DPSN250A-Honeywell Air Differential Pressure Switch

  Code Segment Meaning Remarks DPSN Product series code Honeywell Air Differential Pressure Switch series 250 Range identifier The actual standard model is 200 (20~200Pa); 250 is likely a typo A Version code Standard version, no special functions HONEYWELL Brand Honeywell (U.S. industrial automation giant) Core Specification Parameters Basic Parameters Parameter Value Description Product Type Air Differential ...

  • Product Details

 

Code SegmentMeaningRemarks
DPSNProduct series codeHoneywell Air Differential Pressure Switch series
250Range identifierThe actual standard model is 200 (20~200Pa); 250 is likely a typo
AVersion codeStandard version, no special functions
HONEYWELLBrandHoneywell (U.S. industrial automation giant)
  1. Core Specification Parameters

Basic Parameters

ParameterValueDescription
Product TypeAir Differential Pressure SwitchUsed for monitoring duct filters, fan operation and airflow status
Pressure Range20~200 PaStandard DPSN200A adjustable range
Switch Differential Pressure10 Pa (average)Pressure difference between actuation and reset
Max Working Pressure10,000 Pa (10 kPa)Ultimate withstand pressure
Accuracy≤±15%Measurement accuracy
Measured MediumAir, non-flammable and non-corrosive gasNot applicable for other media

Electrical Parameters

ParameterValueDescription
Switch Rating1.5 A (0.4 A)/250 VACRated electrical load capacity
Electrical ConnectionAMP connector or screw terminalTwo optional connection methods
Ingress ProtectionIP54Dustproof and splashproof, suitable for industrial environments
CertificationCECompliant with European safety standards

Mechanical & Environmental Parameters

ParameterValueDescription
Pressure Port Connection2 plastic tubes, 6 mm diameterFor connecting pressure sampling tubes
Cable Gland SizeCM = M20 × 1.5Cable interface dimension
Diaphragm MaterialSiliconeSensing element material
Mechanical Life>1,000,000 cyclesHigh durability
Operating Temperature-20℃ to 85℃Wide temperature range
Storage Temperature-40℃ to 85℃Storage ambient condition
Overall DimensionØ85.5 mm × 107 mmRound structure for easy installation
Mounting Holes4-ϕ3.6 mmFixing mounting holes
  1. Accessory List
Accessory NameQuantityPurpose
PVC Pressure Hose2 metersConnect differential pressure switch to air duct
Pressure Sampling Tube2 pcsConnect pressure ports
Mounting Screws5 pcsFix mounting bracket and main unit
L-type Mounting Bracket1 pcSupport multiple installation angles
Installation Manual1 copyGuide correct installation and commissioning
  1. Competitor & Cross-Brand Replacement Comparison
BrandModelMain DifferenceApplication Scenario
HoneywellDPSN200A (Standard Model)Original genuine, ±15% accuracy, IP54 protectionAll applications requiring DPSN250A
HoneywellDPS200Same series standard type, slight structural differenceGeneral air duct monitoring
Johnson ControlsP74JA-1Pressure range 15~200Pa, ±10% accuracyHVAC systems with high precision requirements
SiemensQBM81-3Adjustable range 0~500Pa, IP54Matching Siemens building automation systems
Schneider ElectricA9F7220020~200Pa range with LED indicatorApplications requiring status visualization
  1. Selection Guidelines & Replacement Solutions
  2. Key Selection Parameters

Confirm Pressure Range: Select according to actual duct differential pressure (20~200Pa for general filter monitoring)

Electrical Load Matching: Ensure switch rating meets control loop current requirement (≤1.5A/250VAC)

Installation Environment: IP54 suitable for non-humid industrial environments; additional protection required for outdoor use

Connection Method: Choose AMP connector or screw terminal based on site wiring requirements

  1. Recommended Replacement Solutions

Direct OEM Replacement: Prioritize DPSN200A (standard model) to avoid model confusion

Range Expansion: For higher pressure requirements, select DPSN400A (40~400Pa) or DPSN1000A (200~1000Pa)

Function Upgrade: Choose alternative models with LED status indicator for convenient on-site diagnosis

Cost-Effective Alternative: Domestic brands such as Chint and Delixi, price about 1/3~1/2 of OEM, performance meets general applications

  1. Installation Precautions
  2. Vertical mounting is standard; range value increases by 20Pa when mounted horizontally
  3. Avoid bending pressure sampling tubes; maximum length no more than 2 meters
  4. Connect pressure port +P1 to high-pressure side, -P2 to low-pressure side
  5. Electrical wiring shall comply with safety regulations to prevent short circuit

Honeywell Air Differential Pressure Switch Model List & Selection Guide

  1. Product Series Overview

Honeywell air differential pressure switches are mainly divided into 4 core series, covering general HVAC to heavy-duty industrial applications. All feature high reliability, long service life and IP54 ingress protection, suitable for duct filter monitoring, fan status detection and airflow control.

SeriesPositioningStructural FeaturesTypical Applications
DPS SeriesGeneral Air Differential Pressure SwitchStandard round design, manually adjustableCommercial building HVAC, filter monitoring
DPSN SeriesEconomy Air Differential Pressure SwitchSimplified design, cost optimizedOrdinary ventilation systems, basic filter monitoring
DPSP SeriesHigh Precision Air Differential Pressure SwitchPrecision adjustment, low hysteresisClean rooms, laboratories, medical facilities
AFS SeriesAirflow Proof SwitchUsed with sampling tubes, measures positive/negative pressureFire smoke exhaust system, damper status monitoring
  1. Detailed Model List by Series
  2. DPS Series (Standard Air Differential Pressure Switch)

Core Features: Manually adjustable setpoint with Pa scale dial, 180° rotatable pipe inlet, CE certified, IP54 protection

ModelPressure Range (Pa)Switch Differential (Pa)Max Working Pressure (Pa)Application Scenario
DPS 20020~2001010,000General filter, small fan
DPS 40040~4002010,000Medium filter, fan status
DPS 1000200~10005010,000Large air duct, high wind speed system
DPS 2500500~250015010,000High differential pressure system, industrial ventilation
DPS 200A20~2001010,000Standard type with AMP connector
DPS 400A40~4002010,000Standard type with AMP connector
DPS 1000A200~10005010,000Standard type with AMP connector
DPS 2500A500~250015010,000Standard type with AMP connector
  1. DPSN Series (Economy Air Differential Pressure Switch)

Core Features: Simplified structure, cost-effective, manual adjustment and IP54 protection, ideal for budget-sensitive projects

ModelPressure Range (Pa)Switch Differential (Pa)Electrical ConnectionRemarks
DPSN 200A20~20010AMP / Screw TerminalMost common model, replaces DPSN250A
DPSN 400A40~40020AMP / Screw TerminalMedium system application
DPSN 1000A200~100050AMP / Screw TerminalLarge air duct monitoring
DPSN 2500A500~2500150AMP / Screw TerminalHigh differential pressure industrial use
  1. DPSP Series (High Precision Air Differential Pressure Switch)

Core Features: Higher accuracy (≤±10%), lower switch differential pressure, suitable for strict pressure control scenarios

ModelPressure Range (Pa)AccuracySwitch Differential (Pa)Application Scenario
DPSP 10010~100≤±10%5Clean rooms, laboratories
DPSP 20020~200≤±10%8Medical facilities, precision air conditioning
DPSP 50050~500≤±10%15Pharmaceutical industry, electronic workshops
  1. AFS Series (Airflow Proof Switch)

Core Features: Detects positive / negative / differential pressure; used with sampling tubes for fire protection and energy management systems

ModelPressure Range (Pa)Reset ModeApplication Features
AFS 10025~100Manual / AutoDamper status monitoring
AFS 20050~200Manual / AutoFire smoke exhaust system
AFS 500100~500Manual / AutoAirflow proof for large ventilation systems
  1. Special Application Series

DPSL Series: Liquid & Gas dual-purpose differential pressure switch, suitable for neutral / slightly corrosive liquids and non-flammable gases, can be used as flow switch

ModelPressure RangeMedium TypeIngress Protection
DPSL 060.2~6 barLiquid / GasIP65
DPSL 160.5~16 barLiquid / GasIP65
DPSL 401~40 barLiquid / GasIP65
  1. Model Naming Rule Explanation

Honeywell air differential pressure switch model consists of Series Code + Range + Version Code, clearly reflecting core parameters:

Code SegmentMeaningExample
DPS/DPSN/DPSP/AFSSeries codeDPS=Standard, DPSN=Economy, DPSP=High Precision, AFS=Airflow Proof
200/400/1000/2500Range identifier200=20~200Pa, 400=40~400Pa, 1000=200~1000Pa, 2500=500~2500Pa
AVersion codeStandard version with AMP connector, screw terminal optional
Numeric SuffixSpecial functione.g. 06 in DPSL 06 means max 6 bar range
  1. Core Specification Comparison Table

General Electrical Parameters (All Series)

ParameterValueDescription
Switch Rating1.5 A (0.4 A)/250 VACRated electrical load capacity
Electrical ConnectionAMP connector or screw terminalTwo optional connection methods
Ingress ProtectionIP54Dustproof and splashproof for industrial environments
Operating Temperature-20℃ to 85℃Wide temperature range
Storage Temperature-40℃ to 85℃Storage ambient condition
Mechanical Life>1,000,000 cyclesHigh durability
Pressure Port Connection2 plastic tubes, 6 mm diameterFor pressure sampling tube connection
Cable Gland SizeCM = M20 × 1.5Cable interface dimension

Series Range & Accuracy Comparison

SeriesTypical Range (Pa)AccuracySwitch Differential (Pa)Applicable Scenario
DPS20~2500≤±15%10~150General HVAC systems
DPSN20~2500≤±15%10~150Economy HVAC systems
DPSP10~500≤±10%5~15High precision control occasions
AFS25~500≤±15%10~30Airflow proof & fire protection systems
  1. Selection Guidelines & Replacement Solutions
  2. Key Selection Parameters

Pressure Range Matching: Select based on actual duct differential pressure (20~200Pa for filter monitoring; 40~400Pa for large fans)

Accuracy Requirement: ≤±15% for general use (DPS/DPSN); ≤±10% for high precision (DPSP)

Electrical Load: Ensure switch rating meets control loop current (≤1.5A/250VAC)

Installation Environment: IP54 for non-humid industrial areas; extra protection required for outdoor installation

Connection Method: Select AMP connector or screw terminal according to site wiring

  1. Recommended Replacement Table
Original ModelDirect ReplacementFunction Upgrade ModelBudget Alternative
DPSN250ADPSN200A (Standard)DPSP200 (High Precision)Domestic Chint / Delixi
DPS200DPS200A (With AMP Connector)DPSP200 (High Precision)Johnson Controls P74JA-1
DPS400DPS400ADPSP500Siemens QBM81-3
DPS1000DPS1000ADPSP500Schneider A9F72200
  1. Installation Precautions
  2. Vertical mounting is standard; horizontal mounting will increase range value by 20Pa
  3. Avoid bending sampling tubes; length shall not exceed 2 meters
  4. Connect +P1 to high-pressure side, -P2 to low-pressure side
  5. Electrical wiring must comply with safety standards to avoid short circuit
  6. Adjust setpoint only after system runs stably to ensure accurate measurement
  7. FAQ
  8. Difference between DPSN250A and DPSN200A: DPSN250A is non-standard; the actual standard model is DPSN200A (20~200Pa), 250 is a typo.
  9. How to choose the correct range: 20~200Pa for filter monitoring; 40~400Pa for fan status; 200~1000Pa or higher for large industrial ducts.
  10. IP54 Protection Definition: Dust-tight and protected against splashing water, suitable for indoor industrial environments.

Prev: