Advantech ADAM-5018 Analog Input Module

The ADAM-5018 is a 7-channel differential thermocouple analog input module for the ADAM-5000 rack system. It adopts RS485 Modbus RTU and is designed for temperature data acquisition, supporting multiple thermocouple types, mV voltage and current signals. Model Code Definition ADAM: Series code for Advantech remote I/O modules 50: ADAM-5000 rack backplane series (plug-in design; must ...

  • Detalhes do produto

The ADAM-5018 is a 7-channel differential thermocouple analog input module for the ADAM-5000 rack system. It adopts RS485 Modbus RTU and is designed for temperature data acquisition, supporting multiple thermocouple types, mV voltage and current signals.

  1. Definição de código de modelo

ADAM: Código de série para Advantech módulos de E/S remota

50: ADAM-5000 rack backplane series (plug-in design; must be installed on ADAM-5000 series chassis, different from standalone ADAM-4018)

18: 7-channel thermocouple & multi-function analog input

Suffix A2E/AE: Versão industrial padrão; ADAM-5018P = enhanced version with independent range per channel

Observação: Standard ADAM-5018 shares one range across all channels; the 5018P allows separate configuration for each channel.

  1. Principais especificações técnicas
  2. Canais: 7 differential input channels
  3. Resolução: 16-pedaço
  4. Total Sampling Rate: 10 S/s (all channels combined, low-speed temperature measurement)
  5. Precisão: ±0.1%FS for voltage/thermocouple mode; ±0.2%FS for current mode
  6. Isolamento: 3000 VDC optocoupler isolation to protect host and field circuits
  7. CMRR: ≥92 dB @ 50/60 Hz, strong anti-interference against power frequency noise
  8. Thermocouple Types: J., K, T, E, R, S, B

J.: 0~760°C

K: 0~1370°C

T: -100~400°C

E: 0~1000°C

R/S: 500~1750°C

B: 500~1800°C

  1. Universal Analog Signals: ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V; ±20 mA, 4~20 mA (embutido 120 Ω sampling resistor, no external resistor required)
  2. Proteção: TVS/ESD, withstand ±35 V overvoltage, proteção contra polaridade reversa
  3. Ambiente Operacional: -10 ~ +70°C, 5~95% RH sem condensação
  4. Comunicação: Backplane RS485, Protocolo Modbus RTU
  5. Fonte de energia: 10~30 VDC from rack, típico 24 CCV
  6. Hardware & Diretrizes de fiação

terminal: 16-pin pluggable screw terminal; differential wiring: thermocouple positive → CHx+, negative → CHx-

CJC Cold Junction Compensation: On-board cold-junction temperature sensor, automatic compensation, no external compensation required

Wiring Recommendation: Use matched thermocouple extension cables; route cables away from power cables to reduce EMI

Montagem: Montagem em trilho DIN, plug directly into the ADAM-5000 rack slot.

  1. Aplicações Típicas

Heat treatment furnaces, fornos, fornos, food sterilization, reatores químicos, multi-point temperature monitoring for HVAC, furnace group temperature collection; paired with PAC/PLC/SCADA host systems for temperature data logging.

  1. ADAM-5018 vs ADAM-5018P
ModeloRange Configuration
ADAM-5018Single unified range for all channels
ADAM-5018PIndependent signal type & range per channel; mixed K/J thermocouples and 4-20mA signals on one module, higher project flexibilityAdvantech
  1. Opções alternativas & Guia de seleção
  2. In-series Upgrade: ADAM-5018P (preferred for mixed sensor types)
  3. Standalone Module (No Rack Required): ADAM-4018+ / ADAM-4019+
  4. Next-Generation Bus I/O: AMAX-5018 (EtherCAT, 6-channel thermocouple, high-speed acquisition)

Aviso: AMAX-5018 belongs to EtherCAT slice I/O, not compatible with ADAM-5000 RS485 racks.

ADAM-5000 Series Full Model List

  1. Rack Backplanes (Mandatory Base Unit)

RS485 (Modbus RTU)

  1. ADAM-5000/485: 4-rack de slots
  2. ADAM-5000E: 8-rack de slots

Ethernet (Modbus TCP)

  1. ADAM-5000L/TCP: 4-slot Ethernet rack
  2. ADAM-5000/TCP: 8-slot Ethernet rack
  3. ADAM-5000/TCP-CE: 8-slot PAC rack with CE embedded system
  4. Módulos de entrada analógica (IA)
  5. ADAM-5013: 3-channel RTD (PT100/Ni100), 16-pedaço, 3000 VDC isolation
  6. ADAM-5017: 8-channel universal AI (mV/V/4~20mA), single shared range; total sampling rate 10 S/s
  7. ADAM-5017P: 8-channel AI with independent range per channel (upgraded model)
  8. ADAM-5017H: 8-channel high-speed AI, max total sampling rate 8 kHz
  9. ADAM-5017UH: 8-channel ultra-high-speed AI, max total sampling rate 200 kHz
  10. ADAM-5018: 7-channel thermocouple input (J/K/T/E/R/S/B), unified range across all channels, built-in CJC cold junction compensation
  11. ADAM-5018P: 7-channel thermocouple input with independent channel configuration; mixed TC/mA signals supported (preferred enhanced model)
  12. Módulos de saída analógica (AO)
  13. ADAM-5024: 4-channel isolated analog output; signal types: 0~10 V, 0~20 mA, 4~20 mA; 12-pedaço, 3000 VDC isolation
  14. Módulos de entrada digital (DE)
  15. ADAM-5051: 16-channel non-isolated digital input

ADAM-5051S: Sink type

ADAM-5051D: Source type

  1. ADAM-5052: 8-channel isolated DI (3000 VDC isolation)
  2. ADAM-5053S: 32-channel high-density isolated DI
  3. Módulos de saída digital (FAZER)
  4. ADAM-5050: 16-channel universal DIO, jumper-selectable DI/DO mode
  5. ADAM-5055S: 8DI+8DO mixed isolated module with LED indicators
  6. ADAM-5056: 16-channel digital output

ADAM-5056D: With LED status display

ADAM-5056S: Sink-type isolated output

ADAM-5056SO: Source-type isolated output

  1. ADAM-5057S: 32-channel high-density isolated DO
  2. Relay Output Modules (Saída de contato)
  3. ADAM-5060: 6-saída de relé de canal (2 Form A + 4 Contatos do formulário C)
  4. ADAM-5068: 8-saída de relé de canal
  5. ADAM-5069: 8-channel high-power relay output with LED indicators
  6. Contador de alta velocidade / Frequency Modules
  7. ADAM-5080: 4-channel bidirectional up/down counter, isolado, low-speed pulse input
  8. ADAM-5081: 4-channel high-speed counter & frequency measurement for high-frequency pulse acquisition
  9. Suffix Ordering Codes

EA / A2E: Versão industrial padrão (standard ordering)

SER: Wide-temperature ruggedized version

P: Enhanced model with independent channel ranges (key upgrade for 5017P & 5018P)

  1. Resumo de seleção rápida

Multi-channel thermocouple temperature acquisition: ADAM-5018 (unified range) / ADAM-5018P (independent range, recomendado)

PT100 RTD temperature measurement: ADAM-5013

Tensão & current analog acquisition: 5017 / 5017P / 5017H high-speed version

Analog control output: ADAM-5024

Digital signal input: 5051 / 5052; Digital control output: 5056; Saída de contato de relé: 5060 / 5069