Order No.: 104775
It belongs to the CES-AZ series, a Transponder Non-Contact Safety Evaluation Unit (integrated safety relay). It adopts Unicode (single coding), which only recognizes the uniquely taught actuator. It supports up to 2 read heads.
Key Specifications
Max. number of read heads: 2 (CES-A-L… series read heads)
Safety level: Category 4 / PL e (EN ISO 13849-1)
Safety outputs: 2 relay safety outputs, each with 2 internally series-connected NO contacts for redundancy
Coding type: Unicode (single coding); only the last taught actuator will be identified.
Multi-code alternative: CES-AZ-UES-02B (Order No. 105140, Multicode)
Additional interfaces: Start button monitoring (falling edge detection), external contactor feedback loop, TST test input, DIA diagnostic output, O1/O2 semiconductor status outputs
Mounting: 35 mm DIN rail
Protection class: IP20 (only for cabinet installation)
Power supply: DC 24V (21~27V DC regulated power supply, ripple <5%)
Power consumption: Approx. 150 mA with relay energized
Terminals: Plug-in coded terminals, wire cross-section 0.25–2.5 mm²
Operating temperature: -20℃ ~ +55℃, no condensation, relative humidity ≤80%
Gross weight: 0.299 kg
HS Customs Code: 85364110
ECLASS: 27-27-24-03 Safety-related transponder switch
Terminal Definition
UB / 0V: DC24V power supply
J1, J2: Teach-in jumpers (to write actuator coding)
H11/H12, H21/H22: Signal for read head 1 & read head 2
SH1, SH2: Shield grounding for read heads
TST: Self-test input
S: Start button input (falling edge detection)
Y1/Y2: External feedback loop
13/14, 23/24: Two groups of safety relay outputs
DIA: Diagnostic output; O1/O2: Semiconductor status outputs for read heads
RESET pushbutton; LED indicators: Power, H1, H2, OUT safety status, DIA fault diagnosis
Series Comparison Table
| Model | Order No. | Read Head Quantity | Coding Type |
| CES-AZ-AES-01B | 104770 | 1 | Unicode |
| CES-AZ-AES-02B | 104775 | 2 | Unicode (this model) |
| CES-AZ-AES-04B | 104780 | 4 | Unicode |
| CES-AZ-UES-02B | 105140 | 2 | Multicode |
Application Scenarios
Core Feature
One evaluation unit monitors 2 safety gates/protection points simultaneously. The Unicode exclusive coding prevents bypass and replacement, ideal for high tamper-proof requirements. It works with non-locking CES read heads and locking CEM/CET safety interlocks (EN 1088).
- Machine Tool Industry (Most Common)
- Machining centers, CNC milling machines & lathes: Dual front + side safety doors. Immediate safe stop once any door opens. Paired with CET locking read heads to keep doors locked until spindle coasts to rest.
- Grinding machines, high-speed saws & punch presses: Two protective covers for high-speed rotating and reciprocating motions, meeting PL e safety requirements.
- Laser cutting & plasma cutting machines: Upper and lower material loading doors; laser emission is only enabled when both doors are fully closed.
- Automated Production Lines & Assembly Equipment
- Robot workcells (fencing): Two access gates for the robot enclosure; robot stops immediately if a gate opens during operation.
- Custom assembly machines, hydraulic presses & riveting machines: Front maintenance door + side material feed door with interlock logic.
- Conveyors, transfer machines & rotary lifting stations: Service access gate + bypass protection gate.
- Injection molding & die-casting machines: Mold safety door + barrel protective door with lock function to prevent opening during mold clamping and melt processing.
- Packaging, Printing, Lithium Battery & 3C Equipment
- High-speed packaging, laminating & slitting machines: Two rotary roller guard doors.
- Li-ion winding machines, electrolyte filling machines & formation cabinets: Dual chamber doors to prevent high-voltage hazards and mechanical pinch injuries.
- SMT placement machines, AOI testers & FPC equipment: Front and rear maintenance hatches.
Advantage: Non-contact design with no mechanical wear, long service life and resistance to dust and oil contamination.
- Material Handling & Warehouse Equipment
- Vertical elevators & lifts: Upper and lower level protective doors.
- Sorting systems & cross-belt sorters: Two fence service doors.
- Small AGV and tooling trolley cabin hatches.
- Food & Pharmaceutical Machinery (Cleanroom Use)
- Filling machines, bottle washers & sealing machines: Dual clean chamber doors.
- Sterilization equipment: Chamber door + service door. Non-contact design avoids jamming and is easy to clean with no mechanical friction.
Note: Select stainless steel food-grade read heads for this application.
- Test Benches & Laboratory Tooling
- High-voltage test stands & aging cabinets: Two safety hatches; Unicode coding prevents personnel from shorting safety circuits to access hazardous areas.
- Impact and durability test rigs: Dual protective enclosure doors.
Model Selection Guide (Critical)
CES-AZ-AES-02B (Unicode)
Only recognizes the last taught actuator. Anti-tampering priority. For machines with safety audits and strict anti-bypass requirements.
CES-AZ-UES-02B (Multicode)
Accepts any actuator of the same series. Only used for position monitoring; easier maintenance without re-teaching after actuator replacement.
02B = Max. 2 read heads; choose 04B for 4 safety gates.
Recommended Matching Read Heads
CES-A-LNN: Non-locking type, only for door position monitoring
CEM: Process lock for production process protection
CET: Personnel safety lock (door locked until machine stops coasting; EN 1088)
Unsuitable Applications
More than 2 independent safety doors (select 04B or safety PLC instead)
Multiple gates requiring separate logic and different stop sequences (use a safety controller)
Simple door monitoring without anti-bypass requirements (UES version offers better cost performance)
EUCHNER CES-AZ-AES-02B (Order No. 104775) Full Technical Data
Type: Unicode (single coding) non-contact transponder safety evaluation unit, max. 2 read heads
- Order & Coding Information
Order No.: 104775
Coding type: Unicode (unique coding); only the last taught actuator will be recognized to prevent bypass replacement
Supported read heads: 2 units (CES-A-L… / CEM / CET series)
ECLASS: 27-27-24-03
HS Customs Code: 85364110
- Safety Performance (EN ISO 13849-1 / EN IEC 62061)
Safety category: Category 4
Performance level: PL e
SIL rating: SIL 3
PFHd: 1.3×10⁻⁸
Mission time: 20 years
Safety architecture: Dual redundant relay safety outputs; each channel has 2 internally series-connected monitored NO contacts
- Electrical Parameters
- Supply voltage UB: DC 21~27V, rated DC24V (regulated power supply, ripple <5%), UL Class 2 power supply required
- Power consumption: Approx. 150 mA with relay energized (excluding load of monitoring outputs)
- Relay safety outputs (13/14, 23/24)
Rated insulation voltage: 250 V AC
Max. switching voltage: 250 V AC / 30 V DC
Continuous thermal current Ith: 8 A
AC-15: 6 A / 230 V AC; DC-13: 4 A / 24 V DC
- External feedback loop Y1/Y2
Loop current: 5~8~10 mA
Max. allowed loop resistance: 600 Ω
- Digital inputs (S Start, TST Test)
Low level: 0~2 V DC; High level: 15~27 V DC
- Semiconductor monitoring outputs O1/O2, DIA
Type: NPN transistor output, NOT safety outputs
Max. load current: 100 mA
- Terminals: Plug-in coded spring terminals, wire cross-section 0.25–2.5 mm²
- Recommended external fuse: Max. 8A gG
- Mechanical & Environmental Data
Overall dimensions: 114 × 99 × 45 mm
Housing material: PA6.6 engineering plastic
Weight: Approx. 0.25 kg
Mounting: 35 mm DIN rail (EN60715 TH35)
Protection class: IP20 (cabinet-only installation)
Pollution degree: 2
Operating ambient temperature: -20 ℃ ~ +55 ℃
Relative humidity: ≤80%, no condensation
Mounting position: Any orientation
- Interfaces & Indicators
Terminals: UB/0V power, H11/H12 (read head 1), H21/H22 (read head 2), SH1/SH2 shield, S Start, TST Test, Y1/Y2 feedback, 13/14 & 23/24 safety outputs, O1/O2 read head status, DIA diagnosis
Operating elements: RESET pushbutton, J1/J2 teach-in jumpers
LED indicators: Power, H1, H2, OUT safety status, DIA fault diagnosis
- Read Head Compatibility
Reliable operating distance Sar: Max. 26 mm (depends on read head model)
Compatible types: Non-locking door monitors CES-A-LNN / CES-A-LCA; process interlocks CEM; personnel safety interlocks CET (EN 1088)
- EMC & Compliance Standards
EMC standard: EN IEC 60947-5-3
Applicable standards: EN ISO 13849-1, EN IEC 62061, EN 1088 (for guard lock applications)
- Model Differentiation
CES-AZ-AES-02B: Unicode, anti-replacement, Cat.4 / PL e
CES-AZ-UES-02B (105140): Multicode, accepts any same-series actuator, easier maintenance
EUCHNER Safety Relay / Evaluation Unit Model & Order Number List
Two main product lines: ESM standalone safety relays (general-purpose) and CES-AZ transponder evaluation units (your target model), plus CES-AR series for serial connection.
Note: CES-AZ is a transponder decoding safety evaluation unit, generally referred to as a safety relay in the industry. All models meet Cat.4 / PL e (EN ISO 13849-1).
- ESM Series General Safety Relays (E-Stop, safety gate, two-hand control, contact expansion)
1) ESM-BA Non-Time-Delay Basic Modules (Cat.4)
| Model | Order No. | Description |
| ESM-BA201 | 85610 | 2 safety NO contacts, screw terminals |
| ESM-BA201P | 97226 | 2 safety NO contacts, plug-in terminals |
| ESM-BA301 | 85613 | 3 NO + 1 auxiliary contact, screw terminals |
| ESM-BA301P | 97230 | 3 NO + 1 auxiliary contact, plug-in terminals |
| ESM-BA701 | 97224 | 7 safety NO contacts, screw terminals |
| ESM-BA701P | 97225 | 7 safety NO contacts, plug-in terminals |
2) ESM-BT Time-Delay Modules (Cat.4, adjustable 1~30s; fixed-delay versions available)
| Model | Order No. | Description |
| ESM-BT401 | 90818 | 1 instantaneous + 3 delayed outputs |
| ESM-BT411 | 90819 | 2 instantaneous + 2 delayed outputs |
| ESM-BT411-20S | 90077 | 2 instantaneous + 2 delayed outputs, fixed 2s delay |
| ESM-BT421 | 90820 | 3 instantaneous + 1 delayed output |
| ESM-BT421-50S | 90094 | 3 instantaneous + 1 delayed output, fixed 5s delay |
3) ESM-2H Two-Hand Control Modules (EN574 / Type IIIC)
| Model | Order No. | Description |
| ESM-2H201 | 85620 | Two-hand control, 2 safety contacts |
| ESM-2H202 | 98345 | Two-hand control, 2 safety contacts |
4) ESM-ES Contact Expansion Modules (Non-delay, used with BA/BT main units)
| Model | Order No. | Description |
| ESM-ES301 | 85614 | 3NO + 1 auxiliary, screw terminals |
| ESM-ES302 | 85615 | 3NO + 1 auxiliary, 230V AC |
| ESM-ES303 | 85616 | 3NO + 1 auxiliary, 115V AC |
| ESM-ES301P | 90057 | 3NO + 1 auxiliary, plug-in terminals |
5) ESM-TE Time-Delay Expansion Modules
| Model | Order No. | Description |
| ESM-TE301 | 85617 | Delay expansion, adjustable 1–30s |
| ESM-TE303 | 85619 | Delay expansion, 230V AC |
| ESM-TE301-05S | 97223 | Fixed 0.5s delay expansion |
6) ESM Accessories
| Model | Order No. | Description |
| ESM-F-AK4 | 97194 | Screw terminal kit for ESM-P |
| ESM-F-KK4 | 97195 | Spring terminal kit for ESM-P |
- CES-AZ Series Transponder Evaluation Units (Unicode AES anti-tamper / Multicode UES general type)
AES = Unicode (only recognizes taught actuators, anti-bypass); UES = Multicode (accepts any same-series actuator, easy maintenance)
| Model | Order No. | Read Head Count | Coding Type |
| CES-AZ-AES-01B | 104770 | 1 | Unicode |
| CES-AZ-AES-02B | 104775 | 2 | Unicode (your model) |
| CES-AZ-AES-04B | 104780 | 4 | Unicode |
| CES-AZ-UES-01B | 105139 | 1 | Multicode |
| CES-AZ-UES-02B | 105140 | 2 | Multicode |
| CES-AZ-UES-04B | 105149 | 4 | Multicode |
| CES-AZ-ABS-01B | 100064 | 1 | Old Unicode version, Cat.3 |
III. CES-AR Serial Link Evaluation Unit (Max. 12 AR read heads wired in series)
| Model | Order No. | Description |
| CES-AR-AES-12 | 98225 | Up to 12 AR read heads in series, Cat.4 PL e |
Quick Selection Guide
- ESM-BA/BT: General safety relays for E-stop, regular safety gates and light curtains; no transponder decoding function.
- CES-AZ-AES: Transponder-only type, anti-replacement & anti-cheating; for machine tools and automation with strict anti-bypass requirements.
- CES-AZ-UES: Transponder-only type; no re-teaching needed after actuator replacement, preferred for mass-produced equipment.