ABB 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit
ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750kW).
Its core strengths include high-reliability design (MTBF>100,000 hours), low harmonic output (compliant with IEEE 519 padrão), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40 ℃). It is perfectly suited for general industrial loads such as fans, bombas de água e compressores, which can effectively improve system energy efficiency (20%-40% economia de energia) and reduce maintenance costs.
- Explicação do código do modelo
| Seção | Código | Definição |
| Série de produtos | 2UEA | Series code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 série, 2UEB=ACS 2000 série) |
| Número da peça | 1345 | Unique identification code of phase module kit, correspondente ao modelo ACS 2040-PMK1000 |
| Applicable Voltage | 4kV | Matches 4000V medium-voltage power grid system |
| Tipo de produto | PMK1000 | Phase Module Kit, corrente nominal: 1000UM |
| Sistema Aplicável | ACS 2040 | Compatible with ABB ACS 2040 series medium-voltage inverters |
Número do pedido: 2UEA001345 (Standard single packing)
Matching Model: 2UEA001141 (Complementary phase module of the same series)
- Main Technical Specifications
| Categoria | Item | Parâmetro | Observações |
| Informações Básicas | Tipo de produto | 4kV Medium Voltage Inverter Phase Module Kit | 3-level IGBT topology, integrated drive and protection circuits |
| Applicable Inverter | ACS 2040 Série (ACS2000 Platform) | Compatible with Frame 1 tamanho (300-1000HP) | |
| Tensão nominal | 4kV (4000V) | Faixa de tensão operacional: 3.6~4.4kV | |
| Corrente nominal | 1000UM | Max peak current: 2000UM (2 times rated value) | |
| Power Devices | IGBT Type | High-voltage IGBT Module | 1700V/1200A, ABB customized version |
| Topologia | 3-level NPC (Neutral Point Clamped) | Reduce dv/dt and motor insulation stress | |
| Cooling Mode | Resfriamento de Ar Forçado | Built-in cooling fan, redundant design supported | |
| Parâmetros Elétricos | Frequência de entrada | 50/60Hz, ±5% | Compatible with global power grid standards |
| Frequência de comutação | 2~8kHz (Ajustável) | Balance energy efficiency and noise performance | |
| Power Loss | Aprox.. 1.2kW per module | Under typical working conditions | |
| Classe de isolamento | Overvoltage Category IV (CEI 60664) | Meet insulation requirements of medium-voltage systems | |
| Parâmetros Mecânicos | Dimensão (C×L×A) | 650×450×320mm | Standard Frame 1 tamanho |
| Peso líquido | 48.5kg | Excluding packaging | |
| Classe de Proteção | IP20 | Adequado para instalação em gabinete | |
| Funções de proteção | Proteção contra sobrecorrente | 2000UM (2 times rated) | Short-circuit response time <10μs |
| Proteção contra sobretensão | 4.4kV | DC bus overvoltage protection | |
| Over-temperature Protection | 100℃ | IGBT module overtemperature protection | |
| Proteção contra subtensão | 3.6kV | Grid undervoltage protection | |
| Certificações & Conformidade | CE Certificate | Sim | Compatível com EN 61800-5-1 |
| UL Certificate | Sim | Meet North American medium-voltage equipment standards | |
| IEEE 519 Conformidade | Sim | Total harmonic distortion <5% |
- Full Model List of ACS 2040 Series Phase Modules
| Modelo | Número do pedido. | Tensão nominal | Corrente nominal | Applicable Inverter | Notas |
| ACS 2040-PMK1000 | 2UEA001345 | 4kV | 1000UM | ACS 2040 Quadro 1 | Standard phase module |
| ACS 2040-PMK1000 | 2UEA001141 | 4kV | 1000UM | ACS 2040 Quadro 1 | Complementary phase module |
| ACS 2040-PMK1200 | 2UEA001346 | 4kV | 1200UM | ACS 2040 Quadro 1 | High current version |
| ACS 2040-PMK800 | 2UEA001347 | 4kV | 800UM | ACS 2040 Quadro 1 | Low current version |
| ACS 2040-PMK1000-6kV | 2UEA001348 | 6kV | 1000UM | ACS 2040 Quadro 2 | 6kV dedicated version |
- Substituição & Modelos Equivalentes
4.1 Internal ABB Replacement
| Modelo Antigo | Novo modelo | Replacement Description |
| ACS 1040-PMK1000 | ACS 2040-PMK1000 (2UEA001345) | Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30% |
| ACS 2040-PMK800 (2UEA001347) | ACS 2040-PMK1000 (2UEA001345) | Higher current model in the same series, wider power coverage |
4.2 Cross-brand Equivalent Products
| Marca | Modelo Equivalente | Vantagens |
| Siemens | SINAMICS GM150 Power Module | Superior 3-level topology, lower dv/dt, better motor insulation protection |
| Schneider Elétrica | Altivar 6100 Medium Voltage Module | Easier maintenance with modular design, higher MTBF (>100,000 hours) |
| Mitsubishi Elétrica | MV-VFD Power Module | Wider applicable voltage range (3.6-4.4kV), stronger environmental adaptability |
- Cenários de aplicação & Industry Cases
5.1 Aplicativos recomendados
| Tipo de aplicativo | Typical Working Conditions | Principais vantagens |
| Industrial Fans | Power plant induced draft fans, cement plant kiln fans, steel plant dust removal fans | Wide speed regulation range (0.1-100Hz), 30%-40% economia de energia |
| Industrial Water Pumps | Water plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumps | Soft start without impact, reduce pipeline stress and extend service life |
| Compressores | Air compressors, natural gas compressors, refrigeration compressors | Precise pressure control, reduce no-load loss and improve energy efficiency |
| Transportadores | Long-distance mine conveyors, port container conveyors | Smooth speed regulation, avoid material accumulation and mechanical wear |
| General Industrial Equipment | Misturadores, trituradores, extrusoras, etc.. | Modular design for convenient maintenance, MTBF>100,000 hours |
5.2 Not Recommended Usage Scenarios
Áreas à prova de explosão (non-explosion-proof structure, customized version required)
Plataformas offshore (additional anti-corrosion treatment needed)
Ultra-high voltage systems above 4.4kV (select 6kV version instead)
Equipment with frequent start-stop operations (more than 10 vezes por hora, special customized modules recommended)
5.3 Practical Cases
Caso 1: Induced Draft Fan Renovation in Thermal Power Plant
Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear
Renovation solution: ACS 2040 inverter + 3 sets of 2UEA001345 phase modules (3-fase)
Effect: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 million RMB, baffle maintenance cycle extended 5 vezes
Caso 2: High-pressure Water Supply System for Large Water Plant
Demanda: Constant pressure water supply with large load fluctuation (20%-100%)
Solução: ACS 2040 Quadro 1 (3 pcs 2UEA001345 modules) + PID control system
Effect: Stable pressure deviation within ±0.05MPa, 32% economia de energia, service life extended by 3 anos
- Air Shipment Compliance & Certification Guide
6.1 Shipment Compliance Confirmation
| Item | Status | Explicação |
| Built-in Lithium Battery | Não | Only electronic components and IGBT modules equipped |
| Dangerous Goods Classification | Non-dangerous goods | Compliant with IATA DGR Class 9, no special shipping restrictions |
| Transport Restrictions | Nenhum | Can be shipped as ordinary industrial equipment |
| Packaging Standard | Standard shockproof package | Fix IGBT modules firmly to avoid damage during transit |
| Faixa de temperatura | -20℃ ~ +50℃ | Avoid extreme temperature during transportation |
6.2 Certification Document Acquisition
CE Certificate: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)
UL Certificate: Apply via ABB global technical support center
Manufacturer Declaration: Including EMC, safety and RoHS compliance statements
- Diretrizes de seleção & Quick Rules
Selection Rules
- Correspondência de tensão: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
- Seleção Atual: 1000A standard (PMK1000), 800A low current (PMK800), 1200Uma alta corrente (PMK1200)
- Compatibilidade do sistema: Only applicable to ACS 2040 série (ACS2000 platform) Quadro 1 tamanho
- Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
- Dicas de manutenção: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
- Main Accessories & Configuração recomendada
| Nome do acessório | Modelo | Função |
| Unidade de Controle | ACS 2040-CU | Core control unit matched with phase modules |
| Ventilador de resfriamento | 3HAC031683-001 | Special cooling fan for phase modules, support redundant operation |
| Drive Board | 3HAC031684-001 | IGBT drive circuit with integrated protection functions |
| Voltage Sensor | 3HAC031685-001 | 4kV system voltage monitoring, realize over/under voltage protection |
| Current Sensor | 3HAC031686-001 | 1000A current detection, sobrecorrente & proteção contra curto-circuito |
| Installation Kit | 3HAC031687-001 | Including fixing bolts, gaskets, insulating sleeves etc. |
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares