지멘스 6SL3224-0BE13-7UA0 전원 모듈 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 지멘스 6SL3224-0BE13-7UA0 전원 모듈 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,감지기,인코더,PLC

전기 같은/

지멘스 6SL3224-0BE13-7UA0 전원 모듈

6SL3224: G120 PM240 power-module series 0BE13: 400 V class, 0.37 kW heavy-duty rating 7UA0: No integrated Class-A EMC filter, built-in braking chopper Status: 단종. Available only as spare-part; not for new-project selection. ⚠️ This is power-module only, CU control unit and BOP panel not included. Mandatorily used with CU240B-2 / CU240E-2 or equivalent control units for operation. ...

  • 제품 세부정보

6SL3224: G120 PM240 power-module 시리즈

0BE13: 400 V class, 0.37 kW heavy-duty rating

7UA0: No integrated Class-A EMC filter, built-in braking chopper

상태: 단종. Available only as spare-part; not for new-project selection.

⚠️ This is power-module only, CU control unit and BOP panel not included. Mandatorily used with CU240B-2 / CU240E-2 or equivalent control units for operation.

핵심 기술 사양

사양
Power Supply Input3‑phase AC 380‑480 V, 47-63Hz
Heavy‑Duty HO (0~+50 °C)0.37 kW, output current 1.3 A
Light‑Duty LO (0~+40 °C)0.55 kW, output current 1.7 A
HO Overload Capacity200 % for 3 s; 150 % for 57 s, cycle 300 s
프레임 크기FSA
보호 등급IP20
치수 (H×W×D)173 × 73 × 145 mm
무게1.1 kg
Hardware FeaturesIntegrated braking chopper, external braking resistor required; no built‑in line filter
출력 주파수0‑550 Hz

애플리케이션

Modular general-purpose SINAMICS G120 inverter for fans, 슬리퍼, belt conveyors and general variable-speed applications.

Built-in braking chopper suitable for fast-stop and potential-energy loads (small lifting mechanisms) with external braking resistor.

Without integrated EMC filter. 산업 환경용, external line filter is recommended: 6SE6400-2FA00-6AD0.

직접 교체 (New-Generation PM240-2)

PM240 legacy series discontinued. Frame-size-compatible replacement:

6SL3210-1PE11-8UL0 (PM240-2, 0.37 kW, no built-in filter, integrated braking chopper, FSA frame)

메모: Existing CU control units are fully compatible; parameters can be migrated directly. Mounting dimensions are identical.

중고 / Spare-part Inspection Checklist

  1. Visual check: Burn marks on DC-bus and power terminals; abnormal fan noise.
  2. 절연 테스트: Input-to-output, input-to-earth insulation resistance.
  3. Inverter stage: Measure forward/reverse diode drop of IGBTs to verify power semiconductors.
  4. Braking-chopper test: Check for short-circuit failure of braking power device.
  5. Commission with control-unit under load; verify 3-phase output current balance.

Hardware Manual Information for 6SL3224-0BE13-7UA0 (SINAMICS G120 PM240 FSA 0.37 kW)

Legacy discontinued PM240 power-module. Corresponding official hardware manual:

Document-ID: A5E36985441 SINAMICS G120 Power Module PM240 Hardware Manual, 풀어 주다 07-2016, 지멘스 CSID: 109738501.

This manual covers FSA-FSF frame PM240 units, including full mechanical mounting, wiring and maintenance for 6SL3224-0BE13-7UA0. Original is English; no standalone full-Chinese edition. Use the Chinese G120 system manual as complementary reference.

📥 Official Download Access

  1. Siemens Industry Support Portal, search by document-ID: 109738501 for original PDF.
  2. Siemens Download Center, search part-number: `6SL3224-0BE13-7UA0`, filter hardware-installation manual.

⚠️ Do NOT confuse with PM240-2 manual (ID:109812684). Hardware structures differ; manuals are not interchangeable.

📋 Key Manual Excerpts for FSA-Frame 6SL3224-0BE13-7UA0

  1. Safety Preconditions

ESD 보호: Wear anti-static wrist-strap during disassembly/assembly. 전원을 끈 후, wait 5 minutes for DC-bus capacitor full discharge before opening housing.

IP20 등급: Cabinet-mount only, outdoor installation forbidden.

  1. 기계적인 설치 (FSA Frame)
  2. 장착 방향: Vertical upright installation. Horizontal or inverted mounting prohibited.
  3. Cabinet clearances:

Top ≥100 mm; Bottom ≥100 mm; 0 mm side clearance; rear surface flush with mounting back-plate.

Operating ambient: 0~+50 °C for heavy-duty; 40°C 이상에서는 정격 감소 필요.

  1. Cut-out dimension: FSA mounting cut-out W62 mm × H162 mm; overall unit size:173 × 73 × 145 mm.
  2. Assembly sequence: Fix power-module first, then snap-fit CU control-unit (CU240B-2 / CU240E-2). Ensure full latch engagement and secure communication connector contact.
  3. 터미널 정의

L1/L2/L3: 3-phase 380-480 V AC mains input

U/V/W: Motor output

DC- / R2: Braking-resistor terminals. Braking chopper integrated; external resistor mandatory. Do NOT short-circuit. Recommended resistor order-code: 6SE6400-4BD11-0AA0 (0.37-1.5 kW PM240 compatible).

체육: 보호 접지. Reliable connection to cabinet protective-earth bar, cable cross-section ≥4 mm².

No built-in Class-A EMC filter. For high-EMI industrial sites, fit external line filter 6SE6400-2FA00-6AD0.

  1. 케이블 사양 (FSA-0.37 kW)

Mains input cable: minimum 1.5 mm²; motor cable: 1.5 mm²; protective earth ≥4 mm².

Separate power cables and control wiring; maintain minimum 20 cm spacing. Shielded motor cable is recommended with 360-degree shield termination to cabinet earth bar.

  1. Pre-power-on Check-List
  2. Confirm CU control-unit is fully latched without loose fit.
  3. Verify braking-resistor wiring; no short-circuit between DC-and R2.
  4. No phase-to-phase or phase-to-earth short-circuit on input and output terminals.
  5. Confirm supply voltage AC380-480 V; 220 V single-phase supply must not be applied.
  6. Check insulation of motor cable and motor winding.
  7. 유지보수 노트

FSA-frame PM240 has no field-replaceable fan unit. Periodically blow dust from cooling air-passages.

Retorque power terminals every 6 months; 조임 토크: 1.2 N·m.

⚠️ Critical Difference: Legacy PM240 vs PM240-2 replacement 6SL3210-1PE11-8UL0

Although FSA mounting holes are compatible, terminal layout and braking-circuit assignments differ. Do not apply PM240-2 installation manual to legacy 6SL3224-0BE13-7UA0.

Replacement Options for 6SL3224-0BE13-7UA0 (PM240 0.37 kW FSA)

Legacy PM240 officially discontinued. Hardware specification: 3-phase 380-480 V, no integrated EMC filter, built-in braking chopper, FSA frame, HO 0.37 kW(1.3 에이), LO 0.55 kW(1.7 에이).

Categories: Official upgrade, OEM spare-part, higher-rating same-series spare, compact all-in-one drive, domestic functional equivalent.

  1. Siemens Official Upgrade (PM240-2, Preferred for New Retrofits)

✅ Order-Code: 6SL3210-1PE11-8UL0

시리즈: SINAMICS G120 PM240-2; FSA frame; 3-phase 380-480 V; no built-in filter, integrated braking chopper.

HO rating:0.37 kW /1.3 A; LO rating:0.55 kW /1.7 A, power/current fully matched to original.

FSA mounting footprint compatible for drop-in installation in existing cabinet. Existing CU240B-2 / CU240E-2 control-units can be reused, parameters downloadable directly.

⚠️ Terminal layout and braking-resistor marking changed. Follow PM240-2 manual; do not copy legacy PM240 wiring. Minor depth difference; verify cabinet clearance.

Suffix explanation: -UL0 = without Class-A EMC filter; -AL0 = with integrated Class-A EMC filter (avoid mis-selection)

Common Wrong Selection to Avoid

❌6SL3210-1PE11-8AL0: Equipped with built-in EMC filter. Hardware condition mismatches original 7UA0; not recommended for direct swap.

  1. Spare-part Repair Solutions (No modification to program / 배선)
  2. Original part 6SL3224-0BE13-7UA0: 단종. Only used stock / 중고 유닛 사용 가능. 높은 비용, limited supply. For emergency repair with zero wiring/parameter change and CU reuse.

Second-hand focus points: DC-bus capacitors, IGBT modules, integrity of built-in braking chopper.

  1. Up-rated same-PM240 spare: 6SL3224-0BE15-5UA0 (0.55 kW FSA)

Same FSA frame, no filter, built-in braking chopper. Higher power rating supports derated operation for 0.37 kW motor. Mechanical installation identical with minimal parameter adjustment. 불리: 더 높은 비용.

III. Compact All-in-one Drive Replacement (Abolish split-type CU+PM architecture)

Original G120 is split power-module plus control-unit. Switch to monoblock G120C inverter, no separate CU required. Complete rewiring and PLC communication re-configuration needed.

6SL3210-1KE11-8UB2 (G120C, 0.37 kW, no integrated filter, 3-phase 380 V, built-in braking chopper)

메모: Form-factor different, cabinet cut-out modification needed. Terminal assignment fully revised; legacy CU cannot be reused.

  1. Domestic Functional Equivalent (비용 최적화, full re-commissioning required)

Suitable for new projects or full retrofit; existing CU discarded, control logic & communication re-engineered.

  1. Inovance MD290-0.37-T4: 3-phase 380 V, 0.37 kW, external braking-resistor support; V/F & 벡터 제어; Modbus capability, general-purpose for fans & 컨베이어.
  2. Inovance MD520-0.37-T4: High-performance vector drive.

Replacement Selection Comparison Table

해결책부품 번호Cabinet Cut‑outWiring Modification일반적인 응용
공식 업그레이드6SL3210‑1PE11‑8UL0FSA footprint compatibleMinor braking‑circuit re‑wiring새 프로젝트 & machine retrofit (첫 번째 선택)
Original Spare Stock6SL3224‑0BE13‑7UA0동일한Zero modificationEmergency breakdown repair
Up‑rated Same‑series Spare6SL3224‑0BE15‑5UA0동일한Zero modificationTemporary backup when original spare unavailable
All‑in‑one G120C6SL3210‑1KE11‑8UB2Cut‑out modification requiredComplete re‑wiringEliminate split‑module hardware
국내 대안Inovance MD290‑0.37‑T4New cut‑outComplete re‑wiringCost‑reduced new‑build / full retrofit

⚠️ Critical Replacement Notes

  1. PM240-2 (6SL3210-1PE11-8UL0): Braking-resistor terminal labels changed. Legacy PM240 uses DC-/ R2; PM240-2 uses R1/R2. Strictly follow manual; mis-wiring destroys braking power device.
  2. Original unit without built-in EMC filter. Select -UL0 for replacement. -AL0 (필터 포함) may trigger interference faults under poor earthing conditions.
  3. CU parameters can be uploaded/downloaded to PM240-2, but verify motor maximum current and braking parameters after replacement.

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요