Order No.: 777301
Product Name: PNOZ X2.8P
Supply Voltage: 24 V AC/DC
Mounting: DIN rail mounting
Housing Width: 22.5 mm
Terminals: Plug-in screw terminals
Certifications: TÜV, CE, cULus, CCC
Safety Specifications
Safety Outputs: 3 NO positive-guided safety contacts + 1 NC auxiliary contact
Safety Level: PL d / Cat.3 / SIL2 (EN ISO 13849-1)
Input: Dual-channel safety input, with short-circuit detection
Start Mode: Automatic start / Monitored manual start (selectable via wiring)
Typical Applications: Emergency stop, safety gate, safety interlock monitoring
Contact Ratings
AC1 240 V: 6 A, 1500 VA
DC1 24 V: 6 A, 150 W
AC15 230 V: 5 A
DC13 24 V: 4 A
Comparison with 777303 (PNOZ X2P)
| Model | Order No. | Short-Circuit Detection | Terminal Type |
| PNOZ X2.8P | 777301 | ✅ Dual-channel short-circuit detection | Plug-in screw terminals |
| PNOZ X2P | 777303 | ✅ Dual-channel short-circuit detection | Plug-in screw terminals |
Replacement Models
Direct upgrade replacement: PNOZ S2 (750102) (PNOZsigma series), identical functions, compact size, enhanced diagnostic functions
Spring-cage terminal version: No native spring-cage variant for X series; select PNOZsigma series directly.
Supplementary Notes
The PNOZ X series is a legacy product and gradually phased out. The P-version supports wire short-circuit diagnosis; if two signal wires short out, the relay will detect the fault and refuse to activate, greatly improving safety.
Complete Model List of PILZ PNOZ X Series (Obsolete Legacy Range)
Prefix Coding Rule (Terminal Differentiation)
774xxx: Fixed screw terminals (basic non-P models, no short-circuit detection)
777xxx: Plug-in screw terminals (enhanced P-models, with short-circuit detection)
787xxx: Spring-cage terminals (C-type, corresponding to 777xxx models)
Non-P suffix: No dual-channel short-circuit detection; P suffix: Dual-channel short-circuit detection available
- Basic Non-P Range (774xxxx, Fixed Screw Terminals)
1) PNOZ X1 (Single-channel, 3NO+1NC)
774300 PNOZ X1 24 V AC/DC
2) PNOZ X2 (Dual-channel, 2NO, no short-circuit detection)
774301 PNOZ X2 24 V AC/DC
3) PNOZ X3 (Dual-channel, 3NO+1NC + 1 semiconductor output)
774310 24 V AC/DC
774311 42 V AC
774312 48 V AC
774314 110–120 V AC
774315 230–240 V AC
4) PNOZ X4 (3NO+1NC)
774736 110–120 V AC
5) PNOZ X6 (3NO)
774721 42 V AC
774725 110–120 V AC
774726 230–240 V AC
6) PNOZ X7 (Single-channel, 2NO)
774049 48 V AC
7) PNOZ X10 (High-capacity 6NO+4NC)
774700 24 V AC (for vibration-intensive equipment)
- Quick Selection Table by Application (High-Frequency Models)
| Application | Recommended Model | Order No. | Key Features |
| Dual-channel E-STOP, short-circuit detection, automatic reset | PNOZ X2.8P | 777301 | Auto start, 3NO+1NC, plug-in terminals |
| Dual-channel E-STOP, short-circuit detection, mandatory manual reset | PNOZ X2.7P | 777305 | Monitored start only, prevents unexpected restart |
| General E-STOP / safety gate, auto/manual start selectable | PNOZ X2P | 777303 | 2NO, wiring-selectable mode, best-selling spare part |
| PNP safety light curtain (OSSD, curtain with built-in short-circuit diagnosis) | PNOZ X2 | 774301 | No relay short-circuit detection, avoids signal conflict with light curtain |
| Safety gate with PLC feedback signal | PNOZ X3P | 777310 | 3NO+1NC + 1 PNP semiconductor output |
| Multiple contactors to be cut off simultaneously, multi-power circuits | PNOZ X10 | 774700 | 6NO+4NC high-capacity contacts |
| Low-risk single-channel protection | PNOZ X7 / X7P | 774049 / 777059 | Single-channel 2NO contacts |
- Critical Selection Restrictions & Common Pitfalls
- Do NOT enable short-circuit detection when using PNP OSSD safety light curtains
Light curtains already have built-in pulse diagnosis. Enabling short-circuit detection on X2P/X2.8P will cause pulse conflict and continuous fault alarms. Turn off the relay’s short-circuit monitoring in this case.
- Auxiliary NC contact (41-42) cannot be used in safety circuits
Only for PLC fault alarm and indicator feedback.
- Contact load limits
AC15 230 V max. 5 A; DC13 24 V max. 4 A. If contactor coil current exceeds the rating, use PZE contact expansion modules. Do not drive heavy loads directly via safety contacts.
- No time-delayed safety outputs in X series
For delayed stop applications, select PNOZ XV series instead.
- Two-hand control function
Prefer X3P or PNOZ S6; basic X models do not support two-hand logic.
- Obsolete Model Replacement Table (Spare Part Replacement & New Projects)
| Obsolete PNOZ X Model | Recommended PNOZsigma Replacement | Remarks |
| PNOZ X2 (774301) | PNOZ S2 (750102) | Dual-channel, PL d, 2NO contacts |
| PNOZ X2P (777303) | PNOZ S2 (750102) | Fully equivalent function; S series includes native short-circuit detection |
| PNOZ X2.8P (777301) | PNOZ S3 (750103) | Automatic start, 3NO+1NC |
| PNOZ X2.7P | PNOZ S3 (750103) | Change wiring to enable monitored manual reset |
| PNOZ X3P | PNOZ S4 (750104) | With semiconductor feedback output |
| PNOZ X10 | PNOZ S10 (751104) | High-capacity multi-contact version |
- Pre-Order Selection Checklist
Confirm PL / Cat / SIL requirement: X series max. PL d / Cat.3 / SIL2; not applicable for PL e / Cat.4 / SIL3 applications
Input device type: E-STOP / safety gate → select P-model with short-circuit detection; PNP light curtain → disable short-circuit detection
Reset logic: Automatic start / Monitored manual start
Number of safety NO contacts required; whether semiconductor feedback to PLC is needed
Supply voltage; terminal preference (screw / spring-cage)
Load current; confirm whether PZE contact expansion modules are required
- Selection Mnemonic
E-stop & safety gate choose P-version;
Turn off short-circuit detection for light curtains;
Auto reset → X2.8P, mandatory reset → X2.7P;
X2P works for both modes; X3P provides PLC feedback;
X series only for spare parts; new projects use S-series directly.
Contactor,circuit breaker,sensor,Encoder,PLC,Converter



















NH42-63-318x560.png)