Fluke 572-2 High Temperature Infrared Thermometer

Posicionamento do produto: Industrial handheld infrared thermometer combining infrared and K-type thermocouple. Designed for long-distance high-temperature measurement, widely used in power, metalurgia, cement and petrochemical industries. Key Specifications Infrared Temperature Range: -30 ℃ ~ 900 ℃ Distance-to-Spot Ratio (D:S): 60:1 (90% energia), minimum spot diameter φ19 mm, dual-laser targeting Infrared Accuracy (at 23℃ ambient): ≥0℃: ±1℃ ...

  • Detalhes do produto

Posicionamento do produto: Industrial handheld infrared thermometer combining infrared and K-type thermocouple. Designed for long-distance high-temperature measurement, widely used in power, metalurgia, cement and petrochemical industries.

Especificações principais

Infrared Temperature Range: -30 ℃ ~ 900 ℃

Distance-to-Spot Ratio (D:S): 60:1 (90% energia), minimum spot diameter φ19 mm, dual-laser targeting

Infrared Accuracy (at 23℃ ambient):

≥0℃: ±1℃ or ±1% of reading, whichever is greater

-10 ~ 0℃: ±2℃

<-10℃: ±3℃

K-type thermocouple input (contact temperature measurement): -270 ℃ ~ 1372 ℃

Emissivity: 0.10 ~ 1.00 ajustável (0.01 step), built-in material emissivity lookup table

Tempo de resposta: <500EM (95%)

Spectral Band: 8~14 μm

Data Storage: Até 99 registros, USB export supported

Mostrar: MAX/MIN/AVG/DIF, high/low temperature audible & alarme visual, adjustable backlight

Fonte de energia: 2×AA batteries; Peso líquido: 322g

Principais recursos

  1. Dual-Laser Targeting: Offset dual lasers mark the measurement area for precise targeting of small objects from long distances
  2. Dual Measurement Mode: Non-contact infrared + K-type thermocouple contact measurement, balancing operational safety and accuracy verification
  3. Industrial Robustness: Ergonomic anti-slip housing, intuitive menu, suporte multilíngue
  4. Função de alarme: Audible and visual alert on temperature threshold violation, suitable for inspection and predictive maintenance of equipment

Aplicações Típicas

Indústria de energia: Switchgear, barramentos, transformadores, cable joints temperature inspection

Metalurgia / Heat treatment: Furnace body, rolls, casting surface temperature

Cimento, vidro, petroquímico: Kiln, pipeline, reactor surface temperature measurement

Machinery industry: Motor, bearing and high-temperature equipment inspection

Conteúdo do pacote padrão

Fluke 572-2 Unidade Principal

K-type bead thermocouple probe

USB cable

2 AA batteries

User manual and certificate of conformity

Comparison with Related Models

Fluke 572-2: 60:1 razão, max infrared temp 900℃, with K-type thermocouple and data storage

Fluke 568: 50:1 razão, max infrared temp 800℃

Fluke 62 MAX+: 12:1 razão, max temp 650℃, entry-level industrial model

Seleção & Notas de Operação

  1. D:S=60:1: The spot size increases with measurement distance; shorten distance when measuring small targets
  2. Polished metallic surfaces have low emissivity and may cause large measurement error. High-temperature tape is recommended to raise emissivity
  3. Infrared measures surface temperature only; K-type thermocouple is used for contact temperature comparison
  4. Not suitable for measurement through glass or transparent plastics (infrared radiation will be blocked)

Fluke 572-2 Troubleshooting Checklist

Recommended troubleshooting sequence: Power supply → Lens / Optical path → Parameter setting → Ambient condition → Hardware / Error code; Do NOT disassemble the unit. Disassembly of internal laser and sensor will void calibration and warranty.

  1. Power Supply Faults
SintomaCausa raizRemédio
Blank screen, no response when trigger is pulledModo de suspensão / Bateria descarregada / Polaridade reversa1. Pull trigger to wake up; 2. Replace with new AA alkaline batteries, verify polarity; 3. Inspect battery contacts for oxidation or electrolyte corrosion
Low battery icon displayed, unstable readingsInsufficient battery voltageReplace batteries immediately; Accuracy is unreliable under low power, discontinue inspection
Emissivity, time and stored data lost after battery replacementBattery removal exceeds 1 min, mainboard power resetReplace battery promptly upon low power alert; Complete battery swap within 1 minuto; Reconfigure parameters afterwards
  1. Mostrar & Error Codes
SintomaCausa raizRemédio
shown on screenTarget temperature out of range (<-30℃ or>900℃)Confirm target temperature is within measuring range; Infrared max 900℃, K-type thermocouple max 1372℃
EEPROMErr / CalAreaErr / ProbCalErDamaged internal storage / calibration dataNo on-site repair possible. Stop operation and send to Fluke authorized service center
Alarm light flashes with buzzer soundAlto / low temperature alarm triggeredEnter menu to check threshold, modify or disable alarm as required

III. Laser Targeting Faults

SintomaCausa raizRemédio
Valid infrared reading but dual laser does not turn onLow battery; Ambient temp>40℃; Laser disabled in menu1. Substitua a bateria; 2. Move to location with ambient temp ≤40℃; 3. Enable laser in menu
Blurred or offset laser spotDirty or scratched lensLente limpa; Replace lens assembly if scratched
  1. Inaccurate / Drifting Readings (Most Common Fault)

Distinguish first: Infrared reading error VS K-type thermocouple probe error

Inaccurate Infrared Readings

  1. Wrong emissivity setting: Polished metal has low emissivity leading to high reading; Non-metal has high emissivity. Adjust emissivity from 0.10~1.00; Apply high-temperature tape for shiny metal (emissivity≈0.95)
  2. Field-of-view spot issue: D:S=60:1. Too long distance results in spot larger than workpiece and captures surrounding hot/cold objects. Shorten distance and ensure full spot coverage on target surface
  3. Contaminação de lentes: Pó, óleo, moisture attenuate infrared signal

✅ Cleaning procedure: Blow with compressed air → Brush gently with camel hair brush → Wipe with cotton swab moistened with pure water; Do NOT use alcohol, acetone or other solvents, which will damage infrared lens

  1. Ambient interference: Hot air stream, vapor, smoke, vidro / transparent plastic blocking optical path; forte interferência eletromagnética (welding machine, aquecimento por indução); water film or oxide scale on target surface
  2. Thermal shock: Sensor unstable when moved from drastically different temperature environment. Let instrument stabilize ≥30 minutes on site before measurement
  3. Reflected heat from surrounding hot sources causes falsely high reading: Adjust measurement angle to avoid hot background reflection

No Reading / Abnormal Reading on K-type Thermocouple Channel

  1. Loose or oxidized probe connector; fio quebrado

✅ Remedy: Re-seat connector; Cross-test with 80PK series K-type probe to identify fault on probe or instrument jack

  1. Wrong thermocouple type selected: Unit only accepts K-type. S/T/J type probes cannot read correctly
  2. Cold junction compensation anomaly: Large temperature difference at probe terminal
  3. USB Communication & Data Export Faults
SintomaCausa raizRemédio
PC fails to recognize instrument and export recordsInstrument not powered on; FlukeView Forms software not running; Damaged USB cable1. Hold trigger to keep unit powered; 2. Launch FlukeView Forms software; 3. Replace USB cable for test; 4. Check PC USB port
Stored data lostBattery depleted for long time; Battery replacement timeoutExport records regularly; Replace battery at low power prompt
  1. Mecânico & Appearance Faults
  2. Sticky trigger: Dust accumulated in trigger gap, clean with dry brush, Do NOT apply lubricant
  3. Carcaça rachada: Damage from drop impact. Crack does not affect temperature reading but reduces ingress protection, keep away from moisture
  4. Lens scratch: Scratch introduces measurement error, return to factory for lens replacement and recalibration

VII. Julgamento de falha & Service Standard (When to Stop Using)

✅ On-site repairable: Battery replacement, lens cleaning, parameter reset, probe cross-verification

❌ Must send to official service, no disassembly allowed:

  1. EEPROM or calibration related error codes
  2. Cracked lens, internal water condensation
  3. Persistent reading deviation after drop impact, cannot be corrected by lens / emissivity adjustment
  4. Battery leakage corroding mainboard contacts

VIII. Quick On-Site Self-Check Procedure

  1. Install new batteries and stabilize for 30 min under ambient condition
  2. Lente limpa, restore factory menu setting, set emissivity to 0.95
  3. Measure warm water (aprox.. 80~90℃) in infrared mode, connect K-type thermocouple for contact comparison; Deviation shall stay within specified accuracy
  4. Verify laser, high/low alarm, backlight and trigger hold function
  5. Test USB connection and data read/write

Fluke 570 Série (572 Family) Lista de modelos

Consists of Legacy 570 série (Descontinuado) and Currently available 572-2. Fluke 570 series is industrial high-precision long-distance infrared thermometer with K-type thermocouple input.

  1. Legado 570 Série (Descontinuado, available in spare / second-hand market)
ModeloConfiguração de chavePrincipais diferenças
Fluke 572 (legado, no -2 sufixo)-30~900℃, D:S=60:1, 3-point laser targeting, K-type thermocouple input, RS232 interfaceOld version with serial port, no USB, descontinuado
Fluke 574-30~900℃, D:S=60:1, 3-point laser, RS232, registro de dados, optional close-focus 50:1 pequena manchaEnhanced data logging vs 572; 574-NI: version without infrared calibration certificate
Fluke 576-30~900℃, D:S=60:1, built-in digital camera for image archive, USB, 3-point laserTop-tier model with image capture, long discontinued
  1. Current Active Model: Fluke 572-2 (Replaces legacy 572)

Your target model, current main production unit

Medição de temperatura: Infrared -30 ~ 900℃; Termopar tipo K -270 ~ 1372℃

D:S=60:1, dual-laser targeting; 99 local storage records, USB export

Dual mode (infrared + contact thermocouple), audível & visual high/low temperature alarm

Indústrias: Poder, metalurgia, petroquímico, cement high-temperature inspection

III. Related Dual-Mode Infrared Thermometers (Commonly compared with 572-2 for selection)

Not part of 570 série, but Fluke handheld infrared + K-type thermocouple models frequently referenced in project selection

|Modelo|Infrared Range|D:S|Características|

|—|—|—|—|

|Fluke 568|-30~800℃|50:1|Dual mode, lower spec alternative to 572-2 with lower max temperature|

|Fluke 568 EX|-30~800℃|50:1|Intrinsically safe explosion-proof version for hazardous oil & gas area|

|Fluke 561|-40~550℃|12:1|HVAC dedicated entry-level dual mode unit|

  1. Infrared-only Models (No thermocouple, reference for category comparison, not in 570 série)

Fluke 62 MAX / 62 MAX+: -30~650℃, D:S=12:1, IP54, 3m drop resistance

Fluke 64 MAX: -30~600℃, D:S=20:1

  1. Model Version Remarks
  2. 572-2 has no sub-models, only standard main unit. Variants come from accessory kits: Optional carrying case, extended thermocouple probe, tripod
  3. Legado 572/574/576 permanently discontinued. Only surplus stock, refurbished or second-hand units available; calibration and spare parts are difficult to source. Selecione 572-2 para novos projetos
  4. Key distinction: Legacy models use 3-point laser; novo 572-2 uses dual laser targeting system