SICK WL9L-3P2432 Laser Retro-Reflective Photoelectric Sensor - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 SICK WL9L-3P2432 Laser Retro-Reflective Photoelectric Sensor - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

SICK WL9L-3P2432 Laser Retro-Reflective Photoelectric Sensor

Basic Model Information Full Model No.: WL9L-3P2432 Order No.: 1058175 제품 시리즈: W9 Mini Square Photoelectric Sensor Detection Principle: Coaxial Laser Retro-Reflective (with Polarization Filter) 기원: 아픈, Germany Model Code Breakdown WL9L 3 피 2432 WL9L: W9 series, laser light source, retro-reflective type 3: M12 male 4-pin connector P: PNP transistor output 24: 넓은 전압 ...

  • 제품 세부정보

Basic Model Information

전체 모델 번호: WL9L-3P2432

주문번호: 1058175

제품 시리즈: W9 Mini Square 광전 센서

탐지 원리: Coaxial Laser Retro-Reflective (with Polarization Filter)

기원: 아픈, 독일

모델 코드 분석

WL9L 3 피 2432

  1. WL9L: W9 series, laser light source, retro-reflective type
  2. 3: M12 male 4-pin connector
  3. 피: PNP transistor output
  4. 24: Wide voltage supply DC 10~30V
  5. 32: Complementary light-on/dark-on output, single-button teach-in, no IO-Link
  6. Core Optical Parameters
매개변수 항목사양
광원650nm visible red laser, 수업 1 원자 램프 (radiation-safe)
Light Spotφ1mm @ 500mm, ultra-fine spot for tiny workpiece detection
맥스. 감지 범위 (with PL80A reflector)0~12m
Standard Reliable Operating Range0~8m
Polarization Filter내장, suppresses interference from glossy metal reflections
조정 방법Single-button teach-in calibration on housing
  1. 전기적 성능
  2. 전원공급장치: DC 10~30V, 리플 < 5Vpp
  3. Quiescent Current: 30엄마 (무부하)
  4. 산출: Complementary PNP output (switchable light-on / dark-on)
  5. 부하 전류: 100mA 이하; derated to 50mA above 50℃
  6. 응답 시간: ≤0.5ms, switching frequency 1000Hz
  7. Protections: 역극성 보호, 단락 보호, SIRIC® EMI suppression
  8. 유입 방지: IP66 / IP67 / IP69K (high-pressure washable)
  9. 기계적 치수 & 설치

개요: 12.2 (여) × 52.2 (시간) × 23.6 (디) mm

설치: M3 threaded mounting holes on both sides

주택: High-strength VISTAL engineering plastic, PMMA 광학렌즈

무게: 13g

작동 온도: -10℃ ~ +50℃; extended low temp -30℃~+55℃

보관 온도: -30℃ ~ +70℃

  1. M12 4-Pin Pin Assignment (Male Connector)
  2. Pin1: Brown DC24V Positive
  3. Pin2: White Reserved / No external input
  4. Pin3: Blue 0V GND Negative
  5. Pin4: Black PNP Signal Output
  6. 핵심 장점
  7. Ultra-fine Laser Spot: Stable detection of tiny parts, gaps, labels and transparent films
  8. 동축 광학 + Polarizer: Eliminates false triggering from aluminum foil, stainless steel and mirror surfaces
  9. Ultra-long 12m sensing range, enables long-distance installation in compact equipment
  10. IP69K dust & water resistance, suitable for food and washing production lines
  11. Single-button teach-in, one-click matching for reflector and detection threshold
  12. 1kHz high-speed performance, no missing counts on high-speed conveying lines
  13. 기준 & 옵션 액세서리

Reflector not included as standard, separate purchase required: PL80A (standard 80×80 reflector)

옵션 액세서리: L-shaped M3 mounting bracket, REF-AC1000 reflective film, M12 straight/angled connector cables

  1. 일반적인 애플리케이션 시나리오

포장기계: Presence detection of transparent films, small bottle caps and labels

전자 장비: Positioning of miniature PCB components and terminals

Material Handling Conveyors: Counting and in-position detection of cartons and metal bins

Food Processing Lines: Washing stations, metal container identification

공작기계 자동화: Workpiece in-position detection, tiny part presence check

  1. Alternative Models in Same Series
  2. WL9-3P2432: Standard LED retro-reflective, larger spot, 5m range, 저렴한 비용
  3. WL9LG-3P2432: Laser retro-reflective, 4.5m max range, economical short-distance variant
  4. WL9LC-3P2432A00: IO-Link communication supported, remote parameter upload & diagnosis available

설치 완료 & Commissioning Manual for SICK WL9L-3P2432 Laser Retro-Reflective Photoelectric Sensor

Document Basic Information

모델: WL9L-3P2432|Order No.: 1058175

제품 시리즈: W9L Coaxial Laser Retro-Reflective Photoelectric Sensor

적용 가능한 표준: IEC60825-1 (수업 1 Safe Laser), IP67/IP69K, CE, UL

Manual Coverage: Mechanical mounting, electrical wiring, teach-in calibration, 문제 해결, safety specifications

  1. Mandatory Pre-Installation Safety Regulations
  2. 레이저 안전

This product is Class 1 원자 램프; no eye hazards under normal operation. Do not disassemble optical components; do not view laser spot directly through magnifying lenses.

  1. 전기 안전

Disconnect DC24V power supply before wiring or disassembly. Only DC10~30V power permitted; AC220V input is strictly prohibited.

  1. Functional Safety Limitation

Not designed for safety circuits such as machine safety gates or emergency stop protection; only for standard presence detection and counting.

  1. 환경 제한

Avoid direct intense sunlight, welding arc light, continuous oil mist spray, and heavy vibration equipment. 진동 >10g requires shock-absorbing brackets.

  1. Mechanical Mounting Section

2.1 Outline Dimensions (폭×높이×깊이)

12.2 mm × 52.2 mm × 23.6 mm, M3 through holes on both sides (hole diameter 3.1mm)

2.2 List of Separate Purchase Mounting Accessories

  1. 장착 브래킷: BEF-WN-W9-2 (Universal L-shaped galvanized steel bracket)
  2. Standard Reflector: PL80A (80×80mm, standard for 0~12m); PL40A optional for short range
  3. 케이블: M12 4-pin straight / angled cables YF2A14 (2m/5m/10m lengths)

2.3 장착 절차

  1. Fix the bracket onto rigid machine frame; M3 screw torque 0.6~0.8N·m, do not over-tighten to avoid cracking housing.
  2. Install sensor into bracket with adjustable angle; lock screws firmly to eliminate shaking.
  3. Key Rules for Reflector Installation (비판적인)

Reflector surface must be perpendicular to sensor laser optical axis, tilt angle ≤3°; signal loss occurs if tilt >5°

Mount reflector on flat, vibration-free metal plate; do not attach to soft plastic or sponge

Laser spot must fall within the central area of reflector; edge reflection reduces sensing range

  1. Range Specifications

Absolute Max. 범위: 12중 (with PL80A)

Stable Reliable Operating Zone: 0~8m (engineer recommended range)

Minimum Blind Zone: 0중 (coaxial optics eliminates near-range blind zone)

2.4 Mounting Pitfall Prevention

Reserve ≥10mm clearance on both sides of optical path to avoid workpiece or bracket blocking laser beam;

Built-in polarization filter must be utilized for metallic mirror workpieces and aluminum foil packages; avoid overlapping reflections from reflector and target parts;

For food washing stations with IP69K requirement, mount lens facing downward to reduce water and dust accumulation.

  1. Electrical Wiring Specifications

3.1 M12 Male 4-Pin Assignment (Standard Brown/White/Black/Blue Wire Color)

핀번호.와이어 색상기능설명
Pin1갈색DC24V+Positive power supply DC10~30V
Pin2하얀색Reserved Unused PinNo input function on this model; leave unconnected
Pin3파란색0V/GND전력 네거티브 & common signal ground
Pin4검은색Complementary PNP OutputSwitchable light-on/dark-on, max load 100mA

3.2 Wiring Construction Standards

  1. 케이블 선택: PVC shielded/unshielded sensor cable, wire cross-section 0.34~0.5mm²;
  2. Wiring Separation: Maintain ≥30cm clearance between power cables (인버터, 모터) and sensor signal cables; cross wires perpendicularly when necessary;
  3. Shield Grounding: Shield layer single-point grounding only at control cabinet side; leave shield ungrounded at sensor end;
  4. 출력 부하: PNP output connects to positive terminal of PLC input module; load current ≤100mA; do not drive solenoid valves directly.

3.3 Electrical Protection Features

Built-in reverse polarity protection, output short-circuit protection, 서지 억제; peak supply ripple ≤5Vpp.

  1. Power-On Teach-In Calibration Operation (Single-Button Teach-In)

4.1 Indicator Light Description

Green LED: Power indicator, steady on = normal power supply; off = power cut / 단락

노란색 LED: Signal indicator, on = reflected laser received; off = beam blocked

4.2 Standard Teach-In Procedure (Factory Default: Light-On)

  1. Power on, ensure laser beam hits reflector fully, yellow LED stays lit;
  2. No workpiece (beam unobstructed): Press and hold teach button on housing for 2s, 녹색 & yellow LEDs flash once synchronously to save reference baseline;
  3. Place detection workpiece (beam blocked): Press and hold teach button another 2s, both LEDs flash twice to complete teach-in;
  4. Release button and test: Yellow LED off with workpiece present, yellow LED on without workpiece (Light-On mode).

4.3 Switch to Dark-On Mode

After standard teach-in, hold button for 5s; 녹색 & yellow LEDs flash rapidly 3 타임스, output switches to Dark-On: yellow LED on and output energized when workpiece is present.

4.4 Restore Factory Default Settings

Hold teach button continuously for 10s; all LEDs flash consecutively, all parameters reset to factory state (Light-On, standard sensitivity).

  1. Commissioning Acceptance Criteria
  2. No load (no workpiece): Green LED steady on, yellow LED stable on, no input signal to PLC;
  3. Beam blocked (workpiece in position): Green LED steady on, yellow LED off, consistent signal received by PLC;
  4. Continuous Operation Test: 30min uninterrupted conveyor running without false triggering or missing detections;
  5. Limit Condition Test: Stable triggering at 8m maximum operating range and slight dusty environment.
  6. 환경 & 기계 사양
  7. 작동 온도: -10℃ ~ +50℃; short-term low temp -30℃ (performance degradation occurs)
  8. 유입 방지: IP66, IP67, IP69K (80℃ high-pressure wash available)
  9. 하우징 재질: High-strength VISTAL plastic, resistant to cutting fluid, weak acid and alkali
  10. 응답 시간: ≤0.5ms, switching frequency 1000Hz, compatible with high-speed conveying lines
  11. Spot Specification: φ1mm @ 500mm, high-precision detection for tiny parts and labels
  12. Troubleshooting Matrix for Common Faults
결함 현상근본 원인Solution Steps
Green LED off, no response at allReverse power supply / insufficient voltage / 끊어진 케이블1. Measure voltage between Pin1-Pin3 with multimeter (10~30V); 2. Verify brown & blue wiring; 3. Replace M12 connector
Green LED on permanently, yellow LED never lightsLaser misaligned with reflector / dirty reflector / distance exceeds 12m1. Realign optical axis perpendicular to reflector; 2. Wipe lens and reflector; 3. Shorten mounting distance within 8m
Yellow LED flickers without workpiece, frequent false triggersAmbient stray light, metal surface reflection, excessive sensitivity1. 차광막을 설치하세요; 2. Re-teach to reduce sensitivity; 3. Replace with polarization-specific reflector
No signal output when workpiece passes (missed detection)Incorrect teach-in threshold, laser spot offset from workpiece1. Complete full two-step teach-in again; 2. Adjust sensor height to fully block laser beam with workpiece
Intermittent output signalLoose bracket, cable tension, 커넥터에 물 유입1. 장착 나사를 조이세요; 2. Add cable fixing clips; 3. Dry connector and wrap with waterproof tape
  1. Maintenance Specifications
  2. 일일점검: Wipe dust and oil from sensor lens and reflector with lint-free cloth + anhydrous ethanol;
  3. Weekly Inspection: Check bracket screws and M12 connectors for looseness or water stains;
  4. Annual Calibration: Re-run teach-in procedure to eliminate sensitivity drift caused by dust accumulation;
  5. 금지된 작업: Do not scratch optical lens with hard objects; do not sharply bend M12 connector cables.
  6. Notes on Alternative & Matching Part Selection
  7. Short-Range Alternative: WL9LG-3P2432 (max 4.5m laser retro-reflective)
  8. IO-Link Communication Version: WL9LC-3P2432A00 (supports remote parameter reading & 진단)
  9. Reflector Selection: PL80A preferred for long distance; REF-AC1000 reflective film for narrow confined spaces

Operating Principle of SICK WL9L-3P2432

  1. Sensor Type Definition

WL9L-3P2432 is a coaxial laser polarized retro-reflective photoelectric sensor. Core components: 650nm red laser diode, coaxial beam splitting optics, polarization filter, receiving photodiode, signal processing circuit, PNP output unit.

  1. Core Optical Principle: 동축 광학 (Key Difference from Standard Retro-Reflective Sensors)
  2. Transmitter Side

Internal laser diode emits ultra-fine parallel laser beam (1mm spot at 500mm). Beam passes through a transmitting polarizer to output linearly polarized laser with single polarization direction.

  1. Coaxial Optical Design

Transmitting and receiving optical paths share one lens. Laser beam emits from sensor center, reflected light returns along identical optical path back to lens, eliminating detection blind zone. Separated standard retro-reflective sensors have near-range blind zones, while this model achieves stable detection at 0m.

  1. Reflector Reflection Characteristic

Matched PL80A reflector adopts retroreflective structure: light returns parallel to incident direction even with minor angular offset; meanwhile the reflector changes laser polarization angle.

  1. Polarization Screening at Receiver Side

Orthogonal polarization filter integrated inside lens:

Light reflected from reflector: polarization angle shifted, penetrates receiving polarizer, photodiode receives optical signal;

Stray light directly reflected from metal, aluminum foil or mirror targets: unchanged polarization angle, fully blocked by polarizer to avoid false triggering.

> This is the core principle enabling stable detection of glossy metal and film-wrapped packages.

  1. Complete Detection Workflow (Two States: Workpiece Present / Absent)

State 1: No Workpiece (Optical Path Unobstructed)

  1. Laser beam emits → hits reflector and reflects back along original path;
  2. Reflected light passes polarization filter and reaches receiving photoelectric element;
  3. Photodiode generates current signal, internal amplifier circuit identifiesreturn light received”;
  4. Circuit outputs corresponding voltage level:

Light-On Mode: PNP output energized (24V output);

Dark-On Mode: PNP output de-energized.

  1. Yellow signal LED on housing stays steady lit.

State 2: Workpiece Blocks Optical Path

  1. Workpiece cuts laser beam, no light returns to sensor;
  2. No input signal to receiving photodiode;
  3. Internal circuit judgesno return light”, flips output voltage level;
  4. Yellow signal LED turns off.
  5. Threshold Adjustment Principle via Single-Button Teach-In

Sensor built-in microcontroller stores two reference light intensity values through single-button teach-in:

  1. Maximum received light intensity with unobstructed optical path (reflected by reflector);
  2. Minimum received light intensity under full beam blockage;

MCU automatically calculates intermediate threshold to distinguishlight present / light absent”, adapting to dusty environments and minor light attenuation to prevent abnormal operation.

  1. Electrical Output Conversion Principle
  2. Powered by DC10~30V; internal voltage regulator supplies power to laser diode and processing chip;
  3. Analog photoelectric signal amplified, converted to digital signal via ADC and transmitted to MCU;
  4. MCU compares light intensity against threshold and drives PNP transistor output;
  5. Black wire Pin4 is PNP output: output ≈ supply voltage 24V when energized, max load 100mA; built-in short-circuit and reverse polarity protection circuits.
  6. Summary of Principles Corresponding to Key Technical Advantages
  7. Ultra-fine Laser Spot: Collimated laser source prevents spot diffusion over long distance, suitable for tiny part and gap detection;
  8. Polarization Anti-Interference: Orthogonal polarization optics eliminates false detection from stainless steel and aluminum foil mirror reflections;
  9. Coaxial Zero Blind Zone: Shared transmit-receive optical axis enables stable detection at 0m close range;
  10. High-Speed Response ≤0.5ms: Fast laser response matched with high-speed processing chip, 1kHz switching frequency fits high-speed production lines.
  11. Simplified Plain-Language Operating Principle

The sensor emits thin polarized laser beam; the opposite reflector bounces light back along the original path. Internal polarizing lens only accepts reflected light from the reflector. When a workpiece blocks the laser, no signal is received. Internal circuit switches high/low PNP output voltage levels to transmitmaterial present / absentsignal to PLC.

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요