy 1756-ENBT; no chassis or program modification, higher connection capacity and message performance.

  1. CIP-Motion Motion Control Network

Supports up to 8-axis CIP-Motion servos, interfacing with Kinetix servos and PowerFlex variable-frequency drives.

Real-time servo control for packaging machines, material handling equipment and machine tools.

메모: When running CIP-Motion over DLR ring, properly tune RPI interval to avoid motion glitches triggered by ring convergence events.

  1. HMI, SCADA & MES Data Exchange

Interfaces with PanelView HMI terminals, FactoryTalk SCADA hosts; upload production data to MES systems

Acquire data from VFDs, smart instruments and third-party EtherNet/IP devices

Maximum 256 CIP connections and 128 TCP connections support multi-device concurrent communication.

  1. Industry-Specific Typical Deployments
  2. 자동차 제조: 용접 & paint shops, connecting robots, station I/O and VFDs via DLR ring per cell.
  3. 음식 & beverage packaging: 충전재, labelling and end-of-line packaging; daisy-chain / DLR wiring cuts field switch quantity.
  4. Municipal water treatment: Waste-water & clean-water plants, pump-station remote-I/O rings with central SCADA supervision.
  5. Warehouse & 기호 논리학: AS/RS automated warehouses, sortation conveyors for long-distance daisy-chain or DLR networking.

❌ Not-Recommended Use-Cases (선택의 함정)

  1. Dual-independent-IP / PRP true dual-link redundancy: Select 1756-EN2TP instead of EN2TR. EN2TR ports function as bridged switch ports rather than two independent NICs.
  2. Gigabit requirement: EN2TR is 10/100 Mbps only; upgrade to 1756-EN4TR for gigabit speed.
  3. Dual-network hot-standby for redundant controller systems: 적합하지 않음; use two separate communication modules.

Network Topologies Supported by 1756-EN2TR

Hardware key fact: Dual ports implement internal Layer-2 switch, one shared IP with two MAC addresses; not two independent network interface cards.

✅ Three Supported Topologies

  1. DLR Device-Level Ring (핵심 기능)

Module can operate as a regular DLR ring node or be configured as DLR Supervisor (ring manager).

Wire Port1 to upstream device and Port2 to downstream device, close both ends to form closed ring.

Automatic self-healing when one cable fails; convergence time <3 ms.

요구사항: Every ring participant must support DLR. Only one Supervisor node allowed within ring. Non-managed switches must be excluded.

Use-case: Field-level redundant networking for conveyors, water-treatment and assembly lines.

  1. Linear Daisy-Chain Topology

Port1 connects upstream device; Port2 daisy-chains next DLR-capable I/O device. Both ends remain open without ring closure.

Eliminates field switches by cascading devices sequentially and lowers hardware cost.

Drawback: Any intermediate cable failure takes down all downstream devices. No fault-tolerant recovery.

  1. 스타 토폴로지

Use only one RJ45 port to connect to standard switch; leave second port unused.

Traditional widely-adopted EtherNet/IP topology for HMI, SCADA and remote-I/O connections.

⚠️Strict prohibition: Never plug both ports into the same ordinary switch. This creates Layer-2 loop, triggers duplicate-IP alarm and collapses network traffic.

❌ Unsupported Topologies (선택의 함정)

  1. PRP parallel dual-network redundancy: EN2TR does not implement PRP protocol. Choose 1756-EN2TP for physically separate redundant networks.
  2. Separate sub-networks / dual-IP for two ports: Hardware limitation forces single shared IP; different sub-nets cannot be assigned per port.
  3. Dual-NIC hot-standby for redundant controller pairs: Cannot realize true dual-network redundancy; deploy two discrete communication modules.

Topology Quick Reference Table

토폴로지중복성Port Utilization일반적인 응용
DLR Closed RingSingle‑link fault self‑recoveryPort1+Port2 closed loop조립 라인, distributed I/O with high cable‑failure risk
Linear Daisy‑ChainNo redundancyPort1+Port2 open‑end cascadeLong‑run cabling, cost‑sensitive projects accepting single‑point‑of‑failure risk
StarNo redundancyOne single port onlyControl‑room side for HMI / SCADA / multi‑drop remote I/O

보충: Although CIP-Motion can run on DLR ring, cable break-triggered convergence may cause transient I/O or motion jitter. Star topology or PRP module is preferred for high-performance motion applications.

이전:

다음:

답장을 남겨주세요