Omron single-phase SSR, integrated heat sink, DIN rail mount, zero-crossing type
✅ Model Code Explanation
G3PA: G3PA series solid state relay with integrated heat sink
2: Output voltage class AC24~240V
40: Rated output current 40A
B: Built-in heat sink, screw terminals
VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light
📋 Key Specifications
Input Side (Control Terminals A1/A2)
Rated input voltage: DC 5~24V
Operating voltage range: DC 4~30V
Max. input current: 7mA (25℃)
Pick-up voltage: ≤DC4V; Drop-out voltage: ≥DC1V
Output Side (Load Terminals)
Load voltage: AC24~240V, permissible range AC19~264V (50/60Hz)
Rated current: 40A @40℃; derate to 36A when tightly mounted side by side
Surge current withstand: 440A (60Hz, 1 cycle)
On-state voltage drop: ≤1.6V RMS
Leakage current: ≤20mA@AC200V
Trigger mode: Zero-cross switching (ideal for heating loads to reduce interference)
Isolation: Phototriac
Operate / release time: ≤ half cycle +1ms
Environmental & Mechanical
Mounting: DIN rail / screw mounting
Ambient temperature: -30~+80℃ (no condensation or icing)
Dielectric strength: AC4000V 1min; insulation resistance ≥100MΩ (DC500V)
Terminals: Screw terminals
Certifications: UL, cUL, VDE, CE
📌 Typical Applications
Electric heating tubes, industrial ovens, injection molding heating, hot air equipment, ON/OFF temperature control for single-phase resistive loads. Not suitable for high-frequency PWM, only for periodic zero-cross switching.
⚠️ Important Notes
- Use 40A rating for resistive loads; inductive loads (motors, transformers) require heavy derating.
- When multiple units are tightly installed side by side, derate current to 36A due to poor heat dissipation.
- Zero-crossing type: turns on and off only when AC voltage crosses zero. It suppresses EMI but cannot switch at random phase angles.
- Non-polarized DC input; can be driven directly by PLC or temperature controller with DC5–24V output.
- SSR has no mechanical contacts and cannot provide short-circuit protection. A fuse must be installed upstream.
🔁 Same Series & Alternative Models
G3PA-220B-VD: 20A / AC24-240V / DC5-24V
G3PA-260B-VD: 60A / AC24-240V / DC5-24V
G3PA-420B-VD: 20A / AC200-400V / DC12-24V
Domestic alternatives: 40A zero-cross SSR with integrated heat sink. Verify derating curve and surge rating before replacement.
G3PA-240B-VD (Zero-crossing, 40A, DC5–24V Controlled SSR) Application Scenarios
Core positioning: ON/OFF temperature control for single-phase AC24–240V resistive loads. DIN rail integrated heat sink, driven by temperature controllers or PLCs. Designed mainly for heating loads, zero-crossing for low EMI, capable of frequent switching. Not for high-frequency PWM or inductive loads such as motors.
🔥 Heating & Temperature Control (Primary Use)
- Industrial ovens, hot air circulation ovens, aging chambers, constant temperature cabinets, high-low temperature test chambers (electric heating tubes, quartz heating tubes)
- Injection molding barrel heating, extruder die heating, blow molding machine zone heating
- Hot press machines, hot stamping machines, heat transfer machines, heating plates for laminators
- Packaging machinery: heat sealers, hot cutting knives, shrink tunnel heating
- Food machinery: baking lines, hot air dryers, electric heating for sauce cooking, commercial ovens
- Water treatment: electric heating boilers, tank heating, pipe trace heating, defrost heating
- Vulcanizing machines, single-phase heating circuits for mold temperature controllers. (For 3-phase heating, use 3 units separately for each phase.)
🧪 Automation Equipment
- Environmental test chambers, constant temperature & humidity machines, electric heating sections of dehumidifiers
- Semiconductor / PCB production: drying lines, preheating stations for glue coating
- Lithium battery equipment: vacuum ovens, formation cabinet heating
- Textile printing & dyeing: setting machines, drying rooms, hot roller heating
- Printing machines: drying tunnels, auxiliary heating for UV systems
💡 Other Resistive Load Switching
- High-power halogen lamps, infrared heating lamp banks (resistive lamp loads)
- High-power electric heaters for cabinets and clean rooms
- Electric auxiliary heating modules for air conditioning / fresh air systems
Advantage: Zero-cross switching reduces inrush current and interference to temperature instruments, PLCs and power grid.
✅ Suitable Working Conditions
Frequent switching (several to tens of times per minute), avoid contact burnout and arcing of contactors
Driven by PID temperature controllers or PLC digital outputs (DC24V)
DIN rail installation inside control cabinets, compact space, built-in heat sink, no extra heat sink required
High isolation (4kV dielectric strength) and operation indicator for easy commissioning
Single-phase resistive heating loads, mainly AC220V, current ≤40A (derate to 36A when densely mounted)
❌ Not Recommended Applications (Selection Pitfalls)
AC motors, water pumps, transformers and other inductive loads: high starting surge may cause breakdown. Heavy derating or random-phase SSR / contactor is preferred.
High-frequency PWM dimming (tens of Hz or above): zero-cross SSR cannot perform phase-angle regulation.
Capacitive loads.
OMRON G3PA-240B-VD Selection Guide & Application Notes (Product Page Version, Chinese + English)
Optimized for bestcontactor foreign trade website, readable for engineers, buyers and procurement, E-E-A-T compliant.
- Selection Checklist — Confirm the 4 Items Before Choosing G3PA-240B-VD
✅ Load type: Single-phase resistive load preferred (heating tubes, infrared heaters, heating plates)
✅ Load voltage: AC 24~240V (AC220V most common)
✅ Control signal: DC 5~24V (PLC DO, PID temperature controller output)
✅ Mounting: DIN rail inside cabinet, integrated heat sink
If not satisfied — Recommended Alternatives
- Inductive loads (motors, solenoid valves, transformers)
Not recommended for this model. Use contactors or random-phase SSR with at least 50% current derating.
- 3-phase heating loads
Solution: 3 pcs G3PA-240B-VD to control each phase independently. Do not use one unit for 3-phase load.
- Power regulation, phase-angle dimming, high-frequency PWM
G3PA is zero-cross SSR, only for ON/OFF cycle control, not phase-angle modulation. Choose OMRON G3PW power controllers if regulation is needed.
- Load current near 40A continuously, multiple units tightly arranged
Derate to 36A for dense mounting. Upgrade to G3PA-260B-VD (60A) if load current is continuously above 36A.
Load Current Formula (for foreign trade page)
Safe current for resistive load = rated load current × 1.25 safety margin
Multiply by 0.9 derating factor if densely mounted
Example: 3000W @AC220V heating tube, current ≈13.6A, sufficient margin for G3PA-240B-VD.
- Wiring Guide (Concise for Product Page)
Input (control): A1, A2, DC5~24V, non-polarized
Output (load): power in, load out; AC side non-polarized
Built-in operation indicator: lights up when control signal is present for easy on-site commissioning
Isolation rating: AC4000V between input and output
Important: Fast fuse must be installed on upstream AC side. SSR cannot withstand short circuit and will be permanently damaged.
- Application Notes
- Heat Dissipation & Derating
This model has integrated heat sink. Heat dissipation worsens at high cabinet temperature or when tightly mounted side by side; rated 40A derates to 36A. Keep ventilation inside cabinet. Sealed installation without airflow is prohibited.
- Zero-crossing Characteristic
The SSR turns on and off only when AC voltage crosses zero. Benefits: low inrush current and low EMI. Limitation: cannot switch at arbitrary phase angle, not for dimming or phase control.
- Leakage Current
Small residual leakage current (≤20mA @AC200V) exists in OFF state. Tiny loads may show faint heating or glowing, which is normal for SSR. A bleeder resistor can be added to resolve this.
- Load Surge
Infrared lamps and quartz tubes have low cold resistance with high inrush current at power-on. This model withstands 440A (60Hz, 1 cycle). Select a higher current rating if surge exceeds this value.
- Ambient Conditions
Operating temperature: -30℃ ~ +80℃, no corrosive gas, condensation or dust accumulation. Dust and oil will clog heat sink and accelerate aging.
- Prohibited Operations
Do not test output short circuit; do not use directly for capacitive loads; avoid frequently surging inductive loads.
- Recommended Supporting Items
Fuse: ceramic fast fuse
Temperature controller: OMRON E5CC / E5EC PID controller
Alternative models: G3PA-220B-VD (20A), G3PA-260B-VD (60A)
Upgrade for power regulation: G3PW series power controller
- FAQ (for bottom of product page)
Q: Can G3PA-240B-VD control motors?
A: Not recommended. Zero-cross SSR has limited surge withstand and may fail under motor starting current. AC contactor is preferred.
Q: Why is the heating tube still slightly warm after SSR turns off?
A: It is caused by inherent leakage current of SSR, more obvious on small loads. Add a bleeder resistor.
Q: Can it be driven directly by PLC DC24V output?
A: Yes. Input power consumption is low (approx. 7mA), standard PLC output points can drive it.
OMRON Solid State Relay SSR Full Series (Foreign Trade Selection Version, Classified, including G3PA)
Classification: Integrated heat sink DIN rail type (first choice for cabinet heating), separate heat sink type, fault detection SSR, plug-in I/O miniature SSR, power controller (not regular SSR, often selected together), discontinued models marked.
- Integrated Heat Sink DIN Rail SSR (Most Common for Heating, including G3PA)
- G3PA (Slim integrated type, replaceable power module)
Single-phase, AC24–240V / AC200–480V, DC5–24V control, zero-crossing
G3PA-210B-VD: 10A
G3PA-220B-VD: 20A
G3PA-240B-VD: 40A (this model)
G3PA-260B-VD: 60A
G3PA-420B-VD: 20A, AC480V version
G3PA-430B-VD: 30A, AC480V version
G3PA-450B-VD-2: 50A, AC480V version
✅ Typical use: ovens, injection molding heating, mold temperature machines, PID ON/OFF temperature control
- G3PE (New compact integrated type, single-phase & 3-phase)
Single-phase: G3PE-215B / 225B / 235B / 245B; 3-phase G3PE-325B, G3PE-345B
Advantages: better surge tolerance, random-phase version available, suitable for some inductive loads and dimming
Mounting: DIN rail, single-phase / 3-phase heating circuits
- G3PJ (Low heat dense mounting type, 25A rating remains valid even 3 units tightly side by side)
G3PJ-225B, G3PJ-225B-PU (Push-in spring terminal)
For high-density control cabinets with multi-zone heating
- G3PH (High-current integrated type)
75A / 150A, AC240V, AC480V, for heavy heating loads
- G3PC (SSR with built-in fault detection)
Heater break detection and SSR short-circuit alarm output. Safety-critical heating control, preferred for test chambers and lithium battery ovens.
- G3PF (Smart CT current sensing SSR)
Built-in current transformer for real-time heating element break and short-circuit detection. For high-end equipment with alarm logging.
- Separate Heat Sink Type (No built-in heat sink, embedded installation, external heat sink required)
- G3NA (Classic universal model, large market stock)
Single-phase, 5A~90A, mainly zero-crossing
G3NA-205B / 210B / 220B / 240B / 260B
G3NA-410B / 420B / 440B / 460B (AC480V)
G3NA-290B (90A high current)
Suffix: -VD = DC5–24V control; models without B are random-phase type
- G3NE (Economical low-current, 5A/10A/20A, quick connect terminals)
Low cost, small heating loads, infrared lamps, embedded inside machines
- Plug-in / I/O Mini SSR (Same footprint as MY/LY relays, signal and small load switching)
G3F / G3FD: MY relay size, socket mount, small AC/DC loads
G3H / G3HD: LY power relay size
G3R-I/O: G2R footprint I/O isolation SSR
G3RV-ST: 6.2mm slim DIN rail I/O SSR, high-density PLC isolation output
G3TA: SSR matched with G7TC I/O terminal blocks
G3RZ: MOSFET type, AC/DC low-power loads
- Power Controllers (Power regulators, not regular ON/OFF SSR)
Phase angle control, cycle control, soft start, for continuous power regulation
G3PW: Single-phase power controller (widely used for regulation instead of SSR)
G3ZA: Multi-channel power controller
G32A-EA: Cycle control unit
- PCB Mount SSR (Soldered on PCB, signal switching)
G3S, G3M, G3DZ, G3TB etc. Low current, signal isolation, used inside control boards
- Discontinued Models (Frequently asked in foreign trade inquiries)
G3PB, G3NH, G3B/G3BD, old G3RV-SR. Not recommended for new designs; only for spare replacement.
✅ Quick Selection Table (Can be placed directly on product page)
| Series | Heat Sink Type | Current Range | Key Features | Typical Applications |
| G3PA | Integrated DIN rail | 10~60A | Slim, zero-crossing, replaceable power core | Injection molding, ovens, general heating |
| G3PE | Integrated DIN rail | Single / 3-phase 15~45A | Better surge resistance, random-phase option | Heating, partial inductive loads |
| G3PJ | Integrated DIN rail | 25A | No derating when densely mounted | Multi-zone dense control cabinets |
| G3PH | Integrated DIN rail | 75/150A | Extra high current | High-power heating |
| G3PC / G3PF | Integrated DIN rail | 25~45A | Fault detection & alarm | Lithium battery ovens, aging chambers, safety-critical equipment |
| G3NA | Separate heat sink | 5~90A | Universal, cost-effective | Embedded inside machines, external heat sink required |
| G3NE | Separate heat sink | 5~20A | Economical | Low-power heating |
| G3PW | Power regulator | – | Phase / cycle power control | Continuous temperature regulation |
📌 Suffix Meaning (FAQ for Foreign Trade)
VD: DC5~24V non-polarized DC input (G3PA-240B-VD uses this suffix)
B: Zero-crossing trigger
No B: Random-phase trigger (phase-angle switching, suitable for inductive loads)
PU: Push-in spring terminal
-2: 480V version
Contactor,circuit breaker,sensor,Encoder,PLC,Converter




















NH42-63-318x560.png)



