Industrial coupling relay of Siemens SIRIUS series, 갖춘 2 전환 연락처, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for PLC signal isolation and control circuit coupling.
- 모델 코드 해석
| 모델 세그먼트 | 의미 |
| 3RQ | Product family code for Siemens SIRIUS coupling / interface relays |
| 2 | Generation code, distinguishing from 3RQ0, 3RQ3 and other series |
| 0 | Basic model with wide voltage range of 24-240V AC/DC |
| -1 | 터미널 유형 코드: 1 = Screw terminal, 2 = Spring terminal |
| 비 | Contact configuration code: 비 = 2 전환 연락처 (2콜로라도); A = 1 전환 연락처 (1콜로라도); C = 3 전환 연락처 (3콜로라도) |
| 여 | Contact material & characteristic code: W = Standard silver tin oxide (AgSnO) 연락하다; CW01 = Hard gold plated contact |
| 0 | Supplementary code for version & 사양, no special definition |
성명: Enclosed industrial coupling relay, 2 전환 연락처, 24-240V AC/DC wide voltage, 나사식 터미널 연결.
- 핵심 기술 매개변수
| 매개변수 카테고리 | 사양 | 비고 |
| 기본정보 | ||
| 상표 / 시리즈 | Siemens SIRIUS 3RQ2 | Industrial-grade signal coupling solution |
| 주문 번호. | 3RQ2000-1BW00 | Standard part number |
| 장착 유형 | DIN 레일 마운트, 너비: 22.5mm | EN 준수 60715 |
| 유입 방지 | IP20 | Finger-proof and dust-proof |
| 전기적 매개변수 | ||
| 제어 전압 범위 | 24-240V AC/DC | Wide voltage design for high versatility |
| Rated Control Power | 4.5여 | 낮은 전력 소비 |
| 연락처 구성 | 2 전환 연락처 (2콜로라도) | Each contact consists of 1 아니요 + 1 NC |
| Rated Contact Current | 5A @ 250V AC | For resistive load |
| 맥스. Switching Voltage | 300V AC/DC | IEC를 준수 60947-1 |
| 절연 전압 | 300다섯 (Overvoltage Category III, 오염도 3) | Excellent insulation performance |
| 임펄스 내전압 | 4kV | Strong surge resistance |
| 기계적 매개변수 | ||
| 치수 (폭 × 높이 × 깊이) | 22.5×90×65mm | 컴팩트한 구조 |
| 무게 | 대략. 100g | 쉬운 설치 |
| 기계적 수명 | 1,000,000 운영 | 높은 내구성 |
| 전기적 수명 | 100,000 운영 (정격 부하에서) | Stable and reliable performance |
| 환경 매개변수 | ||
| 작동 온도 | -40°C ~ +60°C | 가혹한 산업 환경에 적응 가능 |
| 보관 온도 | -40°C ~ +85°C | Wide temperature range for storage |
| 습도 범위 | 5%~95% (비응축) | Suitable for humid conditions |
| 오염도 | 3 | Applicable to dusty industrial sites |
- Cross-brand & Obsolete Model Replacement List
| 원래 모델 | 교체 모델 | 교체 설명 |
| Siemens 3TX7002-1CB00 | 3RQ2000-1BW00 | Official recommended replacement; 22.5mm width unchanged, 완벽한 기능 호환 |
| Siemens 3RS1800-1BW00 | 3RQ2000-1BW00 | Official replacement; discontinued since Oct 1, 2022 |
| Siemens 3RQ2000-1AW00 | 3RQ2000-1BW00 | In-series upgrade from 1CO to 2 전환 연락처 |
| Schneider RXM4AB2BD | 3RQ2000-1BW00 | 기능적으로 동일함; 2콜로라도, 24-240V AC/DC, DIN 레일 마운트 |
| ABB CR-M230AC2 | 3RQ2000-1BW00 | 기능적으로 동일함; 2콜로라도, 넓은 전압, industrial application |
선택 팁: Verify full consistency of contact quantity, 터미널 유형, mounting dimensions and electrical parameters before replacement.
- Full Model List of 3RQ2000 Series
| 모델 | 연락처 구성 | 터미널 유형 | 접촉 재료 | 전압 범위 | 비고 |
| 3RQ2000-1AW00 | 1콜로라도 | 나사 | 기준 | 24-240V AC/DC | 기본 모델 |
| 3RQ2000-1BW00 | 2콜로라도 | 나사 | 기준 | 24-240V AC/DC | Subject model |
| 3RQ2000-1CW00 | 3콜로라도 | 나사 | 기준 | 24-240V AC/DC | Multi-contact model |
| 3RQ2000-1CW01 | 3콜로라도 | 나사 | Hard gold plated | 24-240V AC/DC | 높은 신뢰성, for light load |
| 3RQ2000-2AW00 | 1콜로라도 | 봄 | 기준 | 24-240V AC/DC | Fast wiring model |
| 3RQ2000-2BW00 | 2콜로라도 | 봄 | 기준 | 24-240V AC/DC | 스프링 터미널, 2 전환 연락처 |
| 3RQ2000-2CW00 | 3콜로라도 | 봄 | 기준 | 24-240V AC/DC | 스프링 터미널, 3 전환 연락처 |
| 3RQ2000-2CW01 | 3콜로라도 | 봄 | Hard gold plated | 24-240V AC/DC | 스프링 터미널, 높은 신뢰성 |
- 일반적인 결함 & 문제 해결
| 결함 현상 | 가능한 원인 | 솔루션 |
| Relay fails to operate | 1. Control voltage out of range | 1. Measure voltage and ensure it is within 24-240V |
| 2. Loose terminals | 2. Check and tighten screw terminals | |
| 3. 구운 코일 | 3. 릴레이 교체 | |
| 접촉불량 | 1. 산화 / contamination of contacts | 1. Clean contacts or replace the relay |
| 2. Contact welding caused by overload | 2. Reduce load or select higher-capacity model | |
| 3. Excessive vibration during operation | 3. Fasten installation and add vibration dampers | |
| Indicator light off while relay operates normally | 1. Damaged LED indicator | 1. Replace LED module |
| 2. Fault of indicator circuit | 2. Inspect wiring of indicator circuit | |
| Random operation of relay | 1. Interference on control circuit | 1. Use shielded cables and keep away from interference sources such as inverters |
| 2. 심한 전압 변동 | 2. 전압 안정기 설치 | |
| 3. Ambient temperature out of limit | 3. Improve heat dissipation or select high-temperature resistant model | |
| Overheated terminals | 1. 느슨한 배선 | 1. 단자를 다시 조이세요 |
| 2. Undersized wire cross-section | 2. Replace with wires of proper cross-section | |
| 3. 과도한 부하 전류 | 3. Reduce load or replace the relay |
- 적용범위 & 산업 사례
6.1 적용 가능한 시나리오
PLC Signal Isolation: Couple signals between PLC outputs and field actuators to protect PLC modules.
제어 회로 확장: Increase available control signals to drive multiple loads via one signal.
Voltage Conversion: Connect control circuits with different voltage levels, 예를 들어. 24V DC PLC output for 220V AC contactors.
Interference Suppression: Isolate signals in high-interference environments such as inverters and welding equipment to avoid false triggering.
산업 자동화 시스템: 생산 라인 제어, 포장 기계, 공작기계, 컨베이어 시스템, 등.
6.2 권장되지 않는 시나리오
High-frequency switching: Not suitable for frequent switching over 10 cycles per second.
Inductive load without protection: Surge suppressors are mandatory when driving inductive loads such as motors and solenoid valves.
Corrosive environments: No special anti-corrosion treatment; not for strong acid, alkali or high salt mist conditions.
Explosive hazardous areas: 비방폭 설계; prohibited for flammable and explosive locations.
6.3 일반적인 적용 사례
사례 1: 자동차 부품 생산 라인
애플리케이션: PLC controls clamps and welding torches of robotic welding stations.
구성: 3RQ2000-1BW00 isolates PLC output signals from 220V AC solenoid coils.
결과: Resists welding current interference; failure rate reduced by 90%, 유지관리 비용 절감 50%.
사례 2: 음식 & Beverage Filling Line
애플리케이션: Connect HMI touch panel and filling valve control circuits.
구성: Two units of 3RQ2000-1BW00 control 4 filling valves (2 아니요 + 2 NC) via one HMI signal.
결과: 단순화된 배선, improved system reliability and fewer spare part types.
사례 3: 지능형 창고 시스템
애플리케이션: Isolate position sensor signals of stacker cranes and PLC inputs.
구성: 3RQ2000-1BW00 converts 24V DC sensor signals to PLC-compatible signals.
결과: Eliminates interference from long-distance signal transmission; positioning accuracy improved to ±1mm.
- 선택 지침 & 빠른 참조 규칙
- Contact quantity by letter: A = 1CO, B = 2CO, C = 3CO
- Terminal type by digit: 1 = Screw terminal, 2 = Spring terminal
- Contact material by suffix: W = Standard contact, CW01 = Gold-plated contact
- Universal voltage: Full series supports 24-240V AC/DC
- Priority for replacement: Directly replace 3TX7 / 3RS18 series with corresponding 3RQ2000 models
Ordering Notice: Standard package: 1 unit per box; 최소 주문 수량: 1 단위. It is recommended to prepare 2~3 units as spare parts for general industrial automation control.
Common Faults and Troubleshooting of Siemens 3RQ2000-1BW00 Coupling Relay
- Relay Fails to Operate Completely
- No power supply to coil
Measure input voltage to confirm it is within 24~240V AC/DC. Check circuit breakers, fuses and continuity of upstream control circuits, and tighten loose terminals.
- Loose / poor terminal connection
Retighten screw terminals. Check wire crimping, broken wires and wires trapped under terminal screws.
- 구운 코일
Long-term overvoltage or frequent voltage surges will burn the coil. Replace the relay if burnt marks or abnormal odour are observed.
- 기계적 방해
Accumulated dust and continuous vibration cause internal armature sticking. Tap the housing gently for test; replace the relay if the issue persists.
- Coil Pulls In but Contacts Open / Poor Contact
- Oxidation and dust accumulation on contacts
Commonly seen in humid and dusty environments, especially for low-power signal circuits. Clean contacts after power cut and test with repeated switching operations.
- 접촉용접
Excessive load current or frequent inrush load leads to stuck contacts. Disconnect the load for verification. Replace the relay as welded contacts cannot be repaired.
- Fault on load side circuit
Troubleshoot downstream contactors, solenoid valves and broken wires. Confirm relay fault only after excluding external failures.
- Random Operation / Unexpected On & 끄다
- 전자기 간섭
Easily affected when installed close to inverters, 모터, high-power contactors or long control cables. Route control cables away from power cables and apply shielded wires and surge absorbers.
- Voltage fluctuation & electrical noise
Sudden voltage drop and voltage spikes cause false operation. Install voltage stabilizers and filters on the upstream side.
- Abnormal ambient temperature
Operation above +60°C or condensation under low temperature leads to internal circuit malfunction. 환기 개선, dehumidification and heat dissipation.
- Abnormal Indicator Light
- Light off, relay works normally
Only the LED bulb is damaged. The relay can remain in service or be replaced.
- Light always on / 꺼질 것 같은, relay does not operate
Malfunction of internal voltage divider and indicator circuit, usually accompanied by coil failure. Replace the relay directly.
- Overheated Wiring Terminals
- 느슨한 배선: Retighten terminals to specified torque.
- Undersized wire gauge: Replace with cables with cross-section matching the load current.
- Continuous overload: Actual load exceeds rated 5A contact current. Apply load sharing or use higher-capacity relay.
- Frequent Failures under Inductive Load (Solenoid / 접촉기)
Symptoms: Shortened contact service life, frequent contact welding and unexpected tripping
문제 해결: The absence of surge suppressors causes reverse high voltage from inductive loads to damage contacts during power-off. Connect freewheeling diodes (DC의 경우) or RC snubbers (AC용) in parallel across inductive loads.
- On-site Quick Troubleshooting Procedure
- Cut off power → Inspect appearance, wiring and terminal tightness
- Switch on power → Measure input control voltage
- Observe indicator light and listen to pull-in sound to judge coil status
- Cut off power → Test NO/NC contacts with multimeter continuity mode
- Distinguish faults among upstream control circuit, relay itself and downstream load circuit
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지





















NH42-63-318x560.png)