상태: Discontinued by original manufacturer, Class 10E, S6 frame, electronic motor protection relay
기본사양
주문번호: 3RB2056-1FC2
현재 설정 범위: 50 … 200 에이
프레임 크기: S6 (compatible with S6 contactors such as 3RT1056)
여행 클래스: Class 10E (결정된, 조정 불가능)
Matched motor power at 400V 50Hz: 30~90kW
주회로 연결: 부스바 연결
보조 회로: 나사 터미널, auxiliary contacts 1NO + 1NC
재설정 모드: 수동 / automatic reset selectable
설치: Direct snap-on to S6 contactor or standalone mounting
보호 등급: IP20
정격 절연 전압: 1000뷔와, 전류 내전압 8kV
주파수 범위: 50/60헤르츠
작동 온도: -25℃ ~ +60℃
보호 기능
전자식, different from bimetallic thermal relays:
Inverse-time overload protection
위상 손실 / 위상 불균형 보호
Motor stall protection
Built-in test button for loop testing
모델 구별 (Easily Confused Models in the Same Series)
3RB2056-1FC2: Class10E, 단종
3RB2056-2FC2 / 2FX2: Class20E, heavy-duty start version, 가장 일반적인 교체
Replacement Selection Suggestions
- 동일 사양으로 직접 교체: 3RB2056-2FC2 (Class20E); if Class10 is strictly required, prioritize the new generation 3RB3056 series electronic overload relay
- Matching contactor: 지멘스 3RT1056 (S6)
- 국내 대안: Domestic electronic thermal relay with 50-200A, S6 footprint, 1아니요+1NC, 클래스10
주요 내용
3RB2056-1FC2 is an older imported 3RB2 model, discontinued by Siemens. Stock units are only available from inventory. New projects are generally recommended to adopt the new 3RB30 series.
3RB2056-1FC2 (S6 / 50-200에이 / Class10E) 배선 & 시운전 매뉴얼
비고: Electronic type requiring auxiliary power supply A1/A2; main circuit adopts busbar connection (S6, matched with 3RT1056 contactor), not through-core type; 콘택트 렌즈: 95-96 (NC 상시 폐쇄), 97-98 (NO 평상시 열림), 1아니요+1NC
- 터미널 정의
A1, A2: Auxiliary power supply terminals (AC/DC 24V or 110~240V, depending on sub-version). The 3RB20 draws power here. The electronic relay must be powered up for phase loss/unbalance protection to work.
95, 96: 상시 폐쇄 접점 (NC) → Standard usage: wired in series into the contactor coil control circuit to cut off and stop the motor on overload trip
97, 98: 상시 개방 접점 (아니요) → For fault alarm, PLC fault input or fault indicator light
주회로: Upper busbar connects to contactor output, lower busbar connects to motor (L1/L2/L3 straight through. The thermal relay does not break the main circuit, only the control circuit)
전면 패널: Current adjustment knob (50-200에이), M/A DIP switch (수동 / auto reset), TEST test button, RESET reset button
- 표준 배선 다이어그램 (Direct-On-Line Start Circuit)
1) 주회로
3-phase power supply → Circuit breaker → 3RT1056 (S6 contactor) → 3RB2056-1FC2 busbar input → 3RB busbar output → Motor
2) 보조 회로
- A1/A2: Connected to control power supply (to power the electronic board of thermal relay)
- 접촉기 코일 회로: Power supply → Stop button → Start button (자동 잠금) → 95-96 (NC) → Contactor coil → Power supply neutral
- Fault signal: 97-98 parallel to fault indicator or PLC DI point
중요한: 95-96 is the protection series contact, opens on trip; 97-98 closes synchronously to output fault signal
3) 독립형 장착 (Not clipped onto contactor)
Main circuit remains busbar connection, auxiliary terminals unchanged, fixed separately on backplate. A1/A2 must be powered.
메모: 3RB20 has no A3/A4 remote reset terminals (remote reset is available on 3RB21 only). Only local panel reset or automatic reset is supported.
- 중 / A Reset DIP Switch
M = Manual Reset (Recommended for safety circuits) : After overload / phase loss trip, the RESET button on panel must be pressed to reset; no automatic restart
A = Auto Reset : Automatically resets after approx. 3 minutes delay after tripping, suitable for low-risk fans with unattended operation; A mode is strictly prohibited for equipment with entanglement hazard
- Complete Commissioning Procedure (Before Power-on → No-load → On-load)
단계 1: Pre-power Check (전원 끄기)
- Check rated current on motor nameplate, set the current knob to motor rated current (즉)
예: Motor rated 88A → Align knob at 88A; do not set directly to 200A
Range 50-200A, Class10E fixed and non-adjustable
- Set M/A DIP switch per process requirement (M is default)
- Check tightening torque of busbar bolts, no loose 3-phase busbar connections; secure auxiliary terminal screws
- 멀티미터를 이용한 연속성 테스트: 95-96 conducting normally; 97-98 open normally
단계 2: Power on Auxiliary Supply and Test Functions (No High Voltage on Main Circuit!)
- Supply power only to A1/A2, no 380V on main circuit
- 누르다 [시험] 단추:
95-96 열립니다, 97-98 closes → Contact action normal
Release TEST and press RESET to restore normal state
TEST only simulates contact action, does not simulate real overload current, it is a loop verification
- 테스트 재설정: For M mode, RESET button must be pressed to restore after test; for A mode wait for auto reset (M mode is used during commissioning generally)
단계 3: Energize Main Circuit and No-load Test Run
- Close main circuit, start motor for no-load operation
- Measure 3-phase no-load current with clamp meter and record; confirm no severe unbalance
- If 3-phase current deviation>20%, check motor, wiring and power supply first. The electronic relay will trip for phase loss/unbalance protection directly
단계 4: On-load Operation and Current Verification (비판적인)
- After motor runs stably at rated load, measure 3-phase operating current with clamp meter
- If steady operating current is 70A, set the knob to 70A;
- Pay attention not to run below the lower limit of the range if starting inrush current is high and rated current is near 50A lower limit;
Definition of Class10E: Trips within 10s at 7.2 시간 정격 전류, suitable for standard motors; not suitable for heavy-duty long-start applications (use 3RB2056-2FC2 Class20E for heavy duty)
단계 5: Fault Simulation and Acceptance
- Cut off one phase (power off before operation), energize and verify: thermal relay triggers phase loss protection, 95-96 opens to stop motor
- 기록: setting current, 재설정 모드, trip logs
- Acceptance criteria: 초과 적재, phase loss and phase unbalance trigger reliable tripping; self-locking circuit and fault signal output normal
- Quick Fault Troubleshooting
- 과부하시 트립 없음: ① A1/A2 no power supply (no supply = no protection for electronic relay); ② setting current too high; ③ TEST button failure
- Trip immediately upon energizing: 심각한 3상 불균형, 모터 권선 단락, setting current too low
- Cannot auto reset after trip: DIP switch at M (정상); if switch at A and still no auto reset, device aging
- Normal no-load, trips frequently under load: 모터 과부하, bearing jam, large supply voltage drop, setting current too low
- Important Safety Reminders
This is an electronic thermal relay. Protection fails if A1/A2 power is lost! This differs fundamentally from traditional bimetallic 3RU thermal relays
S6 busbar requires strict tightening torque. Poor contact causes heating and false tripping
Automatic reset mode A is forbidden for safety-critical equipment (컨베이어, 믹서)
- Matching Replacement Reference
Same frame Class10: New generation 3RB3056
Same frame Class20: 3RB2056-2FC2 (heavy-duty start)
3RB2056-1FC2 (S6 / 50-200에이 / Class10E) 결함 & 솔루션
Pre-reminder: Electronic relay loses all protection without A1/A2 supply, different from traditional bimetallic 3RU. No fault indicator LEDs. Troubleshooting relies on TEST button, multimeter and clamp meter.
잘못 1: No trip when motor is overloaded (Protection failure)
징후: Motor overheats obviously, 95-96 contacts of thermal relay do not act and motor does not stop
원인 1: A1/A2 auxiliary supply lost, wrong voltage or loose terminals (Most frequent)
치료: Measure A1/A2 voltage; verify supply specification; tighten auxiliary terminals. Continuous power supply is required for current detection
원인 2: Current knob set far higher than motor rated current
치료: Reset to motor rated current per nameplate, verify with clamp meter under operation
원인 3: Loose main busbar bolts, poor contact and abnormal internal sampling
치료: 전원 끄기, tighten 3-phase busbar to S6 specified torque; check busbar for oxidation and discoloration from heat
원인 4: Internal sampling board damaged or component aging (High risk for discontinued stock units)
치료: Run TEST test. If 95-96 does not switch when TEST pressed → relay damaged, 직접 교체
잘못 2: Normal no-load, frequent tripping under load (거짓 트립)
징후: Starts fine without load, trips shortly after loading, 95-96 열립니다
원인 1: 전류를 너무 낮게 설정함; Class10E trips fast, not fit for heavy-duty long-start motors
치료: 모터 정격 전류 확인; use 3RB2056-2FC2 (Class20E) for heavy starting applications
원인 2: 3-위상 전류 불균형, 위상 손실, burnt contactor contacts
치료: Measure 3-phase currents with clamp meter; trip triggered if deviation>20%; check upstream contactor and power supply
원인 3: Loose busbar generates heat and sampling drift causes false overload judgement
치료: Stop equipment, check busbar temperature and oxidation, 다시 조이다
원인 4: 주위온도 60℃ 이상, 열악한 캐비닛 환기
치료: 냉각 개선; reserve current margin for high-temperature environments
잘못 3: Immediate trip when energizing / 시작 (Trip on switch-on)
징후: Thermal relay trips as soon as main circuit is energized before motor rotates
원인 1: Motor winding short circuit, insulation failure, mechanical seizure or stall
치료: Disconnect motor, test insulation with megger; check bearing by hand rotation
원인 2: Interference on A1/A2 supply, large control voltage fluctuation
치료: Add filter on control supply; separate supply from variable frequency drives and large contactors
원인 3: DIP switch at A auto reset, fault still present and re-trips immediately after closing
치료: Switch to M manual reset, eliminate root fault before re-energizing, avoid repeated trial switching
잘못 4: 트립 후에는 재설정할 수 없습니다. (RESET button ineffective)
징후: After protection triggers, 95-96 cannot restore conduction even after pressing RESET
원인 1: Root fault persists (지속적인 과부하, 위상 손실, 발작) so protection latches
치료: Cut main circuit, eliminate load fault then reset
원인 2: DIP switch at M manual reset but A1/A2 supply drops
치료: Reset only with stable A1/A2 supply; reset not possible when power is lost
원인 3: 내부 기계적 걸림, contact welding or electronic board latch-up
치료: Power off and rest for 5 minutes and retry; if still fails TEST test, 장치 교체
보충: 3RB20 has no remote reset terminals. Remote reset is available only on 3RB21. Do not add external remote reset wiring.
잘못 5: Auto reset mode A fails to reset automatically
징후: Set to auto reset, no recovery after long waiting post trip
원인 1: A1/A2 auxiliary supply interrupted, auto-reset timer stops when power is lost
치료: Keep A1/A2 continuously powered
원인 2: Fault remains active (persistent overload, 위상 손실), protection stays latched and will not reset
치료: Root fault must be cleared first
원인 3: Unit aging, auto-reset timing circuit failure
치료: Change to M manual reset; replace if auto reset is mandatory
잘못 6: TEST button no response (Contacts do not switch on TEST press)
징후: Only A1/A2 powered, 95-96 remains closed and 97-98 stays open when TEST pressed
원인 1: A1/A2 no power supply or mismatched voltage
치료: Measure auxiliary supply voltage
원인 2: TEST button mechanically jammed or internal electronic board damaged
치료: Power off and clean; replace relay if still invalid
TEST only verifies auxiliary contact loop, does not simulate real overload current. Passing TEST only confirms contact loop works, not current sampling.
잘못 7: No fault signal output from 97-98 after trip (PLC no fault feedback)
징후: Motor stops after trip but NO fault signal output
원인 1: Loose wiring or broken wire on 97-98 터미널
치료: Measure continuity of 97-98 under tripped state
원인 2: Insufficient contact rating, voltage drop when driving low-power PLC DI
치료: Confirm contact load rating; add intermediate relay if required
원인 3: Internal auxiliary contact burnt and damaged
치료: Run TEST test; replace relay if 97-98 does not close
잘못 8: Random intermittent tripping during operation
징후: Current reading normal, trips irregularly
원인 1: Intermittent loose connection on busbar or auxiliary terminals (진동, thermal expansion)
치료: Retighten all terminals and check cabinet vibration
원인 2: Control supply fluctuation and harmonic interference (common with VFD circuits)
치료: Add isolation on control loop; this model is not recommended directly on VFD output, dedicated motor protection relay preferred
원인 3: Unit aging, sampling circuit drift (Common for old discontinued stock)
치료: 릴레이 교체, prefer 3RB30 new generation
잘못 9: Relay latches to trip immediately after auxiliary power on, motor not energized
징후: 380V main circuit not powered, 95-96 opens right after A1/A2 supply is switched on
원인: Internal electronic board failure, damaged sampling circuit
치료: Replace overload relay
Standard Field Troubleshooting Flow
- Confirm A1/A2 auxiliary power supply normal (First check for electronic relay)
- Trigger TEST button to verify contact operation
- Measure 3-phase operating current with clamp meter and cross-check setting value
- Inspect 3-phase voltage, contactor contacts, motor insulation and busbar tightness
- Confirm M/A reset mode matches process requirements
- If all above checks pass and fault persists → Relay internal damage
Critical Pitfall Notes
- Not recommended for direct use on VFD output side; harmonics cause false detection
- Auto reset mode A must not be used long-term on safety equipment (컨베이어, 믹서)
- 이 모델은 단종되었습니다; inventory spares suffer higher electronic board aging risk than newer 3RB30 series
- S6 busbar loose torque causes continuous heating and sampling drift false tripping
SIRIUS 3RB2 Electronic Overload Relay Series Overview
Series includes: 3RB20 (표준 버전, no remote reset), 3RB21 (Enhanced version with remote reset terminals); All discontinued by OEM, only spare stock available. Electronic type requiring A1/A2 auxiliary supply; 보호: 초과 적재, 위상 손실, 위상 불균형, 마구간; Standard contacts 1NO+1NC; 주회로 버스바 연결; Frame sizes S6 / S10 / S12; Current range 50~820A
모델 코드 정의 (3RB2 □ □□ □□□)
3RB20: 기본 버전, no remote reset (3RB2056-1FC2 belongs here)
3RB21: 향상된 버전, with remote reset terminals A3/A4
5th-6th digits: 56=S6 (50-200에이); 66=S10/S12 (55-630에이)
접두사 1 = Class10E; 접두사 2 = Class20E (heavy-duty start)
접미사:
FC2: 나사 터미널, direct snap-on to contactor
FF2: 독립형 장착, 나사 터미널
FW2: 스프링 터미널, snap-on
FX2: 스프링 터미널 + standalone mounting
GC2 / GF2 / MC2 / MF2: S10/S12 specifications
- 3RB20 Series List (No Remote Reset)
| 주문 번호. | 현재 범위 | 액자 | 여행 클래스 | 일치하는 접촉기 | 비고 |
| 3RB2056-1FC2 | 50-200A | S6 | Class10E | 3RT1056 | Snap-on, 나사 터미널, main subject, 단종 |
| 3RB2056-1FF2 | 50-200A | S6 | Class10E | 3RT1056 | 독립형, 나사 터미널 |
| 3RB2056-1FW2 | 50-200A | S6 | Class10E | 3RT1056 | Snap-on, 스프링 터미널 |
| 3RB2056-1FX2 | 50-200A | S6 | Class10E | 3RT1056 | 독립형, 스프링 터미널 |
| 3RB2056-2FC2 | 50-200A | S6 | Class20E | 3RT1056 | Heavy-duty snap-on, 나사 터미널, popular replacement |
| 3RB2056-2FF2 | 50-200A | S6 | Class20E | 3RT1056 | Heavy-duty standalone, 나사 터미널 |
| 3RB2056-2FW2 | 50-200A | S6 | Class20E | 3RT1056 | Heavy-duty snap-on, 스프링 터미널 |
| 3RB2056-2FX2 | 50-200A | S6 | Class20E | 3RT1056 | Heavy-duty standalone, 스프링 터미널 |
| 3RB2066-1GC2 | 55-250A | S10 | Class10E | 3RT1065 | Snap-on, 나사 터미널 |
| 3RB2066-1GF2 | 55-250A | S10 | Class10E | 3RT1065 | 독립형, 나사 터미널 |
| 3RB2066-1MC2 | 160-630A | S12 | Class10E | 3RT1066 | Snap-on, 나사 터미널 |
| 3RB2066-1MF2 | 160-630A | S12 | Class10E | 3RT1066 | 독립형, 나사 터미널 |
| 3RB2066-2GC2 | 55-250A | S10 | Class20E | 3RT1065 | Heavy-duty snap-on, 나사 터미널 |
| 3RB2066-2GF2 | 55-250A | S10 | Class20E | 3RT1065 | Heavy-duty standalone, 나사 터미널 |
| 3RB2066-2MC2 | 160-630A | S12 | Class20E | 3RT1066 | Heavy-duty snap-on, 나사 터미널 |
| 3RB2066-2MF2 | 160-630A | S12 | Class20E | 3RT1066 | Heavy-duty standalone, 나사 터미널 |
| 3RB2011 + 3UF18 | 630–820A | S14 | Class10E | 3TF68/3TF69 | CT combination solution |
- 3RB21 Series List (With Remote Reset A3/A4)
Suitable for PLC remote reset; protection functions and current ranges same as 3RB20
| 3RB2156-1FC2 | 50-200에이 | S6 | Class10E | Remote reset, snap-on, 나사 터미널 |
| 3RB2156-1FF2 | 50-200에이 | S6 | Class10E | Remote reset, 독립형, 나사 터미널 |
| 3RB2156-2FC2 | 50-200에이 | S6 | Class20E | 헤비 듀티 + 원격 재설정 |
| 3RB2166-1GC2 | 55-250에이 | S10 | Class10E | S10 remote reset |
| 3RB2166-1MC2 | 160-630에이 | S12 | Class10E | S12 remote reset |
| 3RB2166-2GC2 | 55-250에이 | S10 | Class20E | S10 heavy duty + 원격 재설정 |
| 3RB2166-2MC2 | 160-630에이 | S12 | Class20E | S12 heavy duty + 원격 재설정 |
| 3RB2111 + 3UF18 | 630-820에이 | S14 | Class10E | CT combination, 원격 재설정 |
- Common Series Parameters
- Auxiliary supply: A1/A2, AC/DC 24V or AC110~240V (depends on sub-version). Protection fails when supply is lost
- 보조 접점: 95-96 (NC), 97-98 (아니요), 1아니요+1NC, 5등급
- 다시 놓기: M/A DIP switch (수동 / auto reset); 3RB21 adds A3/A4 remote reset
- 보호 등급: IP20; Insulation voltage 1000V AC, 전류 내전압 8kV; Operating temperature -25~+60℃
- 주회로: 부스바 연결, not through-core CT type
- 애플리케이션: Standard 3-phase asynchronous motors; Not recommended directly on VFD output; harmonics cause false tripping
- New Generation Replacement Series (새로운 프로젝트에 권장)
S6 50-200A replacement: 3RB3056 (새로운 세대, 더 나은 안정성, active supply)
S10/S12 high-current: 3RB3066 for equivalent replacement
- 빠른 선택 가이드
No remote reset required → 3RB20
PLC remote reset required → 3RB21
표준 팬, 슬리퍼, smooth start → Class10E (접두사 1)
벨트 컨베이어, 파쇄기, heavy-duty long start → Class20E (접두사 2)
Snap-on mounting with contactor → FC2 / GC2 / MC2
Separate backplate mounting → FF2 / GF2 / MF2