Schneider EOCRPFZ-H1DZ7W Intelligent Motor Protector - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

 Schneider EOCRPFZ-H1DZ7W Intelligent Motor Protector - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

electrical/

 Schneider EOCRPFZ-H1DZ7W Intelligent Motor Protector

Schneider EOCRPFZ-H1DZ7W is a high-performance flush-mounted intelligent motor protector integrating multiple protection functions. It features wide current range and universal voltage supply, compatible with various industrial motors. Equipped with millisecond-level response, fault recording function and 4-20mA analog output, it serves as an ideal solution for motor protection in industrial automation systems. Proper parameter configuration effectively ...

  • Product Details

Schneider EOCRPFZ-H1DZ7W is a high-performance flush-mounted intelligent motor protector integrating multiple protection functions. It features wide current range and universal voltage supply, compatible with various industrial motors. Equipped with millisecond-level response, fault recording function and 4-20mA analog output, it serves as an ideal solution for motor protection in industrial automation systems. Proper parameter configuration effectively extends motor service life, reduces equipment failure rate and boosts production efficiency.

  1. Model Code Definition
SegmentCodeDescription
Product SeriesEOCRPFZElectronic Over Current Relay, Panel Flush Mount Type
Mounting TypeHCombined type, matched with 3 current transformers
Current Rating1Direct measurement: 0.5~60A
5-turn mode: 0.1~2.0A
External CT: 1~3600A
Function ConfigurationDBasic protection + 1-channel 4-20mA analog output
Voltage RatingZ7Wide voltage supply: 85~250VAC/DC, 50/60Hz
Additional FunctionWStandard version with fault record, LED display and reset function
  1. Core Technical Parameters
CategorySpecificationRemark
Protection FunctionsOvercurrent, undercurrent, phase loss, locked rotor, reverse rotation, current unbalance, stall, grounding, leakage, short circuit, pre-alarmSelectable definite time, inverse time and overheating inverse time characteristics
Current RangeDirect: 0.5~60AWide coverage for diverse motors
5-turn: 0.1~2.0A
External CT: 1~3600A
Power Supply85~250VAC/DC, 50/60HzStrong tolerance to voltage fluctuation
Output Signal1-channel 4-20mA current loopFor PLC and upper computer monitoring
Contact Rating1-SPST, AC250V/3A resistive loadStandard control contact
Display ModeLCD screen, automatic 5-second cyclic display of three-phase current and leakage currentManual display switching available
Fault RecordRecords latest 3 fault causes and current values, data retained after power offConvenient fault analysis
Response Time20msFast motor protection
Installation35mm DIN rail or panel flush mountingCutout: 44-55-66mm, Outline: 55-66-77mm
Working AmbientTemperature: -35~85℃, Humidity: ≤95% non-condensingSuitable for harsh industrial conditions
Insulation PerformanceInsulation resistance: ≥10MΩ@DC500VSafe and reliable
Withstand voltage: 2kV/50Hz for 1min between circuit and shell
Order NumberEOCRPFZ-H1DZ7WOfficial Schneider part number
  1. Full Model List (EOCR-PFZ Series)
ModelCurrent RatingFunctionPower SupplyExtra Feature
EOCRPFZ-H1DZ7W0.5~60ABasic + 1×4-20mA85~250VAC/DCStandard
EOCRPFZ-H2DZ7W0.5~60ABasic + 2×4-20mA85~250VAC/DCStandard
EOCRPFZ-WRDZ7W0.5~60ABasic + 1×4-20mA85~250VAC/DCStandard
EOCRPFZ-WRDUH0.5~60ABasic + Communication85~250VAC/DCStandard
EOCRPFZ-C-WRDBWQ0.5~60ABasic + 1×4-20mA24VAC/DCWide range
EOCRPFZ-C-WRDBT0.5~60ABasic + 1×4-20mA24VAC/DCWide range
EOCRPFZ-H3DBW0.5~60ABasic + 3-channel output85~250VAC/DCStandard
EOCRPFZ-WRDZ7WQ0.5~60ABasic + 1×4-20mA85~250VAC/DCEnhanced
  1. Cross-brand Replacement Comparison
Schneider EOCRPFZ-H1DZ7WABBSiemensOmronFeature Comparison
Intelligent motor protectorM101-P3RW55K8DSSchneider: 3 fault records, 20ms fast response
0.5~60A0.1~63A0.1~63A0.1~63AABB: Superior communication performance
1×4-20mA1×4-20mA1×4-20mA1×4-20mASiemens: High PLC compatibility
Wide voltage24~240VAC/DC24~240VAC/DC24~240VAC/DCOmron: Cost-effective
  1. Common Faults & Troubleshooting
Fault PhenomenonCodeRoot CauseSolution
Protector fails to startPower cut-off, abnormal voltage1. Check wiring
2. Measure supply voltage
3. Verify DC polarity
False trippingOC/E1 OvercurrentImproper CT selection, wrong mounting, load fluctuation1. Match CT ratio with motor
2. Keep CT away from inverter
3. Adjust protection delay
Phase loss tripPH/E2Missing phase, loose wiring, CT failure1. Check three-phase voltage
2. Fasten terminals
3. Test CT output
Leakage tripLE/E3Poor line insulation, motor winding grounding1. Test motor insulation resistance
2. Inspect cable condition
3. Reset leakage threshold
Communication failureWrong wiring, mismatched baud rate1. Check RS485 A/B connection
2. Set 9600bps, 8N1
3. Confirm 120惟 terminal resistor
  1. Air Transport Compliance & Certifications

6.1 Certifications

CE: Compliant with EU LVD and EMC directives

UL: Meets US safety standards

CSA: Conforms to Canadian safety specifications

RoHS: Lead-free eco-friendly design

6.2 Air Shipment Rules

Battery status: No built-in lithium battery or supercapacitor, classified as non-dangerous goods

Packaging: Standard industrial package against vibration damage

Documents: CE certificate, manual and packing list required

Notice: Avoid contact with sharp objects to prevent shell and insulation damage

  1. Application Cases

Case 1: Fan Motor Protection in Steel Plant

Application: 380V 55kW frequent-start fan motor with locked rotor risk

Matching: EOCRPFZ-H1DZ7W + 200:5 three-phase CT

Setting: 1.2 times rated current overcurrent protection (inverse time); 3 times rated current locked rotor protection (0.5s delay); 3s delay phase loss protection

Outcome: 3 bearing seizure motor burnout accidents avoided, maintenance cost cut by 40%

Case 2: Chemical Pump Monitoring System

Application: 45kW explosion-proof chemical pump with remote current monitoring demand

Matching: EOCRPFZ-H1DZ7W + Modbus RTU module

Setting: 4-20mA output corresponding to 0~200A for PLC acquisition; enabled fault record; 300mA leakage protection threshold

Outcome: Real-time pump monitoring, early abnormal warning, production safety improved by 50%

  1. Selection Guidelines

Quick Rules

  1. Mounting: H=CT combined type, WR=direct measuring type
  2. Current: 1=0.5~60A, 2=0.5~100A
  3. Function: D=1-channel 4-20mA, H=2-channel, U=communication
  4. Voltage: Z7=85~250VAC/DC, C=24VAC/DC
  5. Version: W=Standard, Q=Enhanced

Applicable Scenarios of EOCRPFZ-H1DZ7W

General Applications

  1. Overload, phase loss, locked rotor and leakage protection for 380V three-phase industrial asynchronous motors
  2. Control circuits requiring 4-20mA remote signal transmission to PLC and host computer
  3. Panel flush mounting and DIN rail installation inside control cabinets
  4. Sites with severe voltage fluctuation, 85~250V AC/DC power supply

Industry Applications

Water Treatment: Water pump, sewage pump, dosing pump, aeration fan

HVAC: Centrifugal fan, axial fan, exhaust fan, cooling tower fan

Machinery Manufacturing: Conveyor, mixer, crusher, air compressor

Petrochemical: Process pump, stirring equipment, explosion-proof matched motor

Building & Metallurgy: Kiln fan, dust removal unit, conveying equipment

Building Power Distribution: Fire fan, water supply & drainage pump, central air conditioning motor

Power Adaptation Range

Direct measurement: 0.5~60A, fits 0.25~30kW motors

Extended by external CT: Max 3600A, applicable to high-power motors

Non-recommended Scenarios

  1. Motors driven by high-frequency inverter without power frequency operation
  2. Precision servo and stepper motor dedicated protection circuits
  3. Extreme environment below -35℃ or above 85℃
  4. Sealed space with heavy corrosion and dense dust without protective measures

Prev:

Leave a Reply

Leave a message