Siemens 3RQ2000-1BW00 Coupling Relay - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Siemens 3RQ2000-1BW00 Coupling Relay - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/

Siemens 3RQ2000-1BW00 Coupling Relay

Industrial coupling relay of Siemens SIRIUS series, 갖춘 2 전환 연락처, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for PLC signal isolation and control circuit coupling. Model Code Interpretation Model Segment Meaning 3RQ Product family code for Siemens SIRIUS coupling / ...

  • 제품 세부정보

Industrial coupling relay of Siemens SIRIUS series, 갖춘 2 전환 연락처, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for PLC signal isolation and control circuit coupling.

  1. 모델 코드 해석
모델 세그먼트의미
3RQProduct family code for Siemens SIRIUS coupling / interface relays
2Generation code, distinguishing from 3RQ0, 3RQ3 and other series
0Basic model with wide voltage range of 24-240V AC/DC
-1터미널 유형 코드: 1 = Screw terminal, 2 = Spring terminal
Contact configuration code: 비 = 2 전환 연락처 (2콜로라도); A = 1 전환 연락처 (1콜로라도); C = 3 전환 연락처 (3콜로라도)
Contact material & characteristic code: W = Standard silver tin oxide (AgSnO) 연락하다; CW01 = Hard gold plated contact
0Supplementary code for version & 사양, no special definition

성명: Enclosed industrial coupling relay, 2 전환 연락처, 24-240V AC/DC wide voltage, 나사식 터미널 연결.

  1. 핵심 기술 매개변수
매개변수 카테고리사양비고
기본정보
상표 / 시리즈Siemens SIRIUS 3RQ2Industrial-grade signal coupling solution
주문 번호.3RQ2000-1BW00Standard part number
장착 유형DIN 레일 마운트, 너비: 22.5mmEN 준수 60715
유입 방지IP20Finger-proof and dust-proof
전기적 매개변수
제어 전압 범위24-240V AC/DCWide voltage design for high versatility
Rated Control Power4.5여낮은 전력 소비
연락처 구성2 전환 연락처 (2콜로라도)Each contact consists of 1 아니요 + 1 NC
Rated Contact Current5A @ 250V ACFor resistive load
맥스. Switching Voltage300V AC/DCIEC를 준수 60947-1
절연 전압300다섯 (Overvoltage Category III, 오염도 3)Excellent insulation performance
임펄스 내전압4kVStrong surge resistance
기계적 매개변수
치수 (폭 × 높이 × 깊이)22.5×90×65mm컴팩트한 구조
무게대략. 100g쉬운 설치
기계적 수명1,000,000 운영높은 내구성
전기적 수명100,000 운영 (정격 부하에서)Stable and reliable performance
환경 매개변수
작동 온도-40°C ~ +60°C가혹한 산업 환경에 적응 가능
보관 온도-40°C ~ +85°CWide temperature range for storage
습도 범위5%~95% (비응축)Suitable for humid conditions
오염도3Applicable to dusty industrial sites
  1. Cross-brand & Obsolete Model Replacement List
원래 모델교체 모델교체 설명
Siemens 3TX7002-1CB003RQ2000-1BW00Official recommended replacement; 22.5mm width unchanged, 완벽한 기능 호환
Siemens 3RS1800-1BW003RQ2000-1BW00Official replacement; discontinued since Oct 1, 2022
Siemens 3RQ2000-1AW003RQ2000-1BW00In-series upgrade from 1CO to 2 전환 연락처
Schneider RXM4AB2BD3RQ2000-1BW00기능적으로 동일함; 2콜로라도, 24-240V AC/DC, DIN 레일 마운트
ABB CR-M230AC23RQ2000-1BW00기능적으로 동일함; 2콜로라도, 넓은 전압, industrial application

선택 팁: Verify full consistency of contact quantity, 터미널 유형, mounting dimensions and electrical parameters before replacement.

  1. Full Model List of 3RQ2000 Series
모델연락처 구성터미널 유형접촉 재료전압 범위비고
3RQ2000-1AW001콜로라도나사기준24-240V AC/DC기본 모델
3RQ2000-1BW002콜로라도나사기준24-240V AC/DCSubject model
3RQ2000-1CW003콜로라도나사기준24-240V AC/DCMulti-contact model
3RQ2000-1CW013콜로라도나사Hard gold plated24-240V AC/DC높은 신뢰성, for light load
3RQ2000-2AW001콜로라도기준24-240V AC/DCFast wiring model
3RQ2000-2BW002콜로라도기준24-240V AC/DC스프링 터미널, 2 전환 연락처
3RQ2000-2CW003콜로라도기준24-240V AC/DC스프링 터미널, 3 전환 연락처
3RQ2000-2CW013콜로라도Hard gold plated24-240V AC/DC스프링 터미널, 높은 신뢰성
  1. 일반적인 결함 & 문제 해결
결함 현상가능한 원인솔루션
Relay fails to operate1. Control voltage out of range1. Measure voltage and ensure it is within 24-240V
2. Loose terminals2. Check and tighten screw terminals
3. 구운 코일3. 릴레이 교체
접촉불량1. 산화 / contamination of contacts1. Clean contacts or replace the relay
2. Contact welding caused by overload2. Reduce load or select higher-capacity model
3. Excessive vibration during operation3. Fasten installation and add vibration dampers
Indicator light off while relay operates normally1. Damaged LED indicator1. Replace LED module
2. Fault of indicator circuit2. Inspect wiring of indicator circuit
Random operation of relay1. Interference on control circuit1. Use shielded cables and keep away from interference sources such as inverters
2. 심한 전압 변동2. 전압 안정기 설치
3. Ambient temperature out of limit3. Improve heat dissipation or select high-temperature resistant model
Overheated terminals1. 느슨한 배선1. 단자를 다시 조이세요
2. Undersized wire cross-section2. Replace with wires of proper cross-section
3. 과도한 부하 전류3. Reduce load or replace the relay
  1. 적용범위 & 산업 사례

6.1 적용 가능한 시나리오

PLC Signal Isolation: Couple signals between PLC outputs and field actuators to protect PLC modules.

제어 회로 확장: Increase available control signals to drive multiple loads via one signal.

Voltage Conversion: Connect control circuits with different voltage levels, 예를 들어. 24V DC PLC output for 220V AC contactors.

Interference Suppression: Isolate signals in high-interference environments such as inverters and welding equipment to avoid false triggering.

산업 자동화 시스템: 생산 라인 제어, 포장 기계, 공작기계, 컨베이어 시스템, 등.

6.2 권장되지 않는 시나리오

High-frequency switching: Not suitable for frequent switching over 10 cycles per second.

Inductive load without protection: Surge suppressors are mandatory when driving inductive loads such as motors and solenoid valves.

Corrosive environments: No special anti-corrosion treatment; not for strong acid, alkali or high salt mist conditions.

Explosive hazardous areas: 비방폭 설계; prohibited for flammable and explosive locations.

6.3 일반적인 적용 사례

사례 1: 자동차 부품 생산 라인

애플리케이션: PLC controls clamps and welding torches of robotic welding stations.

구성: 3RQ2000-1BW00 isolates PLC output signals from 220V AC solenoid coils.

결과: Resists welding current interference; failure rate reduced by 90%, 유지관리 비용 절감 50%.

사례 2: 음식 & Beverage Filling Line

애플리케이션: Connect HMI touch panel and filling valve control circuits.

구성: Two units of 3RQ2000-1BW00 control 4 filling valves (2 아니요 + 2 NC) via one HMI signal.

결과: 단순화된 배선, improved system reliability and fewer spare part types.

사례 3: 지능형 창고 시스템

애플리케이션: Isolate position sensor signals of stacker cranes and PLC inputs.

구성: 3RQ2000-1BW00 converts 24V DC sensor signals to PLC-compatible signals.

결과: Eliminates interference from long-distance signal transmission; positioning accuracy improved to ±1mm.

  1. 선택 지침 & 빠른 참조 규칙
  2. Contact quantity by letter: A = 1CO, B = 2CO, C = 3CO
  3. Terminal type by digit: 1 = Screw terminal, 2 = Spring terminal
  4. Contact material by suffix: W = Standard contact, CW01 = Gold-plated contact
  5. Universal voltage: Full series supports 24-240V AC/DC
  6. Priority for replacement: Directly replace 3TX7 / 3RS18 series with corresponding 3RQ2000 models

Ordering Notice: Standard package: 1 unit per box; 최소 주문 수량: 1 단위. It is recommended to prepare 2~3 units as spare parts for general industrial automation control.

Common Faults and Troubleshooting of Siemens 3RQ2000-1BW00 Coupling Relay

  1. Relay Fails to Operate Completely
  2. No power supply to coil

Measure input voltage to confirm it is within 24~240V AC/DC. Check circuit breakers, fuses and continuity of upstream control circuits, and tighten loose terminals.

  1. Loose / poor terminal connection

Retighten screw terminals. Check wire crimping, broken wires and wires trapped under terminal screws.

  1. 구운 코일

Long-term overvoltage or frequent voltage surges will burn the coil. Replace the relay if burnt marks or abnormal odour are observed.

  1. 기계적 방해

Accumulated dust and continuous vibration cause internal armature sticking. Tap the housing gently for test; replace the relay if the issue persists.

  1. Coil Pulls In but Contacts Open / Poor Contact
  2. Oxidation and dust accumulation on contacts

Commonly seen in humid and dusty environments, especially for low-power signal circuits. Clean contacts after power cut and test with repeated switching operations.

  1. 접촉용접

Excessive load current or frequent inrush load leads to stuck contacts. Disconnect the load for verification. Replace the relay as welded contacts cannot be repaired.

  1. Fault on load side circuit

Troubleshoot downstream contactors, solenoid valves and broken wires. Confirm relay fault only after excluding external failures.

  1. Random Operation / Unexpected On & 끄다
  2. 전자기 간섭

Easily affected when installed close to inverters, 모터, high-power contactors or long control cables. Route control cables away from power cables and apply shielded wires and surge absorbers.

  1. Voltage fluctuation & electrical noise

Sudden voltage drop and voltage spikes cause false operation. Install voltage stabilizers and filters on the upstream side.

  1. Abnormal ambient temperature

Operation above +60°C or condensation under low temperature leads to internal circuit malfunction. 환기 개선, dehumidification and heat dissipation.

  1. Abnormal Indicator Light
  2. Light off, relay works normally

Only the LED bulb is damaged. The relay can remain in service or be replaced.

  1. Light always on / 꺼질 것 같은, relay does not operate

Malfunction of internal voltage divider and indicator circuit, usually accompanied by coil failure. Replace the relay directly.

  1. Overheated Wiring Terminals
  2. 느슨한 배선: Retighten terminals to specified torque.
  3. Undersized wire gauge: Replace with cables with cross-section matching the load current.
  4. Continuous overload: Actual load exceeds rated 5A contact current. Apply load sharing or use higher-capacity relay.
  5. Frequent Failures under Inductive Load (Solenoid / 접촉기)

Symptoms: Shortened contact service life, frequent contact welding and unexpected tripping

문제 해결: The absence of surge suppressors causes reverse high voltage from inductive loads to damage contacts during power-off. Connect freewheeling diodes (DC의 경우) or RC snubbers (AC용) in parallel across inductive loads.

  1. On-site Quick Troubleshooting Procedure
  2. Cut off power → Inspect appearance, wiring and terminal tightness
  3. Switch on power → Measure input control voltage
  4. Observe indicator light and listen to pull-in sound to judge coil status
  5. Cut off power → Test NO/NC contacts with multimeter continuity mode
  6. Distinguish faults among upstream control circuit, relay itself and downstream load circuit

이전:

답장을 남겨주세요

메시지를 남겨주세요