Lenze E82EV552K4C Inverter - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

Lenze E82EV552K4C Inverter - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

solar inverter/

Lenze E82EV552K4C Inverter

E82EV552K4C is a 5.5kW three-phase inverter of Lenze 8200 Vector series. It accepts 380-480VAC input, delivers 13A output with IP20 protection grade. Built-in vector control and brake transistor, suitable for general industrial speed regulation applications. Model Code Definition Code Segment Description E82 Platform identifier for Lenze 8200 series inverters EV Vector control, supports precise torque ...

  • Product Details

E82EV552K4C is a 5.5kW three-phase inverter of Lenze 8200 Vector series. It accepts 380-480VAC input, delivers 13A output with IP20 protection grade. Built-in vector control and brake transistor, suitable for general industrial speed regulation applications.

  1. Model Code Definition
Code SegmentDescription
E82Platform identifier for Lenze 8200 series inverters
EVVector control, supports precise torque and speed regulation
55Power rating code: 5.5kW (7.5HP)
2Frame size code: Size 2 housing (100×240×140mm)
KIntegrated EMC filter, compliant with EN 61800-3
4Input voltage class: 3-phase 400-500VAC (compatible with 380-480VAC)
CStandard control interface with RS232/485 communication port

Order Number: E82EV552K4C (Standard Model); E82EV552K4C200 (Extended Version)

  1. Main Technical Specifications
CategorySpecificationsRemarks
Basic Parameters
Rated Power5.5kW (7.5HP)Matches standard asynchronous motors
Input Voltage3-phase 380-480VAC, 50/60HzWide voltage design
Output Voltage3-phase 0-480VAC, same frequency as inputVector controlled output
Output Current13A rated, 150% overload for 60sStrong overload capability
Frequency Range0-599HzApplicable to high-speed motors
Control Performance
Control ModeVector control (Closed-loop V/F)High low-speed torque, ±0.5% precision
Speed Ratio0.111111111Stable wide-range speed adjustment
Torque ResponseLess than 100msFast dynamic response
Braking ModeBuilt-in brake transistor (≤11kW)Compatible with 75Ω/500W brake resistor
Physical Properties
Protection ClassIP20Indoor cabinet mounting only
Ambient Temperature-10℃ ~ +55℃ (derate above 40℃)Storage: -25℃ ~ +70℃
Relative Humidity5%-95% non-condensingKeep away from humid environment
Dimensions (W×H×D)100×240×140mmStandard size 2 housing
WeightApprox. 3.5kgLightweight structure
Communication & Functions
Standard InterfaceRS232/485 (Modbus RTU)Remote parameter configuration supported
Optional ModulesPROFIBUS, DeviceNet, etc.Compatible with industrial networks
Built-in FunctionsPID regulator, 4 parameter sets, energy saving modeMulti-scenario adaption
  1. Full E82EV Series Model List

3-phase 400V Series (Suffix K4C)

ModelPowerOutput CurrentSize CodeRemarks
E82EV222K4C2.2kW5.5A2Basic model
E82EV302K4C3.0kW7.5A2
E82EV402K4C4.0kW10A2
E82EV552K4C5.5kW13A2Current model
E82EV752K4C7.5kW18A2
E82EV113K4C11kW25A3Enlarged housing
E82EV153K4C15kW32A3

3-phase 230V Series (Suffix K2C)

ModelPowerOutput CurrentSize Code
E82EV251K2C0.25kW1.5A1
E82EV371K2C0.37kW2.0A1
E82EV551K2C0.55kW2.8A1
E82EV751K2C0.75kW3.8A1
E82EV112K2C1.1kW5.5A2
E82EV152K2C1.5kW7.5A2
E82EV222K2C2.2kW11A2

Extended Models (Suffix 200)

All standard models support 200 suffix, e.g. E82EV552K4C200

Enhanced C1-class EMC filter

Extended working temperature: -10℃ ~ +60℃

24-month warranty period

  1. Cross-brand Replacement Comparison
Lenze ModelSiemensSchneiderABBOmronReplacement Tips
E82EV552K4CMM440-5.5kWATV312HU55N4ACS550-01-012A-43G3RX-A4055Functions matched, note communication protocol difference
Main DifferencesRich parameter optionsCost-effectiveSuperior overload resistanceCompact dimensionReset parameters when keeping original motor
  1. Common Faults & Solutions
Fault CodeFault TypePossible CausesSolutions
F02OvervoltageExcessive input voltage, rapid deceleration1. Check grid voltage
2. Extend deceleration time
3. Install brake resistor
F05UndervoltageLow input voltage, power fluctuation1. Stabilize power supply
2. Inspect wiring
3. Equip voltage stabilizer
F08OverheatPoor heat dissipation, high ambient temperature1. Clean cooling fan
2. Improve ventilation
3. Operate under derated load
F13OvercurrentMotor short circuit, excessive load1. Check motor winding
2. Reduce load
3. Adjust current limit parameters
No DisplayPower failurePhase loss, internal power damage1. Verify 3-phase input
2. Test DC bus voltage
3. Replace power module
  1. Air Shipment Compliance & Certifications

Air Transport Assessment

Lithium Battery: Built-in electrolytic capacitor, no lithium battery, UN38.3 test exempted

Classification: Ordinary electrical equipment, non-dangerous goods

Packaging: Anti-static package, fixed firmly against collision

Documents: Commercial invoice, packing list, CE certificate

Certification List

CertificateStandardApplication Scope
CEEN 61800-5-1(Safety), EN 61800-3(EMC)EU market access
ULUL 508CNorth America
CSAC22.2 No.14Canada
CCCGB/T 12668.3China
RoHS2011/65/EUEnvironmental protection compliance

Shipment Instructions

  1. Disconnect all external connections before delivery
  2. Fix inside rigid container with cushion materials
  3. Avoid inversion and violent vibration
  4. Attach copies of certification documents
  5. Application Cases & Industry Adaptation

Typical Applications

Material Conveying: Speed control for belt and chain conveyors, over 30% energy saving

Fan & Water Pump: Constant pressure/flow PID control for central air conditioning and cooling towers

Machine Tools: Spindle drive, stepless speed regulation and fast start-stop

Packaging Machinery: Food and printing equipment, precise synchronous operation

Agitator Equipment: Chemical reactor stirring for variable viscosity materials

Industry Adaptation

IndustrySuitabilityAdvantagesNotes
Automobile Manufacturing★★★★★High reliability, quick responseReinforce EMC protection against interference
Food & Beverage★★★★☆Suitable protection grade, easy maintenanceKeep away from damp and corrosive atmosphere
Logistics & Warehousing★★★★★Excellent energy saving, easy maintenanceAdapt to frequent start-stop operation
Chemical Industry★★★☆☆Good temperature resistance, strong overload capacityOptional explosion-proof accessory required
Construction Machinery★★★☆☆Vibration resistance, harsh environment adaptabilityAdditional reinforcement installation

Practical Case

An auto parts factory adopts E82EV552K4C for stamping line conveyor:

Speed control accuracy improved to ±0.1m/min

Energy consumption reduced by 28%, annual power saving about 120,000 RMB

Equipment failure rate decreased by 40%, maintenance cost cut by 35%

  1. Selection Guidelines

Quick Rules

  1. Power Code: 55=5.5kW, 75=7.5kW, 11=11kW
  2. Voltage Identification: K4=400V, K2=230V
  3. Size Identification: 2=100mm width, 3=140mm width
  4. Core Function: EV=Vector control, K=EMC filter, C=Standard control
  5. Application Environment Requirements

Suitable Conditions

Installed inside industrial automation control cabinets

Ambient temperature: -10℃ ~ +40℃, dry, dust-free and non-corrosive air

Stable power grid with voltage fluctuation ≤±10%

Scenarios requiring precise speed and torque adjustment

Unsuitable Conditions

Outdoor or humid locations (insufficient IP20 protection)

Heavy dust and corrosive gas environment

Severe grid fluctuation over ±15% without stabilizer

Heavy load frequent forward/reverse operation without brake resistor

Installation Precautions for Lenze E82EV552K4C

  1. Cabinet Installation Space
  2. Vertical wall mounting only; horizontal, side or upside-down installation forbidden
  3. Reserve ≥100mm vertical clearance, ≥30mm lateral clearance for heat dissipation
  4. Minimum 50mm spacing between multiple inverters to avoid heat interference
  5. Keep away from heat sources, air outlets and direct sunlight
  6. Environmental Limits

Operating temperature: -10℃ ~ +55℃, derate load above 40℃

No condensation, dust, corrosive or flammable gas

Keep distance from high-power electromagnetic devices, contactors and motors

Derate operation when altitude exceeds 1000m

  1. Wiring Specifications

Main Circuit Wiring

  1. Do not reverse incoming L1/L2/L3 and outgoing U/V/W terminals
  2. Separate power cables and control cables with ≥20cm gap, no same conduit laying
  3. Reliable earthing, grounding resistance ≤4Ω, ground wire diameter no less than half of phase wire
  4. Fasten terminals with proper torque to prevent loose connection and overheating

Control Circuit Wiring

  1. Use shielded twisted pair for analog and communication cables, single-end shielding grounding
  2. Avoid routing signal cables close to power lines
  3. Prevent polarity reversal of external 24V power supply
  4. Heat Dissipation & Ventilation
  5. Keep cabinet door ventilated, clean filter screen regularly
  6. Equip cooling fan for smooth air circulation
  7. Avoid direct sunlight on the device
  8. EMC & Anti-interference Protection
  9. Built-in EMC filter works only with complete grounding
  10. Motor cable length recommended ≤50m; install output reactor for long cables
  11. Do not coil or twist input and output wires
  12. Freewheel diodes parallel connected to peripheral relays and solenoid valves
  13. Brake Accessory Installation

Built-in brake transistor matched with external brake resistor

  1. Use 75Ω/500W resistor, mount in well-ventilated area
  2. Short resistor wiring, firm connection and thermal isolation protection
  3. Pre-power Inspection
  4. Confirm 3-phase 380-480V input without phase loss
  5. Check no inter-phase or earth short circuit, correct and tight wiring
  6. Pass motor insulation test; perform no-load trial run first
  7. Mechanical Fixation
  8. Tighten four mounting screws evenly to avoid shake
  9. Flat mounting surface to prevent housing deformation
  10. Safety Regulations
  11. Wait 5 minutes after power off for DC bus discharge before disassembly
  12. Do not open cover or touch terminals during operation
  13. Forbid short-circuit protection terminals or disable fault protection functions

Prev:

Leave a Reply

Leave a message