MCCB LS EBS203C-200A-3P

EBS203C-200A-3P is a 3-pole, 200A rated earth-leakage molded case circuit breaker (MCCB/ELCB) fabricado pela LS Electric (anteriormente LS Sistemas Industriais / LG Sistemas Industriais). It provides overcurrent, short-circuit and earth-leakage protection for three-phase electrical circuits. 📌 Model Explanation EBS203C: EBS series earth-leakage MCCB; 200 = tamanho do quadro (AF), 3 = number of poles (3P), C ...

  • Detalhes do produto

EBS203C-200A-3P is a 3-pole, 200A rated earth-leakage disjuntor em caixa moldada (MCCB/ELCB) fabricado pela LS Electric (anteriormente LS Sistemas Industriais / LG Sistemas Industriais). It provides overcurrent, short-circuit and earth-leakage protection for three-phase electrical circuits.

📌 Model Explanation

EBS203C: EBS series earth-leakage MCCB; 200 = tamanho do quadro (AF), 3 = number of poles (3P), C = thermal-magnetic trip type (MT).

200UM: Corrente operacional nominal 200 amperes.

3P: 3 postes, suitable for three-phase three-wire systems.

⚙️ Key Specifications

ItemEspecificação
Frame size (AF)200AF~399AF
Rated short‑circuit breaking capacity (UTI)85kA at AC220V; 37kA at AC400V
Tensão nominalAC220/460V
Protection functionsSobrecarga, curto-circuito, earth leakage (100/200/500mA optional)
Tipo de viagemThermal‑magnetic trip (MT), instantaneous trip rating 12×In
Dimensões (A×L×P)165×105×87mm
PesoAprox.. 1.2kg
CertificaçõesCE, CCC

🛠️ Applications & Compatibilidade

Aplicações típicas: Distribuição de energia industrial, production line equipment, power and lighting circuits, suitable for three-phase applications requiring reliable earth-leakage and short-circuit protection.

Recommendation: Can be used with Meta-MEC series products for selective protection and coordination to improve system reliability.

🔄 Equivalent & Series Models

Same series: EBS203C-100A/125A/150A/175A, EBS204C (4-pólo), etc..

Alternative references: ABB Tmax series, Schneider NSX series, Chint NM8L series and other equivalent earth-leakage MCCBs. Breaking capacity and mounting dimensions must be matched.

📦 Supply & Aquisições

Marca: LS Electric (LSIS), originally manufactured in South Korea.

Purchasing channels: Authorized LS Electric distributors in China, industrial platform www.bestcontactor.com. Typical price is around one thousand RMB; negotiable for bulk orders.

The core difference between EBS203C-200A-3P and EBS203C-200A-4P (modelo padrão: EBS204C-200A) lies in the number of poles and the control method of the neutral (N) conductor, which directly affects wiring, protection scope and application scenarios.

  1. Structural Differences

EBS203C-200A-3P (3-pólo)

Estrutura: 3 line/incoming terminals, controlling only L1, L2, L3 (three-phase live conductors).

Neutral (N): Does not pass through the breaker; directly connected.

Proteção: Provides overload, short-circuit and earth-leakage protection only for three-phase live conductors.

EBS204C-200A-4P (4-pólo)

Estrutura: 4 line/incoming terminals, controlling L1, L2, L3 + N (three-phase live conductors + neutral).

Neutral (N): Passes through the breaker and switches simultaneously with phase conductors.

Proteção: Protects three-phase live conductors + neutral and can disconnect a faulty neutral line.

  1. Key Parameter Comparison
ItemEBS203C‑200A‑3PEBS204C‑200A‑4P
Frame / Atual200AF, 200UM, thermal‑magnetic type CIdêntico
Capacidade de ruptura37kA at AC400V; 85kA at AC220VIdêntico
Protection functionsSobrecarga, curto-circuito, earth leakageIdêntico
Poloneses3P (3‑pole)4P (4‑pole)
Neutral (N)Bypasses the breakerSwitched with phases
LarguraNarrower (aprox.. 105milímetros)Wider (aprox.. 140milímetros)
Applicable systemThree‑phase three‑wire (IT, TN‑C without PEN)Three‑phase four‑wire (TN‑S, TN‑C‑S, TT)

III. Functional & Safety Differences

  1. Switching range

3P: Switches phases only. Neutral remains live, posing electric shock risk during maintenance.

4P: Switches both phases and neutral. Fully isolates power, safer and compliant with standards.

  1. Earth-leakage protection effectiveness

3P: Only detects three-phase current imbalance. Cannot protect against neutral faults (por exemplo, neutral-to-earth short circuit).

4P: Monitors total current of four poles (L1-L2-L3-N), trips on neutral leakage for complete protection.

  1. System compatibility

3P: Suitable for pure three-phase loads (motores, bombas) with no single-phase loads and no neutral in the panel.

4P: Suitable for mixed three-phase + single-phase systems (comercial, industrial, building distribution); neutral disconnection required for safety.

  1. Guia de seleção

Choose 3P (EBS203C):

Loads are pure three-phase motors, compressores, heaters, etc., with no 220V single-phase circuits.

Neutral in the distribution box does not pass through this breaker; space is limited.

Choose 4P (EBS204C):

System is TN-S / TN-C-S (separate N and PE conductors).

Circuit supplies single-phase loads (iluminação, tomadas, control circuits); neutral must be switched.

Required by safety standards (manutenção, earth-leakage protection, earthing systems).

Resumo

3P = space-saving, cost-effective → dedicated for three-phase power

4P = safer, more complete → required for mixed power distribution

LS Electric EBS Series Earth-Leakage MCCBs (ELCB): Model List & Cross-Brand Cross-Reference

  1. EBS Series Model System & Full List

Core features of EBS series: Earth-leakage molded case circuit breakers on LS Electric’s (formerly LS / LG Sistemas Industriais) Metasol platform, with built-in earth-leakage protection modules, fornecendo proteção tripla contra sobrecarga, short-circuit and residual current (earth leakage) for low-voltage distribution systems.

  1. Model Naming Convention

EBS □□□ – □□□A – □P

EBS: Series code (earth-leakage MCCB)

1st digit: Frame size (5=50AF, 10=100AF, 20=200AF, 40=400AF)

2nd digit: Número de pólos (3=3P, 4=4P)

3rd letter: Breaking capacity class (C=standard, S=high)

□□□A: Corrente nominal (Em)

□P: Número de pólos (3P/4P, consistent with 2nd digit)

  1. Complete Model List by Frame Size

1) 50AF Frame (EBS53C / EBS54C)

PolonesesCorrente nominalModelo CompletoQuebrando Capacidade (AC400V)
3P10A/16A/20A/25A/32A/40A/50AEBS53C‑10A~50A18o
4P10A/16A/20A/25A/32A/40A/50AEBS54C‑10A~50A18o

2) 100AF Frame (EBS103C / EBS104C)

PolonesesCorrente nominalModelo CompletoQuebrando Capacidade (AC400V)
3P63A/75A/100AEBS103C‑63A/75A/100A37o
4P63A/75A/100AEBS104C‑63A/75A/100A37o

3) 200AF Frame (EBS203C / EBS204C)

PolonesesCorrente nominalModelo CompletoQuebrando Capacidade (AC400V)
3P125A/150A/175A/200A/225A/250AEBS203C‑125A~250A37o
4P125A/150A/175A/200A/225A/250AEBS204C‑125A~250A37o

4) 400AF Frame (EBS403C / EBS404C)

PolonesesCorrente nominalModelo CompletoQuebrando Capacidade (AC400V)
3P250A/300A/350A/400AEBS403C‑250A~400A50o
4P250A/300A/350A/400AEBS404C‑250A~400A50o
  1. Earth-Leakage Parameters (Whole Series)

Residual operating current (Eu não): 30mA/100mA/300mA/500mA optional (default 30mA for personal protection)

Operating time: ≤0.3s (IΔn=30mA), ≤0,1s (IΔn≥100mA)

Protection type: Type A (AC + pulsating DC leakage), suitable for modern electronic loads

  1. Cross-Brand Equivalent Table for EBS Series

Below are equivalent models from major brands with matching core parameters (quadro, corrente nominal, postes, capacidade de interrupção) for replacement reference.

LS EBS ModelABB Tmax XTSchneider NSXChint NM8LDelixi CDM1L
EBS53C‑50A‑3PXT1N160 TMD50 3P RCCBNSX100N TM50D 3P VigiNM8L‑100S/3300 50ACDM1L‑100C/3300 50A
EBS103C‑100A‑3PXT1N160 TMD100 3P RCCBNSX100N TM100D 3P VigiNM8L‑100S/3300 100ACDM1L‑100C/3300 100A
EBS203C‑200A‑3PXT2N250 TMD200 3P RCCBNSX250N TM200D 3P VigiNM8L‑250S/3300 200ACDM1L‑250C/3300 200A
EBS204C‑200A‑4PXT2N250 TMD200 4P RCCBNSX250N TM200D 4P VigiNM8L‑250S/4300 200ACDM1L‑250C/4300 200A
EBS403C‑400A‑3PXT4N630 TMD400 3P RCCBNSX630N TM400D 3P VigiNM8L‑630S/3300 400ACDM1L‑630C/3300 400A

Key Notes for Replacement

  1. Correspondência de capacidade de ruptura: Select alternatives with breaking capacity ≥ original EBS model to ensure short-circuit protection reliability.
  2. Earth-leakage module compatibility:

ABB requires RC221/RC222 earth-leakage accessories

Schneider requires Vigi modules (embutido / add-on)

Domestic NM8L/CDM1L have built-in earth-leakage modules, no extra parts needed

  1. Mounting dimension check: Width may vary between brands (por exemplo, EBS203C-200A-3P: 105milímetros; Schneider NSX250: 108milímetros), affecting panel layout.
  2. Wiring type: Ensure replacement supports original mounting (fixo / plug-in) and connection (front / rear wiring).

III. Principais diferenças: EBS203C-200A-3P vs EBS204C-200A-4P

ItemEBS203C‑200A‑3P (3‑pole)EBS204C‑200A‑4P (4‑pole)
Poloneses & Terminais3 main terminals (L1/L2/L3)4 main terminals (L1/L2/L3/N)
Neutral controlNeutral bypasses breakerNeutral switched with phases
Protection scopeSobrecarga, curto-circuito, leakage on phases onlyFull protection on phases + neutral (including neutral leakage)
Largura105milímetros140milímetros
Applicable system3‑phase 3‑wire (IT, TN‑C without PEN)3‑phase 4‑wire (TN‑S, TN‑C‑S, TT)
Safety levelPhases switched only; extra isolation neededFull isolation; higher safety
  1. Seleção & Procurement Advice
  2. Seleção de pólo

Pure three-phase power loads (motores, compressores) → choose 3P (EBS203C)

Mixed three-phase + single-phase loads (iluminação, tomadas) → choose 4P (EBS204C) to meet safety standards

  1. Earth-leakage current selection

Personal protection (socket circuits) → IΔn = 30mA

Electrical fire prevention (power/lighting mains) → IΔn = 100mA / 300mA

  1. Purchasing channels

Authorized domestic distributors, industrial e-commerce platform www.bestcontactor.com

Regular stock models: EBS53C-50A, EBS103C-100A, EBS203C-200A, EBS403C-400A, etc..