The mechanical action indicator of the Omron MY4N-GS-R miniature power relay is one of the core practical designs of this model, with three main functions as follows:

  1. Judge Contact Status Without Power Supply

The mechanical action indicator is a physical component linked to the relay contacts, which will switch positions synchronously with the closing/opening of the contacts. During power-off maintenance and circuit debugging of equipment, there is no need to connect the control power supply. By visually observing the position of the indicator, you can quickly determine whether the relay contacts are in the Normally Open (아니요) or Normally Closed (NC) state, greatly improving maintenance efficiency.

  1. Quickly Locate Fault Points

During troubleshooting of the control system, the fault type can be judged by comparing the status of the mechanical indicator with the status of the LED indicator light:

If the LED light is on (코일에 전류가 흐르고) but the mechanical indicator does not act → it is highly probable that the relay coil is energized but the contacts are stuck or the mechanical structure is faulty.

If the LED light is off but the mechanical indicator acts abnormally → the contacts may be stuck by external force, or there may be a mis-trigger caused by a short circuit in the circuit.

  1. Simplify the Inspection Process of Multi-relay Parallel Control

In scenarios where multiple MY4N-GS-Rs work in parallel in an industrial control cabinet, inspectors do not need to measure the coil voltage or contact on-off status one by one. By scanning the positions of the mechanical indicators, they can quickly confirm the working status of each relay, reducing the maintenance cost of batch equipment.

Omron MY4N-GS-R Mechanical Indicator and LED Indicator Light Status Comparison Table

This table is used to quickly judge the working status and fault type of the relay. Among them, the LED of the AC coil is orange, and the LED of the DC coil is green.

Coil TypeLED Indicator Light StatusMechanical Indicator StatusCorresponding Working ConditionFault Troubleshooting Direction
AC/DCOn (corresponding color)Actuated (deflected synchronously with contact closure)Normal operationThe coil is energized, and the contacts have completed closing and switching
AC/DCOffReset (initial position)Normal power-offThe coil is not energized, and the contacts remain in the initial state
AC/DCOnReset (no action)Mechanical fault1. Contact jamming, mechanical structure damage
2. Insufficient magnetic force when the coil is energized (low voltage)
AC/DCOffActuated (deflected state)Mechanical jamming/mis-trigger1. The indicator or contacts are stuck by external force
2. The contacts are not reset before the equipment is powered off
3. Instantaneous short circuit in the coil circuit causes mis-closure
AC/DCFlashingAlternating between actuation and resetUnstable coil voltage1. Excessive voltage fluctuation of the control power supply
2. Loose coil wiring and poor contact
AC/DCOnActuated, but the load does not workContact fault1. Poor contact caused by contact ablation and oxidation
2. Wrong wiring or open circuit in the load circuit