
Both models belong to the Schneider PowerLogic/Easergy P3U30 Series Universal Protection Relay. The core difference lies only in the last two characters (AA vs AC). The complete structure analysis is as follows:
| Segmento de modelo | Significado | P3U30-5AAA2BBAA | P3U30-5AAA2BBAC |
| P3U30 | Série de produtos | Universal Protection Relay (P3U30) | Universal Protection Relay (P3U30) |
| 5 | Tipo de fonte de alimentação | 48-230V CA/CC | 48-230V CA/CC |
| AAA | Measurement Input | 3TC (1/5UM), 1Io (1/5UM), 4TV (100V/110V) | 3TC (1/5UM), 1Io (1/5UM), 4TV (100V/110V) |
| 2 | Configuração de E/S | 16D/8C (with watchdog) | 16D/8C (with watchdog) |
| BB | Módulo de Comunicação | Basic communication configuration | Basic communication configuration |
| AA/AC | Digital Input Voltage + Interface de comunicação | AA: DI=220V AC/DC, RS485 serial port only | AC: DI=110-230V AC/DC, Dual RJ45 Ethernet ports + RS485 |
- Key Specification Comparison Table
| Categoria de parâmetro | P3U30-5AAA2BBAA | P3U30-5AAA2BBAC | Impact of Difference |
| Standard REL Code | REL52002 | REL52008 | Official material code distinction |
| Entrada Digital (DE) | 16 canais, 220V CA/CC | 16 canais, 110-230V CA/CC | AC version has wider voltage range for more application scenarios |
| Interface de comunicação | 1×RS485 Serial Port (Modbus RTU / CEI 60870-5-101/103) | 2×RJ45 Ethernet Ports (CEI 61850 / Modbus TCP) + 1×RS485 Serial Port | AC version supports Ethernet communication for system network integration |
| Protocolo de comunicação | Serial protocols only (no Ethernet) | All serial protocols + Ethernet protocols (CEI 61850 Ed.1/Ed.2, DNP3, Ethernet/IP) | AC version complies with modern industrial Ethernet standards |
| Tipo de conexão | Terminais de parafuso | Terminais de parafuso + Dual RJ45 ports | AC version facilitates network wiring and remote monitoring |
| Other Core Parameters | Idêntico: 3CT phase current input (1/5UM), 1Io residual current input (1/5UM), 4VT voltage input (100V/110V), 8FAZER (with watchdog), 48-230V AC/DC power supply | Idêntico | Basic protection functions are fully consistent |
- Detailed Description of Differences
3.1 Digital Input Voltage Difference
P3U30-5AAA2BBAA (REL52002): Fixed digital input of 220V AC/DC, suitable for standard industrial control voltage environments.
P3U30-5AAA2BBAC (REL52008): Wide-range digital input of 110-230V AC/DC, compatible with more international standard voltages with higher flexibility.
3.2 Communication Capability Difference (Core Distinction)
P3U30-5AAA2BBAA: Equipped with only RS485 serial communication, suitable for simple point-to-point communication; does not support network integration or remote monitoring.
P3U30-5AAA2BBAC: Equipped with dual RJ45 Ethernet ports + Porta serial RS485, apoiando:
Redundant Ethernet communication (RSTP/PRP protocol)
CEI 61850 substation communication standard (Ed.1/Ed.2)
Modern industrial protocols such as Modbus TCP, DNP3, Ethernet/IP
Remote configuration, monitoring and firmware upgrade
3.3 Application Scenario Adaptation
| Cenário de aplicação | Modelo recomendado | Razão |
| Traditional Substation (No network requirement) | P3U30-5AAA2BBAA | Menor custo, meets basic communication needs |
| Smart Substation / Industrial IoT | P3U30-5AAA2BBAC | Suporta IEC 61850 for easy system integration |
| International Projects / Multi-voltage Environment | P3U30-5AAA2BBAC | Wide-range DI voltage adapts to different national standards |
| Monitoramento Remoto & Diagnostics Requirement | P3U30-5AAA2BBAC | Ethernet enables remote access |
| Cost-Sensitive Projects | P3U30-5AAA2BBAA | Aproximadamente 10-15% lower price than AC version |
- Recomendações de seleção
- Communication Requirement Judgment
Local communication or simple SCADA connection only: Choose AA version (REL52002)
CEI 61850, remote monitoring or network redundancy required: Must choose AC version (REL52008)
- Digital Input Voltage Adaptation
System unified with 220V control voltage: AA version fully compatible
Mixed 110V/220V control voltage or uncertain future demands: Choose AC version with wide-range input
- Expansibilidade Futura
The dual Ethernet port design of AC version reserves space for future system upgrades and supports advanced smart grid applications.
- Informações Complementares
Hardware Compatibility: Both models have identical physical dimensions and mounting methods, enabling direct interchangeable installation.
Funções de proteção: Both provide more than 40 protection functions including overcurrent, falha de terra, subtensão, phase sequence reversal, etc., meeting feeder and motor protection requirements.
Certificações: Both comply with international standards such as IEC 60255 e PT 61850 for global market application.
Communication Interface Difference: P3U30-5AAA2BBAA vs P3U30-5AAA2BBAC
P3U30-5AAA2BBAA has only an RS485 serial port without Ethernet; P3U30-5AAA2BBAC retains RS485 and adds dual RJ45 Ethernet ports to support network communication.
- Detailed Communication Interface Comparison
| Item | P3U30-5AAA2BBAA | P3U30-5AAA2BBAC |
| Physical Network Port | No RJ45 Ethernet port | 2-channel RJ45 Ethernet ports |
| Serial Interface | 1-channel RS485 terminal | 1-channel RS485 terminal (retained same as AA version) |
| Communication Hardware | Serial communication hardware only | Dual hardware: Serial + Ethernet |
| Protocolos Suportados | Serial protocols only: | All serial protocols + Ethernet protocols: |
| Modbus RTU, CEI 60870-5-101/103 | Modbus TCP, CEI 61850, DNP3, etc.. | |
| Networking Capability | Only RS485 bus networking | Supports Ethernet star/ring/redundant networking and dual-port cascading |
| Remoto / Smart Substation | No Ethernet remote access, no IEC61850 support | Supports remote network access and IEC61850 smart substation standard |
- Key Difference Summary
- AA Version: Pure serial port type
Only RS485 interface, limited to traditional RS485 bus networking; cannot connect to switches, access Ethernet, or support IEC61850.
- AC Version: Hybrid type with serial port + dual Ethernet ports
Retains the original RS485 interface and adds 2 RJ45 ports, which can be directly connected to industrial switches, form ring networks, and support IEC61850 & Modbus TCP network communication.
- Simple Selection Rule
Only RS485 communication for traditional cabinet internal connection → Choose P3U30-5AAA2BBAA
Require Ethernet, remote networking, smart substation or IEC61850 → Must choose P3U30-5AAA2BBAC
Schneider PowerLogic P3U30 Series Universal Protection Relay Model List
- Regra de codificação do modelo (Full Interpretation)
The P3U30 series adopts the format P3U30-XXXXXXXX with 14 characters. The definition of each segment is as follows:
| Segmento de modelo | Posição | Significado | Código Opcional & Descrição |
| P3U30 | 1-5 | Série de produtos | P3U30 = Universal Protection Relay for feeder and motor protection |
| 5月6日 | 6 | Tipo de fonte de alimentação | 5 = 48-230V AC/DC |
| 6 = 24-48V AC/DC | |||
| AAA/ABA | 7-9 | Measurement Input Configuration | AAA = 3CT(1/5UM), 1Io(1/5UM), 4TV(100V/110V) |
| ABA = 4L (3CT+1Io) ring-type terminal, 4TV(100V/110V) | |||
| 1月2日 | 10 | Configuração de E/S | 1 = 16DI/4DO (without watchdog) |
| 2 = 16DI/8DO (with watchdog) | |||
| BB/BD/BC | 11-12 | Basic Communication Configuration | BB = Basic communication |
| BD = Extended communication | |||
| BC = Advanced communication | |||
| AA/AC/BA/CA | 13-14 | Digital Input Voltage + Interface de comunicação | AA = DI=220V AC/DC, RS485 only |
| AC = DI=110-230V AC/DC, Dual RJ45 + RS485 | |||
| BA = DI=24-48V AC/DC, RS485 only | |||
| CA = DI=24-230V AC/DC, Dual RJ45 + RS485 |
- Lista completa de modelos (Classified by Communication Interface)
2.1 RS485 Serial Communication Only (Without Ethernet)
| Modelo | REL Code | Fonte de energia | Measurement Input | Configuração de E/S | DI Voltage | Interface de comunicação | Cenário de aplicação |
| P3U30-5AAA2BBAA | REL52002 | 48-230V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 220V CA/CC | 1×RS485 | Traditional substation, local communication |
| P3U30-5AAA2BBBA | REL52003 | 48-230V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 24-48V CA/CC | 1×RS485 | Low-voltage control system, PLC interlocking |
| P3U30-6AAA2BBAA | REL52004 | 24-48V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 220V CA/CC | 1×RS485 | DC system, battery-powered |
| P3U30-6AAA2BBBA | REL52005 | 24-48V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 24-48V CA/CC | 1×RS485 | Equipamento pequeno, low-power application |
| P3U30-5ABA1BBAA | REL52006 | 48-230V CA/CC | 4L ring type + 4TV | 16D/4C (without watchdog) | 220V CA/CC | 1×RS485 | Feeder protection, configuração simplificada |
| P3U30-6ABA1BBAA | REL52007 | 24-48V CA/CC | 4L ring type + 4TV | 16D/4C (without watchdog) | 220V CA/CC | 1×RS485 | Distributed system, remote terminal unit |
2.2 Dual RJ45 Ethernet + RS485 Communication (Smart Type)
| Modelo | REL Code | Fonte de energia | Measurement Input | Configuração de E/S | DI Voltage | Interface de comunicação | Cenário de aplicação |
| P3U30-5AAA2BBAC | REL52008 | 48-230V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 110-230V CA/CC | 2×RJ45+1×RS485 | Smart substation, CEI 61850 |
| P3U30-5AAA2BBCC | REL52009 | 48-230V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 24-230V CA/CC | 2×RJ45+1×RS485 | International projects, multi-voltage compatibility |
| P3U30-6AAA2BBAC | REL52010 | 24-48V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 110-230V CA/CC | 2×RJ45+1×RS485 | DC smart system, monitoramento remoto |
| P3U30-6AAA2BBCC | REL52011 | 24-48V CA/CC | 3CT+1Io+4VT | 16D/8C (with watchdog) | 24-230V CA/CC | 2×RJ45+1×RS485 | IoT integration, multi-protocol support |
| P3U30-5ABA1BDAC | REL52012 | 48-230V CA/CC | 4L ring type + 4TV | 16D/4C (without watchdog) | 110-230V CA/CC | 2×RJ45+1×RS485 | Feeder automation, network redundancy |
| P3U30-6ABA1BDAC | REL52013 | 24-48V CA/CC | 4L ring type + 4TV | 16D/4C (without watchdog) | 110-230V CA/CC | 2×RJ45+1×RS485 | Distributed feeder protection, CEI 61850 |
2.3 Special Configuration Models (Wide Temperature / Extended Functions)
| Modelo | REL Code | Recursos especiais | Interface de comunicação | Observações |
| P3U30-5AAA2BBAA-W | REL52045 | Wide temperature (-25°C~+70°C) | 1×RS485 | Outdoor application, harsh environment |
| P3U30-5AAA2BBAC-W | REL52046 | Wide temperature (-25°C~+70°C) | 2×RJ45+1×RS485 | Smart outdoor equipment, remote diagnosis |
| P3U30-5ABA2BDAA | REL52047 | 4L ring terminal, extended I/O | 1×RS485 | High-current measurement, industrial monitoring |
| P3U30-5ABA2BDAC | REL52048 | 4L ring terminal, extended I/O | 2×RJ45+1×RS485 | Smart grid, feeder automation |
- Key Parameter Overview Comparison
| Categoria de parâmetro | RS485 Only Models | Ethernet + RS485 Models | Common Features |
| Protocolos de comunicação | Modbus RTU, CEI 60870-5-101/103 | Serial protocols + CEI 61850, Modbus TCP, DNP3, Ethernet/IP | All support basic serial protocols |
| Networking Capability | RS485 bus only, point-to-point / bus topology | Ethernet star/ring/redundancy (RSTP/PRP), dual-port cascading | Support standard industrial networking modes |
| Entrada Digital | Two fixed voltages: 220V / 24-48V | Wide-range voltage: 110-230V / 24-230V | 16 channels with optical isolation |
| Saída digital | 4FAZER / 8FAZER (watchdog optional) | 4FAZER / 8FAZER (watchdog optional) | Relay output, contact rating 5A/250V AC |
| Measurement Accuracy | Aula 0.2 (Current/Voltage), Aula 0.5 (Poder) | Aula 0.2 (Current/Voltage), Aula 0.5 (Poder) | Compatível com IEC 60255 |
| Funções de proteção | 40+ protections (sobrecorrente, falha de terra, subtensão, etc.) | 40+ protections (sobrecorrente, falha de terra, subtensão, etc.) | Suitable for feeder and motor protection |
| Faixa de fonte de alimentação | 24-48V or 48-230V AC/DC | 24-48V or 48-230V AC/DC | Wide voltage design for global power grid adaptation |
- Gráfico de seleção rápida (By Core Requirement)
| Core Requirement | Modelo recomendado | Principais vantagens |
| Traditional substation without network demand | P3U30-5AAA2BBAA | Baixo custo, meets basic communication |
| Smart substation with IEC 61850 | P3U30-5AAA2BBAC | Dual Ethernet ports, supports IEC 61850 Ed.1/Ed.2 |
| International project with multi-voltage environment | P3U30-5AAA2BBCC | 24-230V wide-range DI, global compatibility |
| DC system with battery power supply | P3U30-6AAA2BBAA | 24-48V power supply, baixo consumo de energia |
| Outdoor application & harsh environment | P3U30-5AAA2BBAC-W | Wide temperature design, forte anti-interferência |
| High-current measurement with ring terminals | P3U30-5ABA2BDAC | 4L ring terminals compatible with high-current CT |
- Informações Complementares
- Hardware Compatibility: All P3U30 models share identical physical dimensions (96×96×75mm) and mounting methods (Trilho DIN / panel mounting) for direct interchangeable installation.
- Funções de proteção: All models offer 40+ protection functions including overcurrent (EU>>), falha de terra (Ig), subtensão (Você<), phase sequence reversal, sobrecarga, etc., em conformidade com IEC 60255 padrão.
- Certificações: Compliant with CE, UL, CSA, CEI 61850 and other international certifications for global market use.
- Atualização de Firmware: Ethernet models support remote firmware upgrade; RS485 models require local upgrade.
- Lista de acessórios:
Front Connector: Standard 9-pin spring terminal
Communication Cable: RS485 shielded twisted pair (opcional)
Ethernet Cable: CAT5e/CAT6 industrial Ethernet cable (Ethernet models only)
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares


