(Elmo Rietschle / Formerly Siemens Rietschle) The 2BH1 series is the classic Side Channel ring blower. Oil-free dry operation, dual function for both positive pressure air supply and negative pressure vacuum suction. ✅ Model Code Explanation 2BH1 300 1 A H 16 2BH1: G-BH1 single-stage side channel blower series 300: Size group 1: Motor version ...

  • Product Details

(Elmo Rietschle / Formerly Siemens Rietschle)

The 2BH1 series is the classic Side Channel ring blower. Oil-free dry operation, dual function for both positive pressure air supply and negative pressure vacuum suction.

✅ Model Code Explanation

2BH1 300 1 A H 16

2BH1: G-BH1 single-stage side channel blower series

300: Size group

1: Motor version code (1=single-phase; 7=three-phase. Model 2BH1300-7AH16 three-phase version is more common on the market)

A: Motor construction

H: Standard construction

16: Flange / connection version

⚠️ Note: 2BH1300-1AH16 is single-phase 220V; 2BH1300-7AH16 is three-phase 380V. These two models are easily mixed up during model selection, many suppliers incorrectly list 1AH16 and 7AH16 together in product titles.

📌 Key Specifications (2BH1300-1AH16)

Type: Single impeller, single-stage side channel blower

Rated power: 0.4 kW

Power supply: Single-phase AC220V, 50Hz

Operation mode: Oil-free dry type, no contact or wear inside the pump chamber

Protection class: IP55, Class F insulation

Features: External bearings; bearings are isolated from the air flow chamber, suitable for continuous 24-hour operation

Function: Blow & suction dual purpose, positive pressure air delivery and negative pressure vacuum integrated

Material: Die-cast aluminum alloy pump body, lightweight and corrosion resistant

🛠 Typical Application Scenarios

  1. Packaging machinery: Vacuum gripping, suction cup material handling, bag blowing
  2. Water treatment: Aeration and oxygen enhancement, small sewage aeration
  3. Material conveying: Short-distance pneumatic conveying of fine particles and powder
  4. Printing & PCB equipment: Vacuum holding, air drying, air knife
  5. Industrial dust removal, waste gas extraction and gas transportation

✅ Product Features

  1. Oil-free air delivery: No medium contamination, applicable for food/pharmaceutical industries (with clean filter fitted)
  2. Pulsation-free output; no air receiver tank required
  3. Low-maintenance design. Original service life up to 20000 hours; only intake filter cleaning periodically required
  4. Variable frequency drive supported (0~87Hz speed regulation), adjustable flow and pressure
  5. Compact vertical integrated structure, small installation footprint

🔍 Troubleshooting Guide

  1. Insufficient pressure / flow: Prioritize checking clogged intake filter, pipeline air leakage and check valve failure
  2. Overheat shutdown: Check inlet temperature, overload condition, cooling fan dust accumulation and over-frequency VFD operation
  3. Abnormal noise: Bearing wear or foreign object entering pump chamber; stop machine immediately for disassembly inspection
  4. Motor overload: High backpressure caused by blocked inlet

📎 Alternative Solutions & Spare Parts

  1. Domestic replacement: Domestic 2HB series single-phase ring blower with same specification (0.4kW, single-stage). Matching connection dimensions with slightly different noise and pressure curve
  2. Same series upgrade: Three-phase counterpart 2BH1300-7AH16 (0.4kW). Pay attention to power rating difference; cannot directly replace without modification
  3. Regular spare parts: Intake air filter, pump chamber O-ring seal, bearing repair kit, vibration isolation pad

📌 Installation & Maintenance Guidelines

An air filter must be installed at the inlet to prevent dust entering the pump chamber; this is the most critical measure to extend service life

Flexible bellows are recommended at inlet and outlet for vibration isolation and reduce vibration transmission

Ambient temperature: 0~40℃, inlet medium temperature ≤40℃

Long-time closed dead-head operation is prohibited; it may cause overheating and motor burnout

Full Model List of 2BH1300 Series (Gardner Denver / Elmo Rietschle, Former Siemens G-BH1 Single-Stage Side Channel Blower)

Reference model: 2BH1300-1AH16 (Single-phase 220V); Digit 7 = three-phase 380V, digit 1 = single-phase 220V; suffix 06/16 = flange version, AH = standard pump body structure

  1. Regular Models within 2BH1300 Size Group
  2. 2BH1300-1AH06|Single-phase 220V, standard pump body, 06 port
  3. 2BH1300-1AH16|Single-phase 220V, standard pump body, 16 port (your target model)
  4. 2BH1300-7AH06|Three-phase 380V, standard pump body, 06 port
  5. 2BH1300-7AH16|Three-phase 380V, standard pump body, 16 port (most popular in market)
  6. 2BH1300-7AH01|Three-phase, small port version
  7. 2BH1300-7AH03|Three-phase, special flange
  8. 2BH1300-7AH07|Three-phase, special sealing version
  9. 2BH1300-7AB16|Three-phase, AB motor construction
  10. 2BH1300-7AC16|Three-phase, AC motor construction
  11. 2BH1300-7AD26|Three-phase, AD special construction
  12. 2BH1300-0AH11|Special explosion-proof / custom version
  13. 2BH1300-7AA01 / 7AA10 /7AA11|Three-phase AA motor series
  14. Regular Selection List of Full G-BH1 (2BH1) Family

2BH1 single-impeller side channel blower, sizes from small to large

2BH1100-7AH06

2BH1200-7AH06

2BH1300 series (list above)

2BH1330-7AH06 / 2BH1330-7AH16 / 2BH1330-7AH26

2BH1400-7AH06 / 2BH1400-7AH16 / 2BH1400-7AH26

2BH1410-7HH36 / 2BH1410-7HH46

2BH1430-7AH06 / 2BH1430-7AH16 / 2BH1430-7AH26

2BH1490-7AH16

2BH1500-7AH06 / 2BH1500-7AH16 / 2BH1500-7AH26 / 2BH1500-7AH36

III. Suffix Code Quick Reference

  1. 6th character: 1=Single-phase 220V; 7=Three-phase 380V
  2. A/H: Pump body structure code, AH = standard common structure (most widely used)
  3. Suffix 06/16/26: Inlet/outlet flange specification. 06 and 16 have different port dimensions and cannot be directly hard replaced
  4. BOM Spare Parts List for 2BH1300-1AH16
  5. Intake air filter assembly (external filter)
  6. Pump chamber O-ring
  7. Bearing repair kit (front & rear bearings)
  8. Rubber vibration isolation pads
  9. Silencer (inlet / outlet optional)
  10. Flexible connecting bellows
  11. Motor end seal
  12. Model Replacement Tips

2BH1300-1AH16 (single-phase) cannot directly replace 2BH1300-7AH16 three-phase model due to different power supply and winding

Same suffix (same 16) means identical flange dimension, only motor power supply differs; suffix 06 and 16 flanges are incompatible and pipeline modification required

Domestic reference series: 2HB1300 ring blower available for cost-down replacement

2BH1300 Series Parameter Table (Copy to Excel, 50Hz)

Brand: Gardner Denver (Elmo Rietschle, Former Siemens G-BH1 Side Channel Blower)

Remarks: 1=Single-phase 220V;7=Three-phase380V;06/16=Flange port;AH=Standard pump body

ModelPower SupplyRated Power(kW)Max Vacuum(mbar)Max Positive Pressure(mbar)Weight kg
2BH1300-1AH06Single-phase 220V0.251001168
2BH1300-1AH16Single-phase 220V0.411113010
2BH1300-7AH06Three-phase 380V0.251001168
2BH1300-7AH16Three-phase 380V0.411113010
2BH1300-7AH01Three-phase 380V0.251001168
2BH1300-7AH03Three-phase 380V0.251001168
2BH1300-7AH07Three-phase 380V0.411113010
2BH1300-7AB16Three-phase 380V0.411113010
2BH1300-7AC16Three-phase 380V0.411113010
2BH1300-7AD26Three-phase 380V0.41111301

Supplementary Selection Notes

  1. Within 2BH1300 group, pump body and impeller are identical, differences only lie in motor winding and flange port
  2. Outer diameter and thread specification differ between port 06 and port16; pipelines cannot be interchanged directly
  3. Performance curve: Vacuum and positive pressure are inversely proportional to flow rate. 80m³/h is maximum free delivery flow, maximum differential pressure achieved under closed condition
  4. IP55 protection, Class F insulation, continuous 24h operation; inlet medium temperature ≤40℃.

Application Scenarios of 2BH1300-1AH16 (Single-phase 220V,0.4kW,Side Channel Blower,Blow & Suction)

Core features: Oil-free clean air, low single-stage pressure, 80m³/h flow rate, single-phase power supply, suitable for small OEM machine integration, dual function for negative vacuum / positive blowing

  1. Packaging Machinery (Vacuum gripping as primary application)
  2. Vacuum cup material handling: Pick & place cartons, plastic sheets and thin plates
  3. Bag opening & bag making machine: Negative pressure to open bags, positive air to expand bag mouth
  4. Labeling machine: Label suction and conveying, bottle body air blow dedusting
  5. Tray sealing machine, small thermoformer for vacuum workpiece fixing
  6. Bottle drying: Air knife to remove residual water on bottle surface (positive pressure blowing)
  7. Printing & PCB Electronic Equipment
  8. Screen printing & pad printing machine: Vacuum table for paper/film holding
  9. Paper cutter & paper transport: Negative pressure suction to carry paper and prevent warping
  10. PCB equipment: Vacuum positioning for circuit boards, board drying and minor dedusting
  11. Vacuum platen for digital printing
  12. Environmental Water Treatment & Aquaculture
  13. Small integrated sewage, small flotation tank biochemical aeration
  14. Oxygen aeration for small fish ponds and breeding tanks
  15. Minor waste gas extraction and trace gas conveying (oil-free clean air)
  16. Material Conveyance (Light-weight material only)
  17. Small vacuum auto loader for injection molding machine: Short-distance pneumatic feeding of plastic pellets
  18. Short-distance vacuum conveying of food granules and powder (filter required)

Limitation: Low power rating, only for short-distance light load conveying, not applicable for long distance or heavy bulk material

  1. Food & Light Industry Equipment
  2. Fruit & vegetable washing machine: Bubble washing and air blow dewatering
  3. Air assist for food conveying, degassing for food packaging
  4. Textile machinery: Yarn blowing, fabric adsorption, air for setting process
  5. Other Small Industrial Equipment
  6. Negative pressure air source for dental and small medical equipment
  7. Mold cooling, workpiece drying, air curtain isolation
  8. Small vacuum source and gas circulation in laboratory
  9. Small central dust extraction, air blow to remove workpiece chips

✅ Application Boundary for Model Selection (Important)

Advantages: Single-phase 220V easy site power access; oil-free clean air output; IP55 rated for 24h continuous duty

Limitation: 0.4kW with relatively low pressure, not suitable for high vacuum, long pipeline or high flow applications; designed for small OEM integration. Select high-power three-phase models (2BH1400/1500 series) for large production lines

Model Selection Notes

  1. Vacuum application: Air filter must be fitted at inlet to prevent dust entering pump chamber and damaging impeller
  2. Positive pressure blowing: Outlet silencer is recommended for noise reduction
  3. Medium temperature: Inlet air ≤40℃. Hot, oily or corrosive gas shall not be fed directly into blower

Cross-Brand Equivalent Replacement Table for 2BH1300-1AH16 (Gardner Denver/Elmo Rietschle,0.4kW Single-phase220V Single-stage Side Channel Blower)

Reference parameters:0.4kW / AC220V single-phase, max flow 80m³/h, max positive pressure130mbar, max vacuum111mbar, blow & suction dual purpose, IP55, single impeller side channel

⚠️ Remark: No fully identical OEM substitute. Classified as [intra-brand replacement, imported competitor equivalent, domestic alternative]. Flange and base mounting dimensions will have minor deviations. Verify port size and mounting hole pitch before replacement.

  1. Intra-brand / Group Replacement (Most reliable, identical performance curve)
Original ModelReplacement ModelRemarksDifficulty
2BH1300-1AH162BH1300-7AH16Only motor power supply differs, pump, impeller and flange identical. 7AH16 is three-phase 380V. Pipeline and base can be reused only after power circuit modificationMedium (Power wiring change)
2BH1300-1AH162BH1300-1AH06Same single-phase 0.4kW with same performance; port flange 06≠16, inlet/outlet size different, pipeline modification neededMedium (Pipe adapter required)
  1. Imported Competitor Equivalents (German Side Channel Blower Brands)
BrandEquivalent ModelMatching PointsDifference & RiskDifficulty
ElektrorSD40 (Single-phase220V)0.4kW single-stage side channel, close flow and pressure, oil-free blow/suctionOutline and base flange different; base and pipe adapter modification required; slight difference in noise curveHigh, mechanical modification needed
SKV-tecSKV80-S Single-phase version80m/h flow, similar pressure differential, equivalent to Rietschle G-BH1Mounting dimension not fully matched; mainly for new machine design, retrofit replacement requires base reworkHigh

III. Main Domestic Alternatives (Preferred for spare parts cost reduction, widely used for industrial OEM)

Domestic BrandEquivalent ModelDescriptionDifference & RiskDifficulty
Full 风 (RB Series)RB-400AS (Single-phase 220V,0.4kW)Most common domestic alternative, 0.4kW,80m³/h single-stage ring blower blow & suctionSimilar pressure curve; outline, base hole pitch and flange not fully identical, flange adapter required in most cases; noise slightly higher than Rietschle, shorter bearing life. Suitable for vacuum holding, aeration, air drying non-critical applicationsMedium, usually with flange adapter
GAORUI2RB 400A Single-phaseMatching power, flow and pressure, aluminum pump body, IP54~IP55Different base, higher vibration, obvious price advantageMedium
Liongo2LG400S0.4kW single-phase single-stage ring blower with matching parametersPump housing different, inlet/outlet flange to be verifiedMedium
Domestic 2HB Series2HB1300-1AH16 (Rietschle copy version)Replicate outline, flange and base dimension of 2BH1300High dimensional similarity for direct in-situ replacement. Minor deviation in performance curve; bearing & seal quality vary by grade. Select high-grade bearing version for spare emergency replacementLow (Recommended for emergency spare replacement)

✅ Replacement Selection Rules (Important)

  1. Match 4 core indicators first: Power supply voltage & phase → rated power → maximum flow → maximum differential pressure. Machine works only if all four match.
  2. Condition for direct in-situ replacement: Identical inlet/outlet flange dimension + base mounting hole pitch, no pipe or bracket rework required.
  3. Scenarios NOT recommended for domestic replacement: 24/7 continuous operation, high-precision vacuum control, food/pharma clean application and strict low-noise requirement. Keep original Elmo Rietschle blower.
  4. Forbid downgrade replacement: Never use 0.25kW model as substitute; insufficient vacuum and flow will cause machine failure.

📌 Auxiliary Spare Parts Recommended to Purchase Together for Cross-Brand Swap

  1. Flexible vibration bellows for inlet/outlet (compensate flange mismatch, vibration damping & noise reduction)
  2. Intake filter assembly matched to new blower port
  3. Vibration isolation pads
  4. Flange adapter (required for most domestic alternatives)
  5. Silencer (optional)

Supplementary: 60Hz Overseas Application Note

Original model 2BH1300-1AH16 supports 50/60Hz. If replacement model is used for 60Hz overseas project, performance curve under 60Hz must be checked separately; 50Hz parameters cannot be directly adopted.

Prev:

Leave a Reply

Leave a message