Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

ABB MCCB 1SDA050999R1 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

ABB MCCB 1SDA050999R1

Technical Specifications and Application Guide for ABB MCCB 1SDA050999R1 Model Explanation Model Part Description 1SDA050999R1 Unique global product code for ABB SACE Tmax T series molded case circuit breaker T2S Product series: Tmax T2 series; S stands for standard breaking capacity (50o) 160 Frame rated current: 160A TMD Trip unit type: Thermal-magnetic trip unit, D-curve ...

  • Detalhes do produto

Technical Specifications and Application Guide for ABB MCCB 1SDA050999R1

  1. Model Explanation
Model PartDescription
1SDA050999R1Unique global product code for ABB SACE Tmax T series disjuntor em caixa moldada
T2SProduct series: Tmax T2 series; S stands for standard breaking capacity (50o)
160Frame rated current: 160UM
TMDTrip unit type: Thermal-magnetic trip unit, D-curve (motor protection type)
50-500Trip unit rated current range: 50UM (rated), 500UM (instantaneous trip value)
3pNumber of poles: 3 postes
F FMounting: Fixed; Connection: Front connection
  1. Parâmetros principais

Parâmetros Elétricos

ItemValue
Rated operational voltage (Un)400V e (50/60Hz), 690V AC optional
Rated insulation voltage (interface do usuário)690V e
Rated impulse withstand voltage (Uimp)8kV
Corrente nominal (Em)50UM (adjustable range 50–500A)
Frame rated current (UTI)160UM
Capacidade de ruptura50o (415V e), 36o (690V e)
Corrente suportável de curta duração (Icw)16o (1é)
Trip curveTipo D, compatível com IEC 60947-2
Thermal trip range50–500A (adjustable)
Magnetic trip range5–10In (adjustable)
Rated frequency50/60Hz compatible

Parâmetros Mecânicos

ItemValue
Operation modeManual (padrão), motor operation optional
Mechanical endurance10,000 operações (at rated)
Electrical endurance1,000 operações (rated short-circuit breaking)
Degree of protectionIP30 (compatível com IEC 60529)
TerminalsFront connection, suitable for cable cross-section: 16–70mm²
MountingFixed, standard 35mm DIN rail mounting
  1. Mounting Dimensions
ItemValue (milímetros)
Largura90
Altura150
Profundidade105
Mounting hole pitchStandard 35mm DIN rail
Terminal spacingCompliant with IEC standards, suitable for standard cable connections
  1. Application Notes

4.1 Selection Guidelines

Suitable for motor protection and general industrial power distribution systems, especially where D-curve tripping is required

Derate when ambient temperature exceeds 40°C: 1% per °C rise; max operating temperature 60°C

Derate at altitudes above 2000m: 1% per 100m rise; max altitude 4000m

Select appropriate trip setting current according to actual load, ensuring I_load ≤ In ≤ I_cable

4.2 Requisitos de instalação

Ensure breaker is OFF and voltage-free with multimeter before installation

Mount on 35mm standard DIN rail, ensure firm fixing to avoid vibration effects

Tighten terminals with suitable torque (recommended 6N·m) to prevent overheating from poor contact

Keep sufficient heat dissipation space: at least 50mm clearance around the breaker

Avoid installation in damp, empoeirado, corrosive gas or heavy vibration environments

4.3 Operação e Manutenção

Inspect mechanical operating mechanism regularly (annually recommended) to ensure smooth ON/OFF

Test tripping function regularly (semi-annually recommended) to ensure reliable protection

Clean surface with dry soft cloth; avoid chemical cleaners

Record operation count; replace before reaching mechanical endurance

After short-circuit interruption, check breaker condition and replace if necessary

  1. Solução de problemas
Fault SymptomPossíveis causasSoluções
Fails to close1. Undervoltage trip not powered1. Check control power supply
2. Mechanical jamming2. Operate manually several times to clear jam
3. Trip unit fault3. Replace trip unit module
Tropeços frequentes1. Sobrecarga1. Check load current
2. Short circuit2. Troubleshoot short circuit
3. Improper trip setting3. Reset trip settings
4. Loose connection causing heating4. Check and tighten terminals
Contact ablation1. Long-term overload1. Replace with higher-rated breaker
2. Insufficient breaking capacity2. Upgrade to higher breaking capacity model
3. Excessive operating frequency3. Reduce operation frequency or replace suitable model
Trip unit does not operate1. Trip unit damaged1. Replace trip unit
2. Incorrect wiring2. Check wiring correctness
3. Excessively low ambient temperature3. Improve ambient temperature or select low-temperature model
Motor operation mechanism fails1. Control voltage below 85% Un1. Check control power supply
2. Limit switch not reset2. Manually reset limit switch
3. Motor fault3. Replace operating mechanism motor
  1. Brand Replacement Solutions

6.1 ABB Alternative Models

Upgrade model: XT2S 160 TMA 50–500 3p F F (1SDA067555R1), Tmax XT series, higher performance, compatible mounting dimensions

Economic alternative: Formula A1B 125 TMF 50–500 3p F F (1SDA066702R1), lower cost, same basic protection functions

6.2 Competitive Brand Equivalents

MarcaReplacement ModelMain Differences
SchneiderCVS160F TMD50 3P 50kASame breaking capacity, slight dimension difference, consistent trip curve
Siemens3VL160 50A 3P TMDSame frame current, 50kA breaking capacity, different operating mechanism design
ChintNM1-160S/3300 50ADomestic alternative, cost-effective, basic functions consistent
DeliciosoCDM1-160S/3300 50ADomestic alternative, high cost-performance, compliant with IEC standards

Detailed Mounting Dimensions for ABB MCCB 1SDA050999R1

  1. Basic Model and Mounting Type Confirmation

Full Model: ABB SACE Tmax T2S 160 TMD50–500 3p F F (1SDA050999R1)

Mounting type: Fixed (F), front connection (F)

Poloneses: 3 postes (3p)

Série: Tmax T series (not XT upgraded series)

  1. Core Mounting Dimensions (Unidade: milímetros)
ItemValueObservações
Largura (C)90Standard 3-pole width, DIN rail compatible
Altura (H)130Including operating handle, fixed standard height
Profundidade (D)70Standard depth for fixed front connection, excluding terminal extension
MountingStandard 35mm DIN railCompatível com IEC 60715, snap-in mounting
Mounting hole pitchFor 35mm DIN railRail thickness 1.0–1.5mm compatible
Terminal spacingPhase spacing 25mm, N-line spacing 25mmStandard wiring, suitable for 16–70mm² cable
Terminal height45milímetrosFrom rail plane to top of terminals
Handle height130milímetrosFrom rail plane to top of handle
Net weight1.12kgWithout packaging
  1. Detailed Dimension Diagram Description

3.1 Front View Dimensions

Total width: 90milímetros (3-pólo)

Total height: 130milímetros (including handle)

Handle travel: aprox.. 25milímetros (ON–OFF difference)

Trip indicator window: 30mm from top, centered

3.2 Side View Dimensions

Total depth: 70milímetros (fixed front connection)

DIN rail slot: 15mm from bottom, 35mm wide

Terminal connection depth: aprox.. 15mm from front surface

Terminal tightening torque: 6N·m (for M6 bolts)

3.3 Installation Clearance Requirements

LocationMin. DistanceDescription
Left and right50milímetrosFor wiring and heat dissipation
Top and bottom50milímetrosPrevent heat buildup, ensure operating space
Front operating space100milímetrosFor handle operation and maintenance
Rear (in cabinet)30milímetrosFor cable bending radius
  1. Compatibilidade de instalação

4.1 DIN Rail Compatibility

Compatible with standard 35mm DIN rail (EM 60715:2001)

Rail material: steel or aluminum, recommended thickness 1.2mm

Mounting clips: self-contained spring clips, no extra fixings needed

4.2 Dimension Comparison with XT Series

ItemTmax T2S 160 (1SDA050999R1)Tmax XT2S 160Difference
Largura90milímetros90milímetrosSame, interchangeable position
Altura130milímetros130milímetrosSame, panel cutout universal
Profundidade70milímetros82.5milímetrosXT series deeper; check cabinet space before replacement
MountingSame (35mm trilho DIN)SameFully compatible

4.3 Compatibilidade de fiação

Suitable cable cross-section: 16–70mm² (copper), crimped lugs recommended

Terminal type: plate terminals with lock washers

Connection direction: front connection, vertical or horizontal incoming

  1. Installation Cautions
  2. Confirm breaker is OFF and voltage-free before installation
  3. Ensure snap-in is fully engaged on DIN rail
  4. Tighten terminals with 6N·m torque to avoid heating
  5. Keep at least 50mm clearance between adjacent breakers
  6. Temperatura ambiente: -5°C a +40°C; derate above 40°C
  7. Technical Dimensions

Product Code: 1SDA050999R1

Mounting Type: Fixed, front connection

Poloneses: 3P

Largura: 90 milímetros

Altura: 130 milímetros

Profundidade: 70 milímetros

Mounting Rail: 35 mm trilho DIN (EM 60715)

Terminal Torque: 6 N·m

Net Weight: 1.12 kg