매개변수설명
정격전류100에이Maximum current that can be stably carried for a long time
극 수3피 (삼상)Controls three-phase circuits simultaneously
정격전압230/400뷔와Suitable for standard three-phase 380V systems
정격 절연 전압500뷔와최대 절연 내전압
정격 작동 주파수50/60헤르츠Applicable standard power frequency
오염도도 2일반 산업 환경에 적합
기계적 수명1,700 타임스Maximum number of mechanical operation cycles of the switch
전기적 수명15,000 타임스Maximum number of load-carrying operation cycles
보호 등급 (IP 등급)IP20Prevents intrusion of solid foreign objects larger than 12mm
배선 용량맥스. 150mmCross-sectional area of connectable wires
무게대략. 205g (3피)Net weight of the product

  • 제품 세부정보

Schneider EZ7SW-3P100A is an isolating switch with 3 poles and a rated current of 100A. It belongs to Schneider’s Easy 7 series of low-voltage terminal power distribution products and is mainly used in industrial and commercial 배전 시스템.

핵심 기능:

Circuit Isolation: Provides obvious electrical isolation during maintenance or overhaul to ensure personnel safety.

On/off Operation with Load: Can connect and disconnect load circuits below the rated current (it does not have overload and short-circuit protection functions).

전원 스위칭: Used for connection control between the power supply side and the load side.

상세한 기술 매개변수

매개변수설명
정격전류100에이Maximum current that can be stably carried for a long time
극 수3피 (삼상)Controls three-phase circuits simultaneously
정격전압230/400뷔와Suitable for standard three-phase 380V systems
정격 절연 전압500뷔와최대 절연 내전압
정격 작동 주파수50/60헤르츠Applicable standard power frequency
오염도도 2일반 산업 환경에 적합
기계적 수명1,700 타임스Maximum number of mechanical operation cycles of the switch
전기적 수명15,000 타임스Maximum number of load-carrying operation cycles
보호 등급 (IP 등급)IP20Prevents intrusion of solid foreign objects larger than 12mm
배선 용량맥스. 150mmCross-sectional area of connectable wires
무게대략. 205g (3피)Net weight of the product

응용 시나리오

  1. 산업용 배전 시스템

Main power switch for equipment, facilitating safe isolation during maintenance and overhaul.

Isolation protection for motor control circuits.

  1. Commercial Building Power Distribution

Main switch for floor distribution boxes.

Group control for lighting systems.

  1. 주거용 배전

Main incoming switch for villas or multi-storey residences.

Dedicated isolation for large electrical appliances (such as air conditioners and water heaters).

  1. 임시 전원 공급 장치 시나리오

Power control for construction site distribution boxes and mobile equipment.

Differences from Circuit Breakers

Key Differences Between EZ7SW (Isolating Switch) and EZ7 Circuit Breaker:

특징EZ7SW Isolating SwitchEZ7 Circuit Breaker (예를 들어, EZ7-100A)
보호 기능No overload/short-circuit protectionWith dual protection against overload and short-circuit
Arc Extinguishing CapacityLimited, suitable for normal load operationStrong, capable of breaking short-circuit current (6그만큼)
지원 위치Power supply side, used for isolationLoad side, used for protection and control
작동 빈도낮은 (1,700 mechanical life cycles)높은 (10,000 mechanical life cycles)

선택 제안: They are usually used in conjunction. The circuit breaker is responsible for protection, and the isolating switch is responsible for isolation to ensure maintenance safety.

Installation and Usage Guidelines

  1. 설치 요구 사항:

– 수직으로 설치 (경사 ≤ 5°), with the operating handle in the upward position for closing.

Install using standard DIN rails for easy replacement and expansion.

Ensure the installation location has good ventilation, with an ambient temperature of -5℃ ~ +55℃.

  1. 배선사양:

Connect the power supply to the static contacts (upper end) and the load to the moving contacts (lower end).

Tighten with a torque of 3.5Nm (using M7 screws) to ensure good contact.

The cross-sectional area of the wire should be ≤ 150mm² to ensure a secure connection.

  1. 사용시 주의사항:

Breaking with fault is strictly prohibited: Operate only when the load is working normally.

– 유지보수 전, the circuit breaker must be disconnected first, then the isolating switch.

Ensure hands are dry during operation to avoid electric shock risks.

요약

Schneider EZ7SW-3P100A is a reliable industrial-grade isolating switch, specifically designed for 380V three-phase power distribution systems, providing safe isolation and load-carrying operation functions. Although it does not have protection functions, it serves as the “최후의 방어선” for electrical safety and is crucial in maintenance and overhaul processes.

Purchase Tip: If complete protection functions are required, it is recommended to use it with Schneider’s EZ7 series circuit breakers (예를 들어, EZ7-100A) to build a complete power distribution solution of “격리 + 보호”