Leuze CML720i-T05-240.A-M12 - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Leuze CML720i-T05-240.A-M12 - Contator,disjuntor,sensor,Codificador,CLP,Conversor

elétrica/

Leuze CML720i-T05-240.A-M12

Item nº.: 50119370|Measuring light curtain transmitter (transmitter only, must be used with paired receiver) ✅ Model Code Explanation Field Description CML720i CML series measuring light curtain; 720i general-purpose measuring light curtain T Transmitter; R = Receiver 5 Beam pitch 5 milímetros 240 Effective measuring height 240 mm A A = Axial M12 connector (straight outlet); R = ...

  • Detalhes do produto

Item nº.: 50119370|Measuring light curtain transmitter (transmitter only, must be used with paired receiver)

✅ Model Code Explanation

CampoDescrição
CML720iCML series measuring light curtain; 720i general-purpose measuring light curtain
TTransmissor; R = Receiver
5Beam pitch 5 milímetros
240Effective measuring height 240 milímetros
UMA = Axial M12 connector (straight outlet); R = Rear outlet
M12Conector M12, 5-pin A-coded

📌 Key Technical Specifications

Princípio: Infrared through-beam measuring light curtain, NOT safety light curtain. Used for dimension inspection, object contour detection, contando, material level monitoring and other measurement applications

Faixa de medição eficaz: 240 milímetros, total 48 vigas, beam pitch: 5 milímetros

Minimum detectable object diameter: 10 milímetros

Faixa operacional: 0.1~3.5 m (guaranteed range)

Fonte de energia: DC 18~30V, reverse polarity & proteção contra curto-circuito

Cycle response time: 1.84 EM

Fonte de luz: Infrared LED 940nm

Classe de proteção: IP65

Temperatura ambiente: Operating -30℃ ~ +60℃; Storage -40℃ ~ +70℃

Habitação: Aluminum alloy profile, supplied with 2 BT-NC mounting sliders

Dimensão geral: W29 × D35.4 × L315 mm

🔌 Electrical Interface (M12 5-pin male A-coded)

AlfineteDefinição
1FE Shield
2V+ Power Positive
3GND Power Ground
4RS485 Tx+
5RS485 Tx-

The transmitter only emits infrared beams. All communication and signal output are implemented on the receiver side. Optional receiver interfaces: CANopen / Profinet / Link IO / Saída analógica

🧩 Matching Receiver Selection (Mesma especificação: 240milímetros, 5mm beam pitch)

CML720i-R05-240.A/CN-M12: Barramento CANopen

CML720i-R05-240.A/PB-M12: Profibus

CML720i-R05-240.A/PN-M12: Profinet

CML720i-R05-240.A/CV-M12: Analog voltage / current output

📋 Typical Applications

Altura / width measurement of objects on conveyor lines

Missing part inspection & contour detection for cartons

Material counting, gap detection

Detecção de objetos transparentes (CML720i supports transparent part recognition)

Classificando, embalagem, dimension inspection for timber & boards

⚠️ Distinção importante

  1. CML720i = Measuring light curtain, no safety certification. Cannot be used for personnel safety protection; Safety light curtain series: MLC.
  2. Complete system = Transmitter (T) + Receptor (R) paired. Transmitter alone cannot work.
  3. Suporta 3 scanning modes: Parallel beam / Slanted beam / Cross beam, configurable via receiver.

Referência do Código HS

90314990 (Optical measuring sensor / photoelectric detection device)

Guia de solução de problemas

  1. Power ON, transmitter green LED steady ON: Normal; Piscando: Synchronization error (transmitter-receiver out of sync, wiring fault)
  2. Sem sinal: Check parallel installation of transmitter & receptor, operating distance ≤3.5m, no strong direct light on lens
  3. Inaccurate measurement: Lente limpa, verify beam mode setting, eliminate reflection interference

✅ Matching Receiver for CML720i-T05-240.A-M12 (Item No.50119370)

Regra modelo: CML720i-R05-240.A/xx-M12

R=Receiver; 05=5mm beam pitch; 240mm measuring height; A=Axial M12 straight connector; /xx = Interface suffix

Complete Receiver ModelItem nº.Tipo de interface
CML720i-R05-240.A/CN-M1250119608CANopen
CML720i-R05-240.A/PN-M1250131878Profinet
CML720i-R05-240.A/PB-M1250119609Profibus
CML720i-R05-240.A/CV-M1250119610Analógico (Tensão / Atual)
CML720i-R05-240.A/L-M1250119606Link IO

Notas de seleção

  1. Transmitter and receiver must be fully matched: 5mm beam pitch, 240mm measuring height, A-type axial M12 connector consistent with transmitter. Only receiver adds interface suffix /xx
  2. Transmitter only carries power & sync lines; All measurement output and bus communication are integrated in receiver
  3. Identical mechanical dimensions: W29 × D35.4 × L315 mm, supplied with 2 BT-NC mounting sliders

Cable Information

Sync cable between transmitter & receptor: M12 5-core, connects Transmitter ↔ Receiver

Receiver connects to PLC via separate bus / analog cable

Full Wiring for Slogan CML720i (4 Interface Versions)

General architecture: Receiver X1 (8-pin M12 A-coded) main port: Fonte de energia + OI + sync line to transmitter; Transmitter X3 fixed as 5-pin M12 A-coded.

Transmitter Model: CML720i-T05-240.A-M12 (X3: 5-pino M12)

Receiver X1【8-pin M12 A-coded】(Pin definition identical for all versions!)

✅ Receiver X1 (8-pin M12 A-coded, common for all variants)

AlfineteSinalObservações
1V+ DC24VPoder Positivo
2I/O1 (Configurável)Padrão de fábrica: Teach input
3GND 0VAterramento de energia
4C/Q IO-LinkLinha de comunicação IO-Link (reserved for CV/CN/PN versions)
5I/O2 (Configurável)Can be set as alarm / status output
6RS485 Tx-Sync signal between transmitter & receptor
7RS485 Tx+Sync signal between transmitter & receptor
8FE/ShieldHousing earth, shield connect to this pin

✅ Transmitter X3 (5-pin M12 A-coded, fixed definition)

AlfineteSinal
1FE Shield
2V+ 24V
3GND 0V
4RS485 Tx+
5RS485 Tx-

👉 Receiver X1 Pin1,Pin3,Pin6,Pin7 → Connect to Transmitter X3 Pin2,Pin3,Pin4,Pin5. Use Leuze Y-type sync cable, max length 20m.

1️⃣ CML720i-R05-240.A/PN-M12|Profinet Version

Receiver equipped with 3 M12 connectors:

X1: 8-alfinete (Poder + Sincronizar + OI, see table above)

X2: BUS IN (4-pin M12 D-coded)

X3: BUS OUT (4-pin M12 D-coded)

Profinet D-coded M12 (4-alfinete):

AlfineteSinalCor do fio
1TD+Amarelo
2RD+Branco
3DT-Laranja
4DR-Azul

Wiring Architecture:

DC24V supplied to receiver X1; Sync cable from X1 to transmitter; Profinet bus connects PLC/switch to X2, X3 daisy-chains next PN device; Enable terminator resistor on last station.

Supports PLC reading: Blocked beam number, height value, diagnostic status.

2️⃣ CML720i-R05-240.A/CN-M12|CANopen Version

Receptor: X1 (8-alfinete, Poder + Sincronizar) + X2 (5-pin M12 A-coded CAN bus)

CAN bus X2 (5-pin M12 A-coded)

AlfineteSinal
1FE Shield
2NC Not Connected
3CAN GND
4CAN H
5CAN L

Fiação: X1 power & sync to transmitter; CAN H/CAN L connect to CAN bus; 120Ω terminator resistor required at both ends of bus.

3️⃣ CML720i-R05-240.A/L-M12|IO-Link Version

Receiver only has X1 (8-pin M12 A-coded), no extra bus port. IO-Link multiplexes Pin4 (C/Q) of X1.

Pino1: 24V+

Pino3: 0V

Pino 4: C/Q IO-Link communication → Directly connect to PLC IO-Link master port

Pin2/Pin5: E/S digital (Ensinar, fault output)

Pin6/7: Sync to transmitter

IO-Link master reads measured height and beam data directly, no extra bus cable required.

4️⃣ CML720i-R05-240.A/CV-M12|Analog Version (Tensão / Atual)

Receiver also only has X1 (8-pin M12 A-coded), analog output on X1 Pin7.

Pino 7: Analog OUT Analog Output

Parameter switchable: 0~10V or 4~20mA

Full scale corresponds to measuring height 0~240mm

Pin1/3: 24Fonte de alimentação V

Pin6/7: Sync signal to transmitter

Pin2/Pin5: E/S digital (Falta / Ensinar)

⚠️ Nota: Analog output and RS485 sync share Pin7, internal auto switching. Wiring remains unchanged; voltage/current mode configured via Leuze software.

📌 General Wiring Guidelines

  1. Power supply range DC18~30V, DC24V recommended; Isolated power supply required, shield single-point grounding.
  2. Sync cable (Transmitter ↔ Receiver) max length 20m; Bus cable max 40m, shielded cable mandatory.
  3. Sequência de fiação: Connect shield ground first → Wire all signals → Power ON; Power OFF before disassembly.
  4. IO1 default as Teach input, short to GND to trigger teach routine for zero calibration.
  5. Separate signal cables from power cables to avoid interference from frequency converters.

🧾 Quick Selection Guide

CLP Siemens: Prefer PN Profinet version

Industrial control system with CAN bus: CN CANopen

Compact PLC with IO-Link master: L IO-Link

Legacy equipment requiring analog acquisition: CV 4~20mA / 0~10V

Anterior:

Próximo:

Deixe uma resposta