Visão geral básica
- Série de marcas: Digital output module for B&R Sistema 2005 CLP de Austria B&R (modelo abreviado: DO479)
- Status do ciclo de vida: Descontinuado. Original manufacturer ceases mass production; only brand-new stock and refurbished second-hand spare parts are available on the market.
- Alternative Model Naming: 3D04796, 3DO479.6 (Carta “Ó” is often written as digit “0” in the industry)
- Código HS: 8538909100 (Electrical control assemblies)
- Especificações elétricas principais
| Item de parâmetro | Especificação Técnica |
| Channel Count | 16 transistor digital outputs with 2 electrically isolated groups (Channels 01~08 / 09~16) |
| Tipo de saída | 24 VDC Sourcing Output |
| Rated Current per Channel | 0.5 Um por ponto |
| Max Total Current per Group | 4 UM (8-channel summation limit) |
| Consumo de energia | Externo 24 CCV: 4.0 C; Backplane 5 V: 1.0 C |
| Mecanismos de Proteção | Thermal cut-off against channel short-circuit/overcurrent; Freewheeling for inductive loads; Reverse polarity protection |
| Isolamento Elétrico | Isolation between groups; Isolation between channels and PLC backplane; No isolation between channels within the same group |
| Response Delay | Hardware switching delay ≤ 1.2 EM |
| Terminal Accessories | TB170 terminal blocks to be ordered separately |
| Classe de Proteção | IP20 (For cabinet installation only) |
- Ambiental & Especificações Mecânicas
- Temperatura operacional: 0 ℃ ~ +60 ℃
- Armazenar / Temperatura de transporte: -25 ℃ ~ +70 ℃
- Umidade: 5% ~ 95% RH, sem condensação
- Dimensões: Standard single-width System 2005 módulo, Montagem em trilho DIN
- Certificações: CE, cULus (FILE E115267) industrial control equipment certifications
- Hardware & Indicadores
16 independent status LEDs on the front panel; each LED illuminates when the corresponding output channel is activated
Red locking latches on the top for snap-in connection to the System 2005 barramento de backplane
TB170 wiring terminal blocks on the right with group-split power supply: two independent 24 VDC output power loops
- Cenários típicos de aplicação
Compatível com B&Sistema R 2005 CPUs (3CPxx series) for discrete logic control on medium & small-sized machinery:
- Máquinas de embalagem: Válvulas solenóides, air cylinders, conveyor belt start/stop
- Têxtil & equipamento de impressão: Clutches, air blowing units, slitting actuators
- Injection molding auxiliary machines, woodworking machine tools, pneumatic actuators for food production lines
- Auxiliary discrete outputs for wind power and small metallurgy equipment
- Replacement Solutions for Discontinued Units
6.1 Direct Compatible Replacements within System 2005
3DO478.6: 16 FAZER, 0.3 Um por canal; low current rating, applicable only for light-load scenarios
3DO480.6: 16 FAZER, 1 Um por canal; preferred for heavy loads with no program modification required
6.2 Atualização entre séries (New X20 System, Recommended for New Projects)
X20DO9322 (16-canal 24 CCV 0.5 A sourcing output with identical functionality; backplane and CPU replacement required)
- Aquisições & Troubleshooting Guidelines
Notas de aquisição
Brand-new original units are mostly leftover inventory; abundant refurbished second-hand supplies with warranty periods ranging from 1 para 12 meses
Market price range: CNY 3,000 ~ 4,500 for new units; CNY 1,200 ~ 2,200 for refurbished units
Matriz de solução de problemas de falhas comuns
| Fenômeno de falha | Causa raiz | Resolução |
| Single channel no output, LED apagado | Loose terminal wiring / thermal fuse tripped on the channel | Power off for cooling; retighten TB170 terminals |
| Todos 8 channels in one group fail | Short-circuit on group 24 Alimentação VCC / blown internal fuse | Measure external loads for ground short-circuit |
| PLC reports I/O bus error | Unlatched module backplane latches / damaged backplane | Re-seat the module; clean bus contact pins |
| Repeated burnout of output channels | Load current exceeds 0.5 UM / no freewheeling diodes for inductive loads | Replace with higher-current modules; add parallel freewheeling protection diodes |
- Selection Restrictions
- Cannot drive AC contactors (transistor-only DC outputs without relay contacts)
- Single-channel load current strictly limited to ≤0.5 A; total load per group shall not exceed 4 UM
- Forbidden for humid, dusty or open-air environments (Apenas classificação IP20)
- Not recommended for mass deployment in new projects; X20 series is the preferred alternative
Field Application Case Sharing of B&R 3DO479.6 (3D0479.6)
Basic Module Compatibility Prerequisites
16-canal 24 VDC sourcing transistor outputs, two electrically isolated groups (Channels 0–8 / 9–16), 0.5 Um por canal, compatible with all System 2005 PCC models. Primarily designed to drive solenoid valves, indicator lamps, pequeno 24 VDC actuators, and variable frequency drive start/reset signals. Ideal for discrete logic control on standalone medium & small machines. Split-group isolation separates air supply loops and alarm loops; built-in automatic thermal short-circuit protection delivers low failure rates.
Caso 1: Automatic 3D Transparent Film Wrapping Machine (Comida & Pharmaceutical Packaging Industry)
- Equipment Architecture
Controlador: Sistema 2005 PCC Model 3CP260.60-1
Output Modules: 2 × 3DO479.6 (32 DO points total) + TB170 spring terminals
Matching DI Module: 3DI476.6 (16 entradas digitais)
Controlled Loads: 24 VDC 5/2-way solenoid valves, heat sealing heater start/stop, film cutting cylinders, conveyor alarm lamps, VFD fault reset
- Channel Allocation for Single 3DO479.6
Grupo 1 (CH01–CH08, independente 24 VDC air supply loop):
- Infeed pusher cylinder solenoid valve
- Film folding side sealing cylinder
- End sealing hot-pressing cylinder
- Film tension deviation correction solenoid valve
- Finished product discharge sorting cylinder
- Waste film cutting knife solenoid valve
- Film rack lifting cylinder
- Spare station cylinder
Grupo 2 (CH09–CH16, independente 24 VDC alarm/auxiliary supply, isolated from air supply loop):
- Equipment running green indicator lamp
- Fault red warning lamp
- Film shortage audible & visual alarm output
- Material jam shutdown indicator lamp
- VFD start signal
- VFD fault reset
- Heat sealing cooling fan start/stop
- Auto / Manual mode indicator lamp
- Core Advantages of Adopting 3DO479.6
- Two-group electrical isolation: Separates air valve loops and alarm lamp power supplies. Reverse voltage surges from inductive solenoid loads cannot damage alarm circuits. Built-in freewheeling diodes eliminate the need for external parallel diodes and reduce on-site wiring workload.
- 0.5 A per channel perfectly matches small packaging machine cylinder solenoid valves; total current limit of 4 A for each 8-channel group fully satisfies simultaneous multi-cylinder actuation load demands.
- Channel thermal short-circuit lockout: Only the faulty channel is disabled when cylinders jam or coils short-circuit; the entire machine remains operational with single-channel fault alarms for fast maintenance localization.
- High-density single-width 16-point module saves cabinet space; only two DO modules cover all logic outputs for one wrapping machine.
- On-Site Operation Results
Mass deployed across over 200 wrapping machines running continuously for 8 anos. Apenas 3 units triggered single-channel overcurrent protection with zero complete module burnout failures. Refurbished or stock 3DO479.6 spare parts are readily available on the aftermarket to cut equipment maintenance costs.
Caso 2: Automatic Pick-and-Place Robot for Injection Molding Auxiliaries (Plásticos & Home Appliance Injection Molding Industry)
- System Hardware
CPU: Sistema 2005 Model 3CP360.60-1
DO Module: 1 × 3DO479.6 (robot motion outputs)
Loads: 24 VDC clamping cylinders, blow-off solenoid valves, sprue cutting valves, safety door indicator lamps, alarm outputs, injection molding machine interlock start/stop signals
- Typical Control Workflow
Mold full open signal → 3DO479.6 outputs to lower travel cylinder → gripper clamps workpiece → blow-off valve purges sprue residue → cutting solenoid valve trims waste sprue → lifting cylinder returns to home position → discharge cylinder pushes finished product out. Fault conditions trigger warning lamps and cut interlock signals to the injection molding machine.
- Selection Rationale
All robot cylinders use low-power 24 VDC solenoid valves with coil currents of 0.2~0.4 A, below the 0.5 A rated limit. Dual isolation separates motion actuation loops and safety alarm loops, preventing safety lamp circuit damage caused by robot jamming short-circuits. Compact machine footprint allows all actuator outputs to be covered by a single 16-point module without stacking multiple low-density I/O units.
- Pain Point Resolution
Earlier non-isolated DO modules frequently suffered total alarm circuit failure when solenoid coils broke down. Group isolation on the 3DO479.6 completely eliminates cross-loop interference and cuts machine downtime failure rates by 60%.
Caso 3: Automatic Fabric Folding & Linha de produção de embalagens (Textile Printing & Dyeing Industry)
- Cenário de aplicação
Continuous line for automatic fabric flattening, folding, bagging and heat sealing post-printing/dyeing, with centralized discrete logic control over multi-section conveyors, lifting cylinders and heat seal stations.
- 3DO479.6 Channel Assignment
Grupo 1 (Transporte / Folding Cylinders): Fabric flattening roller lift, left-right edge separation cylinders, folding press plates, wrapping film pushing valves
Grupo 2 (Alarme / Auxiliary Outputs): Fabric shortage warning lamp, heat sealing heater start/stop, conveyor motor enable signal, emergency stop fault output, count completion indicator lamp
- On-Site Adaptation Features
Textile workshops feature high dust and humidity; the module’s wide 0~60 ℃ operating temperature range suits workshop environments. IP20 cabinet mounting paired with dustproof enclosures ensures stable operation. Independent per-channel LEDs enable rapid localization of jammed or disconnected cylinder points during maintenance.
Caso 4: Auxiliary Logic Control for Small Industrial Boilers (Aquecimento & Food Cooking Process Industry)
- System Architecture
B&Sistema R 2005 PCC boiler control system; analog modules handle temperature and pressure regulation, while the 3DO479.6 executes all discrete actuation outputs: Induced draft / forced draft fan start/stop signals, feedwater solenoid valves, blowdown valves, high/low water level warning lamps, overtemperature interlock shutdown outputs.
- Isolation Value Demonstration
Grupo 1: Fãs, feedwater & blowdown valves (high-power inductive loads)
Grupo 2: Alarm lamps, interlock shutdown contacts (low-voltage signal loops)
Independent isolated power supplies for the two groups block voltage spikes generated by fan contactor switching from interfering with alarm and safety interlock signals, eliminating risk of false boiler shutdowns.
Caso 5: Auxiliary Logic Control for CNC Wood Panel Cutters (Furniture Manufacturing Industry)
Controlled Loads
Panel clamping cylinders, infeed stop valves, dust extraction fan start/stop, dimension reach indicator lamps, material jam fault alarms, saw blade guard solenoid valves.
Module Advantages
Machinery requires simultaneous multi-cylinder actuation; o 4 A total current ceiling per 8-channel group supports multiple concurrent solenoid valve activations. Thermal short-circuit protection prevents total machine loss of control from coil burnout caused by jammed panels, suited for high-impact, high-dust woodworking workshop conditions.
General Selection & On-Site Maintenance Summary
- Equipment Profiles Suitable for 3DO479.6
- All outputs are small 24 VDC solenoid valves, indicator lamps, VFD start/reset signals, or small 24 VDC fans with single-point loads ≤0.5 A
- Systems requiring electrical isolation between actuation loops and alarm loops to prevent low-voltage signal interference from inductive loads
- Standalone machines with 8~32 discrete output points, compact cabinet layouts requiring high-density single-width I/O modules
- Retrofit and spare part replacement for legacy System 2005 equipment fleets
- Cenários inadequados (Selection Pitfalls to Avoid)
- Driving AC contactors or high-current DC solenoid valves (single-channel load >0.5 UM)
- Explosion-proof or open-air non-cabinet environments (Apenas classificação IP20)
- New greenfield machine designs (X20 series X20DO9322 is preferred alternative)
- Applications requiring full channel-to-channel isolation (only group isolation available; no inter-channel isolation)
- Common Retrofit & Replacement Cases
Large fleets of legacy packaging, textile and injection molding machines originally equipped with System 2005 hardware are now discontinued by OEMs. When spare modules fail, stock or refurbished 3DO479.6 units are directly installed with no program edits, plug-and-play backplane compatibility and universal TB170 terminals. Full replacement finishes within 10 minutes without wiring or software modifications.
Complete List of Discontinued B&R Modules (Original Manufacturer EOL, No Further Mass Production)
- Sistema completo 2005 Série (Fully Discontinued, Including 3DO479.6)
1.1 CPU Controllers (3CP Series)
3CP260.60-1, 3CP340.60-2, 3CP360.60-1, 3CP360.60-2, 3CP380.60-1
Auxiliary Processor: 3IF260.60-1
1.2 Entrada Digital (DE) Módulos
3DI476.6 (16 DE), 3DI486.6 (32 DE), 3DI650.6, 3DI690.6
1.3 Saída digital (FAZER) Módulos (Including 3DO479.6)
3DO478.6, 3DO479.6, 3DO480.6, 3DO486.6, 3DO650.6, 3DO690.6, 3DO750.6, 3DO760.6 (8 saídas de relé)
1.4 Combined Digital I/O Modules (DI+DO Integrated, DM Series)
3DM455.60.2, 3DM476.6, 3DM486.6
1.5 Entrada Analógica (IA) Módulos
3AI350.6, 3AI375.6, 3AI775.6, 3AI780.6, 3AT660.6 (Thermocouple module)
1.6 Saída Analógica (AO) Módulos
3AO300.6
1.7 Combined Analog I/O Modules (AI+AO Integrated, AM Series)
3AM050.6, 3AM051.6, 3AM055.6, 3AM374.6
1.8 Universal Mixed I/O Module
3UM161.6
1.9 Comunicação / Bus Interface Modules
3IF761.6, 3IF772.6, 3IF786.6, 3IF860.6
1.10 Matching Terminals (Simultaneously Discontinued)
3TB170.9 (Terminais de parafuso), 3TB170.91 (Spring terminals), 3TB178.9, 3TB178.91
- Legacy System 2003 PLC Series (Fully EOL)
Digital Output DO Modules
7DO135.70, 7DO138.70, 7DO139.70, 7DO164.70, 7DO435.7, 7DO720.7, 7DO721.7, 7DO722.7
Combined Digital DM Modules
7DM435.7, 7DM438.72, 7DM465.7
Contando / Positioning Modules
7CM211.7, 7CM411.70-1, 7MM424.70-1, 7MM432.70-1
Remote X2X I/O Modules
7XX410.50-1, 7XX412.50-1, 7XX415.50-K02, 7EX470.50-1
- 1st-Generation ACOPOS Servo Drives (Discontinued Legacy Models, Excluding ACOPOSmulti)
Full legacy single-axis drive series: 8V1016.50-2, 8V1022, 8V1044, 8AC110, 8AC120, 8AC130, 8AC140
- Legacy Power Panel HMI Touch Screens (Discontinued Operator Panels)
Early PP400 series models: 4P3040.00-490, 4PP120, 4PP150, 4PP220, 4PP250, 5PP320
- Early Discontinued X20 I/O Modules (1st-Generation X20, Superseded by New Models)
- Discontinued digital outputs: X20DO2322, X20DO4322, X20DO6321
- Legacy bus controllers: X20BC0043, X20BC0063 (Replaced by X20BC0083)
- Legacy CPUs: X20CP1483, X20CP3483, X20CP1583
- Discontinued Storage Accessories
Legacy industrial CF cards (discontinued industrial standard): 5CFCRD.0064-03, 5CFCRD.0128, 5CFCRD.0256
Master Comparison Table for Discontinued Module Replacements (Focus on System 2005 Série)
| Discontinued Model | Direct Compatible Same-Series Replacement | New X20 Upgrade Alternative |
| 3DO479.6 (16 FAZER 0.5 A sourcing output) | 3DO480.6 (16 FAZER 1 UM) | X20DO9322 |
| 3DI476.6 (16 DE) | 3DI486.6 | X20DI9371 |
| 3DM486.6 (16 DE + 16 FAZER) | No equivalent single module; combine two separate DI/DO modules | X20DM9324 |
| 3AI775.6 (8-channel 4–20 mA) | 3AI780.6 (16-bit high precision) | X20AI4622 |
| CPU 3CP360.60-1 | 3CP380.60-1 (Extremely limited stock) | X20CP3585 |
Important Remarks
- The entire System 2005 product line has been terminated by the OEM with no further firmware technical updates. Only leftover stock and refurbished second-hand spare parts circulate on the aftermarket; prohibited for new project selection.
- Repair policy for discontinued modules: OEM no longer provides component-level repair; full module replacement is the only option, and service availability declines year over year.
- Compatibility limitations: Sistema 2003 / 2005 backplanes cannot directly interface with X20 bus systems. Full machine upgrades require complete replacement of backplane, CPU and all I/O modules plus partial communication program rework.
- Your primary module 3D0479.6 = 3DO479.6 is a standard discontinued DO module within the System 2005 lineup; refurbished units constitute the main spare part supply source for maintenance operations.
Notas de Tradução
- Industry-standard automation terminology adopted (sourcing output, Trilho DIN, backplane, interlock, diodo de roda livre, EOL = End of Life, Código HS)
- Model numbers, certification file numbers and mechanical parameters remain unchanged as original technical data
- Unit currency CNY retained for price references; technical metric units kept consistent
- Table formats, heading hierarchy and section segmentation match the original Chinese document for direct use in international technical documents, catalogs and tender files
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares



















NH42-63-318x560.png)