Siemens 3RB2056-1FC2 Electronic Overload Relay

상태: Discontinued by original manufacturer, Class 10E, S6 frame, electronic motor protection relay Basic Specifications Order No.: 3RB2056-1FC2 Current setting range: 50 … 200 A Frame size: S6 (compatible with S6 contactors such as 3RT1056) 여행 클래스: Class 10E (결정된, 조정 불가능) Matched motor power at 400V 50Hz: 30~90 kW Main circuit connection: Busbar connection Auxiliary ...

  • 제품 세부정보

상태: Discontinued by original manufacturer, Class 10E, S6 frame, electronic motor protection relay

기본사양

주문번호: 3RB2056-1FC2

현재 설정 범위: 50 … 200 에이

프레임 크기: S6 (compatible with S6 contactors such as 3RT1056)

여행 클래스: Class 10E (결정된, 조정 불가능)

Matched motor power at 400V 50Hz: 30~90kW

주회로 연결: 부스바 연결

보조 회로: 나사 터미널, auxiliary contacts 1NO + 1NC

재설정 모드: 수동 / automatic reset selectable

설치: Direct snap-on to S6 contactor or standalone mounting

보호 등급: IP20

정격 절연 전압: 1000뷔와, 전류 내전압 8kV

주파수 범위: 50/60헤르츠

작동 온도: -25℃ ~ +60℃

보호 기능

전자식, different from bimetallic thermal relays:

Inverse-time overload protection

위상 손실 / 위상 불균형 보호

Motor stall protection

Built-in test button for loop testing

모델 구별 (Easily Confused Models in the Same Series)

3RB2056-1FC2: Class10E, 단종

3RB2056-2FC2 / 2FX2: Class20E, heavy-duty start version, 가장 일반적인 교체

Replacement Selection Suggestions

  1. 동일 사양으로 직접 교체: 3RB2056-2FC2 (Class20E); if Class10 is strictly required, prioritize the new generation 3RB3056 series electronic overload relay
  2. Matching contactor: 지멘스 3RT1056 (S6)
  3. 국내 대안: Domestic electronic thermal relay with 50-200A, S6 footprint, 1아니요+1NC, 클래스10

주요 내용

3RB2056-1FC2 is an older imported 3RB2 model, discontinued by Siemens. Stock units are only available from inventory. New projects are generally recommended to adopt the new 3RB30 series.

3RB2056-1FC2 (S6 / 50-200에이 / Class10E) 배선 & 시운전 매뉴얼

비고: Electronic type requiring auxiliary power supply A1/A2; main circuit adopts busbar connection (S6, matched with 3RT1056 contactor), not through-core type; 콘택트 렌즈: 95-96 (NC 상시 폐쇄), 97-98 (NO 평상시 열림), 1아니요+1NC

  1. 터미널 정의

A1, A2: Auxiliary power supply terminals (AC/DC 24V or 110~240V, depending on sub-version). The 3RB20 draws power here. The electronic relay must be powered up for phase loss/unbalance protection to work.

95, 96: 상시 폐쇄 접점 (NC) → Standard usage: wired in series into the contactor coil control circuit to cut off and stop the motor on overload trip

97, 98: 상시 개방 접점 (아니요) → For fault alarm, PLC fault input or fault indicator light

주회로: Upper busbar connects to contactor output, lower busbar connects to motor (L1/L2/L3 straight through. The thermal relay does not break the main circuit, only the control circuit)

전면 패널: Current adjustment knob (50-200에이), M/A DIP switch (수동 / auto reset), TEST test button, RESET reset button

  1. 표준 배선 다이어그램 (Direct-On-Line Start Circuit)

1) 주회로

3-phase power supply → Circuit breaker → 3RT1056 (S6 contactor) → 3RB2056-1FC2 busbar input → 3RB busbar output → Motor

2) 보조 회로

  1. A1/A2: Connected to control power supply (to power the electronic board of thermal relay)
  2. 접촉기 코일 회로: Power supply → Stop button → Start button (자동 잠금) → 95-96 (NC) → Contactor coil → Power supply neutral
  3. Fault signal: 97-98 parallel to fault indicator or PLC DI point

중요한: 95-96 is the protection series contact, opens on trip; 97-98 closes synchronously to output fault signal

3) 독립형 장착 (Not clipped onto contactor)

Main circuit remains busbar connection, auxiliary terminals unchanged, fixed separately on backplate. A1/A2 must be powered.

메모: 3RB20 has no A3/A4 remote reset terminals (remote reset is available on 3RB21 only). Only local panel reset or automatic reset is supported.

  1. 중 / A Reset DIP Switch

M = Manual Reset (Recommended for safety circuits) : After overload / phase loss trip, the RESET button on panel must be pressed to reset; no automatic restart

A = Auto Reset : Automatically resets after approx. 3 minutes delay after tripping, suitable for low-risk fans with unattended operation; A mode is strictly prohibited for equipment with entanglement hazard

  1. Complete Commissioning Procedure (Before Power-on → No-load → On-load)

단계 1: Pre-power Check (전원 끄기)

  1. Check rated current on motor nameplate, set the current knob to motor rated current (즉)

예: Motor rated 88A → Align knob at 88A; do not set directly to 200A

Range 50-200A, Class10E fixed and non-adjustable

  1. Set M/A DIP switch per process requirement (M is default)
  2. Check tightening torque of busbar bolts, no loose 3-phase busbar connections; secure auxiliary terminal screws
  3. 멀티미터를 이용한 연속성 테스트: 95-96 conducting normally; 97-98 open normally

단계 2: Power on Auxiliary Supply and Test Functions (No High Voltage on Main Circuit!)

  1. Supply power only to A1/A2, no 380V on main circuit
  2. 누르다 [시험] 단추:

95-96 열립니다, 97-98 closes → Contact action normal

Release TEST and press RESET to restore normal state

TEST only simulates contact action, does not simulate real overload current, it is a loop verification

  1. 테스트 재설정: For M mode, RESET button must be pressed to restore after test; for A mode wait for auto reset (M mode is used during commissioning generally)

단계 3: Energize Main Circuit and No-load Test Run

  1. Close main circuit, start motor for no-load operation
  2. Measure 3-phase no-load current with clamp meter and record; confirm no severe unbalance
  3. If 3-phase current deviation>20%, check motor, wiring and power supply first. The electronic relay will trip for phase loss/unbalance protection directly

단계 4: On-load Operation and Current Verification (비판적인)

  1. After motor runs stably at rated load, measure 3-phase operating current with clamp meter
  2. If steady operating current is 70A, set the knob to 70A;
  3. Pay attention not to run below the lower limit of the range if starting inrush current is high and rated current is near 50A lower limit;

Definition of Class10E: Trips within 10s at 7.2 시간 정격 전류, suitable for standard motors; not suitable for heavy-duty long-start applications (use 3RB2056-2FC2 Class20E for heavy duty)

단계 5: Fault Simulation and Acceptance

  1. Cut off one phase (power off before operation), energize and verify: thermal relay triggers phase loss protection, 95-96 opens to stop motor
  2. 기록: setting current, 재설정 모드, trip logs
  3. Acceptance criteria: 초과 적재, phase loss and phase unbalance trigger reliable tripping; self-locking circuit and fault signal output normal
  4. Quick Fault Troubleshooting
  5. 과부하시 트립 없음: ① A1/A2 no power supply (no supply = no protection for electronic relay); ② setting current too high; ③ TEST button failure
  6. Trip immediately upon energizing: 심각한 3상 불균형, 모터 권선 단락, setting current too low
  7. Cannot auto reset after trip: DIP switch at M (정상); if switch at A and still no auto reset, device aging
  8. Normal no-load, trips frequently under load: 모터 과부하, bearing jam, large supply voltage drop, setting current too low
  9. Important Safety Reminders

This is an electronic thermal relay. Protection fails if A1/A2 power is lost! This differs fundamentally from traditional bimetallic 3RU thermal relays

S6 busbar requires strict tightening torque. Poor contact causes heating and false tripping

Automatic reset mode A is forbidden for safety-critical equipment (컨베이어, 믹서)

  1. Matching Replacement Reference

Same frame Class10: New generation 3RB3056

Same frame Class20: 3RB2056-2FC2 (heavy-duty start)

3RB2056-1FC2 (S6 / 50-200에이 / Class10E) 결함 & 솔루션

Pre-reminder: Electronic relay loses all protection without A1/A2 supply, different from traditional bimetallic 3RU. No fault indicator LEDs. Troubleshooting relies on TEST button, multimeter and clamp meter.

잘못 1: No trip when motor is overloaded (Protection failure)

징후: Motor overheats obviously, 95-96 contacts of thermal relay do not act and motor does not stop

원인 1: A1/A2 auxiliary supply lost, wrong voltage or loose terminals (Most frequent)

치료: Measure A1/A2 voltage; verify supply specification; tighten auxiliary terminals. Continuous power supply is required for current detection

원인 2: Current knob set far higher than motor rated current

치료: Reset to motor rated current per nameplate, verify with clamp meter under operation

원인 3: Loose main busbar bolts, poor contact and abnormal internal sampling

치료: 전원 끄기, tighten 3-phase busbar to S6 specified torque; check busbar for oxidation and discoloration from heat

원인 4: Internal sampling board damaged or component aging (High risk for discontinued stock units)

치료: Run TEST test. If 95-96 does not switch when TEST pressed → relay damaged, 직접 교체

잘못 2: Normal no-load, frequent tripping under load (거짓 트립)

징후: Starts fine without load, trips shortly after loading, 95-96 열립니다

원인 1: 전류를 너무 낮게 설정함; Class10E trips fast, not fit for heavy-duty long-start motors

치료: 모터 정격 전류 확인; use 3RB2056-2FC2 (Class20E) for heavy starting applications

원인 2: 3-위상 전류 불균형, 위상 손실, burnt contactor contacts

치료: Measure 3-phase currents with clamp meter; trip triggered if deviation>20%; check upstream contactor and power supply

원인 3: Loose busbar generates heat and sampling drift causes false overload judgement

치료: Stop equipment, check busbar temperature and oxidation, 다시 조이다

원인 4: 주위온도 60℃ 이상, 열악한 캐비닛 환기

치료: 냉각 개선; reserve current margin for high-temperature environments

잘못 3: Immediate trip when energizing / 시작 (Trip on switch-on)

징후: Thermal relay trips as soon as main circuit is energized before motor rotates

원인 1: Motor winding short circuit, insulation failure, mechanical seizure or stall

치료: Disconnect motor, test insulation with megger; check bearing by hand rotation

원인 2: Interference on A1/A2 supply, large control voltage fluctuation

치료: Add filter on control supply; separate supply from variable frequency drives and large contactors

원인 3: DIP switch at A auto reset, fault still present and re-trips immediately after closing

치료: Switch to M manual reset, eliminate root fault before re-energizing, avoid repeated trial switching

잘못 4: 트립 후에는 재설정할 수 없습니다. (RESET button ineffective)

징후: After protection triggers, 95-96 cannot restore conduction even after pressing RESET

원인 1: Root fault persists (지속적인 과부하, 위상 손실, 발작) so protection latches

치료: Cut main circuit, eliminate load fault then reset

원인 2: DIP switch at M manual reset but A1/A2 supply drops

치료: Reset only with stable A1/A2 supply; reset not possible when power is lost

원인 3: 내부 기계적 걸림, contact welding or electronic board latch-up

치료: Power off and rest for 5 minutes and retry; if still fails TEST test, 장치 교체

보충: 3RB20 has no remote reset terminals. Remote reset is available only on 3RB21. Do not add external remote reset wiring.

잘못 5: Auto reset mode A fails to reset automatically

징후: Set to auto reset, no recovery after long waiting post trip

원인 1: A1/A2 auxiliary supply interrupted, auto-reset timer stops when power is lost

치료: Keep A1/A2 continuously powered

원인 2: Fault remains active (persistent overload, 위상 손실), protection stays latched and will not reset

치료: Root fault must be cleared first

원인 3: Unit aging, auto-reset timing circuit failure

치료: Change to M manual reset; replace if auto reset is mandatory

잘못 6: TEST button no response (Contacts do not switch on TEST press)

징후: Only A1/A2 powered, 95-96 remains closed and 97-98 stays open when TEST pressed

원인 1: A1/A2 no power supply or mismatched voltage

치료: Measure auxiliary supply voltage

원인 2: TEST button mechanically jammed or internal electronic board damaged

치료: Power off and clean; replace relay if still invalid

TEST only verifies auxiliary contact loop, does not simulate real overload current. Passing TEST only confirms contact loop works, not current sampling.

잘못 7: No fault signal output from 97-98 after trip (PLC no fault feedback)

징후: Motor stops after trip but NO fault signal output

원인 1: Loose wiring or broken wire on 97-98 터미널

치료: Measure continuity of 97-98 under tripped state

원인 2: Insufficient contact rating, voltage drop when driving low-power PLC DI

치료: Confirm contact load rating; add intermediate relay if required

원인 3: Internal auxiliary contact burnt and damaged

치료: Run TEST test; replace relay if 97-98 does not close

잘못 8: Random intermittent tripping during operation

징후: Current reading normal, trips irregularly

원인 1: Intermittent loose connection on busbar or auxiliary terminals (진동, thermal expansion)

치료: Retighten all terminals and check cabinet vibration

원인 2: Control supply fluctuation and harmonic interference (common with VFD circuits)

치료: Add isolation on control loop; this model is not recommended directly on VFD output, dedicated motor protection relay preferred

원인 3: Unit aging, sampling circuit drift (Common for old discontinued stock)

치료: 릴레이 교체, prefer 3RB30 new generation

잘못 9: Relay latches to trip immediately after auxiliary power on, motor not energized

징후: 380V main circuit not powered, 95-96 opens right after A1/A2 supply is switched on

원인: Internal electronic board failure, damaged sampling circuit

치료: Replace overload relay

Standard Field Troubleshooting Flow

  1. Confirm A1/A2 auxiliary power supply normal (First check for electronic relay)
  2. Trigger TEST button to verify contact operation
  3. Measure 3-phase operating current with clamp meter and cross-check setting value
  4. Inspect 3-phase voltage, contactor contacts, motor insulation and busbar tightness
  5. Confirm M/A reset mode matches process requirements
  6. If all above checks pass and fault persists → Relay internal damage

Critical Pitfall Notes

  1. Not recommended for direct use on VFD output side; harmonics cause false detection
  2. Auto reset mode A must not be used long-term on safety equipment (컨베이어, 믹서)
  3. 이 모델은 단종되었습니다; inventory spares suffer higher electronic board aging risk than newer 3RB30 series
  4. S6 busbar loose torque causes continuous heating and sampling drift false tripping

SIRIUS 3RB2 Electronic Overload Relay Series Overview

Series includes: 3RB20 (표준 버전, no remote reset), 3RB21 (Enhanced version with remote reset terminals); All discontinued by OEM, only spare stock available. Electronic type requiring A1/A2 auxiliary supply; 보호: 초과 적재, 위상 손실, 위상 불균형, 마구간; Standard contacts 1NO+1NC; 주회로 버스바 연결; Frame sizes S6 / S10 / S12; Current range 50~820A

모델 코드 정의 (3RB2 □ □□ □□□)

3RB20: 기본 버전, no remote reset (3RB2056-1FC2 belongs here)

3RB21: 향상된 버전, with remote reset terminals A3/A4

5th-6th digits: 56=S6 (50-200에이); 66=S10/S12 (55-630에이)

접두사 1 = Class10E; 접두사 2 = Class20E (heavy-duty start)

접미사:

FC2: 나사 터미널, direct snap-on to contactor

FF2: 독립형 장착, 나사 터미널

FW2: 스프링 터미널, snap-on

FX2: 스프링 터미널 + standalone mounting

GC2 / GF2 / MC2 / MF2: S10/S12 specifications

  1. 3RB20 Series List (No Remote Reset)
주문 번호.현재 범위액자여행 클래스일치하는 접촉기비고
3RB2056-1FC250-200AS6Class10E3RT1056Snap-on, 나사 터미널, main subject, 단종
3RB2056-1FF250-200AS6Class10E3RT1056독립형, 나사 터미널
3RB2056-1FW250-200AS6Class10E3RT1056Snap-on, 스프링 터미널
3RB2056-1FX250-200AS6Class10E3RT1056독립형, 스프링 터미널
3RB2056-2FC250-200AS6Class20E3RT1056Heavy-duty snap-on, 나사 터미널, popular replacement
3RB2056-2FF250-200AS6Class20E3RT1056Heavy-duty standalone, 나사 터미널
3RB2056-2FW250-200AS6Class20E3RT1056Heavy-duty snap-on, 스프링 터미널
3RB2056-2FX250-200AS6Class20E3RT1056Heavy-duty standalone, 스프링 터미널
3RB2066-1GC255-250AS10Class10E3RT1065Snap-on, 나사 터미널
3RB2066-1GF255-250AS10Class10E3RT1065독립형, 나사 터미널
3RB2066-1MC2160-630AS12Class10E3RT1066Snap-on, 나사 터미널
3RB2066-1MF2160-630AS12Class10E3RT1066독립형, 나사 터미널
3RB2066-2GC255-250AS10Class20E3RT1065Heavy-duty snap-on, 나사 터미널
3RB2066-2GF255-250AS10Class20E3RT1065Heavy-duty standalone, 나사 터미널
3RB2066-2MC2160-630AS12Class20E3RT1066Heavy-duty snap-on, 나사 터미널
3RB2066-2MF2160-630AS12Class20E3RT1066Heavy-duty standalone, 나사 터미널
3RB2011 + 3UF18630–820AS14Class10E3TF68/3TF69CT combination solution
  1. 3RB21 Series List (With Remote Reset A3/A4)

Suitable for PLC remote reset; protection functions and current ranges same as 3RB20

| 3RB2156-1FC2 | 50-200에이 | S6 | Class10E | Remote reset, snap-on, 나사 터미널 |

| 3RB2156-1FF2 | 50-200에이 | S6 | Class10E | Remote reset, 독립형, 나사 터미널 |

| 3RB2156-2FC2 | 50-200에이 | S6 | Class20E | 헤비 듀티 + 원격 재설정 |

| 3RB2166-1GC2 | 55-250에이 | S10 | Class10E | S10 remote reset |

| 3RB2166-1MC2 | 160-630에이 | S12 | Class10E | S12 remote reset |

| 3RB2166-2GC2 | 55-250에이 | S10 | Class20E | S10 heavy duty + 원격 재설정 |

| 3RB2166-2MC2 | 160-630에이 | S12 | Class20E | S12 heavy duty + 원격 재설정 |

| 3RB2111 + 3UF18 | 630-820에이 | S14 | Class10E | CT combination, 원격 재설정 |

 

  1. Common Series Parameters
  2. Auxiliary supply: A1/A2, AC/DC 24V or AC110~240V (depends on sub-version). Protection fails when supply is lost
  3. 보조 접점: 95-96 (NC), 97-98 (아니요), 1아니요+1NC, 5등급
  4. 다시 놓기: M/A DIP switch (수동 / auto reset); 3RB21 adds A3/A4 remote reset
  5. 보호 등급: IP20; Insulation voltage 1000V AC, 전류 내전압 8kV; Operating temperature -25~+60℃
  6. 주회로: 부스바 연결, not through-core CT type
  7. 애플리케이션: Standard 3-phase asynchronous motors; Not recommended directly on VFD output; harmonics cause false tripping
  8. New Generation Replacement Series (새로운 프로젝트에 권장)

S6 50-200A replacement: 3RB3056 (새로운 세대, 더 나은 안정성, active supply)

S10/S12 high-current: 3RB3066 for equivalent replacement

  1. 빠른 선택 가이드

No remote reset required → 3RB20

PLC remote reset required → 3RB21

표준 팬, 슬리퍼, smooth start → Class10E (접두사 1)

벨트 컨베이어, 파쇄기, heavy-duty long start → Class20E (접두사 2)

Snap-on mounting with contactor → FC2 / GC2 / MC2

Separate backplate mounting → FF2 / GF2 / MF2