M-SYSTEM W2YV-AAA-M Dual-Output Isolated Signal Conditioner - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

M-SYSTEM W2YV-AAA-M Dual-Output Isolated Signal Conditioner - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

electrical/

M-SYSTEM W2YV-AAA-M Dual-Output Isolated Signal Conditioner

Mini-MW W2YV Compact Dual-Output Isolator M-SYSTEM (Japan), DIN rail mount, 4-way galvanic isolation (Input / Output1 / Output2 / Power supply). Designed for 4~20mA industrial signal isolation, ground loop interference suppression and 1-input 2-output signal distribution. ✅ Model Decoding W2YV-AAA-M W2YV ①②③ ④ ① A: Input signal = DC 4~20mA (Input resistance: 250Ω) ② A: ...

  • Product Details

Mini-MW W2YV Compact Dual-Output Isolator

M-SYSTEM (Japan), DIN rail mount, 4-way galvanic isolation (Input / Output1 / Output2 / Power supply). Designed for 4~20mA industrial signal isolation, ground loop interference suppression and 1-input 2-output signal distribution.

✅ Model Decoding W2YV-AAA-M

W2YV ①②③ ④

  1. ① A: Input signal = DC 4~20mA (Input resistance: 250Ω)
  2. ② A: Output 1 = DC 4~20mA (Max load ≤750Ω)
  3. ③ A: Output 2 = DC 4~20mA (Max load ≤350Ω)
  4. ④ M: Power supply = AC 85~264V wide-range AC (47~66Hz)

Full definition: 4~20mA input, two independent isolated 4~20mA outputs, AC85-264V powered signal distribution isolator

📋 Core Technical Specifications

ItemSpecifications
Isolation StructureGalvanic isolation between Input / OUT1 / OUT2 / Power supply
Accuracy±0.1% FS
Temperature Drift±0.015% /℃
Response Time≤0.5s (0~90%)
Withstand Voltage2000V AC, 1 minute (between each isolation barrier)
Insulation Resistance≥100MΩ @500VDC
Zero / Span AdjustmentFront panel independent trimming; separate ZERO/SPAN adjustment for two outputs
MountingDIN rail, dense side-by-side installation for high-density cabinet layout
Overall DimensionsW29.5 × H88.5 × D124 mm
TerminalsM3 screw, tightening torque 0.8 N·m
Operating Environment-5 ~ +55℃, 30~90%RH (non-condensing)
Power ConsumptionApprox. 4VA @AC100V; Approx. 6VA @AC240V
WeightApprox. 200g

🎯 Typical Applications

  1. Eliminate ground loop interference between PLC and transmitters
  2. Distribute one 4~20mA measurement signal to PLC + recorder / indicator (1-input 2-output signal splitting)
  3. Provide galvanic isolation between field transmitters and control room systems to protect AI modules
  4. Impedance conversion for parallel acquisition by multiple receiving instruments

⚙️ Selection & Replacement Information

Same series DC powered variant: W2YV-AAA-R2 (DC11~27V supply)

Domestic alternatives: Yutong, Chenzhu, Wanxun and other 1-in-2-out 4-20mA isolators (compare isolation rating, accuracy and temperature drift)

Note: The two current outputs have different maximum load limits. OUT2 max load is only 350Ω. Use OUT1 for high-load applications.

📌 Troubleshooting Guide

  1. Inaccurate output: Recalibrate ZERO/SPAN on front panel; check 250Ω matching resistor on input loop
  2. No output signal: Verify AC supply 85~264V; check tightness of M3 terminal screws
  3. Signal drift: Check earthing; ensure input side ground is separated from PLC ground. The isolator is used to break common ground.
  4. Excessive voltage drop under load: Connect the load to OUT1 channel (OUT1 has higher load capacity)

W2YV (Mini-MW Dual-Output Signal Conditioner) Complete Model Code + Common Model List

W2YV = W2YV-①②③-④⑤

①: Input signal; ②: OUT1 output; ③: OUT2 output; ④: Power supply; ⑤: Optional suffix

Code Definition

① Input Code

A: DC 4~20mA, input resistance 250Ω

6: DC 1~5V, input impedance ≥1MΩ

② OUT1 (Channel 1, higher load capacity: Max 750Ω)

A: DC 4~20mA

6: DC 1~5V

③ OUT2 (Channel 2; Max 350Ω for current output; ≥5kΩ for voltage output)

A: DC 4~20mA

6: DC 1~5V

Y: No output (single-output mode)

④ Power Code

M: AC85~264V (Wide AC)

R2: DC11~27V (24V DC supply)

⑤ Options (Suffix /Q, multiple options can be combined)

C01: Silicone coating (moisture & dust protection)

C02: Polyurethane coating

C03: Rubber coating

V01: Multi-turn trim potentiometer

S01: Stainless steel terminal screws

✅ Common Available Models of W2YV Series

  1. W2YV-AAA-M: 4~20mA input, dual 4~20mA outputs, AC85~264V (your target model)
  2. W2YV-AAA-R2: 4~20mA input, dual 4~20mA outputs, DC11~27V
  3. W2YV-6AA-M: 1~5V input, dual 4~20mA outputs, AC supply
  4. W2YV-6AA-R2: 1~5V input, dual 4~20mA outputs, DC supply
  5. W2YV-A6A-M: 4~20mA input, OUT1=1~5V, OUT2=4~20mA, AC supply
  6. W2YV-AA6-M: 4~20mA input, OUT1=4~20mA, OUT2=1~5V, AC supply
  7. W2YV-6A6-M: 1~5V input, OUT1=4~20mA, OUT2=1~5V, AC supply
  8. W2YV-A66-R2: 4~20mA input, dual 1~5V voltage outputs, DC supply
  9. W2YV-AAY-M: 4~20mA input, OUT1=4~20mA only, OUT2 no output (single output)
  10. W2YV-666-R2: 1~5V input, dual 1~5V voltage outputs, DC supply

📌 Other W2 Family Models (Same DIN rail housing as W2 series)

W2XF: Arithmetic signal conditioner (addition / subtraction calculation)

W2VABS: Absolute value signal converter

W2RS: RTD resistance temperature detector isolator

W2YV is only for DC mA/V signal 1-in-2-out isolation and distribution. For temperature measurement or arithmetic functions, select other W2 series models above.

⚠️ Important Selection Notes

  1. Mixed output (one current + one voltage): Place current signal on OUT1. OUT1 has higher load capacity (750Ω vs 350Ω of OUT2)
  2. Coated versions C01 are recommended for high-humidity and chemical cabinet environments
  3. Side-by-side dense DIN installation; no heat dissipation gap required, which is the key advantage of this series

W2YV‑AAA‑M (M-SYSTEM) Overall Dimensions

Width(W) × Height(H) × Depth(D) = 29.5 mm × 88.5 mm × 124 mm

Inch: 1.16″ × 3.48″ × 4.88″

Supplementary Dimension Information

  1. DIN rail mounting: 35mm standard DIN rail. Modules can be closely mounted side by side, no heat dissipation gap required between modules, ideal for high-density cabinet arrangement
  2. Weight: Approx. 200g
  3. Mounting method: DIN rail clip mounting, or base plate screw fixing (2×Φ4.2 mounting holes)
  4. Terminals: M3 screw terminals. The terminal block protrudes forward; above dimensions refer to maximum overall outline of the unit.

W2YV‑AAA‑M Input Signal Description

For model W2YV-AAA-M specifically: Input is fixed as DC 4~20mA (1st character A), input resistance 250Ω

All Optional Input Types of W2YV Series (1st character in model code)

  1. A: DC 4~20mA (Current Input)

Input resistance: 250Ω

This is the input specification of your W2YV-AAA-M

  1. 6: DC 1~5V (Voltage Input)

Input impedance ≥1MΩ, high-impedance voltage acquisition

⚠️ Important: W2YV series only has these two factory fixed input ranges. It is NOT programmable. It cannot be modified on-site for 0-10V, 0-20mA, thermocouple or RTD signals. If temperature measurement or multi-range programmable function is required, select other W2 series models such as W2XF.

Brief Comparison

CodeSignal TypeInput Impedance
ADC 4~20mA250Ω
6DC 1~5V≥1MΩ

Supplement

The input range of W2YV is locked at factory by model coding. It cannot be changed by hardware jumpers on site. Only A (4~20mA) or 6 (1~5V) can be selected during ordering.

Prev:

Leave a Reply

Leave a message