EOCR-SSD-C-30DMQ is a new-generation ultra-thin compact motor protector of SSD-C series launched by Schneider Electric (formerly Samwha Korea). It supports direct wiring within 3~30A, adopts AC220V control power supply, features digital display and Q-type three-phase peak current display. It is newly added with phase unbalance and phase sequence protection functions. With smaller size and higher precision, it is fully compatible to replace traditional SSD models. It is specially designed for compact cabinet layout under three-phase unbalanced operating conditions.

  1. Explicação do código do modelo
Segmento de códigoDefinição
EOCRElectronic Over Current Relay, core category for motor protection
SSD-CSolid State Digital Compact, upgraded compact solid-state digital type; ultra-thin DIN rail mounted, successor of standard SSD series
30Current protection range: 3~30A, direct circuit wiring without external CT current transformer
DDigital tube display, real-time visible current value and fault codes
MControl power specification: AC220V±15%, 50/60Hz (industry standard M7 specification)
PPeak current display function: only displays the maximum current among three phases instead of average value, perfectly suitable for unbalanced loads
  1. Parâmetros técnicos principais
Categoria de parâmetroEspecificaçõesObservações
MarcaSchneider Elétrica (Original factory in Iksan, Korea, Samwha technology)Authorized domestic distributor: Shanghai Hanshi Electric
Tipo de produtoCompact solid-state digital protector for motor overload, phase loss and phase unbalance protectionProtection accuracy ±3%, better than ±5% of old SSD models
Rated Circuit Voltage690V e (CEI) / 600V e (UL)Universal for low-voltage three-phase motors
Tensão suportável de impulso6kV, compatível com IEC 60947-4-1Industrial surge resistance standard
Control Power SupplyAC220V±15%Exclusive specification for suffix M
Total Power Consumption≤2.5WUltra-low power consumption, stable for long-term standby
Adjustable Current3~30A stepless continuous adjustmentAdjustment ratio: 10:1
Full Protection FunctionsSobrecarga, perda de fase, locked rotor, three-phase unbalance, abnormal phase sequenceUnbalance & phase sequence protection newly added in C series, unavailable on traditional SSD
Time Delay ParametersStart delay D-Time: 0.2~30s; Trip delay O-Time: 0.2~10sWide adjustable range for heavy-duty starting motors
Output Contacts1NÃO+1NC (2SPST)Avaliação de contato: 3A/250 VCA
Display FeatureQ version: flashing three-phase maximum current + fault code alarmQuickly locate hidden single-phase overload risks
Dimensão Geral40×72×105mmNarrower than old SSD, salvando 30% cabinet space
Método de instalaçãoStandard 35mm DIN rail clip-on mountingDirect wiring replacement for old SSD products
Classe de ProteçãoIP20 (painel frontal)Indoor installation inside control cabinets
Temperatura operacional-20℃ ~ +60 ℃Adaptable to wide-range industrial temperature
Temperatura de armazenamento-40℃ ~ +85℃Safe for transportation and storage
  1. Core Differences Between New SSD-C and Traditional Standard SSD
Item de comparaçãoEOCR-SSD-C-30DMQ (New C Type)EOCR-SSD-30DM7Q (Old Standard Type)
Outline SizeUltra-thin compact design, space-saving in cabinetConventional wide body, larger space occupation
Funções de proteçãoSobrecarga + Phase Loss + Locked Rotor + Phase Unbalance + Phase SequenceOnly overload, phase loss and locked rotor protection
Protection Accuracy±3%±5%
Adjustable Time Delay RangeWider range: 0.2~30sNarrow range: 0.5~10s
Electromagnetic Interference ResistanceEnhanced EMC filter, applicable for inverter surrounding environmentsOrdinary anti-interference performance, easily affected by inverter interference
CompatibilidadeUniversal pin definition, seamless replacement for old modelsCannot be reversely replaced by new C-type products
  1. Cross-Brand Product Comparison
Marca & ModeloFaixa AtualPoder de controleDisplay ModeCore ProtectionCenários de aplicação
Schneider EOCR-SSD-C-30DMQ3~30A220VACThree-phase peak current Q displaySobrecarga / Phase Loss / Locked Rotor / Unbalance / Phase SequenceNarrow cabinets, heavy-duty motors with three-phase unbalance
Schneider EOCR-SSD-30DM7Q3~30A220VACThree-phase average current displaySobrecarga / Phase Loss / Locked RotorConventional working conditions with balanced loads
ABB CM-MSS.31P3~30A24~240V AC/DCIndicator light without digital displaySobrecarga & Phase LossSimple basic protection for general industrial control
Siemens 3RB2026-1SB02.5~32AWide universal voltageLuz indicadoraBasic overload and phase loss protectionComplete cabinet matching with Siemens PLC
Omron K8DS-PH13~30A100~240VACAverage value digital displayFull-range protectionPrecision motors for automatic production lines
  1. Full SSD-C Series Model List (Including Q Peak Current Version)
Current GradeModelo BásicoOptional Power SuffixComplete Q Peak Current Model
0.5~6AEOCR-SSD-C-05SF7:110VAC / M:220VAC / S:24~240V / C:380VEOCR-SSD-C-05DMQ
3~30AEOCR-SSD-C-30SIgual ao acimaEOCR-SSD-C-30DMQ
5~60AEOCR-SSD-C-60SIgual ao acimaEOCR-SSD-C-60DMQ

Order Accessories

DIN rail bracket: EOCR-MNT-01

Teste & calibration kit: EOCR-TEST-KIT

Custom signal extension cable: 5eu / 10eu

  1. Falhas Comuns & Exclusive Maintenance Solutions (C-Q Series)
Fenômeno de falhaMain CausesSolução de problemas & Soluções
No display on panelDisconnected 220V power supply, loose terminals, blown internal fuseMeasure terminal voltage, fasten wiring, replace 0.5A fuse
Frequent unbalance alarm & trippingThree-phase load deviation over 8%, poor line contact, phase loss of power supplyBalance motor load, tighten three-phase wiring, inspect incoming line voltage
Falso disparo & failure to startToo short D-Time start delay, underset current valueSet delay = motor starting time +1~2s; set current to 1.1 times motor rated current
Phase sequence fault alarmReversed phase sequence of three-phase incoming linesSwap any two live wire connections
Garbled flickering displayStrong electromagnetic interference from inverter, poor groundingStandardize grounding layout, keep away from inverter cables, install anti-interference filter

Ciclo de Manutenção

Inspeção diária: Check peak current value and fault alarm status

Monthly maintenance: Remove dust and tighten wiring terminals

Quarterly calibration: Verify protection action threshold

Revisão anual: Detect contact service life and replace aging components

  1. Application Environment Specifications

✅ Recommended Application Scenarios

  1. Water pumps, fãs, conveyors working under three-phase current unbalance conditions
  2. Compact control cabinets requiring ultra-thin compact protectors
  3. Heavy-duty motors for chemical stirring, metalurgia, water treatment and HVAC systems
  4. Industrial sites with strong electromagnetic interference nearby inverters

❌ Not Recommended Scenarios

  1. High-voltage motors above 690V (special high-voltage protector required)
  2. Explosion-proof hazardous areas (no original factory explosion-proof enclosure certification)
  3. Ultra-low power motors below 0.5A
  4. Long-term independent operation of single-phase motors
  5. Quick Selection Tips

New ultra-thin C-type SSD, 3 para 30 ampere range;

M stands for 220V AC power, Q shows maximum single-phase current;

Added unbalance and phase sequence protection, easy installation in narrow cabinets;

Set current to 1.1 times rated value, extend start delay by one second extra.

  1. Air Freight Compliance & Certification Qualifications
  2. Air Transportation Safety: No built-in lithium batteries or supercapacitors, fully compliant with UN38.3 standards. Shippable as general cargo without special MSDS documents.
  3. Authoritative Certifications: CE (EU), UL (América do Norte), CCC (Certificação Obrigatória da China), CSA, RoHS environmental protection certifications fully approved.
  4. Conformidade Padrão: Strictly implemented in accordance with international standard IEC 60947-4-1 for low-voltage motor protection.
Pages: 1 2

Anterior:

Deixe uma resposta

Deixe um recado