Relé de estado sólido monofásico OMRON G3PA-240B-VD

Omron single-phase SSR, integrated heat sink, Montagem em trilho DIN, zero-crossing type ✅ Model Code Explanation G3PA: G3PA series solid state relay with integrated heat sink 2: Output voltage class AC24~240V 40: Rated output current 40A B: Built-in heat sink, screw terminals VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light 📋 Key Specifications ...

  • Detalhes do produto

Omron single-phase SSR, integrated heat sink, Montagem em trilho DIN, zero-crossing type

✅ Explicação do código do modelo

G3PA: G3PA series solid state relay com dissipador de calor integrado

2: Output voltage class AC24~240V

40: Rated output current 40A

B: Built-in heat sink, terminais de parafuso

VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light

📋 Key Specifications

Lado de entrada (Terminais de Controle A1/A2)

Tensão de entrada nominal: DC 5~24V

Faixa de tensão operacional: DC 4~30V

Máx.. input current: 7mA (25℃)

Tensão de captação: ≤DC4V; Tensão de saída: ≥DC1V

Lado de saída (Terminais de Carga)

Load voltage: AC24~240V, permissible range AC19~264V (50/60Hz)

Corrente nominal: 40A @40℃; derate to 36A when tightly mounted side by side

Surge current withstand: 440UM (60Hz, 1 ciclo)

On-state voltage drop: ≤1.6V RMS

Leakage current: ≤20mA@AC200V

Trigger mode: Zero-cross switching (ideal para aquecer cargas para reduzir interferências)

Isolamento: Fototriaco

Operar / hora de lançamento: ≤ meio ciclo +1ms

Ambiental & Mecânico

Montagem: Trilho DIN / montagem com parafuso

Temperatura ambiente: -30~+80℃ (sem condensação ou gelo)

Rigidez dielétrica: AC4000V 1min; resistência de isolamento ≥100MΩ (CC500V)

Terminais: Terminais de parafuso

Certificações: UL, cUL, VDE, CE

📌 Aplicações Típicas

Tubos de aquecimento elétrico, fornos industriais, aquecimento de moldagem por injeção, equipamento de ar quente, Controle de temperatura ON/OFF para cargas resistivas monofásicas. Não é adequado para PWM de alta frequência, apenas para comutação periódica de cruzamento de zero.

⚠️ Notas importantes

  1. Use classificação de 40A para cargas resistivas; cargas indutivas (motores, transformadores) exigem desclassificação pesada.
  2. Quando várias unidades estão firmemente instaladas lado a lado, reduzir a corrente para 36A devido à má dissipação de calor.
  3. Tipo de cruzamento zero: liga e desliga somente quando a tensão CA cruza zero. Ele suprime EMI, mas não pode alternar em ângulos de fase aleatórios.
  4. Entrada DC não polarizada; pode ser acionado diretamente por PLC ou controlador de temperatura com saída DC5–24V.
  5. O SSR não possui contatos mecânicos e não pode fornecer proteção contra curto-circuito. A fuse must be installed upstream.

🔁 Same Series & Modelos Alternativos

G3PA-220B-VD: 20UM / AC24-240V / DC5-24V

CEO do G3PA-260B: 60UM / AC24-240V / DC5-24V

G3PA-420B-VD: 20UM / AC200-400V / DC12-24V

Alternativas domésticas: 40A zero-cross SSR with integrated heat sink. Verify derating curve and surge rating before replacement.

CEO do G3PA-240B (Zero-crossing, 40UM, DC5–24V Controlled SSR) Cenários de aplicação

Posicionamento central: ON/OFF temperature control for single-phase AC24–240V resistive loads. DIN rail integrated heat sink, driven by temperature controllers or PLCs. Designed mainly for heating loads, zero-crossing for low EMI, capable of frequent switching. Not for high-frequency PWM or inductive loads such as motors.

🔥 Heating & Controle de temperatura (Uso primário)

  1. Fornos industriais, hot air circulation ovens, aging chambers, constant temperature cabinets, high-low temperature test chambers (electric heating tubes, quartz heating tubes)
  2. Injection molding barrel heating, extruder die heating, blow molding machine zone heating
  3. Hot press machines, hot stamping machines, heat transfer machines, placas de aquecimento para laminadores
  4. Máquinas de embalagem: seladores térmicos, facas de corte a quente, aquecimento de túnel retrátil
  5. Maquinaria alimentar: linhas de cozimento, secadores de ar quente, aquecimento elétrico para cozinhar molho, fornos comerciais
  6. Tratamento de água: caldeiras de aquecimento elétrico, aquecimento do tanque, aquecimento de traços de tubulação, descongelar aquecimento
  7. Máquinas de vulcanização, circuitos de aquecimento monofásicos para controladores de temperatura de moldes. (Para aquecimento trifásico, usar 3 unidades separadamente para cada fase.)

🧪 Equipamentos de automação

  1. Câmaras de testes ambientais, temperatura constante & máquinas de umidade, seções de aquecimento elétrico de desumidificadores
  2. Semicondutor / Produção de PCB: linhas de secagem, estações de pré-aquecimento para revestimento com cola
  3. Equipamento de bateria de lítio: fornos a vácuo, aquecimento de gabinete de formação
  4. Impressão têxtil & tingimento: configurar máquinas, salas de secagem, aquecimento de rolo quente
  5. Máquinas de impressão: túneis de secagem, aquecimento auxiliar para sistemas UV

💡 Outras comutação de carga resistiva

  1. Lâmpadas halógenas de alta potência, bancos de lâmpadas de aquecimento infravermelho (cargas de lâmpadas resistivas)
  2. Aquecedores elétricos de alta potência para armários e salas limpas
  3. Módulos de aquecimento auxiliar elétrico para ar condicionado / sistemas de ar fresco

Vantagem: A comutação zero-cross reduz a corrente de partida e a interferência nos instrumentos de temperatura, PLCs e rede elétrica.

✅ Condições de trabalho adequadas

Troca frequente (várias a dezenas de vezes por minuto), evite desgaste de contato e arco voltaico dos contatores

Acionado por controladores de temperatura PID ou saídas digitais PLC (CC24V)

Instalação em trilho DIN dentro de gabinetes de controle, espaço compacto, dissipador de calor embutido, não é necessário dissipador de calor extra

Alto isolamento (4Rigidez dielétrica kV) e indicador de operação para fácil comissionamento

Cargas de aquecimento resistivas monofásicas, principalmente AC220V, corrente ≤40A (desclassificar para 36A quando montado densamente)

❌ Aplicativos não recomendados (Armadilhas de seleção)

Motores CA, bombas de água, transformadores e outras cargas indutivas: alta oscilação de partida pode causar quebra. Desclassificação pesada ou SSR de fase aleatória / contator é preferido.

Escurecimento PWM de alta frequência (dezenas de Hz ou acima): SSR cruzado zero não pode realizar a regulação do ângulo de fase.

Cargas capacitivas.

Guia de seleção OMRON G3PA-240B-VD & Notas de aplicação (Versão da página do produto, chinês + Inglês)

Otimizado para o site de comércio exterior bestcontactor, legível para engenheiros, compradores e aquisições, Compatível com EAT.

  1. Lista de verificação de seleção - confirme o 4 Itens antes de escolher G3PA-240B-VD

✅ Tipo de carga: Carga resistiva monofásica preferida (tubos de aquecimento, aquecedores infravermelhos, placas de aquecimento)

✅ Tensão de carga: CA 24~240V (AC220V mais comum)

✅ Sinal de controle: DC 5~24V (CLP FAZER, Saída do controlador de temperatura PID)

✅ Montagem: Trilho DIN dentro do gabinete, integrated heat sink

Se não estiver satisfeito – Alternativas recomendadas

  1. Cargas indutivas (motores, válvulas solenóides, transformadores)

Não recomendado para este modelo. Use contatores ou SSR de fase aleatória com pelo menos 50% desclassificação atual.

  1. 3-cargas de aquecimento de fase

Solução: 3 pcs G3PA-240B-VD para controlar cada fase de forma independente. Não use uma unidade para carga trifásica.

  1. Regulação de energia, escurecimento de ângulo de fase, PWM de alta frequência

G3PA é SSR cruzado zero, apenas para controle do ciclo ON/OFF, não modulação de ângulo de fase. Choose OMRON G3PW power controllers if regulation is needed.

  1. Load current near 40A continuously, multiple units tightly arranged

Derate to 36A for dense mounting. Upgrade to G3PA-260B-VD (60UM) if load current is continuously above 36A.

Load Current Formula (for foreign trade page)

Safe current for resistive load = rated load current × 1.25 margem de segurança

Multiply by 0.9 derating factor if densely mounted

Exemplo: 3000W @AC220V heating tube, current ≈13.6A, sufficient margin for G3PA-240B-VD.

  1. Guia de fiação (Concise for Product Page)

Entrada (controlar): A1, A2, DC5~24V, não polarizado

Saída (carregar): power in, carregar; AC side non-polarized

Built-in operation indicator: lights up when control signal is present for easy on-site commissioning

Isolation rating: AC4000V between input and output

Importante: Fast fuse must be installed on upstream AC side. SSR cannot withstand short circuit and will be permanently damaged.

  1. Notas de aplicação
  2. Dissipação de Calor & Desclassificação

This model has integrated heat sink. A dissipação de calor piora em altas temperaturas do gabinete ou quando montado firmemente lado a lado; classificado como 40A desclassifica para 36A. Mantenha a ventilação dentro do gabinete. A instalação selada sem fluxo de ar é proibida.

  1. Característica de cruzamento zero

O SSR liga e desliga somente quando a tensão CA cruza zero. Benefícios: baixa corrente de partida e baixo EMI. Limitação: não é possível mudar em ângulo de fase arbitrário, não para dimerização ou controle de fase.

  1. Corrente de fuga

Corrente de fuga residual pequena (≤20mA @AC200V) existe no estado OFF. Cargas pequenas podem apresentar leve aquecimento ou brilho, o que é normal para SSR. Um resistor de sangria pode ser adicionado para resolver isso.

  1. Surto de carga

Lâmpadas infravermelhas e tubos de quartzo têm baixa resistência ao frio com alta corrente de partida ao serem ligados. Este modelo suporta 440A (60Hz, 1 ciclo). Selecione uma classificação de corrente mais alta se o pico exceder esse valor.

  1. Condições ambientais

Temperatura operacional: -30℃ ~ +80 ℃, sem gás corrosivo, condensação ou acúmulo de poeira. Poeira e óleo obstruirão o dissipador de calor e acelerarão o envelhecimento.

  1. Operações Proibidas

Não teste curto-circuito de saída; não use diretamente para cargas capacitivas; evite cargas indutivas de aumento frequente.

  1. Itens de suporte recomendados

Fusível: fusível rápido cerâmico

Controlador de temperatura: OMRON E5CC / Controlador PID E5EC

Modelos alternativos: G3PA-220B-VD (20UM), CEO do G3PA-260B (60UM)

Atualização para regulação de energia: Controlador de potência da série G3PW

  1. Perguntas frequentes (para parte inferior da página do produto)

P: Pode controlar motores G3PA-240B-VD?

UM: Não recomendado. O SSR cruzado zero tem resistência limitada a surtos e pode falhar sob a corrente de partida do motor. Contator CA é preferido.

P: Por que o tubo de aquecimento ainda está ligeiramente quente depois que o SSR é desligado?

UM: É causado pela corrente de fuga inerente do SSR, mais óbvio em cargas pequenas. Adicione um resistor de sangria.

P: Pode ser acionado diretamente pela saída PLC DC24V?

UM: Sim. O consumo de energia de entrada é baixo (aprox.. 7mA), pontos de saída padrão do PLC podem conduzi-lo.

Série completa de relé de estado sólido SSR OMRON (Foreign Trade Selection Version, Classified, including G3PA)

Classificação: Integrated heat sink DIN rail type (first choice for cabinet heating), separate heat sink type, fault detection SSR, plug-in I/O miniature SSR, power controller (not regular SSR, often selected together), discontinued models marked.

  1. Integrated Heat Sink DIN Rail SSR (Most Common for Heating, including G3PA)
  2. G3PA (Slim integrated type, replaceable power module)

Monofásico, CA24–240V / AC200–480V, DC5–24V control, zero-crossing

G3PA-210B-VD: 10UM

G3PA-220B-VD: 20UM

CEO do G3PA-240B: 40UM (este modelo)

CEO do G3PA-260B: 60UM

G3PA-420B-VD: 20UM, AC480V version

G3PA-430B-VD: 30UM, AC480V version

G3PA-450B-VD-2: 50UM, AC480V version

✅ Typical use: fornos, aquecimento de moldagem por injeção, mold temperature machines, PID ON/OFF temperature control

  1. G3PE (New compact integrated type, monofásico & 3-fase)

Monofásico: G3PE-215B / 225B / 235B / 245B; 3-phase G3PE-325B, G3PE-345B

Vantagens: better surge tolerance, random-phase version available, suitable for some inductive loads and dimming

Montagem: Trilho DIN, monofásico / 3-phase heating circuits

  1. G3PJ (Low heat dense mounting type, 25A rating remains valid even 3 units tightly side by side)

G3PJ-225B, G3PJ-225B-PU (Terminal de mola push-in)

For high-density control cabinets with multi-zone heating

  1. G3PH (High-current integrated type)

75UM / 150UM, AC240V, AC480V, for heavy heating loads

  1. G3PC (SSR with built-in fault detection)

Heater break detection and SSR short-circuit alarm output. Safety-critical heating control, preferred for test chambers and lithium battery ovens.

  1. G3PF (Smart CT current sensing SSR)

Built-in current transformer for real-time heating element break and short-circuit detection. For high-end equipment with alarm logging.

  1. Separate Heat Sink Type (No built-in heat sink, embedded installation, external heat sink required)
  2. G3NA (Classic universal model, large market stock)

Monofásico, 5A~90A, mainly zero-crossing

G3NA-205B / 210B / 220B / 240B / 260B

G3NA-410B / 420B / 440B / 460B (AC480V)

G3NA-290B (90Uma alta corrente)

Sufixo: -VD = DC5–24V control; models without B are random-phase type

  1. G3NE (Economical low-current, 5A/10A/20A, quick connect terminals)

Baixo custo, small heating loads, lâmpadas infravermelhas, embedded inside machines

  1. Plug-in / I/O Mini SSR (Mesma área ocupada pelos relés MY/LY, sinal e comutação de carga pequena)

G3F / G3FD: Tamanho do meu relé, montagem em soquete, pequenas cargas CA/CC

G3H / G3HD: Tamanho do relé de potência LY

G3R-E/S: SSR de isolamento de E/S de pegada G2R

G3RV-ST: 6.2mm fino trilho DIN E/S SSR, saída de isolamento PLC de alta densidade

G3TA: SSR compatível com blocos terminais de E/S G7TC

G3RZ: Tipo MOSFET, Cargas de baixa potência CA/CC

  1. Controladores de energia (Reguladores de energia, SSR ON/OFF não regular)

Controle de ângulo de fase, controle de ciclo, início suave, para regulação contínua de potência

G3PW: Controlador de potência monofásico (amplamente utilizado para regulação em vez de SSR)

G3ZA: Controlador de potência multicanal

G32A-EA: Unidade de controle de ciclo

  1. Montagem em PCB SSR (Soldado em PCB, comutação de sinal)

G3S, G3M, G3DZ, G3TB etc.. Corrente baixa, isolamento de sinal, usado dentro de placas de controle

  1. Modelos descontinuados (Perguntas frequentes em consultas de comércio exterior)

G3PB, G3NH, G3B/G3BD, antigo G3RV-SR. Não recomendado para novos designs; apenas para substituição de reposição.

✅ Tabela de Seleção Rápida (Can be placed directly on product page)

SérieHeat Sink TypeFaixa AtualPrincipais recursosAplicações Típicas
G3PAIntegrated DIN rail10~60AMagro, zero-crossing, replaceable power coreMoldagem por injeção, fornos, general heating
G3PEIntegrated DIN railSolteiro / 3-phase 15~45ABetter surge resistance, random-phase optionAquecimento, partial inductive loads
G3PJIntegrated DIN rail25UMNo derating when densely mountedMulti-zone dense control cabinets
G3PHIntegrated DIN rail75/150UMExtra high currentHigh-power heating
G3PC / G3PFIntegrated DIN rail25~45AFault detection & alarmeLithium battery ovens, aging chambers, safety-critical equipment
G3NASeparate heat sink5~90AUniversal, econômicoEmbedded inside machines, external heat sink required
G3NESeparate heat sink5~20AEconômicoLow-power heating
G3PWPower regulator–Fase / cycle power controlContinuous temperature regulation

📌 Suffix Meaning (FAQ for Foreign Trade)

VD: DC5~24V non-polarized DC input (G3PA-240B-VD uses this suffix)

B: Zero-crossing trigger

No B: Random-phase trigger (phase-angle switching, adequado para cargas indutivas)

PU: Terminal de mola push-in

-2: 480Versão V