IFM PN7032 Pressure Sensor with Display

Modelo completo não.: PN-100-SER14-QFRKG/US/ /V PN7032 belongs to PN70xx series, a relative pressure sensor with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems. ✅ Key Specifications Item Parameter Measuring range 0…10 MPa (0~100 barras), relative ...

  • Detalhes do produto

Modelo completo não.: PN-100-SER14-QFRKG/US/ /V

PN7032 belongs to PN70xx series, a relative sensor de pressão with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems.

✅ Key Specifications

ItemParâmetro
Faixa de medição0…10 MPa (0~100 barras), relative pressure
Conexão de processoRosca interna G1/4; rotatable display head
Measuring elementCeramic-capacitive
Overpressure30 MPa; Pressão de ruptura 65 MPa
Saída2 x PNP switching outputs; OUT2 multiplexed for IO-Link
Fonte de energia18…30 V DC; proteção contra polaridade reversa & proteção contra curto-circuito
Temperatura média-25 ~ +80 ℃
Proteção de entradaIP67; M12 A-coded 5-pin gold-plated connector
Mostrar4-digit red/green digital display, tri-color status indicator, 3-key menu
Switch settingSP: 0.1~10 MPa; rP reset point; minimum hysteresis 0.05 MPa
Frequência de respostaMáx.. 170 Hz
MédioPrimarily for liquids; gas applications above 25 bar require separate evaluation

✅ Model Code Explanation

PN-100-SER14-QFRKG/US/ /V

PN: Series with display

100: Measuring range 0~10 MPa

S: 2 switching outputs

E: IO-Link function

R: Rosca interna G1/4

14: M12 5-pin electrical connector

QFRKG: Code for housing, sealing and electrical configuration

✅ Product Features

  1. Comunicação IO-Link: Read real-time pressure, temperature and diagnostic data; remote parameter read/write via PLC, device identification and fault diagnosis supported.
  2. Rotatable display head for convenient viewing after installation.
  3. Red/green color-changing display: green within valid pressure range, red when threshold exceeded.
  4. Ceramic cell, good resistance to pressure spikes and excellent long-term stability.
  5. Two independent switch points for high/low pressure dual alarm.
  6. Built-in short-circuit and reverse polarity protection, adequado para ambientes industriais agressivos.

✅ Typical Applications

Hydraulic station pressure monitoring, lube oil circuits, cooling water systems, high-pressure pneumatic loops, máquinas de moldagem por injeção, máquinas-ferramentas, estações de bombeamento, compressores de ar.

✅ Reference Replacement Models

PN7032 (0~10MPa, Rosca interna G1/4, Link IO)

PN7033: 0~2.5MPa

PN7034: 0~1MPa

PN7036: 0~0.25MPa

Observação: PN7032 is partially phased out. Para novos projetos, consult IFM PN72 series alternatives. Fio, faixa de medição, IO-Link and output logic need to be verified.

✅ Pin Assignment (M12 5-pin A-coded)

1: Power +18~30V DC

2: SAÍDA1 (PNP switch)

3: Potência GND

4: SAÍDA2 / Link IO

5: Não usado

✅ Common Troubleshooting

  1. Sem exibição: Check supply voltage and confirm no reverse connection.
  2. Pressure reading drift: Verify medium temperature and pressure spikes upstream; ceramic cell is vulnerable to continuous overpressure.
  3. IO-Link communication failure: Check pin 4, IO-Link master baud rate and matched IODD file.
  4. Switch output not actuating: Enter menu to verify SP/rP setting and output mode (window / histerese).

Tabela de comparação: IFM PN7032 vs PN72 Series (PN7292, Substituição Direta)

PN7032: PN-100-SER14-QFRKG/US/ /V (descontinuado)

PN7292: PN-100-REN14-QFRKG/US/ /V (official recommended replacement, 0~10MPa, Rosca interna G1/4, 2×PNP + Link IO)

Item de comparaçãoPN7032PN7292 (PN72 Series Replacement)Observações
Modelo CompletoPN-100-SER14-QFRKG/US/ /VPN-100-REN14-QFRKG/US/ /VFaixa de medição idêntica: 0…10 MPa (0~100 barras) relative pressure
Measuring CellCeramic-capacitiveCeramic-capacitiveMesmo, resistant to pressure spikes, suitable for hydraulic/lube oil
Conexão de ProcessoRosca interna G1/4Rosca interna G1/4Mechanically fully compatible, direct swap-in
Conector ElétricoM12 A-coded 5-pinM12 A-coded 5-pinPinout identical, no cable rework required
Configuração de saída2×PNP switching outputs, OUT2 multiplexed IO-Link2×PNP switching outputs, OUT2 multiplexed IO-Link; output software-selectable PNP/NPNPN72 adds PNP/NPN software switching
Fonte de energia18…30 V DC18…30 V DCMesmo intervalo, reverse polarity & proteção contra curto-circuito
Overpressure30 MPa30 MPaIdêntico
Burst Pressure65 MPa65 MPaIdêntico
Temperatura média−25 ~ +80 ℃−25 ~ +80 ℃Mesma faixa de temperatura
Proteção de entradaIP67IP67Same housing protection
Mostrar4-digit red/green digital display, tri-color status, 3 chaves4-digit red/green LED, side status indicators, 3 chavesSame display logic; display head 360° rotatable
IO-Link VersionLink IO 1.1Link IO 1.1IODD files differ; PLC project needs IODD update
Switch Point SetupSP, rP hysteresis; min hysteresis 0.05 MPaSP, rP hysteresis; min hysteresis 0.05 MPaMenu logic mostly consistent; PN72 supports more pressure units
Frequência de respostaMáx.. 170 HzMáx.. 170 HzSame dynamic response
Dimensão GeralIdentical body outlineIdentical body outlineNo modification to mounting space or bracket
Principais diferençasSaída PNP fixaSoftware PNP/NPN toggle; more menu parameters; extended diagnostic information; improved service life (>100 million pressure cycles)✅ Direct replacement for most applications; ⚠️ IO-Link projects require IODD update

PN72 Series Selection List for PN70xx Equivalents

Faixa de mediçãoOriginal PN70xx ModelPN72 Series ReplacementFio
0~10 MPa /100 barPN7032PN7292Rosca interna G1/4
0~2.5 MPa /25 barPN7033PN7293Rosca interna G1/4
0~1 MPa /10 barPN7034PN7294Rosca interna G1/4
0~0.25 MPa /2.5 barPN7036PN7296Rosca interna G1/4

⚠️ Replacement Engineering Notes

  1. Instalação Mecânica: Thread and physical dimensions are identical; can be directly screwed into existing piping.
  2. Fiação Elétrica: M12 5-pin pinout fully identical, no cable modification needed.
  3. Switch-only Application (Sem link IO): Substituição direta, re-set SP/rP parameters only; PLC program unchanged.
  4. IO-Link Application: IODD file update mandatory. PN7032 and PN7292 IODD are not interchangeable; different device ID, PLC will recognize it as new equipment.
  5. Tipo de saída: PN7032 fixed PNP; PN7292 factory default PNP, can be switched to NPN via menu.
  6. Pressure Units: PN72 supports more units (bar/MPa/psi etc.), older PN7032 has fewer unit options.
  7. Media Note: Ceramic cell, avoid strongly corrosive media; high-pressure gas applications require separate evaluation.

Limitation Statement

PN72 series (PN7292) is functionally compatible replacement instead of 100% firmware identical. Diagnostic parameters and device ID read via IO-Link differ. For pure switch signals, zero-modification replacement; IO-Link projects require PLC IODD update and parameter download.

Complete Installation Instructions for IFM PN7032 Pressure Sensor

PN7032: Rosca interna G1/4, M12 A-coded 5-pin, ceramic cell, gauge pressure 0~10MPa; Depressurize system and cut off power before installation

  1. Preparação de pré-instalação
  2. Safety Check

Shut down and depressurize piping; confirm medium, temperature and maximum pressure do not exceed PN7032 specification (medium -25~80℃, overpressure 30MPa).

  1. Pressure Tap Selection

Liquid medium: Tap taken from side of pipe to prevent air bubbles accumulating on measuring cell.

Gas medium: Tap taken from top of pipe to avoid liquid pooling on cell.

Avoid locations after pumps, valves and elbows with pressure spikes and high turbulence. Add snubber/damper under heavy vibration to protect ceramic cell.

  1. Piping Pre-treatment

Purge piping to remove metal chips and weld slag; debris can scratch ceramic diaphragm and cause zero drift.

  1. Sealing Parts Preparation

G1/4 is parallel pipe thread. Do NOT wrap large amount of PTFE tape. Copper gasket or O-ring is preferred. A small amount of thread sealant is allowed, but sealant must not squeeze into pressure chamber, which will permanently damage the cell.

  1. Ferramentas: Chave de torque, M12 pre-assembled cable, spanner.
  2. Montagem Mecânica (Pressure Piping Connection)
  3. Align sensor G1/4 thread with pipe fitting, hand-tighten first. Do NOT use spanner on plastic display housing directly.
  4. Torque de aperto recomendado: 25~35 N·m. Must use torque wrench. Excessive torque causes housing deformation and ceramic cell cracking; insufficient torque causes leakage.
  5. Display Head Rotation: After tightening thread, the electronic display head can be rotated 345° for optimal viewing angle. Do not rotate beyond mechanical end stop, forced rotation damages internal wiring.

⚠️ Nota: Rotate the upper display head, NOT the pressure thread base.

  1. Após a instalação, pressurize slowly and check thread for leakage.
  2. Fiação Elétrica (M12 A-coded 5-pin)

Perform wiring with power OFF. IFM original M12 prefabricated cable recommended. Torque de aperto do conector M12: 0.6~1.2 Nm to maintain IP67.

Pino Não.Cor do fioDefiniçãoObservações
1BN MarromDC+ 18~30VPoder positivo
2WH WhiteSAÍDA1 (Saída de comutação PNP)Switch channel 1
3BU AzulCC- GNDPotência negativa
4BK PretoSAÍDA2 / Link IOCanal 2, IO-Link multiplex port
5-Não usadoSpare pin

Saída: 2×PNP, max load current 250mA per channel.

IO-Link usage: Alfinete 4 for IO-Link communication.

Recomendação de cabo: 0.34~0.5mm². Route IO-Link wiring away from frequency converters and high-power power cables to reduce interference.

  1. Ligar & Comissionamento
  2. Double-check wiring for correctness and short circuit; fasten M12 connector.
  3. Apply DC24V power slowly, display lights up.
  4. Menu configuration: Set switch point SP, reset point rP, select window / hysteresis mode and pressure unit.
  5. Zero point verification: Confirm reading near 0 bar when piping is depressurized.
  6. Pressurize gradually, verify pressure reading and switch output actuation.
  7. IO-Link application: Import IODD file in PLC, identify device, read pressure, temperature and diagnostic parameters.
  8. Critical Installation Prohibitions (Engineering Key Points)
  9. ❌ Do NOT mount or demount sensor under pressure; high-pressure ejection may injure personnel and damage equipment.
  10. ❌ Do NOT use spanner on plastic display housing to tighten thread; only clamp lower metal thread base.
  11. ❌ Heavy PTFE tape on G1/4 thread; debris entering pressure chamber scratches ceramic cell.
  12. ❌ Over-tightening torque, may fracture ceramic measuring element.
  13. ❌ Direct medium impact above 80℃; add cooling buffer for high-temperature media.
  14. ❌ Operation under heavy shock and continuous vibration without snubber, leading to zero drift and shortened service life.
  15. ❌ Hot plug/unplug M12 connector, risk of burning output circuit.
  16. Post-installation Check List

No leakage at thread connection

M12 connector tightened, IP67 intact

Tensão de alimentação: 18~30V CC

No short circuit or reverse polarity

Zero reading normal with no applied pressure

Switch point action normal / IO-Link communication stable

  1. Replacement Hint for PN7292

Montagem mecânica, fio, torque and M12 pinout are fully identical; piping and cables remain unchanged. Only IO-Link projects require IODD file update.