Kit de módulo de fase ABB 2UEA001345

ABB 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit

ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750kW).

Its core strengths include high-reliability design (MTBF>100,000 hours), saída harmônica baixa (compatível com IEEE 519 padrão), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40 ℃). It is perfectly suited for general industrial loads such as fans, bombas de água e compressores, which can effectively improve system energy efficiency (20%-40% economia de energia) and reduce maintenance costs.

  1. Explicação do código do modelo
SeçãoCódigoDefinição
Série de produtos2UEASeries code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 série, 2UEB=ACS 2000 série)
Número da peça1345Unique identification code of phase module kit, correspondente ao modelo ACS 2040-PMK1000
Tensão Aplicável4kVMatches 4000V medium-voltage power grid system
Tipo de produtoPMK1000Phase Module Kit, corrente nominal: 1000UM
Sistema AplicávelACS 2040Compatible with ABB ACS 2040 series medium-voltage inverters

Número do pedido: 2UEA001345 (Standard single packing)

Modelo correspondente: 2UEA001141 (Complementary phase module of the same series)

  1. Principais Especificações Técnicas
CategoriaItemParâmetroObservações
Informações BásicasTipo de produto4kV Medium Voltage Inverter Phase Module Kit3-level IGBT topology, integrated drive and protection circuits
Applicable InverterACS 2040 Série (ACS2000 Platform)Compatible with Frame 1 tamanho (300-1000HP)
Tensão nominal4kV (4000V)Faixa de tensão operacional: 3.6~4.4kV
Corrente nominal1000UMMax peak current: 2000UM (2 times rated value)
Power DevicesIGBT TypeHigh-voltage IGBT Module1700V/1200A, ABB customized version
Topologia3-level NPC (Neutral Point Clamped)Reduce dv/dt and motor insulation stress
Cooling ModeResfriamento de Ar ForçadoBuilt-in cooling fan, redundant design supported
Parâmetros ElétricosFrequência de entrada50/60Hz, ±5%Compatible with global power grid standards
Frequência de comutação2~8kHz (Ajustável)Balance energy efficiency and noise performance
Power LossAprox.. 1.2kW per moduleUnder typical working conditions
Classe de isolamentoOvervoltage Category IV (CEI 60664)Meet insulation requirements of medium-voltage systems
Parâmetros MecânicosDimensão (C×L×A)650×450×320mmStandard Frame 1 tamanho
Peso líquido48.5kgExcluding packaging
Classe de ProteçãoIP20Adequado para instalação em gabinete
Funções de proteçãoProteção contra sobrecorrente2000UM (2 times rated)Short-circuit response time <10μs
Proteção contra sobretensão4.4kVDC bus overvoltage protection
Over-temperature Protection100℃IGBT module overtemperature protection
Proteção contra subtensão3.6kVGrid undervoltage protection
Certificações & ConformidadeCertificados CESimCompatível com EN 61800-5-1
Certificados ULSimMeet North American medium-voltage equipment standards
IEEE 519 ConformidadeSimTotal harmonic distortion <5%
  1. Full Model List of ACS 2040 Series Phase Modules
ModeloNúmero do pedido.Tensão nominalCorrente nominalApplicable InverterNotas
ACS 2040-PMK10002UEA0013454kV1000UMACS 2040 Quadro 1Standard phase module
ACS 2040-PMK10002UEA0011414kV1000UMACS 2040 Quadro 1Complementary phase module
ACS 2040-PMK12002UEA0013464kV1200UMACS 2040 Quadro 1High current version
ACS 2040-PMK8002UEA0013474kV800UMACS 2040 Quadro 1Versão de baixa corrente
ACS 2040-PMK1000-6kV2UEA0013486kV1000UMACS 2040 Quadro 26kV dedicated version
  1. Substituição & Modelos Equivalentes

4.1 Internal ABB Replacement

Modelo AntigoNovo modeloDescrição da substituição
ACS 1040-PMK1000ACS 2040-PMK1000 (2UEA001345)Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30%
ACS 2040-PMK800 (2UEA001347)ACS 2040-PMK1000 (2UEA001345)Higher current model in the same series, wider power coverage

4.2 Cross-brand Equivalent Products

MarcaModelo EquivalenteVantagens
SiemensSINAMICS GM150 Power ModuleSuperior 3-level topology, lower dv/dt, better motor insulation protection
Schneider ElétricaAltivar 6100 Medium Voltage ModuleEasier maintenance with modular design, higher MTBF (>100,000 hours)
Mitsubishi ElétricaMV-VFD Power ModuleWider applicable voltage range (3.6-4.4kV), stronger environmental adaptability
  1. Cenários de aplicação & Casos da Indústria

5.1 Aplicativos recomendados

Tipo de aplicativoTypical Working ConditionsPrincipais vantagens
Industrial FansPower plant induced draft fans, cement plant kiln fans, steel plant dust removal fansWide speed regulation range (0.1-100Hz), 30%-40% economia de energia
Industrial Water PumpsWater plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumpsSoft start without impact, reduce pipeline stress and extend service life
CompressoresCompressores de ar, natural gas compressors, refrigeration compressorsPrecise pressure control, reduce no-load loss and improve energy efficiency
TransportadoresLong-distance mine conveyors, port container conveyorsSmooth speed regulation, avoid material accumulation and mechanical wear
General Industrial EquipmentMisturadores, trituradores, extrusoras, etc..Modular design for convenient maintenance, MTBF>100,000 hours

5.2 Not Recommended Usage Scenarios

Áreas à prova de explosão (non-explosion-proof structure, customized version required)

Plataformas offshore (additional anti-corrosion treatment needed)

Ultra-high voltage systems above 4.4kV (select 6kV version instead)

Equipment with frequent start-stop operations (more than 10 vezes por hora, special customized modules recommended)

5.3 Practical Cases

Caso 1: Induced Draft Fan Renovation in Thermal Power Plant

Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear

Renovation solution: ACS 2040 inversor + 3 sets of 2UEA001345 phase modules (3-fase)

Efeito: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 milhões de RMB, baffle maintenance cycle extended 5 vezes

Caso 2: High-pressure Water Supply System for Large Water Plant

Demanda: Constant pressure water supply with large load fluctuation (20%-100%)

Solução: ACS 2040 Quadro 1 (3 pcs 2UEA001345 modules) + PID control system

Efeito: Stable pressure deviation within ±0.05MPa, 32% economia de energia, service life extended by 3 anos

  1. Conformidade de Remessa Aérea & Certification Guide

6.1 Shipment Compliance Confirmation

ItemStatusExplicação
Bateria de lítio embutidaNãoOnly electronic components and IGBT modules equipped
Classificação de Mercadorias PerigosasMercadorias não perigosasCompatível com classe IATA DGR 9, no special shipping restrictions
Transport RestrictionsNenhumCan be shipped as ordinary industrial equipment
Padrão de embalagemStandard shockproof packageFix IGBT modules firmly to avoid damage during transit
Faixa de temperatura-20℃ ~ +50 ℃Avoid extreme temperature during transportation

6.2 Certification Document Acquisition

Certificados CE: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)

Certificados UL: Apply via ABB global technical support center

Declaração do Fabricante: Including EMC, safety and RoHS compliance statements

  1. Diretrizes de seleção & Regras rápidas

Regras de seleção

  1. Correspondência de tensão: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
  2. Seleção Atual: 1000A standard (PMK1000), 800A low current (PMK800), 1200Uma alta corrente (PMK1200)
  3. Compatibilidade do sistema: Only applicable to ACS 2040 série (ACS2000 platform) Quadro 1 tamanho
  4. Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
  5. Dicas de manutenção: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
  6. Main Accessories & Configuração recomendada
Nome do acessórioModeloFunção
Unidade de ControleACS 2040-CUCore control unit matched with phase modules
Ventilador de resfriamento3HAC031683-001Special cooling fan for phase modules, support redundant operation
Drive Board3HAC031684-001IGBT drive circuit with integrated protection functions
Voltage Sensor3HAC031685-0014kV system voltage monitoring, realize over/under voltage protection
Current Sensor3HAC031686-0011000A current detection, sobrecorrente & proteção contra curto-circuito
Installation Kit3HAC031687-001Including fixing bolts, gaskets, insulating sleeves etc.