RITTAL SK3201300 Filter Fan - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

RITTAL SK3201300 Filter Fan - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

전기 같은/

RITTAL SK3201300 Filter Fan

상표:RITTA Product Category:Enclosure Climate Control / Cooling Accessories, 제품명:Filter Fan Unit (Axial Fan, for Enclosure Side / Top Mounting), Aliases:Filter Fan, Fan-and-Filter Unit, 부품 번호:SK 3201.300, Mounting Cut-out:223 × 223 mm, 전반적인 차원:255 × 255 × 49 mm, VoltageModel: RITTAL SK3201300 Filter Fan Brand: RITTAL Product Category: Enclosure Climate Control / Cooling Accessories Product ...

  • 제품 세부정보

상표:RITTA

제품 카테고리:Enclosure Climate Control / Cooling Accessories,

제품명:Filter Fan Unit (Axial Fan, for Enclosure Side / Top Mounting),

Aliases:Filter Fan, Fan-and-Filter Unit,

부품 번호:SK 3201.300,

Mounting Cut-out:223 × 223 mm,

전반적인 차원:255 × 255 × 49 mm,

VoltageModel: RITTAL SK3201300 Filter Fan

상표: RITTAL

제품 카테고리: Enclosure Climate Control / Cooling Accessories

제품명: Filter Fan (Axial Fan, 맨 위 / Side Mount for Enclosure)

Aliases: Filter Fan, Fan-and-Filter Unit

부품 번호: SK 3201.300

Mounting Cut-out: 223 × 223 mm

전반적인 차원: 255 × 255 × 49 mm

전압: 230 뷔와

힘: 55 여

Airflow: 105 m³/h free blowing, 85 m³/h with filter fitted

보호 등급: IP54

색상: RAL7035 (Light Grey)

필터: Replaceable polyester filter mat

애플리케이션: 열 방출, ventilation and dust prevention for electrical control cabinets, PLC cabinets and industrial control cabinets

SK3201300 (RITTAL)

Full model designation: SK 3201.300, commonly abbreviated as SK3201300 in industry

✅ Basic Specifications

사양
제품 유형Enclosure fan-and-filter unit (옆 / top mount ventilation cooling unit)
전원공급장치230 뷔와, 50/60 헤르츠
전력 소비55 여
Airflow105 m/h without filter; 85 m/h with filter installed
전체 치수255 * 255 * 49 mm
Enclosure Cut-out223 * 223 mm
보호 등급IP54
Housing ColorRAL7035 light grey (standard Rittal enclosure colour)
필터 요소Replaceable polyester filter mat
장착 방법Snap-fit installation into sheet metal cut-out of enclosure

📌 Product Description

Rittal SK3201.300 belongs to the SK series fan-and-filter units. It is used for air exchange and heat dissipation in electrical cabinets, PLC control cabinets and variable frequency cabinets. External air passes through the filter and enters the cabinet to remove heat from electrical components, while blocking dust and maintaining slight positive pressure inside the cabinet to reduce dust ingress.

Airflow direction: blow air from outside into the cabinet

애플리케이션: Indoor industrial control cabinets, non-explosion-proof environments

Spare part: Replacement filter mat SK3201.000

⚠️ Selection & 교체 지침

  1. Interchangeable Rittal model with identical cut-out: SK3201.230 (24V DC version). Cannot be directly substituted due to different supply voltage.
  2. IP54: Dust protected and splash-proof. Not suitable for direct outdoor exposure to rain.
  3. Selection check: Total heat generation inside cabinet, pressure difference between inlet and outlet. Avoid airflow short-circuit when multiple units are mounted in parallel.
  4. Common faults: Airflow reduction caused by clogged filter mat, abnormal noise from bearing wear, fan stop due to unstable voltage. Periodic filter replacement is critical for maintenance.

📦 HS Code Reference (Customs Declaration)

84145990 (Other axial fans, industrial cabinet ventilation fans)

RITTAL SK3201.300 (SK3201300)

참조: SK3201.300|204×204×104mm|Cut-out 177×177mm|AC230V|105m³/h|IP54|RAL7035|Snap-in intake fan filter, 볼 베어링

Replacement Classification: Class A = Direct mechanical interchange (same cut-out, 스냅인 장착); Class B = Similar dimension, minor cut-out/seal modification required; Class C = Economy general type, for non-critical cabinets in projects

상표모델수업깊이주요 차이점애플리케이션
LeizigFK2202.230클래스 A104mmSnap-in structure, RAL7035, foam gasket, 볼 베어링; separate filter mat available. High-end domestic product designed to match original Rittal unitPLC 캐비닛, VFD cabinet, automation main cabinet, preferred recommendation
KAKUFK204230클래스 A104mmSnap-fit, PA66 flame retardant housing; slightly lower noise; matching exhaust filter FK204OUT; Taiwanese brand with large installed base in industrial marketMachine tool electrical cabinet, production line control cabinet, stable replacement option
KuangshunZL804.230클래스 A104mmRittal-style design, RAL7035, complete sealing gasket; 비용 효율적; EC energy-saving version optionalBulk projects for panel builders, standard indoor electrical cabinets
QVKSFK204-230클래스 A104mmQuick-release snap filter mat; direct supply from domestic factory; 경쟁력 있는 가격General control cabinets, non-continuous heavy-duty operation
Generic Chinese Rittal-style (many small manufacturers)FB204.230클래스 C98~105mmLarge tolerance variation; some models use sleeve bearing (짧은 서비스 수명); inconsistent flame retardancy; compatible filter matTemporary retrofits, non-critical auxiliary cabinets. Not recommended for long-term continuous operation

Matching Exhaust Filter (corresponds to Rittal SK3201.200 fanless outlet grille)

상표Exhaust Model비고
LeizigFK2202-OUTSame panel size, filter only without fan
KAKUFK204-OUTRAL7035, 스냅인 장착
KuangshunZL804-OUTFor package procurement together with fan

Replacement Verification Checklist (Engineering Mandatory)

  1. Mounting Interchangeability: Class A units share identical 177×177 cabinet cut-out. Snap-in design enables direct replacement of original SK3201.300 without sheet metal modification. For Class C generic units, verify cut-out tolerance by physical measurement.
  2. Bearing Selection: Ball bearing version preferred. Sleeve bearing has short service life and tends to generate noise under high temperature; not suitable for 24/7 지속적인 작동.
  3. IP54 Prerequisite: Complete foam sealing gasket must be fitted. IP rating will degrade to IP43 without gasket.
  4. Filter Mat Compatibility: Filter mats of Class A brands are interchangeable with Rittal SK3201.000 filter, convenient for spare parts management.
  5. Flame Retardancy & Certificates: Check CE & RoHS for export projects; verify 3C certification for domestic projects. Class C low-cost products often lack valid certificates.
  6. Airflow Derating: Domestic products quote free-blow airflow. Actual airflow will drop under internal cabinet duct resistance. Reserve margin in thermal calculation.

Selection Recommendation Summary

Projects requiring direct replacement, long-term reliability and spare part compatibility: Leizig FK2202.230 / KAKU FK204230

Bulk panel building projects, 비용 우선순위, standard indoor conditions: Kuangshun ZL804.230

낮은 예산, short-term retrofit: FB204.230 (inspect bearing and gasket during acceptance)

위험 경고

Domestic units with identical outer dimension may have minor differences in thickness, gasket protrusion and snap travel. It is recommended to test fit one sample before mass replacement to confirm sealing, snap lock and wiring clearance.

제품특징

  1. Intake fan: External air passes filter mat and blows into cabinet to remove internal heat. Separate SK3201.200 outlet filter required for exhaust to form convection.
  2. IP54 보호: Dust protected and splash-proof, suitable for general industrial workshop environment.
  3. Tool-free snap-fit housing. Easy filter replacement and fan maintenance.
  4. Compatible with Rittal TS, AE, TP standard enclosures; also applicable for retrofitting other brands of electrical cabinets.
  5. Ball bearing design for long continuous runtime and low noise.

예비 부품 & 관련 모델

Replacement filter mat: SK3201.000 (consumable item, replace periodically in dusty environment)

115V version: SK3201.310

Matching exhaust filter (팬이 없는, only exhaust filtration): SK3201.200

일반적인 응용

PLC control cabinet, VFD cabinet, machine tool electrical box, low voltage switchgear, automation line control cabinet, indoor non-explosion-proof service

선택 & 문제 해결

  1. Thermal airflow sizing: Total power dissipation, temperature difference between cabinet inside/outside and duct resistance reduce actual airflow. Do not use nominal 105 m³/h directly for thermal calculation.
  2. Installation suggestion: Mount intake fan at lower section of cabinet; fit exhaust filter at upper section. Take advantage of hot air rising to improve cooling efficiency.
  3. Common faults: Reduced airflow → clogged filter mat; fan fails to start → check AC230V supply; abnormal noise → bearing degradation.
  4. Replacement strategy: Domestic 204-type fan-and-filter units can be mechanically interchanged, but IP rating, fan service life and flame retardancy must be rechecked.

Leizig FK2202.230|Installation Instruction (Replacement for Rittal SK3201.300, Snap-in Embedded)

장착 유형: Embedded snap-in mounting on cabinet sheet metal panel (main housing fixed without screws). Can be fitted on cabinet side panel, door or top plate; Airflow Direction: Outside air → filter mat → fan → blow into cabinet (intake type)

  1. Sheet Metal Cut-out Requirement (Fully compatible with Rittal SK3201.300, no cut-out modification for direct replacement)

Panel cut-out: 177 × 177 mm square

Outer frame dimension: 204 × 204 mm, overall depth 104 mm

Applicable sheet metal thickness: 1.5mm~2.5mm standard Rittal cabinet sheet metal (too thick: snap cannot lock; 너무 얇다: sheet metal prone to deformation)

Deburr cut edge to prevent gasket damage

  1. Step-by-step Installation
  2. Power Isolation Precondition

Disconnect cabinet power supply; confirm no live working. Clean burrs and grease around cut-out.

  1. Pre-installation Inspection

Verify the foam rubber gasket on rear side of unit is intact and undamaged (critical for IP54 protection). Confirm four spring clips are fully open.

  1. Push-in from Cabinet Exterior (Standard Method) ✅

Align FK2202.230 with the 177×177 cut-out from outside of cabinet, press evenly on four corners of panel. Fourclick sounds indicate four spring clips snap and lock onto inner side of sheet metal.

Panel sits flush against cabinet outer surface; gasket is compressed to achieve dust and splash sealing.

  1. Cabinet Internal Wiring (AC220/230V)

Fan comes with terminal block (L live / N neutral / PE earth). Terminate wiring inside cabinet. Miniature circuit breaker is recommended for protection. PE ground wire must be reliably earthed.

  1. Filter Cover Removal for Maintenance

Front louver grille is snap-fit. Pull outwards without tools to remove foam filter mat; clip back after replacement.

  1. Removal Procedure

Pinch four spring clips inward from cabinet interior, push unit outward simultaneously to extract fan.

선택 과목: For rare cases with thin sheet metal or heavy vibration, four M4 self-tapping screws can be added into pre-drilled holes on panel corners for reinforcement (not required by original design; snap fixation is sufficient).

  1. 장착 방향 & Airflow Design Guidelines (Engineering Focus)

FK2202.230 is an intake fan: install at the lower section of cabinet to draw in cool ambient air;

Fit Leizig FK2202-OUT (fanless exhaust filter) at upper cabinet to establish natural thermal convection;

Do NOT invert or mount at top for exhaust. Exhaust operation will burn filter mat and invalidate IP protection.

  1. Installation Acceptance Criteria
  2. No obvious gap around panel; gasket compressed uniformly.
  3. All four clips fully engaged; no wobble when manually shaking unit.
  4. 전원 켜기 테스트: Air blows from outside into cabinet.
  5. No blade rubbing or abnormal noise.
  6. Minor Installation Differences vs Rittal SK3201.300

✅ Same cut-out and snap mechanism, direct replacement without sheet metal modification

⚠️ Two minor differences:

  1. Slightly different spring clip tension; higher pressing force required for 2.5mm thick cabinet sheet metal.
  2. Slight variation in gasket cross-section dimension. Sample test fit is required to verify sealing performance.

이전:

답장을 남겨주세요

메시지를 남겨주세요