Compressor de rolagem Danfoss SM147A4ALB - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Compressor de rolagem Danfoss SM147A4ALB - Contator,disjuntor,sensor,Codificador,CLP,Conversor

elétrica/

Compressor de rolagem Danfoss SM147A4ALB

(Compressor scroll hermético Performer) Pedido nº.: 120H0191, a fixed-speed scroll unit from the Danfoss SM series, designed for R22 central air conditioning applications. ✅ Model Decoding SM: Performer scroll series, air-conditioning duty 147: Displacement size 193.5 cm³/rev A: Motor version 4: 3-phase 380~415V 50Hz / 460V 60Hz ALB: Oil sight glass, internal motor protection, ODF ...

  • Detalhes do produto

(Artista hermético scroll compressor)

Pedido nº.: 120H0191, a fixed-speed scroll unit from the Danfoss SM series, designed for R22 central air conditioning applications.

✅ Model Decoding

SM: Performer scroll series, air-conditioning duty

147: Displacement size 193.5 cm³/rev

UM: Motor version

4: 3-phase 380~415V 50Hz / 46060 Hz

ALB: Oil sight glass, internal motor protection, ODF brazed connections, no economizer

📌 Core Technical Specifications

ItemParâmetro
RefrigeranteR22 (compatible only with R22 mineral oil 160P)
Fonte de energia3Ph 380–415V 50Hz / 46060 Hz
Cooling Capacity32.6kW@50Hz;43.6kW@60Hz
Deslocamento193.5 cm³/r
Rotation Speed2900rpm(50Hz) / 3500rpm(60Hz)
RLA Rated Load Current20.7UM
LRA Locked Rotor Current147UM
MOC Maximum Operating Current26UM
Peso líquido67 kg, Peso bruto 71.75 kg
Pipe ConnectionsODF brazed, discharge 7/8″
ContornoOuter diameter φ243mm, height 509mm
CertificaçõesCE / UL / UKCA
Controle de capacidadeVelocidade fixa, sem frequência variável
Economizador❌ Sem porta do subcooler/economizador
Carga máxima de refrigerante7.9kg

🧊 Aplicações Típicas

Comercial refrigerado a ar / unidades de ar condicionado centrais refrigeradas a água

Resfriadores modulares, retrofit de compressor de parafuso, refrigeradores de água industriais

Temperatura constante comercial & condicionadores de ar de umidade (Somente sistema R22; não pode substituir diretamente os modelos R407C/R410A)

⚠️ Manutenção & Notas de seleção

  1. Óleo de refrigeração: 160Óleo mineral P. O óleo sintético POE não deve ser misturado. A substituição do compressor requer óleo simultâneo & troca de filtro de óleo.
  2. Proteção térmica do motor integrada. Protetor de sequência de fase externa e proteção de alta/baixa pressão são recomendados.
  3. Operação de unidade única; a instalação paralela de vários compressores requer solução de equalização de óleo (tamanho da porta de equilíbrio de óleo 1-3/4″ Rotolock).
  4. Pressão operacional máxima permitida: Lado alto 29,4bar, lado baixo 25bar.
  5. Foco na inspeção de segunda mão: Resistência de isolamento, inter-turn test, oil colour, internal abnormal noise, high/low pressure leak test.

🔁 Equivalent / Referências Alternativas

SM147A3ALB: Different voltage version (código 3)

SM147A4CLB: Difference in connection and accessory configuration

SZ147A4ALB: Same displacement, for R407C (não diretamente intercambiável; refrigerant and lubricant differ)

SM147A4ALB Starting & Protection Circuit Selection List (3Ph 380~415V/50Hz, R22 Performer Scroll)

Compressor base electrical data: RLA=20.7A; MOC maximum continuous operating current=26A; LRA locked rotor current=147A; The compressor has built-in motor thermal protection. Complete external electrical and refrigerant pressure protection is still mandatory.

  1. Main Circuit Component Selection
ComponenteEspecificaçãoObservações
3-phase Main ContactorAC-3 400V ≥32A, coil AC220V/AC380V optionalSchneider LC1D32, LC1E32; AC-3 rated to withstand LRA inrush. AC-1 contactors are prohibited.
MCCB Molded Case Circuit BreakerType D 3P, rated 40A, instantaneous trip 10InType D for motor starting inrush, proteção contra curto-circuito. Type C not permitted.
Relé de sobrecarga térmicaFaixa de ajuste:18~24A, 3P, reinicialização manualSetpoint approx. 21UM; acts as secondary backup overload protection and cannot replace the compressor internal thermal protector.
Cabo de alimentação principalCopper ≥4mm² power cableUnidade única, length ≤30m; upgrade to 6mm² for long runs, use crimp lugs
Crankcase Heater220V, 80C, AC220VOil sump heating; mínimo 8 hours preheating before startup. Heater circuit independent and cut off before compressor starts.
  1. Refrigerant Pressure Protection (safety chain wired in series with contactor coil circuit)
DispositivoModelo recomendadoContextoModo de reinicialização
High Pressure SwitchDanfoss KP5 (alta pressão)Viagem:27bar; Reiniciar:21barReinicialização manual (obrigatório), R22 service
Low Pressure SwitchDanfoss KP1 (baixa pressão)Viagem:1.8bar; Reiniciar:3.2barRedefinição automática, guards against low suction liquid floodback / low refrigerant charge
Oil Differential Pressure Protection (opcional)Danfoss MP54Trip if oil differential pressure <2.5bar with 120s delayStrongly recommended for large chillers

III. Sequência de fases & Proteção contra perda de fase (obrigatório)

Sequência de fase / relé de perda de fase: 3-fase 380V, detects wrong phase, perda de fase & 3-desequilíbrio de fase

Recomendação: Schneider RM22TG20 ou relé de proteção trifásico doméstico

Lógica: Corte a bobina do contator em caso de condição de fase anormal. A rotação reversa do compressor de rolagem pode destruir as embalagens de rolagem em segundos.

  1. Circuito de Controle (Controle AC220V)
  2. Fornecimento de controle: AC220V com disjuntor miniatura C10 (10UM)
  3. Corrente de segurança em série para circuito de bobina: Proteção de sequência de fases NC → pressostato de alta pressão NC → pressostato de baixa pressão NC → Diferencial de óleo (NF opcional) → Botão Iniciar/Parar → Bobina do contator
  4. Contatos auxiliares: Contator NA contato auxiliar para travamento; alarme de falha conectado a contatos NA de cada dispositivo de proteção.
  5. Regras rígidas para controle de inicialização do compressor Scroll
  6. Atraso mínimo de desligamento: Espere pelo menos 3 minutos após o desligamento antes de reiniciar; é recomendado um atraso mínimo de parada de 180s do controlador.
  7. Máximo de partidas por hora: ≤6 vezes. Partidas frequentes aceleram o desgaste do rolamento e do enrolamento do scroll.
  8. Operações proibidas: Start with pressure differential, test rotation in reverse, start without crankcase preheating.
  9. After internal protector trips: Power must be cut for cooling and reset. Do not repeatedly force power on for trial runs.
  10. Optional Sensors & Acessórios

Discharge temperature sensor (opcional): PT100, discharge overtemperature protection for high-temperature R22 operation

Transformador de corrente (opcional): 25/5UM, for real-time current monitoring by unit controller

Terminais: Crimp lugs recommended for compressor terminals, tightening torque 3.5~4N·m per Danfoss manual

VII. Simplified Typical Control Sequence

Power on → Phase sequence self-check OK → Crankcase heater energized → Preheating timer satisfied → Start enable signal → Contactor pulls in, compressor runs.

Trip on high pressure (reinicialização manual), baixa pressão, perda de fase / wrong phase: contactor de-energized immediately, unit stops and triggers fault alarm.

VIII. Lista de verificação de armadilhas de seleção

  1. O relé térmico é apenas proteção de backup. O protetor térmico embutido no compressor será ativado primeiro. Não use relé térmico como única proteção do motor.
  2. A proteção de alta pressão deve usar reinicialização manual. Os pressostatos de alta pressão com reinicialização automática violam os requisitos de segurança.
  3. A proteção de sequência de fase nunca deve ser omitida; a rotação reversa pode arruinar as placas de rolagem em dezenas de segundos.
  4. O aquecedor do cárter não pode ser omitido. Para óleo mineral R22, o refrigerante se dissolve no óleo em baixa temperatura de espera; inicialização sem pré-aquecimento corre o risco de sofrer convulsões devido à falta de petróleo.

Série Danfoss Performer SM (Rolagem de velocidade fixa R22, unidade única) Lista completa de modelos

SM series: Refrigerante R22, óleo mineral 160P, compressores scroll para ar condicionado; Série SZ com a mesma área ocupada para R407C; A série SY cobre maior faixa de deslocamento.

Regra de nomenclatura: SM+código de deslocamento+código do motor+código de tensão+sufixo (conexões/acessórios); Código 4 = 380~415V 50Hz /460V 60Hz (main domestic engineering variant; SM147A4ALB uses code 4)

  1. Base Displacement Core Models (bare unit without ALB/CLB suffix)
Modelo BásicoDisplacement cm³/revCooling Capacity kW@50HzObservações
SM084112.0816.1Small modular units, unidades de fan coil
SM090120.517.3Air-cooled modular, large residential central AC
SM100127.218.5Commercial air conditioning
SM110144.220.8Water chillers
SM112151.522.1Short body version
SM115156.823
SM120166.624.6Mainstream modular chiller model
SM124169.525.4Corpo curto
SM147193.532.6Bare model of your SM147A4ALB
SM148194.533SM147 upgraded variant
SM160210.135.4Medium water chillers
SM161216.636.6
SM17022938.8
SM17523340.2
SM18024141.8
SM185249.943.7Largest single unit in SM range
SM200254.446.1Older large SM, mostly superseded by SY series for new projects
SM220288.452.7Older large SM
SM242333.261.3Older large SM
SM24834264Older large SM
SM444597117Built-in tandem parallel compressor
SM483649.8127Built-in tandem parallel compressor
  1. SM147 Full Suffix Variants (subfamily of your compressor)

SM147 bare unit, voltage codes: 3 /4 /9

SM147A3ALB: Código de tensão 3 variante

SM147A4ALB: Seu modelo, 380~415V 50Hz, ODF brazed ports, oil sight glass, no economizer, Order No.120H0191

SM147A4CLB: Different connection style, Rotolock port

SM147A9ALB: 60Hz North American voltage version

Explicação do sufixo:

ALB = ODF brazed pipe connections, oil sight glass, internal thermal protection, no economizer

CLB = Rotolock flange connections, oil sight glass, internal thermal protection

III. Voltage Code Definition (middle digit of model)

3: 200–230V 3-phase 60Hz

4: 380–415V 50Hz /460V 60Hz (main domestic engineering model)

9: 380V 3-phase 60Hz (North American unit)

  1. Platform Differentiation (avoid selection error)
  2. SM: R22, óleo mineral 160P (this list)
  3. SZ: Same outer dimensions, R407C, POE synthetic oil, cannot directly replace SM
  4. SI: Larger displacement range, R22, high-capacity water chillers (SY240, SY300, SY380, SY550 etc., not part of SM series)
  5. End-of-Life Notice

SM200/SM220/SM242/SM248 are legacy large SM models, mostly discontinued. New projects are recommended to adopt SY series. SM084~SM185 remain mainstream stocked models.

Série Danfoss Performer SM (R22) Current Parameter Table

Observação: Power supply 3Ph 380~415V 50Hz; RLA=Rated Load Current; MOC=Maximum Continuous Operating Current; LRA=Locked Rotor Current; all single units, tandem compressors listed separately.

ModeloDisplacement cm³/revCooling Capacity kW@50HzRLA(UM)MOC(UM)LRA(UM)
SM084112.0816.111.214.184
SM090120.517.312.115.290
SM100127.218.512.81694
SM110144.220.814.418106
SM112151.522.114.818.5108
SM115156.82315.419.3112
SM120166.624.616.220.3118
SM124169.525.416.620.8122
SM147193.532.620.726147
SM148194.5332126.3149
SM160210.135.422.528.1160
SM161216.636.623.229163
SM17022938.824.330.4171
SM17523340.225.131.4176
SM18024141.82632.5182
SM185249.943.72733.8188
SM200254.446.128.435.5196
SM220288.452.732.240.3222
SM242333.261.336.846254
SM2483426438.247.7262

Tandem Integrated Compressors (dual scroll block)

ModeloDisplacement Cm³/revCooling Capacity kW@50HzRLA(UM)MOC(UM)LRA(UM)
SM44459711764.580.6440
SM483649.812770.287.8478

Notas Suplementares

  1. This table applies to suffix code 4 versões (A4ALB/A4CLB). Code3/9 variants (220V trifásico, 60Hz North America) have different current values and must not use this table.
  2. Thermal overload relay setting recommendation: RLA × 1.02 ~ 1.05, used as backup protection and shall not exceed MOC.
  3. LRA locked rotor current is used for contactor and circuit breaker short-time inrush sizing only, not continuous current rating.
  4. SM series only works with R22 + 160P mineral refrigeration oil; SZ series (R407C) of identical external shape has different current parameters and shall not be mixed.