ABB 3BSE038415R1 (AO810V2) Módulo de saída analógica - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

ABB 3BSE038415R1 (AO810V2) Módulo de saída analógica - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

ABB 3BSE038415R1 (AO810V2) Módulo de saída analógica

It is an 8-channel analog output module of the S800 I/O series for ABB Advant 800xA system. It converts digital control signals into standard industrial analog signals (0/4-20mA ou 0-10V) to drive on-site equipment such as actuators and valves. Definição de segmento de modelo (ABB S800 I/O Naming Rule) Model Segment Meaning Detailed Description 3BSE Product series ...

  • Detalhes do produto

It is an 8-channel analog output module of the S800 I/O series for ABB Advant 800xA system. It converts digital control signals into standard industrial analog signals (0/4-20mA ou 0-10V) to drive on-site equipment such as actuators and valves.

  1. Definição de segmento de modelo (ABB S800 I/O Naming Rule)
Segmento de modeloSignificadoDescrição detalhada
3EEBProduct series prefixGeneral prefix for ABB industrial automation products, representing control system I/O modules
38415Product part numberNumeric code for unique module identification
R1Revision numberRevisão 1, standing for the first official version of the module
AO810V2Commercial modelAO = Analog Output, 8 = 8 canais, 10 = Tipo padrão, V2 = 2nd generation upgraded version
  1. Especificações Técnicas Principais (Official Data)
Categoria de parâmetroTechnical IndexObservações
Basic Characteristics
Número de canais8 canais (galvanically isolated)Each channel can be individually configured for output type
Tipo de saídaAtual / Voltage selectable0-20mA, 4-20mA, 0-5V, 1-5V, 0-10V
Resolução14-pedaço (incluindo bit de sinal)Accuracy ±0.1% Full Scale
Conversion Rate25ms por canalFull channel update cycle: 200EM
Parâmetros Elétricos
Current Output Range0-25mA (Maximum drive capability)Standard load 500Ω (4-20mA), High load 850Ω (0-20mA)
Voltage Output Range0-10VMinimum load 1kΩ
Isolation Level250V AC between channels, 500V AC between channel and backplaneCompatível com IEC 61010-1 safety standard
Fonte de energia24Em DC (±10%)Power consumption <2W
Parâmetros Ambientais
Temperatura operacional0°C to +55°CTemperatura de armazenamento: -20°C a +70°C
Umidade5% para 95% (Non-condensing)Nível de proteção IP20
Vibração / Choque5g / 11EM (Half-sine wave)Meet anti-interference requirements for industrial environments
Certificações & ConformidadeCE, UL, CSACompliant with EN 61131-2, CEI 61010-1
  1. Lista de acessórios & Requisitos de instalação

3.1 Mandatory Accessories (Must Be Used Together)

Número da peçaNomeFunção
TU810/TU812/

TU814/TU830/

TU833

Terminal UnitProvide field wiring terminals for signal connection and isolation
TB810Terminal BoardOpcional, for high-density wiring scenarios
SD811Shield ConnectorFor analog signal shield grounding and interference reduction

3.2 Especificações de instalação

Montagem em trilho DIN: 35mm standard rail complying with DIN EN 50022

Backplane Communication: Communicate with controller via S800 I/O bus backplane

Installation Clearance: Keep at least 10mm gap between modules for heat dissipation

Wiring Requirement: Use shielded twisted pair for analog signals, routed separately from power cables (spacing ≥15cm)

  1. Same Series Models & Lista de substituição entre marcas

4.1 ABB S800 I/O Analog Output Module Series

ModeloCanaisResoluçãoRecursos especiaisCenários de aplicação
AO810V2 (3BSE038415R1)814-pedaçoTipo padrão, general outputControle industrial geral, econômico
AO815V2816-pedaçoHigh precision with diagnostic functionProcess control requiring high measurement accuracy
AO820414-pedaçoRedundant output, fail-safeCritical equipment control with redundant backup required
AO890814-pedaçoHART protocol supportSmart instrument communication and remote diagnosis

4.2 Cross-Brand Replacement Solution (Correspondência de parâmetros)

MarcaModeloCanaisResoluçãoTipo de saídaCompatibility Note
SchneiderBMXDAI1605814-pedaço0/4-20mA, 0-10VAdaptable to Modicon M340/M580 system
Siemens6ES7 332-5HF00-0AB0814-pedaço0/4-20mA, 0-10VCompatible with S7-300 system, backplane replacement required
Rockwell1756-OF8816-pedaço0/4-20mA, 0-10VFor ControlLogix system, different communication protocol
DomésticoHollySys FM148A814-pedaço0/4-20mA, 0-10VCompatible with LK series DCS, desempenho de alto custo
  1. Diretrizes de seleção & Replacement Tips

5.1 Árvore de decisão de seleção (Quick Demand Matching)

  1. Channel Quantity: 8 channels satisfy most small and medium control loops; expand by parallel installation or select 16-channel models for more points.
  2. Requisito de precisão:

General control: AO810V2 (0.1% accuracy) é suficiente

Precision control: Upgrade to AO815V2 (16-pedaço, 0.05% accuracy)

  1. Capacidade de carga:

Standard load (≤500Ω): Directly use AO810V2

High load (500-850Oh): Adopt 0-20mA mode instead of 4-20mA

  1. Funções Especiais:

HART communication: Choose AO890

Redundant output: Choose AO820

Fail-safe: Choose AO825 (SIL certified)

5.2 Replacement Mnemonic Rule (3 Key Matching Elements)

Same channel quantity, no accuracy downgrade, meet load requirement, equivalent isolation performance

5.3 Replacement Precautions

  1. Compatibilidade de protocolo: ABB S800 I/O adopts Profibus DP or ABB dedicated bus; cross-brand replacement requires system compatibility evaluation.
  2. Terminal Compatibility: Terminal units of different brands are not interchangeable and shall be replaced together.
  3. Software Configuration: Reconfigure module parameters after replacement to ensure consistent output range and fail-safe logic.
  4. Redundant System: Conduct compatibility testing first for critical applications to avoid system failure.
  5. Main Application Scenarios & Casos Típicos
  6. Process Industry: Valve positioner control in chemical, petrochemical and natural gas processes
  7. Indústria de energia: Generator excitation control and transformer tap changer regulation
  8. Fabricação: Production line speed control, pressão / flow regulation
  9. Tratamento de Água: Pump inverter control and chemical dosing flow regulation

Configuração típica: AO810V2 module + TU812 terminal unit + SD811 shield connector, used to control 4-20mA pneumatic regulating valves for precise flow control.

Full List of ABB Analog Output Modules (Structured Quick Reference)

  1. Série S800 E/S (800xA/DCS System, Industrial Standard Application)
Modelo de móduloFull Part NumberCanaisRecursos principaisTipo de saídaResoluçãoAplicação Típica
AO8013BSE020514R18Tipo básico, channel isolation0/4-20mA, 0-10V12-pedaçoGeneral control, low-cost scenarios
AO8103BSE008522R18Standard configurable type0/4-20mA, 0-5V, 1-5V, 0-10V14-pedaçoControle industrial geral, medium precision
AO810V23BSE038415R1/R28V2 upgraded version, higher stability0/4-20mA, 0-5V, 1-5V, 0-10V14-pedaçoReplacement for AO810, mainstream application
AO810V2-eA3BSE038415R28Optimized for Freelance system0/4-20mA, 0-10V14-pedaçoFreelance DCS system
AO8153BSE008523R18High precision with diagnosis0/4-20mA, 0-10V16-pedaçoControle de processo & precision regulation
AO8203BSE008546R14Redundant output, fail-safe0/4-20mA14-pedaçoCritical equipment control with redundancy
AO8453BSE008547R18Redundant output with OSP preset value0/4-20mA14-pedaçoSafety-related systems, communication fault protection
AO845A3BSE018107R18AO845 upgrade, HART pass-through0/4-20mA14-pedaçoSmart instrument communication & remote diagnosis
AO8903BSE008548R18Intrinsecamente seguro, HART0/4-20mA (A partir de agora)14-pedaçoHazardous Area Zone 1/2, explosion-proof required
AO8953BSE018108R18High precision intrinsically safe0/4-20mA (A partir de agora)16-pedaçoPrecision control in hazardous areas
  1. S900 I/O Series (ATEX Explosion-Proof for Hazardous Areas)
Modelo de móduloFull Part NumberCanaisExplosion-Proof GradeRecursos principaisTipo de saídaApplicable Area
AO920S3KDE175531L92004Ex ia IIC T4Isolated, intrinsecamente seguro0/4-20mAZone 1/2, no HART required
AO920N3KDE175533L92004Ex ia IIC T4Non-isolated, intrinsecamente seguro0/4-20mAZone 1/2, cost priority
AO920B3KDE175532L92004Ex ia IIC T4Enhanced isolated, intrinsecamente seguro0/4-20mAZone 1/2, high anti-interference
AO930S3KDE175531L93004Ex ia IIC T4Isolated with HART0/4-20mAZone 1/2, smart instrument connection
AO930N3KDE175533L93004Ex ia IIC T4Non-isolated with HART0/4-20mAZone 1/2, HART + cost priority
AO930B3KDE175532L93004Ex ia IIC T4Enhanced isolated with HART0/4-20mAZone 1/2, HART + high anti-interference
DSAX4523KDE175534L94528Ex ia IIC T4High-density, intrinsecamente seguro0/4-20mAZone 1/2, multi-channel demand
  1. AC500 PLC S500 Series (Modular PLC Application)
Modelo de móduloFull Part NumberCanaisRecursos principaisTipo de saídaResoluçãoCPU compatível
AO5231SAP250200R000116Alta densidade, software configurable0/4-20mA, 0-10V, ±10V12-pedaçoPM5xx series, AC500-eCo
AO5621SAP250201R00014Alta precisão, resposta rápida0/4-20mA, 0-10V, ±10V16-pedaçoPM5xx series, high-performance application
AX5211SAP250100R00014AI/4AOMixed I/O, economia de espaço0/4-20mA, 0-10V12-pedaçoCompact system with limited I/O points
AX5221SAP250101R00018AI/8AOHigh-density mixed I/O0/4-20mA, 0-10V, Pt10012-pedaçoMedium system with multi-function demand
500MBA021MRB150003R00018Tipo básico, econômico0/4-20mA, 0-10V12-pedaçoAC500 basic series
  1. Other Series (Cenários de aplicações especiais)

4.1 Advant Master Series

Modelo de móduloNúmero da peçaCanaisCaracterísticasAplicativo
AO8003BSE008521R18Basic analog outputAdvant Master DCS system

4.2 Safety-Related Modules (SIL Certified)

Modelo de móduloNúmero da peçaCanaisSIL LevelCaracterísticasAplicativo
AO8253BSE018109R14SIL 2Fail-safe, redundant outputSafety Instrumented System (SIS)
  1. Mnemônico de seleção & Key Parameter Comparison

5.1 Selection Rule

System Matching → Channel Quantity → Accuracy → Explosion-Proof → Special Functions

System Matching: S800 for 800xA, S900 for explosion-proof, AC500 for PLC

Channel Quantity: 4/8/16 channels selected by control loop quantity

Precisão: 12-pedaço (Básico), 14-pedaço (Padrão), 16-pedaço (Precisão)

Explosion-Proof: Non-explosion-proof (S800), Intrinsecamente seguro (S900)

Funções Especiais: HART (AO845A/AO890/AO930), Redundant output (AO820/AO845), Fail-safe (AO825)

5.2 Key Parameter Comparison Table

SérieTypical AccuracyMax Load (4-20mA)Isolation LevelTemperatura operacionalSuporte de redundância
S800±0,1%500Oh (Padrão) / 850Oh (Alto)250V AC between channels0-55℃Partial models (AO820/AO845)
S900±0,1%750OhEx ia IIC-20-60℃Opcional
AC500±0.2%600Oh500V AC between channels0-60℃Não
  1. Instructions & Notas
  2. Regra de nomenclatura de modelo:

AO = Analog Output

Digit = Channel quantity (por exemplo. 8 = 8 canais)

Suffix V2 = 2nd generation upgraded version

Suffix S/B/N (S900) = Isolated / Enhanced Isolated / Non-isolated

Suffix -eA = Optimized for Freelance system

  1. Combinação de acessórios:

S800 series: Match with TU810/TU812/TU814/TU830/TU833 terminal units

S900 series: Match with SA910S/SA920S terminal units

AC500 series: Direct DIN rail mounting with integrated terminals

  1. Replacement Principle:

Higher version can replace lower version within the same series (AO810V2 replaces AO810)

Cross-series replacement requires system and protocol compatibility check

Accuracy and channel quantity shall not be lower than original module

Selected Application Cases of ABB Analog Output Modules (Full Industry Coverage + Configuração & Dimensão de valor)

  1. Poder & Energy Industry (Mainly S800 I/O, Alta confiabilidade & Redundancy Demand)

1.1 Thermal Power Plant Boiler Combustion Control System (AO810V2+AO845A)

End User: Large state-owned power plant (600MW unit)

Configuração principal:

Main Controller: AC800M redundant controller (PM865)

Saída Analógica: 8 pcs AO810V2 (feed water regulating valve, forced/draught fan inverter control) + 2 pcs AO845A (fuel valve redundant output)

Terminal Unit: 10 pcs TU812 + SD811 shield connector

Realized Functions:

Precisely control boiler feed water flow, air flow and fuel supply via 4-20mA signals to optimize combustion efficiency (excess air factor controlled at 1.15-1.2)

AO845A redundant output keeps fuel valve at safe opening during communication failure, compatível com IEC 61850

Real-time regulation of turbine inlet valve to match grid load demand

Customer Benefits:

Boiler efficiency increased by 2.3%, economizando cerca de 12,000 tons of standard coal annually

NOₓ emission reduced by 18%, meeting ultra-low emission standard

System availability up to 99.99%, reducing unplanned shutdowns

1.2 Wind Farm Pitch Control System (AO815+AO820)

End User: Multinational wind power operator (100MW wind farm)

Configuração principal:

Pitch Controller: AC800M + 3 pcs AO815 (high-precision pitch angle control) + 3 pcs AO820 (redundant safety chain output)

Tipo de sinal: 0-10V (pitch motor servo control) + 4-20mA (safety brake control)

Realized Functions:

Dynamically adjust blade angle (0-90°) according to wind speed and grid frequency to maximize wind energy capture

16-bit high precision of AO815 ensures pitch angle control error <0.1% and improves power generation efficiency

AO820 redundant output triggers safety brake rapidly in emergency to guarantee equipment safety

Customer Benefits:

Annual power generation increased by 3.2%, revenue increased by about 2.1 million CNY

Blade fatigue damage reduced by 25%, service life extended

Compliant with GL 2010 wind power safety standard and TÜV certified

  1. Indústria Petroquímica (S800/S900, Explosion-Proof & High Precision Demand)

2.1 Refinery Distillation Column Control System (AO810V2+AO890)

End User: Integrated refining & chemical enterprise (10 million tons/year refining capacity)

Configuração principal:

Distillation Unit: 800xA system + 6 pcs AO810V2 (reflux pump inverter, reboiler steam valve control) + 2 pcs AO890 (tower bottom temperature control for hazardous area)

Explosion-Proof Level: AO890 meets Ex ia IIC T4 for Zone 1 hazardous area

Realized Functions:

Precisely control reflux ratio (0.5-3.0) and tower bottom temperature ( ±0.2°C ) to maintain mass and energy balance

HART function of AO890 realizes remote diagnosis of smart valve positioner and early warning of sticking fault

MPC algorithm optimizes product purity through analog output modules

Customer Benefits:

Gasoline product purity increased by 0.5 percentage points, annual premium income about 8 million CNY

Steam consumption reduced by 12%, annual energy cost saving about 3.5 million CNY

Unplanned shutdown reduced by 4 times per year, avoiding loss of about 20 million CNY

2.2 Chemical Reactor Temperature & Controle de pressão (AO815+AO845A)

End User: Fine chemical enterprise (pesticide intermediate production)

Configuração principal:

Reactor Control: AC800M + 4 pcs AO815 (heating/cooling system control) + 2 pcs AO845A (pressure regulating valve redundant output)

Tipo de saída: 4-20mA (proportional valve control) + 0-10V (heating power control)

Realized Functions:

Temperature control accuracy up to ±0.1°C, pressure control accuracy ±0.02MPa, meeting fine chemical synthesis requirements

AO815 diagnostic function monitors valve status in real time and early warns leakage risk

Precisely control feeding rate and reaction time in batch production to improve product consistency

Customer Benefits:

Product yield increased from 92% para 99.5%, reducing waste disposal cost

Reaction cycle shortened by 15%, annual production capacity increased by 20%

Safety risk reduced and passed HAZOP analysis certification

  1. Indústria de transformação (S800/AC500, Configuração flexível & Fast Response)

3.1 Automotive Painting Workshop Precision Control (AO815)

End User: Joint venture automobile manufacturer (300,000 vehicles annual output)

Configuração principal:

Painting Line: 800xA system + 12 pcs AO815 (12 sets of painting valves and coating transfer pump control)

Tipo de sinal: 4-20mA (coating flow control, accuracy 0.01L/min)

Realized Functions:

Dynamically adjust nozzle flow based on vehicle 3D model data to achieve uniform coating thickness (±5μm)

HART communication monitors valve status in real time and early warns blockage or wear

Synchronize with robot trajectory to ensure painting quality on complex curved surfaces

Customer Benefits:

Coating rework rate reduced by 8%, annual coating cost saving about 4.5 million CNY

Production tact improved by 10%, annual capacity increased by 30,000 vehicles

VOCs emission reduced by 12%, meeting environmental standards

3.2 PV Module Laminator Temperature Control (AO810V2)

End User: Leading PV enterprise (5GW module annual output)

Configuração principal:

Laminator: AC500 PLC + 4 pcs AO810V2 (8 heating zones, 2 channels per module in parallel)

Tipo de saída: 0-10V (heating power control, 14-resolução de bits)

Realized Functions:

PID algorithm precisely controls heating plate temperature with uniformity ±0.5°C to ensure full cross-linking of EVA film

Automatically compensate heat loss by monitoring temperature difference of each heating zone

Link with vacuum system to realize precise control of pressure-temperature-time

Customer Benefits:

Module yield increased from 92% para 98%, annual loss reduction about 60 million CNY

Energy consumption reduced by 18%, annual electricity saving about 2.8 million CNY

Equipment maintenance cycle extended by 50%, reduzindo o tempo de inatividade

  1. Tratamento de Água & Environmental Protection Industry (AC500/S800, Economia de energia & Stable Operation)

4.1 Municipal Wastewater Treatment Plant Aeration System (AO810V2+AC500)

End User: Municipal wastewater treatment plant (500,000 tons daily treatment capacity)

Configuração principal:

Aeration Tank Control: AC500 PM573 + 6 pcs AO810V2 (12 Roots blower inverter control)

Control Logic: PID regulation based on dissolved oxygen (FAZER) concentration (2-4mg/L)

Realized Functions:

Dynamically adjust blower speed according to inlet water quality and flow to precisely control aeration volume

Alternate operation of multiple blowers to balance equipment wear and extend service life

Link with online water quality analyzer to realize precise aeration and avoid over-oxygenation

Customer Benefits:

Blower energy consumption reduced by 25%, annual electricity saving about 1.8 million CNY

Sludge production reduced by 15%, lowering treatment cost

Effluent quality stably meets Class 1-A standard of GB 18918-2002

4.2 Waterworks Chemical Dosing System (AO523+AC500-eCo)

End User: County-level water supply company (100,000 tons daily water supply)

Configuração principal:

Dosing Room: AC500-eCo + 2 pcs AO523 (16 canais, PAC & PAM dosing pump control)

Tipo de saída: 4-20mA (dosing pump frequency control, 0-50Hz)

Realized Functions:

Automatically calculate dosing amount based on raw water turbidity, pH and flow for precise dosing control

Link with sedimentation tank liquid level and effluent turbidity to realize closed-loop control

Historical data recording and trend analysis to optimize dosing strategy

Customer Benefits:

Chemical consumption reduced by 12%, annual cost saving about 350,000 CNY

Effluent turbidity stably below 0.5NTU, improving water supply quality

Manual operation reduced and labor intensity lowered

  1. Indústria Metalúrgica (S800, High Load & Anti-Interference)

5.1 Steel Hot Rolling Reheating Furnace Control (AO810+AI810)

End User: Large iron & steel group (hot rolled coil production line)

Configuração principal:

Reheating Furnace: AC800M redundant controller + 5 pcs AO810 (gas flow valve & air flow valve control) + 5 pcs AI810 (temperature acquisition)

Tipo de saída: 4-20mA (proportional regulating valve control, load 800Ω)

Realized Functions:

Zoned furnace temperature control (1200-1250°C) with temperature deviation within ±5°C

Optimize air-fuel ratio (1.05-1.1) to improve combustion efficiency and reduce NOₓ emission

Link with rolling mill speed to realize precise billet temperature control

Customer Benefits:

Furnace thermal efficiency increased by 3%, annual gas cost saving about 5 million CNY

Steel billet oxidation loss reduced by 0.2%, annual output increase about 12,000 tons

Product thickness tolerance improved from ±0.15mm to ±0.08mm, upgrading product quality

  1. Application Selection Key Points (Seleção & Dimensão de valor)

6.1 Module Selection Matching Table

IndústriaCore DemandRecommended ModulePrincipais recursos
PoderRedundancy & Alta confiabilidadeAO845A/AO820Redundant output, fail-safe, CEI 61850 compliant
QuímicoExplosion-Proof & High PrecisionAO890/AO815Intrinsecamente seguro, 16-precisão de bits, HART communication
FabricaçãoFast Response & UniformityAO815/AO810V2Resposta rápida, 14/16-precisão de bits, channel isolation
Tratamento de ÁguaEconomia de energia & EstabilidadeAO810V2/AO523Multi-channel, baixo consumo de energia, PID optimization
MetalurgiaHigh Load & Anti-InterferenceAO810850 high load capacity, 500V isolation

6.2 Core Value Formula

Application Value = Quality Improvement from Higher Precision + Cost Saving from Energy Reduction + Downtime Loss Reduction from Higher Reliability

6.3 Key Success Factors for Implementation

  1. System Matching: S800 for 800xA/DCS, AC500 for PLC, S900 for explosion-proof areas
  2. Complete Accessories: Terminal unit (TU810/812/830) + shield connector (SD811) are essential
  3. Parameter Optimization: Select current/voltage output according to load type and set proper fail-safe value
  4. Diagnosis Utilization: Enable HART function for predictive maintenance and lower operation cost

 