LC1DWK12p7 Schneider Capacitor Switching Contactor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

LC1DWK12p7 Schneider Capacitor Switching Contactor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

NotíciasNotícias comerciais

LC1DWK12p7 Schneider Capacitor Switching Contactor

LC1DWK12p7 is a three-phase capacitor switching contactor specially designed by Schneider Electric for reactive power compensation systems. It is mainly used to switch power capacitors so as to improve grid power factor, reduce line loss and enhance power quality.

  1. Model Segment Definition
Segmento de modeloSignificadoDescrição
LC1Contactor series codeBasic code for Schneider TeSys series contactors
DSérie de produtosTeSys D series, standard industrial contactor
CSpecial applicationDedicated for capacitor switching
KRated capacityMatches 63kVAR capacitor at 400V/50Hz
12Corrente nominal12UM (special rating for capacitor switching)
p7Tensão da bobina230Vca 50/60 Hz
  1. Main Application Scenarios

2.1 Industrial Power System Power Factor Compensation

Factory power distribution system: Heavy industries such as steel, chemical and machinery manufacturing with intensive inductive loads like motors and inverters, requiring dynamic reactive power compensation.

LC1DWK12p7 is a three-phase capacitor switching contactor specially designed by Schneider Electric for reactive power compensation systems. It is mainly used to switch power capacitors so as to improve grid power factor, reduce line loss and enhance power quality.

Substation / Distribution station: 10kV/0.4kV power distribution system adopting centralized compensation to improve overall power supply efficiency.

Production line dedicated compensation: Large production lines, compressor stations, water pump rooms, etc., automatically switching capacitors according to load changes.

2.2 Edifícios Comerciais & Instalações Públicas

Office buildings / Shopping malls: Large electrical equipment such as central air conditioning, elevators and lighting systems adopting centralized compensation to reduce electricity costs.

Centros de dados: Non-linear loads such as UPS and server clusters requiring precise compensation to maintain voltage stability.

Hospitais / Schools: Power supply systems for critical loads to improve power supply reliability and power quality.

2.3 Nova Energia & Indústrias Especiais

VP / Wind power systems: Compensate reactive power loss at the output of grid-connected inverters to meet grid connection standards.

Trânsito ferroviário: Traction substations and depots for compensating inductive reactive power of traction loads.

Mineração / Oilfield: Off-grid power supply systems in remote areas to improve power generation equipment utilization.

  1. Special Design Advantages for Capacitor Switching
  2. Pre-wired damping resistor: Suppresses inrush current (até 100 vezes a corrente nominal) durante a comutação do capacitor, protecting capacitors and contactor contacts.
  3. Early-make auxiliary contact: Ensures the damping resistor is connected first before the main contacts close, achieving inrush-free switching.
  4. Optimized contact material: Adapted to high-frequency operation (até 240 cycles/hour) and arc characteristics of capacitor switching.
  5. Wide temperature design: -25℃ ~ +60 ℃, adequado para ambientes industriais agressivos.
  6. Typical Application Topology

Power Grid → Circuit Breaker → Reactor → LC1DWK12p7 Contactor → Power Capacitor → Load

Used together with reactors to further suppress inrush current and harmonics.

Linked with power factor controllers (por exemplo, Schneider Varlogic series) to realize automatic compensation, switching capacitor banks automatically according to grid power factor.

  1. Same Series Capacitor Contactor Comparison (400V/50Hz)
ModeloMatched Capacitor CapacityTensão da bobinaCenário de aplicação
LC1DWK12p763kVAR230V eIndustrial geral & commercial compensation
LC1DWK12M763kVAR220V eStandard for Asian market
LC1DWK12U763kVAR240V eStandard for North American market
LC1DWK09p740kVAR230V eSmall compensation systems
  1. Considerações sobre seleção de chaves
  2. Capacitor capacity matching: 63kVAR for 400V system, 60kVAR for 415V system, 80kVAR for 575V system.
  3. Tensão da bobina: Tensão do circuito de controle de correspondência (230V/220V/240V AC).
  4. Frequência operacional: ≤240 cycles/hour to meet dynamic compensation requirements.
  5. Condições ambientais: Wide-temperature type suitable for outdoor and harsh industrial environments.

Core Product Advantages of LC1DWK12p7 Schneider Capacitor Switching Contactor

As a dedicated capacitor contactor in the Schneider TeSys D series, LC1DWK12p7 is designed for 63kVAR/400V three-phase capacitor switching. Its core advantages focus on four aspects: inrush current suppression, high-frequency reliability, wide environmental adaptability, compliance and easy maintenance, delivering outstanding professional performance compared with general-purpose contactors in reactive power compensation applications.

  1. Dedicated Capacitor Switching Design — Solve Inrush Current & Arc Problems Fundamentally

1.1 Pre-wired Damping Resistor + Early-make Auxiliary Contact (Core Patent Advantage)

Built-in current-limiting damping resistor: Suppresses capacitor inrush current up to 100 times the rated current during switching, protecting capacitors and contacts from overload impact.

Early-make auxiliary contact design: Ensures the damping resistor is connected to the circuit first, then the main contacts close, realizing inrush-free switching and greatly reducing contact ablation risk.

Special contact alloy: Adopts AgSnO₂ material with excellent arc resistance and welding resistance, perfectly adapting to high-frequency operation (até 240 cycles/hour) and capacitive load characteristics.

1.2 Precise Capacity Matching

Rated for direct use with 63kVAR/400V/50Hz capacitors, enabling simple selection without complex calculation and avoiding damage caused by capacity mismatch.

Compatible with 690V systems (máx.. 104kVAR), offering strong voltage adaptability for various power distribution systems.

  1. Alta confiabilidade & Durability — Industrial-Grade Stable Operation

2.1 Ultra-long Mechanical & Electrical Lifespan

Vida mecânica: ≥10 million operations, far exceeding the standard of ordinary contactors.

Vida elétrica: ≥300,000 capacitor switching cycles, meeting long-term dynamic compensation demands.

Harsh environment resistance: Operating temperature range -25℃ ~ +60℃, IP20 protection grade, suitable for high and low temperature industrial sites.

2.2 High-Frequency Operation Adaptability

Suporta até 240 switching cycles per hour, ideal for rapidly changing load scenarios such as electric arc furnaces and welding machines.

Optimized coil structure reduces temperature rise during high-frequency operation and extends service life.

2.3 Schneider Patented Process Enhancement

Core iron core with patent anti-rust technology, 5 times higher corrosion resistance for humid, salt-laden and harsh environments.

Exclusive sealing design for dustproof and moistureproof performance, reducing contact contamination and improving connection reliability.

  1. Fácil instalação & Maintenance — Lower Engineering & Ó&M Costs

3.1 Tamanho compacto & Montagem Flexível

85mm largura (3-pole standard size), saving cabinet space and supporting high-density installation.

Compatible with NS 35/7.5 DIN rail mounting and screw fixing, adapting to various installation conditions.

Screw-type clamping terminals ensure reliable connection and convenient wiring and maintenance.

3.2 Diagnóstico Inteligente & Maintenance Prompt

Equipped with QR code identification for quick access to product manuals, installation guides and technical support, simplifying on-site maintenance.

Configuração de contato auxiliar (1NÃO+2NC) supports status monitoring and fault alarm for remote diagnosis.

3.3 Low-Maintenance Design

Wear-part-free structure reduces maintenance frequency and lowers full-lifecycle cost.

Modular construction enables easy parts replacement and shortens downtime.

  1. Desempenho Elétrico & Safety Compliance — Fully Meet Industrial Standards

4.1 Electrical Safety Design

Compatível com IEC 60947-4-1 e CEI 60831 (shunt capacitor standard), ensuring safe capacitor switching.

Mechanical interlock structure prevents misoperation and improves system safety.

Built-in coil overvoltage/undervoltage protection, adapting to grid voltage fluctuation and avoiding coil burnout.

4.2 Energy Efficiency Optimization

Low coil power consumption for energy-saving operation and long-term cost reduction.

Inrush-free switching design reduces grid harmonic pollution and improves overall power quality.

4.3 Certificações Globais

Full certifications: CE, UL, CSA, CCC, EAC, Marine Approval for global application.

Green Premium product compliant with RoHS/REACH environmental standards, supporting sustainable development.

  1. System Integration Advantage — Perfectly Matches Reactive Power Compensation Solutions

5.1 Seamless Compatibility with Schneider Compensation Systems

Perfectly linked with Varlogic power factor controllers (VR6, VR12 series) to realize automatic compensation.

Matches with reactors (por exemplo, Schneider VArSet series) to further suppress harmonics and inrush current.

Can be combined with TeSys D thermal relays and circuit breakers to build a complete capacitor protection loop.

5.2 Flexible Compatibility with Various Compensation Schemes

Supports Star / Delta capacitor wiring for different capacity and voltage level capacitor banks.

Applicable to static var compensation (SVC) and dynamic var compensation (SVG front-end) systems with wide application coverage.

  1. Core Difference Comparison with Ordinary Contactors
Item de comparaçãoLC1DWK12p7 Capacitor ContactorGeneral-Purpose Contactor
Inrush SuppressionBuilt-in damping resistor + early-make contact, inrush-free switchingNo dedicated design; inrush current up to 100 vezes a corrente nominal, easy contact & dano ao capacitor
Contact MaterialSpecial AgSnO₂ alloy, arc & welding resistantOrdinary silver alloy, short service life under capacitive load
Frequência de OperaçãoAté 240 cycles/hour for dynamic compensationNormally ≤120 cycles/hour, easy overheating at high frequency
Capacity MatchingDirectly marked 63kVAR/400V, simple selectionRequires complex calculation, prone to capacity mismatch
Protection PerformanceOptimized for capacitor characteristics, sobre/subtensão & proteção contra perda de faseGeneral protection only, lacking targeted adaptation for capacitor switching
  1. Profissional & Seguro: Specially designed for capacitor switching, eliminating inrush current and arc risks fundamentally to protect equipment.
  2. Alta confiabilidade: Wide temperature tolerance, high-frequency capability and long service life for harsh industrial environments and frequent switching.
  3. Fácil instalação & Manutenção: Estrutura compacta, flexible mounting and intelligent O&M to reduce project and maintenance costs.
  4. Compatibilidade do sistema: Seamlessly integrated with Schneider compensation systems to simplify scheme design and commissioning.
  5. Global Certification: Fully compliant with international standards, adequado para indústrias, commercial and special scenarios with stable system operation guaranteed.

Anterior:

Deixe uma resposta

Deixe um recado