K40061 = Custom OEM part number for Vega450 unit, not a standard model. This power unit is manufactured in the UK, a 450W pluggable multi-output modular 전원 공급 장치, widely deployed in semiconductor equipment, test & measurement instruments and medical devices.
- 기본 전기 사양
| 목 | 명세서 |
| Rated Total Power | 450여 |
| AC 입력 | 90~264VAC, 47–63Hz, built-in PFC, typical power factor 0.99 |
| 입력 퓨즈 | Built-in 16A fast blow fuse (non-user-replaceable) |
| Output Architecture | 최대 지원 5 pluggable output modules, 최고 11 independent outputs; No minimum load requirement (critical feature for repair) |
| Voltage Range per Module | 1.8V~64V adjustable, max current up to 120A per module |
| 전체 치수 | W126.5mm × H62.8mm × D268.4mm |
| 작동 온도 | 0~65°C, 강제 공랭 (내장 팬; forward/reverse fan optional) |
| 안전 인증 | IEC62368-1; medical version optional IEC60601-1, UL/CE/CB certified, compliant with MIL-STD-810 vibration & shock standard |
| Standard Signals | DC-Good (PG Power OK signal), Global Inhibit, AC Fail, Module Current Share, Remote Sense |
| 보증 | 3-year factory warranty. Most custom configurations of this series are NRND (Not Recommended for New Design). Only inventory stock & replacement repair parts available on market. |
- 모델 명명 규칙 (Vega450)
V4 = Vega450 (V6=650W, V9=900W)
냉각: F=Forward airflow; R=Reverse airflow; Q=Quiet; CB=Fanless
종료: S=Screw terminal; F=Fast-on connector; IE=With IEC input switch
누설 전류: S=Standard; L=Low leakage (common for medical applications)
Option Board: F=Fault Inhibit; E=Enable; W=Programmable Standby
Suffix string: Codes for each output module (B1S, C3, D2, E1, 등.)
Kxxxx (K40061): Custom OEM part number assigned by TDK for system integrators. It binds the complete set of module combination, fan and signal board configuration.
중요사항: Units marked K40061 from different equipment OEMs may have different module combinations; Never purchase replacement unit solely by K40061. You must verify the model of every output module.
- Output Module Types (Common across Vega Platform)
B Series: Low voltage high current (1.8~5V)
C 시리즈: 중간 전압 (9~31V)
D 시리즈: 넓은 전압 범위 (3.8~21.5V)
E Series: High current wide voltage modules
Modules can be hot-plug replaced individually. Only the faulty output module needs replacement instead of the entire power supply, which is the biggest advantage of this platform.
- Common Failure Points (유지보수용)
- Electrolytic capacitor aging inside output modules: Symptom – normal voltage at no load, voltage drop under load, flashing PG signal, intermittent protection (Most frequent fault)
- Swollen electrolytic capacitors on main PFC board
- Worn bearing of built-in fan, reduced airflow, over-temperature shutdown
- 산화 & poor contact on module socket, lost or fluctuating single-channel output
- Aged Inhibit / PG signal board; power supply fails to start with zero voltage on all outputs
Maintenance Warning: Before plugging/unplugging Vega modules, power off and wait for bulk capacitors to fully discharge to avoid electric shock. Module pin definitions cannot be arbitrarily interchanged.
- 예비 부품 & 교체 옵션
옵션 1: Original OEM Spare Parts (Priority for Repair)
- Complete Power Unit: Source stock Vega450 unit marked K40061; long lead time, high price and limited stock.
- Module-level Repair: Read each module model printed on the slot of power supply and purchase individual modules for replacement, 저렴한 비용.
옵션 2: Successor Platform Vega-Lite
Vega-Lite 550W, simplified next-generation version; Chassis, pin assignment and modules are NOT directly plug-and-play compatible. Rewiring and mounting hole modification required.
Option3: New Modular Power Supply for Retrofit (New Project Modification)
TDK-람다 QM Series: New generation multi-output modular power supply with PMBus, functional equivalent to Vega
국내 대안: Zipper, Meanwell modular multi-output power supply; shorter lead time and lower price. 불리: PG/Inhibit signal logic and mounting dimension differ, rewiring required, not direct drop-in replacement.
- Label Information to Extract
- Full Vega450 model (V4FSSF……)
- Model of each output module (예를 들어. B1S, C3)
- 출력 전압 & current of every channel
- Fan type (앞으로 / Reverse airflow)
- Target equipment (SMT mounter / Semiconductor tester?)
Overview of TDK-Lambda Vega450 Output Modules
Vega450, Vega650, Vega900 share mutually compatible module hardware. Vega450 chassis accepts maximum 5 pluggable modules; singlee single/dual-output, 최대 11 outputs in total. Voltage coverage: 1.8V~64V, maximum current 114A, No minimum load requir module can bement.
Module naming rule: Prefix B/C/D/E/F/H/L/W/Z + number + L/H (L=Low voltage version, H=High voltage version); suffix S = screw terminal, F = fast-on terminal
B Series (Low Voltage Modules, 1.8~16.2V)
| 모델 | 전압 범위 | 정격전류 |
| B1L | 1.8~3.8V | 20에이 |
| B1H | 3.9~5.5V | 20에이 |
| 지하 2층 | 5~9V | 25에이 |
| B3 | 9.1~16.2V | 12에이 |
C 시리즈 (Medium Voltage Single Output Modules)
| 모델 | 전압 범위 | 정격전류 |
| C1 | 1.8~4.1V | 35에이 |
| C1Y | 1.8~4.1V | 40에이 |
| C3 | 9.1~16.2V | 18에이 |
| C4 | 16.3~21.5V | 14에이 |
| C5 | 21.6~31V | 10에이 |
D 시리즈 (Wide Voltage Modules)
| 모델 | 전압 범위 | 정격전류 |
| D1L | 1.8~3.8V | 50에이 |
| D2 | 3.8~9V | 45에이 |
| D3 | 8~16.5V | 24에이 |
| D4 | 14~21.5V | 18에이 |
| D5 | 21~28V | 15에이 |
E Series (High Current Low Voltage Modules)
| 모델 | 전압 범위 | 정격전류 |
| E1 | 1.8~3.8V | 60에이 |
| E2 | 3.8~8V | 60에이 |
| E3L | 8~13V | 36에이 |
| E3H | 14~15V | 36에이 |
F 시리즈 (Ultra-high Current Low Voltage Modules)
| 모델 | 전압 범위 | 정격전류 |
| F1 / F1a | 1.8~3.8V | 80에이 |
| F2 / F2a | 3.8~8V | 80에이 |
H 시리즈 (Dual-output Modules, 널리 사용되는)
One module delivers two independent outputs, saving slot space. H modules are commonly used in OEM power supplies such as K40061
H1L/1L: 1.8~3.8V 12A / 1.8~3.8V 8A
H1L/1H: 1.8~3.8V 12A / 3.9~5.5V 8A
H1H/1L: 3.9~5.5V 12A / 1.8~3.8V 8A
H1H/1H: 3.9~5.5V 12A / 3.9~5.5V 8A
H2, H3 series: Medium voltage dual outputs from 5.6~25V
엘 / 여 / Z Series
L1: 4.2~5.5V, 35에이
W Series: High voltage modules, up to 62~64V, suitable for 24V/48V outputs
Z Series: Parallel composite modules. Two identical Vega modules pre-paralleled internally for higher output current (Z2/Z3/Z4/Z6, max 114A)
✅ Key Notes for Maintenance & 예비 부품 조달
- Modules can be replaced individually, no need to replace whole Vega450 unit; but Modules cannot be cross mixed (B module cannot replace C module)
- Suffix L/H must not be ignored: B1L and B1H differ in hardware and voltage range. Wrong replacement causes abnormal output and OVP protection.
- Total power limit of Vega450 chassis: 450여. Sum power of all installed modules cannot exceed 450W; Vega650 max 650W, Vega900 max 900W
- High failure rate modules: H dual-output modules, B1H (5다섯). Internal electrolytic capacitor aging is the most typical fault.
- K40061 is a fixed module configuration of Vega450. When repairing, quote directly by the module model printed on the power slot (예를 들어. H1L/1H), instead of using K40061 only.
보충: Module Terminal Types
에스: 나사식 터미널 (Mainstream for industrial & 반도체 장비)
에프: Fast-on connector terminal
Parallel Application of TDK-Lambda Vega450 Output Modules
✅ Parallel connection is available, but direct external wiring parallel is not allowed. The official qualified solution is Z module (Factory pre-paralleled with built-in active current sharing). Standard modules are NOT recommended for field direct parallel.
- Two Parallel Modes
① Z Module (Official Standard Parallel Solution, widely used in K40061 equipment)
Z module = Two identical standard Vega modules pre-paralleled at factory, equipped with built-in active current sharing bus and busbar. Current matching is completed before delivery to increase output current.
Example Z7 = D3+D3 parallel, 8~16.5V, total 45.6A
요구사항: Two modules of exactly same model, mounted on adjacent slots, internal current sharing wiring pre-connected
특징: Even load sharing, protection interlock, officially approved solution. Specify Z module during ordering. Finished power supply comes as a single Z module instead of two discrete modules wired on site.
Essentially, Z module integrates two same modules in parallel. Total current ≈ double of single module. Total power shall not exceed Vega450 limit of 450W.
② Manual Field Parallel (⚠️ Not recommended by OEM, use cautiously for repair & modification)
Standard B/C/D/E/H discrete modules are not recommended to directly parallel output terminals on site:
- Standard modules have no external current share pins. Hard parallel connection leads to severe current imbalance. One module bears most load, resulting in overheating, OVP/OLP protection or burnt module.
- If modules are equipped with N option (current share option), same-model modules can be paralleled with current share signal wiring; prerequisites:
Two modules identical model & same batch
Installed on adjacent slots
Star-point current sharing signal wires and Remote Sense sampling wires connected synchronously
Positive/negative output cables with strictly same gauge & 길이
Total power consumption under load shall not exceed Vega450 450W limit
Most legacy OEM power supplies such as K40061 have standard modules without N current share option, cannot be paralleled on site.
- Critical Limitations (For Repair & 예비 부품)
- Different model modules must never be paralleled (B module cannot parallel C module). Different voltage ranges cause reverse current and module damage.
- H dual-output module: The two channels inside one H module cannot be paralleled mutually. One channel of H module can only parallel single channel of another identical module (N current share option required).
- Chassis power constraint: Vega450 max 450W. Total power after parallel counts towards chassis power budget and must not exceed 450W.
- Protection interlock: After parallel, Inhibit and Module Good signals need series connection to ensure synchronous start/stop and synchronous latch on fault.
- Remote Sense: For parallel application, remote sensing wires of both modules must connect to the same sampling point on load, otherwise voltage imbalance occurs.
- Practical Maintenance Recommendation (For your K40061 Power Supply)
- If higher output current required: Check whether original configuration uses Z module. When Z module fails, purchase complete Z module replacement. Do not build parallel combination manually from discrete modules.
- Adding new parallel channels on legacy Vega450 is not advised: High aging risk of main board and fan. EMC & safety certification will be invalid after modification. Semiconductor machine vendors usually reject such modification.
- Emergency bench test: Never power up parallel modules under no load / 가벼운 부하, circulating current may damage modules.
- Parallel vs Series Distinction
평행한: Voltage unchanged, current doubled (Z module)
시리즈: Current unchanged, voltage stacked (BB/CC/DD combined modules, different concept from parallel)