피닉스컨택트 PSR-SPP-24DC/ESD/4X1/30 안전 릴레이 (품목 번호: 2981813)
상표: 피닉스컨택트
- 모델 코드 분석
`PSR-SPP-24DC/ESD/4X1/30`
- PSR: Safety relay of PSRclassic series
- SPP: Push-in spring cage terminals (tool-free pluggable wiring)
- 24DC: Control coil rated voltage DC24V
- ESD: Electrical Switch-off Delay (dropout delay function)
- 4X1: 4 safety normally-open contacts (2 동시에 일어나는, 2 delayed)
- 30: Adjustable delay range: 0.1s ~ 30s
- Core Safety Ratings & 규정 준수 표준
Forcibly guided mechanical contacts: IEC/EN 61810-3
Machinery safety: 카테고리 4 / PL 전자 (ISO에서 13849-1)
기능적 안전성: 실 3 / SILCL3 (IEC 62061 / IEC 61508)
Applicable safety devices: Emergency stop pushbuttons, safety door interlock switches, safety light curtains
- 주요 전기 사양
3.1 Control Input (코일)
정격전압: DC24V, permissible operating range 0.85~1.1Un
Operating current: 75엄마
Response actuation time: 150ms
Reset recovery time: 330ms
3.2 출력 접점 (4 N/O Normally Open)
Instantaneous contacts: 2 PC, release time ≈20ms
Delayed contacts: 2 PC, 조정 가능한 지연: 0.1~30 seconds
Contact material: AgSnO₂
Continuous rated current: 6에이 / 250V AC/DC
맥스. power for resistive loads: 1500버지니아 (AC250V), 144여 (DC24V)
Minimum switching capacity: 0.4여, minimum carry current 25mA
기계적 수명: 10 million switching cycles
3.3 배선 & 설치
터미널: Pluggable push-in spring cage terminals (SPP)
설치: 표준 35mm DIN 레일
보호 등급: IP20 (for cabinet internal installation only)
무게: 대략. 0.24kg
- 기능적 특징
- 2-channel monitoring: Supports single/dual-channel safety circuit connection, compatible with dual-channel E-stop and safety door interlocks
- Two reset modes: 자동 재설정 / manually monitored reset (with feedback loop)
- Dropout delayed output: Delayed power cut-off for drives after equipment shutdown, ideal for scenarios requiring inertia coast-down of motors and slow stop of conveyors
- Tamper-proof design: Sealable delay adjustment knob to prevent unauthorized on-site modification of delay settings
- Built-in self-diagnosis: Integrated diagnostic LEDs to rapidly identify power supply faults, safety circuit open-circuits and reset failures
- 일반적인 애플리케이션 시나리오
E-stop safety circuits for machine tools, injection molding machines and stamping equipment
Safety guard door monitoring for automated production lines
Signal evaluation for safety light curtains in robot workcells
Delayed power disconnection for conveyor and roller motors with inertia stop
- Cross-Series Alternative Comparison
| 모델 | 품목 번호. | 터미널 유형 | 지연 범위 | 연락처 구성 |
| PSR-SPP-24DC/ESD/4X1/30 | 2981813 | Push-in spring cage | 0.1~30초 | 2 instantaneous N/O + 2 delayed N/O |
| PSR-SCP-24DC/ESD/4X1/30 | 2981800 | 나사식 터미널 | 0.1~30초 | 2 instantaneous N/O + 2 delayed N/O |
- 획득 & Stock Information
Member price on official domestic store: 대략. 위안화 3,475; standard minimum order quantity 1 piece per carton; industrial automation spare parts kept in regular stock.
Full Application Scenarios of PSR-SPP-24DC/ESD/4X1/30 (Item No.2981813)
Core advantages of this model: 2-channel safety monitoring + 2 instantaneous safety contacts + 2 dropout delay contacts (0.1~30초) + Cat.4/PL e/SIL3. It is specially designed for safety conditions where equipment carries large rotational inertia and cannot be fully powered off instantly. All scenarios support monitoring of three categories of safety components: 비상 정지 버튼, safety door interlocks and safety light curtains.
- Basic Safety Signal Monitoring (Universal for All Automated Equipment)
1.1 Dual-channel Emergency Stop Circuit Monitoring
Dual-channel E-stop detection for machine tools, standalone production line units, robots and packaging machinery
Supports manually monitored reset / 자동 재설정, with detection of short-circuits and open-circuit faults in E-stop wiring
Instantaneous contacts cut off main drives immediately; delayed contacts control slow stop of auxiliary loads including fans, conveyors and lubrication systems
1.2 Equipment Safety Guard Door Monitoring
Dual-channel monitoring of safety door interlocks for stamping machines, injection molders, 머시닝 센터, robot enclosures and automated modules
Main spindle/servo power is instantly cut off when the door opens; 냉각, chip removal and conveyor systems keep running with delay until full inertia stop before disconnection
Detects cross-wire short-circuits in door switch wiring, fully compliant with machinery safety standards
1.3 Safety Light Curtain Signal Evaluation
Safety circuits for light curtains on stamping, 굽힘, robotic loading/unloading and packaging lines
Main motor cuts off instantly upon curtain obstruction; delayed contacts operate discharge roller conveyors to clear residual materials
Built-in cross-circuit fault diagnosis, meeting the highest PL e safety rating requirements
- Core Featured Scenarios (Relying on ESD Dropout Delay Function, Exclusive Strength of This Model)
2.1 운반 & 물류장비 (Belt Conveyors, Roller Lines, Stacker Cranes)
벨트 컨베이어, roller sorting lines, automated warehouse roller conveyors, packaging transport lines
Operating logic: After E-stop or door opening, main drive cuts off instantly; rollers remain running for an adjustable delay of 0.5~10s to clear materials on belts, avoiding material extrusion, machine jamming and belt tearing
Widely applied in food packaging, warehousing logistics and lithium battery assembly lines
2.2 Rotational Inertia Load Equipment (팬, Centrifugal Machines, 믹서, Extruder Screws)
Injection extruders, pelletizing screws, high-speed agitators, centrifugal dehydrators, high-power cooling fans, 공기 압축기
Operating logic: Main spindles carry massive inertia; instant power-off risks screw fracture and impeller damage. Main power is cut off instantly, while lubrication and cooling fans keep operating for 3~30s until rotational speed drops to zero before auxiliary circuits are disconnected
Standard configuration for plastic extrusion, chemical mixing, lithium coating and rubber pelletizing industries
2.3 Web Winding, Slitting & 인쇄 장비
Film slitters, paper printing machines, non-woven winders, lithium battery electrode slitters
After safety trigger, winding/unwinding servos cut off instantly; tension rollers keep running for 2~8s to prevent sudden web breakage and flying material hazards to operators
2.4 공작기계 & 금속 가공 장비
CNC machining centers, CNC 선반, punch presses, 벤딩 머신, 그라인더, 레이저 절단기:
- Instant cut-off of spindle servos when safety door opens or E-stop is activated
- Delayed contacts continuously run cutting fluid pumps, cooling fans and chip conveyors; all power disconnected upon delay expiry
- Prevents damage to cutting tools and spindle bearings caused by rapid shutdown of hot spindles without cooling
2.5 Robot Workcells & Automated Assembly Units
6-axis robots, gantry manipulators, loading/unloading modules, welding stations:
Robot servos cut off instantly upon trigger from enclosure safety doors or area light curtains
Delayed control for slow stop of conveyors, fixture air blow dust removal and cooling fans
Compliant with safety specifications for auto parts and 3C electronics assembly
2.6 음식, 제약 & Packaging Equipment
충전물 기계, 씰링 기계, horizontal form fill seal packaging machines, pharmaceutical sorting equipment:
Main transmission cuts off instantly when safety guards are opened
Discharge conveyors run delayed to clear food/medicine bottles, avoiding mold jamming and cross-contamination from accumulated materials
- Summary of Complete Sets of Applications by Industry
- 공작기계 산업: CNC equipment, punch presses, 벤딩 머신, laser cutters, 사출 성형 기계
- 기호 논리학 & Warehousing Industry: Belt conveying, roller sorting, automated warehouse stacker cranes
- 고무, 플라스틱 & 화학 산업: Extrusion pelletizing, high-speed mixing, film slitting machines
- 로봇공학 & 오토메이션: 용접, loading/unloading, enclosure safety protection for 3C assembly robots
- Lithium New Energy Industry: Safety monitoring for electrode slitting, coating and cell assembly lines
- 음식 & 제약 산업: Safety door + light curtain monitoring for filling, packaging and sorting equipment
- General Fan & Air Compressor Station: Safety circuits for maintenance access doors of high-power fans and water chillers
- Model Selection Guidance (Why Choose This Model Over Standard Non-Delayed Safety Relays)
- Standard safety relays cut off all contacts simultaneously; inertia loads easily suffer equipment damage and material jamming
- This model separates instantaneous safety circuits and delayed auxiliary circuits, balancing operator personal safety and equipment protection
- Push-in spring cage terminals (SPP) enable tool-free wiring and higher mass assembly efficiency in control cabinets
- Sealable delay adjustment knob prevents equipment faults caused by unauthorized on-site personnel shortening delay time
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지
















NH42-63-318x560.png)