Finder 7S.14.9.024.0220 Forced Guided Contact Safety Relay Module Model Code Interpretation Segment Code Meaning Series Code 7S Finder 7S series forced guided contact safety relay module, compatível com EN 50205:2002 Type A Contact Configuration 14 4-pólo, 2 Normalmente aberto + 2 Normally Closed contacts Mounting & terminal 9 Montagem em trilho DIN, cage-clamp terminal, 22.5mm largura ...

  • Detalhes do produto

Módulo de relé de segurança de contato guiado forçado Finder 7S.14.9.024.0220

  1. Interpretação de código modelo
SegmentoCódigoSignificado
Código da série7SFinder 7S series forced guided contact safety relay module, compatível com EN 50205:2002 Tipo A
Configuração de contato144-pólo, 2 Normalmente aberto + 2 Contatos normalmente fechados
Montagem & terminal9Montagem em trilho DIN, cage-clamp terminal, 22.5mm largura
Tensão da bobina2424Bobina de controle V CC
Versão & Recurso220Standard version without extra functions
  1. Tabela de especificações principais
CategoriaParâmetroObservações
Informações básicas
FabricanteFinderFamous Italian relay brand
Tipo de produtoForced guided contact safety relay moduleNon-latching type
Número do pedido7S.14.9.024.0220 / 7S1490240220Two formats are both applicable
Parâmetros Elétricos
Tensão da bobina24Em DCStandard industrial control voltage
Consumo de energia da bobina1.2CTypical value
Contact Arrangement2NÃO+2NC (4P)Forced guided design for synchronous contact operation
Corrente nominal6A @ 250 Vca (AC-1)Rated value for different load types
6A @ 30V DC (DC-1)
3A @ 230V AC (AC-15)
Material de contatoAgNi Silver Nickel AlloyHigh conductivity and wear resistance
Mecânico & Parâmetros Ambientais
Tipo de instalaçãoTrilho DIN (EM 60715)22.5mm compact width
Tipo de terminalCage-clampScrewless wiring, fácil instalação
Grau de proteçãoIP20Finger-proof, suitable for cabinet interior
Temperatura operacional-40°C ~ +70°CWide temperature range for industrial use
Temperatura de armazenamento-40°C ~ +85°C
CertificaçãoEM 50205:2002 Tipo A, EM 13849-1International safety relay standards
Vida útilMecânico: 10⁷ operations
Elétrica: 10⁵ operations at rated load
  1. Referência de substituição entre marcas
MarcaModeloSemelhançasDiferenças
CogumeloPNOZ X2.8P 24VDC2NÃO+2NC, 24CCV, forced guided contactProfessional safety relay, higher price and richer functions
Siemens3TK2825-1BB402NÃO+2NC, 24CCV, Montagem em trilho DINBetter compatibility in industrial automation
SchneiderZelio SR2B121BD2NÃO+2NC, 24CCV, forced guided contactDifferent terminal design, econômico
OmronG9SA-321-T0752NÃO+2NC, 24CCV, safety certifiedTamanho compacto, ideal for limited space
  1. 7S Series Main Model List
ModeloContact LayoutTensão da bobinaTipo de terminalRecurso Especial
7S.12.9.024.02202P (1NÃO+1NC)24Em DCCage-clampPadrão
7S.14.9.024.02204P (2NÃO+2NC)24Em DCCage-clampPadrão (this product)
7S.16.9.024.02206P (3NÃO+3NC)24Em DCCage-clampPadrão
7S.14.9.230.02204P (2NÃO+2NC)230V eCage-clampPadrão
7S.14.9.024.42204P (2NÃO+2NC)24Em DCCage-clampLED status indicator
7S.14.9.024.52204P (2NÃO+2NC)24Em DCTerminal de parafusoPadrão
7S.34.9.024.02204P (2NÃO+2NC)24Em DCCage-clamp10Uma corrente nominal
  1. Solução de problemas & Maintenance Guide

5.1 Common Fault Analysis

Fenômeno de falhaPossíveis causasInspection Steps
Coil fails to pull in1. Insufficient or reversed coil voltage1. Measure coil voltage to confirm 24V DC
2. Bobina queimada2. Test coil resistance (normal: approx 480Ω)
3. Fiação solta3. Check terminal tightness
No contact movement1. Jammed forced guided mechanism1. Check mechanical flexibility after power off
2. Oxidized or burnt contacts2. Inspect contact surface damage
3. Mechanical wear3. Verify contact travel distance
Colagem de contato1. Arc burn caused by overload or short circuit1. Check actual load exceeding rating
2. Contact material fatigue2. Replace relay module
LED indicator off1. Damaged LED1. Check power supply connection
2. Power disconnection2. Replace with identical module for test
3. Internal circuit failure

5.2 Manutenção & Replacement Suggestion

  1. Safety Priority: Cut off power and wait at least 5 minutes for capacitor discharge before maintenance.
  2. Estrutura Modular: On-site repair is not recommended; integral replacement is preferred.
  3. Replacement Procedure

Record wiring positions by photos or sketches

Remove old module from DIN rail

Install new module and reconnect wires accordingly

Power on and verify normal operation

  1. Manutenção preventiva

Inspect terminal connection every 6 meses

Avoid overload, reserva 30% current margin

Shorten replacement cycle to 2-3 years under harsh conditions

  1. Cenários de aplicação & Casos da Indústria

6.1 Applicable Fields

IndústriaAplicação TípicaFunção de segurança
Machinery ManufacturingEmergency stop circuit, safety door monitoringPrevent accidental startup, protect operators
Automatic Production LineSafety light curtain, two-hand control circuitSecure operating area safety
Elevator & EscalatorDoor lock monitoring, safety loopAvoid unexpected elevator movement
Trânsito FerroviárioDoor control, braking systemComply with railway safety standards
Máquinas de embalagemGuardrail monitoring, parada de emergênciaPersonnel injury prevention

6.2 Inadmissible Working Conditions

High vibration environment such as stamping machines, shockproof bracket required

Humid and dusty environment, IP54+ sealed enclosure needed

Ultra-high frequent switching over 10 cycles per minute, solid state relay recommended

High current load over 6A / 250V e, contactor required for capacity expansion

6.3 Dicas de seleção & Avoidance Notes

  1. Distinguish forced guided contact from ordinary relay; EM 50205 compliant type mandatory for safety application
  2. Confirme a tensão da bobina, avoid AC and DC confusion; this model is 24V DC
  3. Match load type with corresponding rated current (AC-1/AC-15/DC-1)
  4. Reserve enough installation space for 22.5mm width module
  5. Ensure compliance with EN 13849-1 for industrial safety usage

Application Scenarios of Finder 7S.14.9.024.0220

Equipped with forced guided safety contacts, conforming to EN13849 and EN50205 safety standards, applied for equipment safety loop control.

  1. General Industrial Machinery
  2. Máquinas-ferramentas: Emergency stop circuit, safety door interlock, tool magazine safety lock
  3. Stamping & forging machines: Guard fence detection, slide safety limit
  4. Máquinas de moldagem por injeção: Mold safety door, manipulator area protection interlock
  5. Automatic Production Line
  6. Linha transportadora: Light curtain safety protection, station access judgment
  7. Assembly equipment: Two-hand startup circuit, robot fence access control
  8. Sorting & máquinas de embalagem: Flip cover protection, fault emergency stop interlock
  9. Lifting & Hoisting Equipment
  10. Small lift, cargo elevator door control safety circuit
  11. Crane lifting tool limit protection, power-off safety lock
  12. Indústria Leve & Special Machinery
  13. Safety stop interlock for printing and textile machinery
  14. Safety door monitoring for wood cutting equipment
  15. Fault power-off protection for fans and water pumps
  16. Transporte & Building Auxiliary
  17. Automatic door and escalator safety detection circuit
  18. Vehicle industrial control, miniature railway equipment safety protection
  19. Control Cabinet Internal Control
  20. System emergency power-off safety loop
  21. High voltage cabinet access control and leakage safety interlock

Unsuitable Environments

Non-sealed cabinet with strong corrosion and heavy dust

Ultra-high frequency switching working condition

Working current exceeding 6A rated load

Anterior: