Schneider A9F18216

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker First, it should be clarified that A9F18216 is a miniature circuit breaker (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, proteção contra curto-circuito e fuga à terra, while A9F18216 only provides overload and ...

  • Detalhes do produto

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker

Primeiro, it should be clarified that A9F18216 is a disjuntor miniatura (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, proteção contra curto-circuito e fuga à terra, while A9F18216 only provides overload and short-circuit protection. For earth leakage protection, it must be used with an additional Vigi iC60 or QuickVigi iC60 residual current module.

Detalhamento do código do modelo

Peça do modeloSignificado
iC65NSérie de produtos: Série Acti9 iC65; N stands for 6kA breaking capacity
2PNúmero de pólos: 2 postes (Linha + Neutro)
CCurva de tropeço: Tipo C, for power distribution and lighting circuits; instantaneous tripping at 5–10× rated current
16UMCorrente nominal: 16 amperes
A9F18216Schneider official order code

Especificações Técnicas Principais

ItemEspecificação detalhada
Tipo de produtoDisjuntor Miniatura (MCB)
SérieActi9 iC65N
Número de poloneses2P (2-sistema de fios, 2 protected poles)
Corrente nominal (Em)16UM
Curva de tropeçoTipo C
Quebrando Capacidade (UTI)6o (400V e)
Tensão nominal230/400V e
Freqüência50/60Hz
Dimensões2 módulos (36mm largura)
MontagemMontagem em trilho DIN
Grau de ProteçãoIP20
Tipo de disparoTermomagnético (sobrecarga: bimetal strip; curto-circuito: magnetic coil)
Padrões AplicáveisCEI 60898-1

Recursos do produto & Funções

  1. Proteção confiável: Provides overload and short-circuit protection to prevent electrical fires and equipment damage
  2. Type C Curve: Suitable for power distribution, lighting circuits and resistive loads, with good inrush current tolerance
  3. Design Compacto: 2-largura do módulo, saving space in distribution boards
  4. VisiTrip Indicator: Red mechanical window shows trip status for quick fault diagnosis
  5. Multiple Wiring Methods: Supports front, rear and rail-mounted wiring to meet various installation needs
  6. Ampla faixa de temperatura operacional: -25°C a +40°C, adaptable to various environments

Difference from RCBO and Earth Leakage Protection Solutions

Tipo de produtoFunções de proteçãoModelo típicoInstalação
A9F18216 (iC65N 2P C16A)Sobrecarga + Curto-circuitoA9F18216Standalone
RCBO (iC65N Vigi+)Sobrecarga + Curto-circuito + Earth LeakageA9D11216 (2P C16A 30mA Type A)Integrated
MCB + Leakage ModuleSobrecarga + Curto-circuito + Earth LeakageA9F18216 + A9Q41216 / A9V41216Module attached to right of MCB

To upgrade A9F18216 to a system with earth leakage protection, you may choose:

QuickVigi iC60 2P 16A 30mA module (A9Q41216, 1.5 módulos, economia de espaço)

Vigi iC60 2P 16A 30mA module (A9V41216, 3 módulos, versão padrão)

Aplicativos

Suitable for overload and short-circuit protection in final distribution systems, especially for:

Lighting circuits in residential and commercial buildings

Circuits for small power equipment and resistive loads

Branch protection in distribution boards

Applications requiring flexible combination with earth leakage modules

Key Installation & Instruções de operação

  1. Montado em trilho DIN padrão de 35mm
  2. Faixa de temperatura operacional: -25°C a +40°C
  3. Grau de poluição: 3
  4. Tensão nominal suportável de impulso (Um): 6kV
  5. Capacidade de fiação: máx.. 25cabo mm²
  6. Resistência mecânica: 20,000 ciclos operacionais

A9F18216 is a commonly used 2P 16A Type C MCB from Schneider’s Acti9 series, offering reliable overload and short-circuit protection. Se for necessária proteção contra fuga à terra, a corresponding residual current module must be added, or an RCBO from the iC65N Vigi+ series (por exemplo, A9D11216) can be selected directly.

Supplementary Information for Schneider A9F18216: Official Ordering, Full Series List & Chinese Domestic Alternatives

  1. Informações oficiais sobre pedidos
ItemDetalhes
Nome do produtoiC65N 2P C16A Miniature Circuit Breaker (MCB)
Código de pedido oficialA9F18216
SérieActi9 iC65N (N = 6kA breaking capacity)
Quadro atual63UM
Tensão nominal230/400V e
Freqüência50/60Hz
Quebrando Capacidade (UTI)6o (400V e)
Curva de tropeçoTipo C (instantaneous trip at 5–10× In)
Número de poloneses2P (2-arame, Linha + Neutro)
Corrente nominal16UM
Dimensões2 módulos (36mm largura)
MontagemMontagem em trilho DIN
Grau de ProteçãoIP20
Padrões AplicáveisCEI 60898-1, GB 14048.2
Capacidade de fiaçãoMáx.. 25cabo mm²
Resistência Mecânica20,000 ciclos operacionais
Período de garantia12 meses
  1. Full Model List of iC65N Series (A9F Prefix)

The iC65N series is categorized by pole number. Order code rule: A9F + [Pole Code] + [Current Code]

Pole codes: 11=1P, 12=2P, 13=3P, 14=4P

Current codes: 06=6A, 08=8A, 10=10A, 13=13A, 16=16A, 20=20A, 25=25A, 32=32A, 40=40A, 50=50A, 63=63A

1P Models (A9F181xx)

Corrente nominalCódigo do pedidoCurva de tropeço
6UMA9F18106Tipo C
8UMA9F18108Tipo C
10UMA9F18110Tipo C
13UMA9F18113Tipo C
16UMA9F18116Tipo C
20UMA9F18120Tipo C
25UMA9F18125Tipo C
32UMA9F18132Tipo C
40UMA9F18140Tipo C
50UMA9F18150Tipo C
63UMA9F18163Tipo C

2P Models (A9F182xx)

Corrente nominalCódigo do pedidoCurva de tropeço
6UMA9F18206Tipo C
8UMA9F18208Tipo C
10UMA9F18210Tipo C
13UMA9F18213Tipo C
16UMA9F18216Tipo C
20UMA9F18220Tipo C
25UMA9F18225Tipo C
32UMA9F18232Tipo C
40UMA9F18240Tipo C
50UMA9F18250Tipo C
63UMA9F18263Tipo C

3P Models (A9F183xx)

Corrente nominalCódigo do pedidoCurva de tropeço
6UMA9F18306Tipo C
8UMA9F18308Tipo C
10UMA9F18310Tipo C
13UMA9F18313Tipo C
16UMA9F18316Tipo C
20UMA9F18320Tipo C
25UMA9F18325Tipo C
32UMA9F18332Tipo C
40UMA9F18340Tipo C
50UMA9F18350Tipo C
63UMA9F18363Tipo C

4P Models (A9F184xx)

Corrente nominalCódigo do pedidoCurva de tropeço
6UMA9F18406Tipo C
8UMA9F18408Tipo C
10UMA9F18410Tipo C
13UMA9F18413Tipo C
16UMA9F18416Tipo C
20UMA9F18420Tipo C
25UMA9F18425Tipo C
32UMA9F18432Tipo C
40UMA9F18440Tipo C
50UMA9F18450Tipo C
63UMA9F18463Tipo C

Modelos Especiais (Tipo D / Alta capacidade de ruptura)

ModeloDescriçãoCódigo do pedido
iC65N 2P D16ACurva tipo D (10–14×In), for motor loadsA9F18216D
iC65H 2P C16AHigh breaking capacity 10kAA9F18216H
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216L
  1. Chinese Domestic Brand Alternatives (2P C16A MCB)
MarcaSérieModeloQuebrando CapacidadePrincipais recursosReferência de Preço
CHINTEditora-63NXB-63 2P C16A6oLeading domestic brand, econômico, CCC certified40–50% of Schneider
DELIXIDZ47sDZ47s 2P C16A6oWell-known domestic brand, qualidade confiável, widely used40–50% of Schneider
NAXINNDM1NDM1-63 2P C16A6oIndustrial-grade quality, suitable for engineering projects50–60% of Schneider
Interruptor ChangshuCH1CH1-63 2P C16A6oEstablished state-owned enterprise, tecnologia madura50–60% of Schneider
Pessoas elétricasRMK-63RMK-63 2P C16A6oPreço acessível, suitable for bulk purchase30–40% of Schneider

Key Selection Guidelines for Alternatives

  1. Matching breaking capacity: Ensure alternative ≥6kA, same as iC65N
  2. Matching tripping curve: Type C for power/lighting; Type D for motors
  3. Dimension compatibility: Todos 2 módulos (36milímetros), Montagem em trilho DIN, fits distribution boards
  4. Complete certification: Must have CCC; CE recommended for industrial use
  5. Capacidade de fiação: Ensure max. wiring ≥25mm² to meet site requirements
  6. Earth Leakage Protection Upgrade Solutions

Two options to upgrade A9F18216 with earth leakage protection:

Option 1: MCB + Leakage Module Combination

Tipo de móduloModeloEspecificaçãoLarguraCódigo do pedido
QuickVigi iC602P 16A 30mA ACCompactar 1.5 módulos27milímetrosA9Q41216
Vigi iC602P 16A 30mA ACPadrão 3 módulos63milímetrosA9V41216
Vigi iC602P 16A 30mA ADetects pulsating DC leakage63milímetrosA9V42216

Option 2: Direct Replacement with RCBO

Schneider RCBO ModelDescriçãoCódigo do pedido
iC65N Vigi+ 2P C16A 30mA AIntegrated leakage protectionA9D11216
iC65N Vigi+ 2P C16A 30mA ACIntegrated leakage protectionA9D10216

A9F18216 is the standard 2P C16A model in the Schneider iC65N series with clear ordering information. The series covers various pole numbers and current ratings. Abundant Chinese domestic alternatives are available for flexible selection based on project budget and quality requirements. Earth leakage protection can be achieved by adding a leakage module or replacing with an RCBO to ensure safe and reliable electrical systems.

Full Model List of Schneider A9F18216 in the Same Series (Série iC65N)

  1. Model Coding Rule Explanation

The coding rule for A9F-prefixed order codes of Schneider iC65N series MCBs is as follows:

Parte do códigoSignificado
A9FProduct category: Acti9 iC65 MCB
17Type B curve (instantaneous trip at 2–5×In)
18Curva tipo C (instantaneous trip at 5–10×In, standard for lighting & distribuição)
19Curva tipo D (instantaneous trip at 10–14×In, for motor loads)
1/2/3/4Número de pólos: 1=1P, 2=2P, 3=3P, 4=4P
01/02/04/06…63Corrente nominal: 1UM, 2UM, 4UM, 6UM…63UM
  1. Lista completa de modelos (By Pole Number)

2.1 1P Models (A9F[17/18/19]1xx)

Corrente nominalTipo B (A9F171xx)Tipo C (A9F181xx)Tipo D (A9F191xx)
1UMA9F17101A9F18101A9F19101
2UMA9F17102A9F18102A9F19102
4UMA9F17104A9F18104A9F19104
6UMA9F17106A9F18106A9F19106
8UMA9F17108A9F18108A9F19108
10UMA9F17110A9F18110A9F19110
13UMA9F17113A9F18113A9F19113
16UMA9F17116A9F18116A9F19116
20UMA9F17120A9F18120A9F19120
25UMA9F17125A9F18125A9F19125
32UMA9F17132A9F18132A9F19132
40UMA9F17140A9F18140A9F19140
50UMA9F17150A9F18150A9F19150
63UMA9F17163A9F18163A9F19163

2.2 2P Models (A9F[17/18/19]2xx)

Corrente nominalTipo B (A9F172xx)Tipo C (A9F182xx)Tipo D (A9F192xx)
1UMA9F17201A9F18201A9F19201
2UMA9F17202A9F18202A9F19202
4UMA9F17204A9F18204A9F19204
6UMA9F17206A9F18206A9F19206
8UMA9F17208A9F18208A9F19208
10UMA9F17210A9F18210A9F19210
13UMA9F17213A9F18213A9F19213
16UMA9F17216A9F18216A9F19216
20UMA9F17220A9F18220A9F19220
25UMA9F17225A9F18225A9F19225
32UMA9F17232A9F18232A9F19232
40UMA9F17240A9F18240A9F19240
50UMA9F17250A9F18250A9F19250
63UMA9F17263A9F18263A9F19263

2.3 3P Models (A9F[17/18/19]3xx)

Corrente nominalTipo B (A9F173xx)Tipo C (A9F183xx)Tipo D (A9F193xx)
1UMA9F17301A9F18301A9F19301
2UMA9F17302A9F18302A9F19302
4UMA9F17304A9F18304A9F19304
6UMA9F17306A9F18306A9F19306
8UMA9F17308A9F18308A9F19308
10UMA9F17310A9F18310A9F19310
13UMA9F17313A9F18313A9F19313
16UMA9F17316A9F18316A9F19316
20UMA9F17320A9F18320A9F19320
25UMA9F17325A9F18325A9F19325
32UMA9F17332A9F18332A9F19332
40UMA9F17340A9F18340A9F19340
50UMA9F17350A9F18350A9F19350
63UMA9F17363A9F18363A9F19363

2.4 4P Models (A9F[17/18/19]4xx)

Corrente nominalTipo B (A9F174xx)Tipo C (A9F184xx)Tipo D (A9F194xx)
1UMA9F17401A9F18401A9F19401
2UMA9F17402A9F18402A9F19402
4UMA9F17404A9F18404A9F19404
6UMA9F17406A9F18406A9F19406
8UMA9F17408A9F18408A9F19408
10UMA9F17410A9F18410A9F19410
13UMA9F17413A9F18413A9F19413
16UMA9F17416A9F18416A9F19416
20UMA9F17420A9F18420A9F19420
25UMA9F17425A9F18425A9F19425
32UMA9F17432A9F18432A9F19432
40UMA9F17440A9F18440A9F19440
50UMA9F17450A9F18450A9F19450
63UMA9F17463A9F18463A9F19463
  1. Versões Especiais (Quebrando Capacidade / Expansão de função)
ModeloDescriçãoCódigo do pedidoObservações
iC65H 2P C16AHigh breaking capacity 10kAA9F18216HH = High breaking
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216LL = Low breaking
iC65N 2P C16A RWith overload alarm contactA9F18216RR = With alarm contact
iC65N 2P C16A DCFor DC circuits onlyA9F18216DCFor DC system protection
  1. Unified Key Technical Specifications

All A9F-prefixed iC65N models share the following core parameters:

Capacidade de ruptura (UTI): 6o (400V e)

Tensão nominal: 230/400V e

Freqüência: 50/60Hz

Dimensões: 1P=1 module (18milímetros), 2P=2 modules (36milímetros), 3P=3 modules (54milímetros), 4P=4 modules (72milímetros)

Montagem: Montagem em trilho DIN

Grau de Proteção: IP20

Tripping type: Termomagnético (sobrecarga: bimetal strip; curto-circuito: magnetic coil)

Applicable standards: CEI 60898-1, GB 14048.2

  1. Guia de seleção
  2. Tripping Curve Selection

Tipo B: For pure resistive loads (por exemplo, lâmpadas incandescentes)

Tipo C: For general power and lighting loads (mais comumente usado)

Tipo D: For inductive loads such as motors and transformers

  1. Seleção do número do pólo

1P: Protects line only, for single-phase lighting circuits

2P: Protects line + neutro, for single-phase socket circuits

3P: Protects three phases, for three-phase power circuits

4P: Protects three phases + neutro, para sistemas trifásicos de quatro fios

  1. Seleção de Capacidade de Quebra

Tipo N (6o): For general residential and commercial buildings

Tipo H (10o): For industrial sites or distribution systems near transformers

Tipo L (4.5o): For simple lighting systems