Ebmpapst D2D160-BE02-11 Double Inlet Forward-Curved Centrifugal Fan - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

 Ebmpapst D2D160-BE02-11 Double Inlet Forward-Curved Centrifugal Fan - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

electrical/

 Ebmpapst D2D160-BE02-11 Double Inlet Forward-Curved Centrifugal Fan

Exclusive Cooling Fan for ABB ACS800 High-Power Inverters German original ebmpapst AC external rotor centrifugal blower, high-static-pressure cooling fan for industrial applications Model Code Definition D2D: Series of double-inlet AC external rotor centrifugal fans 160: Impeller outer diameter = 160 mm BE02: Motor structure & winding version code 11: Revision number Derivative models such as ...

  • Product Details

Exclusive Cooling Fan for ABB ACS800 High-Power Inverters

German original ebmpapst AC external rotor centrifugal blower, high-static-pressure cooling fan for industrial applications

  1. Model Code Definition

D2D: Series of double-inlet AC external rotor centrifugal fans

160: Impeller outer diameter = 160 mm

BE02: Motor structure & winding version code

11: Revision number

Derivative models such as 12/14/16 feature different wiring and winding configurations and cannot be directly interchanged.

  1. Core Technical Specifications
ItemParameter
Power Supply230VAC / 400VAC, 50Hz
Rated Power700W
Rated Current2.2A @ 230V
Rotational Speed2700 rpm
ConstructionDouble inlet, forward-curved multi-blade impeller, integral galvanized scroll housing
BearingsBall bearings
Insulation ClassClass F
Protection ClassIP00 (motor without internal protection; must be installed inside cabinet)
Air VolumeApprox. 1195 m³/h
Noise Level64dB(A)
Net WeightApprox. 13kg
Built-in ProtectionTCO thermal cutout (opens on overheating)
Ambient Temperature-40℃ ~ +80℃
  1. Application Scope
  2. Main cooling fan for ABB ACS800 high-power inverters (Frame R7)

ABB spare part No.: 64650424

  1. Forced air cooling of high-power industrial drives, SVG, high-power UPS and industrial cabinets
  2. High-static-pressure air supply for HVAC and industrial equipment
  3. Installation & Wiring Guidelines
  4. Equipped with terminal block for three-phase AC power supply; DO NOT run directly on single-phase 220V power.
  5. Built-in thermal protection contact; the inverter monitors this circuit and triggers a fan fault if overheating or wire breakage occurs.
  6. Mounting orientation: align the scroll outlet with the inverter radiator; flange mounting holes match the ACS800 cabinet.
  7. Regular dust cleaning is mandatory; clogged dust causes airflow degradation, overheating and premature bearing failure.
  8. Cross-Series Comparison & Replacement Options
  9. Equivalent model: D2D160-CE02-11

Same 700W power, 1.9A current; different winding and terminal assignment. Not plug-and-play without rewiring.

  1. Factory long-life upgraded replacement: R3G225-RE07-25 (EC fan, official ABB maintenance spare). Requires modification of wiring and fault feedback circuit.
  2. Domestic replica versions: Lower cost, but inferior bearing service life, dynamic balance and TCO reliability compared with original units; only suitable for non-critical operating conditions.
  3. Common Troubleshooting
  4. Fan fails to start after power-up

Verify three-phase power supply and tight terminals; test TCO thermal cutout. An open TCO indicates thermal burnout and fan replacement is required.

  1. Abnormal noise & heavy vibration

Impeller dust buildup causing imbalance; bearing wear; impeller rubbing against scroll housing.

  1. Inverter reports fan fault

Fan stall / open TCO circuit; broken wiring; insufficient rotational speed.

  1. Insufficient airflow & frequent inverter overtemperature alarms

Clogged filter/radiator; speed decay; impeller wear.

  1. Maintenance & Replacement Notes
  2. Always order the full part number D2D160-BE02-11. The suffix 11 cannot be replaced with 12/14, otherwise mismatched pinout will lead to component damage after power-on.
  3. Cut power and discharge DC bus residual high voltage before replacement (ACS800 carries high DC residual voltage).

Operating Principle of D2D160-BE02-11 (ebmpapst 3-phase AC External Rotor Double-Inlet Forward-Curved Centrifugal Fan)

The assembly consists of three core components: 3-phase external rotor asynchronous motor + double-inlet forward-curved multi-blade centrifugal impeller + scroll housing. It works by electromagnetic drive combined with centrifugal aerodynamics, serving as the primary cooling fan for ABB ACS800 inverters.

Part 1: Motor Principle – 3-Phase External Rotor Asynchronous Motor

Conventional motors have stator outside and rotor inside; this fan adopts the reversed external rotor structure:

The stator is fixed in the central hub; the rotor with the impeller rotates around the fixed stator.

When three-phase alternating current flows into the stator winding, a rotating magnetic field is generated, inducing eddy currents inside the rotor cage. The electromagnetic torque drives the rotor and impeller to rotate.

Advantages: Compact structure, short overall length, high rigidity, directly coupled to the impeller without a separate shaft coupling.

Part 2: Airflow Principle – Centrifugal Air Intake & Pressurization

  1. Air enters axially from both sides (double inlet) of the impeller.
  2. The high-speed rotating forward-curved blades throw air outward radially under centrifugal force, increasing air pressure and velocity.
  3. The spiral scroll housing collects the high-speed airflow, converts kinetic energy into static pressure, and delivers concentrated high-pressure airflow out through the rectangular outlet to blow across the inverter heat sink.

CE02 Winding Group (Same Power, Different Winding – Long-Life Alternative Models)

Full Production Models

D2D160-CE02-01

D2D160-CE02-11 (long-life version, 1.9A, 700W, also listed as ABB spare No. 64650424)

D2D160-CE02-12

D2D160-CE02-13

D2D160-CE02-14

D2D160-CE02-15

D2D160-CE02-16

Other Models in the Same Series (Identical Dimensions, Different Motor Configurations – Not Interchangeable)

D2D160-BE01-XX

D2D160-CE01-XX

D2D160-BD02-XX

D2D160-CB02-XX

Any difference in the middle code (BE/CE/BD/CB) means different winding, current and wiring layout; direct replacement is prohibited.

Built-in Motor Model (Same Core for All Versions)

Motor assembly: M2D074-LA

All BE02 and CE02 variants share this identical external rotor motor; only winding lead-out terminals differ.

Model Interchange Summary

  1. Original model D2D160-BE02-11: Only interchangeable with BE02-11. BE02-12/14 or CE02-11 cannot be fitted directly.
  2. Original model D2D160-CE02-11: Only interchangeable with other CE02 suffix variants.
  3. The two-digit suffix only defines terminal pinout + TCO protection circuit. Airflow, static pressure and rotational speed remain identical (2700 rpm, 700W).

Corresponding ABB Inverter Spare Part Numbers

D2D160-BE02-11: 64650424 (original early batch version)

D2D160-CE02-11: 64650424 (later long-life maintenance alternative)

Dimensional Data of D2D160-BE02-11 (ebmpapst)

All BE02 / CE02 variants share identical outer dimensions; only electrical terminals differ.

Unit: mm

  1. Overall Main Dimensions
  2. Impeller diameter: φ160
  3. Maximum scroll outer diameter: 270
  4. Total overall length (air inlet to outlet direction): 323
  5. Overall height: 241
  6. Axial overall width (double air inlet): 225
  7. Rectangular air outlet opening: 163 × 153
  8. Outlet flange outer frame: 276 × 183
  9. Mounting Flange Dimensions (for fixing onto ACS800 radiator)

Flange outer outline: 276 (W) × 183 (H)

Mounting hole center distance: 260 × 165

Fastener screw size: M6

  1. Weight

Net weight of fan: ~13 kg

Gross weight with packing: ~14.5 kg

  1. Key Installation Reminders
  2. D2D160-BE02-11 and D2D160-CE02-11 share identical mechanical outline, mounting holes and air outlet; mechanical fitting is direct. However, wiring and TCO circuit differ, so rewiring is mandatory before power-up, otherwise the inverter will trigger a fault.
  3. No damping pads supplied; rigid flange mounting for ACS800 Frame R7.
  4. Terminal block is fitted on the side of the scroll; reserve clearance for the terminal box during installation to avoid squeezing the terminal strip.
  5. Shipping Package Size

Outer carton: 470 × 470 × 350 mm

Prev:

Leave a Reply

Leave a message