ABB M1M-2TAZ664052R0007 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

ABB M1M-2TAZ664052R0007 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

medidor de eletricidade/

ABB M1M-2TAZ664052R0007

M1M: Unidade de gerenciamento e proteção de motor série ABB M1M (Motor Protection Controller) 2TAZ664052R0007: Corresponding ABB original order number / material code Product Type Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control. Core Functions Overload, locked-rotor, and underload protection Phase sequence, perda de fase, and phase imbalance protection Earth fault / ...

  • Detalhes do produto

M1M: Unidade de gerenciamento e proteção de motor série ABB M1M (Motor Protection Controller)

2TAZ664052R0007: Corresponding ABB original order number / material code

  1. Tipo de produto

Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.

  1. Funções principais

Sobrecarga, locked-rotor, and underload protection

Sequência de fase, perda de fase, and phase imbalance protection

Falha de terra / proteção contra fuga à terra

Motor operating status monitoring and fault output

  1. Mesma série & Modelos Alternativos

Mesma série: Full ABB M1M series (M1M 01/02/03 and other current ratings)

Upgraded alternatives: ABB M102 / M2M series (functionally compatible with enhanced performance)

Alternativas entre marcas: Siemens 3RB series, Schneider EOCR series motor protection relays

  1. Aplicações Típicas

Protection for three-phase asynchronous motors such as industrial fans, bombas de água, transportadores, e compressores, as well as automated production lines and factory low-voltage power distribution systems.

ABB M1M Series Digital Multifunction Power Meters

  1. Significado do modelo & Posicionamento do produto

Análise do modelo

M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)

Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions

Exemplo de modelo completo: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)

Posicionamento do produto

ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, análise de qualidade de energia, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.

  1. Full Series Comparison
ModeloFunções principaisInterface de comunicaçãoE/STensão de alimentaçãoPedido de amostra nº.
M1M 10Basic energy measurement, sem exibiçãoNenhumNenhumNo auxiliary power required2TAZ661010R2000
M1M 12Basic energy measurement, Indicação LEDNenhumNenhumNo auxiliary power required2TAZ661210R2000
M1M 15Multifunction measurement, Visor LCDModbus opcionalNenhum100–230V AC/DC2TAZ661510R2000
M1M 20Multifunction measurement, Visor LCDModbus opcionalNenhum100–230V AC/DC2TAZ662010R2000
M1M 30Advanced measurement, análise de qualidade de energiaOptional Modbus/EthernetOptional 2DI/2DO100–230V AC/DC2TAZ663010R2000
M1M 30 E/SAdvanced measurement + I/O controlModbus RTU2DI/2DO100–230V AC/DC2TAZ663012R2001
M1M 30 EthernetAdvanced measurement + EthernetModbus TCP/IPNenhum100–230V AC/DC2TAZ663011R2001
  1. Especificações técnicas (M1M 30 Série)

Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (compatível com IEC 62053-22), reactive energy class 2

Measured parameters: Three-phase voltage/current, active/reactive/apparent power, fator de potência, freqüência, medição de energia (forward/reverse), análise harmônica (selected models)

CT input: Standard 1A/5A, supports star (3E) or delta (2E) conexão

Proteção de entrada: IP51 (painel frontal), IP20 (terminais)

Montagem: 35mm trilho DIN, 18mm largura (1 módulo)

  1. Cenários de aplicativos principais
  2. Sub-metering in commercial buildings (iluminação, AVAC, power circuits)
  3. Power distribution system monitoring and energy efficiency analysis in industrial plants
  4. Power quality monitoring in data centers
  5. Real-time electrical parameter monitoring in low-voltage distribution cabinets
  6. Power generation metering for renewable energy systems (VP / energia eólica)
  7. Modelos Alternativos & Comparação de marcas

Upgraded Alternatives (Mesma marca)

Function expansion: ABB M2M series (maior precisão, more communication protocols)

Versão básica: ABB M1M 10/12 (basic energy metering, menor custo)

Alternativas entre marcas

MarcaSubstituição recomendadaNotas de compatibilidade
SchneiderPowerLogic PM5000 seriesSimilar functions, compatible communication protocols
SiemensSENTRON PAC seriesComparable measurement accuracy, supports Modbus
Domestic alternativesAcrel PZ series, Chint DTSU seriesVantagem de custo, compatible basic functions
  1. Diretrizes de seleção
  2. Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
  3. Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
  4. Control needs: Digital input/output required → M1M 30 E/S
  5. Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements

Complete List of ABB Multifunction Power Meters

This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, parâmetros técnicos, números de pedido, and application scenarios for easy selection and procurement reference.

  1. M1M Series (System pro M, Modular DIN-Rail Mounted)

ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Apenas 18 mm de largura (1 módulo) and supports hot-swap.

I.1 Basic Metering Type (No Display / LED Indication)

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SFonte de energiaPedido de amostra nº.Aplicativo
M1M 10Three‑phase energy measurement (sem exibição)Active 0.5S, Reactive 2NenhumNenhumNo auxiliary power2TAZ661010R2000Basic energy statistics, low‑cost applications
M1M 12Three‑phase energy measurement (Indicação de status LED)Active 0.5S, Reactive 2NenhumNenhumNo auxiliary power2TAZ661210R2000Simple circuit monitoring, indicação de falha

I.2 Multifunction Display Type (LCD Display)

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SFonte de energiaPedido de amostra nº.Aplicativo
M1M 15Three‑phase full‑electrical measurement, Visor LCDActive 0.5S, Reactive 2Optional Modbus RTUNenhum100–230V AC/DC2TAZ661512R2000Sub‑metering in commercial buildings, industrial monitoring
10239994
M1M 15 E/SFull‑electrical measurement + 2DI/2DOActive 0.5S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ661512R2001Local alarm/control, equipment interlock
M1M 20Full‑electrical + THD measurement, Visor LCDActive 0.2S, Reactive 2Optional Modbus RTUNenhum100–230V AC/DC2TAZ662012R2000Industrial energy efficiency analysis, power quality monitoring
10239996
M1M 20 E/SFull‑electrical + THD + 2DI/2DOActive 0.2S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ662012R2001Controle local, saída de alarme
M1M 20 EthernetFull‑electrical + THD + EthernetActive 0.2S, Reactive 2Modbus TCP/IPNenhum100–230V AC/DC2TAZ662014R2000Network integration, monitoramento remoto

I.3 Advanced Power Quality Type

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SFonte de energiaPedido de amostra nº.Aplicativo
M1M 30Full‑electrical + análise harmônica (up to 40th), registro de dadosActive 0.2S, Reactive 2Optional Modbus RTUNenhum100–230V AC/DC2TAZ663012R2000Power quality analysis, energy optimization
10239997
M1M 30 E/SFunções completas + 2DI/2DOActive 0.2S, Reactive 2Modbus RTU2DI/2DO100–230V AC/DC2TAZ663012R2001Controle local + alarme, equipment interlock
M1M 30 EthernetFunções completas + EthernetActive 0.2S, Reactive 2Modbus TCP/IPNenhum100–230V AC/DC2TAZ663014R2000Remote power quality monitoring, system integration
M1M 30 I/O EthernetFunções completas + 2DI/2DO + EthernetActive 0.2S, Reactive 2Modbus RTU/TCP2DI/2DO100–230V AC/DC2TAZ663014R2001Smart power distribution systems, energy management

Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.

  1. M2M Series (System pro M compact, Panel Mounted)

ABB mid-range power quality analyzers, 96mm de largura (4 módulos), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SAnálise HarmônicaRegistro de dadosPedido de amostra nº.Aplicativo
M2M 10Full‑electrical measurement, Visor LCDActive 0.2S, Reactive 2Modbus RTU2DI/2DOUp to 31stBasic logging2CSG299883R4052Industrial power monitoring, energy efficiency analysis
M2M 20Power quality analysis, gravação de eventosActive 0.1S, Reactive 2Modbus RTU/TCP4D/4CUp to 40thAdvanced logging2CSG299884R4052Critical load monitoring, diagnóstico de falhas
M2M 30Advanced power quality, PQDIF exportActive 0.05S, Reactive 2Modbus RTU/TCP8D/8CUp to 63rdComprehensive logging2CSG299885R4052Centros de dados, critical production equipment
Ethernet/IP

III. M4M Series (Network Analyzers)

ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SAnálise HarmônicaRegistro de dadosAplicativo
M4M 100Full parameter measurement, análise de qualidade de energiaActive 0.02S, Reactive 1Modbus RTU/TCP16DI/16DOUp to 63rdLarge‑capacity storageMedium‑/high‑voltage distribution, grid monitoring
DNP3
M4M 200Advanced power quality, power quality reportingActive 0.01S, Reactive 1Modbus RTU/TCP24DI/24DOUp to 127thMassive storageGrid custody metering, power trading
DNP3
CEI 61850

 

  1. D1M Series (System pro M Distributed Monitoring)

ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.

ModeloFunções principaisMonitored CircuitsComunicaçãoE/SFonte de energiaAplicativo
D1M 10Centralized monitoring of 4 circuitos4×three‑phaseModbus RTU8D/4C24Em DCEdifícios comerciais, multi‑story plants
D1M 20Centralized monitoring of 8 circuitos8×three‑phaseModbus RTU/TCP16D/8C24Em DCLarge shopping malls, industrial parks
  1. EM Series (Smart Power Meters)

ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.

ModeloFunções principaisClasse de PrecisãoComunicaçãoE/SFonte de energiaAplicativo
EM 20Single‑phase current/voltage measurementAtivo 1, Reactive 2NenhumNenhumNo auxiliary powerresidencial, pequenas lojas
EM 100Single‑phase full‑electrical measurementActive 0.5S, Reactive 2Modbus opcional2DI/2DO100–230V AC/DCSmall commercial, circuitos de iluminação
EM 200Three‑phase full‑electrical measurementActive 0.5S, Reactive 2Modbus opcional4D/4C100–230V AC/DCPequenas fábricas, edifícios de escritórios
EM 400Three‑phase full‑electrical + saída analógicaActive 0.2S, Reactive 2Modbus opcional4D/4C100–230V AC/DCControle de processo, equipment interlock
2AO
  1. Other Series (Aplicações Especiais)
SérieModeloFunções principaisCenários de aplicação
IM SeriesIM302Smart power monitoring, gravação de eventosAutomação industrial, monitoramento de equipamentos
LNP3 SeriesLNP301Medição de energia, remote meter readingPublic utilities, redes inteligentes
PMU SeriesPMU6000Multifunction measurement, análise de qualidade de energiaLarge‑scale industry, energy management

VII. Guia de seleção (By Application)

  1. Basic energy metering: Choose M1M 10/12 or EM 20/100, baixo custo, meets basic statistical needs
  2. General power monitoring: Choose M1M 15/20 or M2M 10, funções completas, supports Modbus communication
  3. Power quality analysis: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
  4. Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
  5. Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-

VIII. Core Technical Parameter Comparison

SérieMeasurement AccuracyAnálise HarmônicaProtocolos de comunicaçãoI/O CapacityMontagemLargura
M1M0.5S ~ 0.2SUp to 40thModbus RTU/TCP0~2DI/2DOTrilho DIN18milímetros
M2M0.2S ~ 0.05SUp to 63rdModbus RTU/TCP

Ethernet/IP

2~8DI/DOPanel mount96milímetros
M4M0.02S ~ 0.01SUp to 127thModbus RTU/TCP

DNP3

CEI 61850

16~24DI/DOStandalone / 19″ rack19″
D1M0.5SUp to 31stModbus RTU/TCP8~16DI/DOTrilho DIN72milímetros
EM0.5S ~ Class 1Up to 15thModbus opcional0~4DI/DOTrilho DIN36milímetros

Anterior:

Próximo:

Deixe uma resposta