LUTRON VB-8200 Portable Vibration Meter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

LUTRON VB-8200 Portable Vibration Meter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

medidor de eletricidade/

LUTRON VB-8200 Portable Vibration Meter

Marca: LUTRON, Taiwan LUTRON VB-8200 User Manual PDF It is a handheld industrial vibration meter for equipment inspection, vibration severity measurement of motors, bombas e ventiladores. It only measures vibration velocity and acceleration, without displacement measurement (VB-8220 is the version with displacement function). ✅ Core Functions Measurement: Vibration velocity and vibration acceleration; supports RMS (Root ...

  • Detalhes do produto

Marca: LUTRON, Taiwan

LUTRON VB-8200 User Manual PDF

It is a handheld industrial vibration meter for equipment inspection, vibration severity measurement of motores, bombas e ventiladores. It only measures vibration velocity and acceleration, without displacement measurement (VB-8220 is the version with displacement function).

✅ Funções principais

  1. Medição: Vibration velocity and vibration acceleration; supports RMS (Root Mean Square) and Peak reading.
  2. Reading functions: Data Hold, Máximo / Minimum value recording.
  3. Comunicação: Isolated RS232 serial output, compatible with host computer software for data acquisition and recording.
  4. Large LCD display, low battery indicator and auto power-off.
  5. Separated piezoelectric vibration probe, supplied with magnetic base for easy attachment to equipment housing for measurement.
  6. Complies with ISO 2954 for vibration transducers, used for equipment vibration severity assessment per ISO 2372.

📋 Technical Specifications

ItemParâmetro
Vibration Velocity Range0.5 ~ 199.9 mm/s (escala completa 200 mm/s)
Acceleration Range0.5 ~ 199.9 m/s² (escala completa 200 m/s²)
Resposta de frequência10 Hz ~ 1 kHz
Sampling TimeAprox.. 1 segundo
Ambiente Operacional0~50℃, humidity <80%RH
Fonte de energia9V battery (006P/PP3)
Peso230g (excluding probe), probe: 38g
CertificaçõesISO9001, CE, IEC1010

🛠️ Typical Applications

Routine inspection of rotating machinery: motores, bombas centrífugas, fãs, gearboxes, compressores de ar

Preliminary screening of faults: rotor unbalance, desalinhamento, bearing looseness, foundation looseness

Factory predictive maintenance, equipment acceptance, vibration severity classification (ISO2372)

Laboratory and factory outgoing simple vibration testing

📦 Standard Accessories

Unidade principal, separated vibration sensor, magnetic mounting base, 9V battery, hard carrying case. Host computer acquisition software is optional.

⚠️ Model Differentiation (Easily Confused Models)

VB-8200: Velocity + Acceleration, no displacement, RS232

VB-8220: Velocity + Acceleration + Peak-to-Peak displacement (2mm p-p)

VB-8212: Upgraded version, some versions with temperature measurement

📌 Operation Notes

  1. Magnetic base is suitable for flat metal surfaces; use probe tip contact measurement for rough surfaces.
  2. Lower frequency limit at 10Hz, not suitable for low-frequency large-displacement equipment (por exemplo. large steam turbines). Low-frequency measurement requires dedicated low-frequency vibration meters.
  3. Only for simple inspection and severity evaluation. Spectrum analysis and bearing envelope demodulation require professional vibration analyzers (not this unit).

❗ Common Troubleshooting

  1. Fluctuating readings: Broken probe cable, poor contact of magnetic base, rusted measuring surface.
  2. Zero reading: Damaged probe or loose probe connector.
  3. Failed PC data upload: RS232-to-USB driver fault, mismatched communication parameters.
  4. Low battery warning: Insufficient battery voltage leads to degraded reading accuracy.

Referência de seleção alternativa

Alternativas domésticas: Anbo VBT series, VM series vibration meters.

Equivalentes importados: BK, IMV portable vibration meters.

Core Application of LUTRON VB-8200 Vibration Meter

Resumo: Handheld simple vibration measuring instrument, used to measure vibration severity of rotating machinery for routine predictive maintenance, judge whether equipment vibration exceeds threshold and screen early faults.

Measurable Physical Quantities

Vibration Velocity VEL: mm/s (mais comumente usado; ISO2372 equipment rating uses this parameter)

Vibration Acceleration ACC: m/s²

Reading modes: RMS / Pico; with max/min recording and data hold

❗No support for vibration displacement, spectrum analysis, demodulation or time-domain waveform. Cannot perform precision fault diagnosis; only severity evaluation.

Main Measurement Objects (Factory Inspection)

Motores, bombas centrífugas, fãs, ventiladores de torre de resfriamento, redutores de engrenagem, compressores de ar

Small rotating production equipment

Types of Faults for Preliminary Screening (Qualitative)

  1. Rotor unbalance: Uneven mass of rotating parts causing high vibration
  2. Misalignment: Coupling misalignment between motor and pump
  3. Bearing deterioration: Bearing wear leads to vibration increase (only detects higher vibration level; cannot identify specific bearing fault type)
  4. Loose anchor / fundação, insufficient housing rigidity
  5. Imbalance caused by fouling and deposit buildup on blades or impellers

Typical Working Scenarios

  1. Routine equipment inspection: Inspectors measure vibration at fixed measuring points periodically, record values and compare historical data to monitor vibration rising trend.
  2. Novo equipamento / overhaul acceptance: Measure vibration after equipment maintenance and judge compliance against ISO2372 standard.
  3. Preliminary fault screening: Rapid vibration measurement when abnormal noise occurs to assess vibration severity. If vibration exceeds limit, use professional vibration analyzer for further spectrum diagnosis.
  4. Registro de dados: Built-in RS232 serial port connects to PC for vibration data collection and inspection report generation.

Limitações (Critical for Avoiding Misuse)

  1. Faixa de frequência: 10Hz ~ 1kHz, not applicable to low-frequency large units (steam turbines, large low-speed motors)
  2. Only severity measurement, no spectrum function to distinguish fault types. It only tells you “vibration is high”, and cannot easily tell whether it is unbalance or bearing failure.
  3. Not suitable for high-frequency impact measurement of precision bearings (no envelope demodulation function).
  4. Only measures casing surface vibration, not shaft vibration (shaft vibration requires eddy current probes).

Simple Example

For a water pump, measure vibration velocity at bearing position weekly.

ISO2372 standard: Within 10mm/s = Good; above 11.2mm/s requires monitored attention; above 18mm/s is dangerous and equipment shall be shut down for maintenance. VB-8200 reads this mm/s value.

Full Model List of LUTRON VB-82xx Series Vibration Meters

Mesma série (VB82xx inspection vibration meters, 10Hz~1kHz, separated piezoelectric probe, ISO2954). VB-8200 is the base model. Models differ by measurement parameters, data storage and channel count.

ModeloMeasurable ParametersPrincipais recursosPosicionamento
VB‑8200Vibration velocity, aceleraçãoModelo básico; RS232; no displacement; MAX/MIN, HOLD; no SD cardRoutine equipment inspection (your selected model)
VB‑8201HAVibration velocity, aceleraçãoSimplified VB‑8200, funções semelhantes, slight housing difference, RS232 outputEconomical inspection
VB‑8220Velocity, aceleração, peak-to-peak displacementUpgraded from VB‑8200 with displacement measurement; optional RS232Inspection when displacement reading is required
VB‑8210Velocity, aceleraçãoSame hardware as VB‑8200, panel/firmware fine-tuning, supports imperial unit, RS232Export version for overseas market
VB‑8212Velocity, aceleração, some versions with temperatureEarly old model, limited stock in market, gradually replacedSpare parts for legacy projects
VB‑8206SDVelocity, aceleração, displacement; SD card local storageBacklit LCD, auto data logging with adjustable sampling interval, RS232Long-term on-site data acquisition without continuous PC connection
VB‑8230SDVelocity, aceleração, displacement; Dual channelTwo probes simultaneous acquisition, SD card logging, dual-channel comparison measurementComparative test of bearing ends / motor-pump alignment
BVB‑8207SDVelocity, aceleração, displacement; Four channel4-channel vibration probe simultaneous measurement; SD card + RS232/USB; larger main unitMulti-point synchronous acquisition for unit inspection
PVB‑820Velocity, aceleraçãoPen-type integrated vibration meter, built-in probe without separated sensor, quick simple screeningSimple handheld pen-style inspection
VT‑8204Velocity, aceleraçãoBasic integrated vibration meter, no separated probe, low-cost entry modelQuick simple vibration measurement

Sensores compatíveis (Interchangeable within Series)

VB-83: Standard piezoelectric probe for VB82xx series, equipped with magnetic base, BNC connector. Interchangeable on VB-8200 / VB-8206SD / BVB-8207SD and other models.

✅ Diretrizes de seleção rápida

  1. Displacement required? VB-8200/8201HA/8210/PVB820: no displacement; 8220, 8206SD, 8230SD, BVB-8207SD support displacement.
  2. SD local storage required? Models with suffix SD support SD card logging; models without SD only support real-time online acquisition via RS232.
  3. Quantidade de canais: Single channel: 8200/8220/8206SD; Dual channel: 8230SD; Four channel: BVB-8207SD.
  4. Integrated vs Separated probe: PVB-820, VT-8204: integrated probe; all other VB-82xx: separated BNC probe.

❗Notice

All models in this series only measure vibration severity, without spectrum / envelope demodulation, and cannot perform spectrum-based fault diagnosis.

Uniform frequency response: 10Hz–1kHz, not suitable for low-frequency large units.

VB-82xx series: portable vibration meter, NOT vibration analyzer.

Tabela de comparação: LUTRON VB-8200 / VB-8220 / VB-8206SD

Posicionamento: Portable inspection vibration meters of LUTRON VB-82xx series. No spectrum analysis, vibration severity measurement only. Uniform frequency response: 10Hz~1kHz. Supplied with VB-83 separated piezoelectric probe + magnetic base, BNC interface.

ItemVB‑8200VB‑8220VB‑8206SD
Measurable ParametersVibration Velocity VEL, Acceleration ACCVibration Velocity VEL, Acceleration ACC, Peak-to-Peak Displacement (p-p)Vibration Velocity VEL, Acceleration ACC, Peak-to-Peak Displacement (p-p)
RMS / PicoRMS / PicoRMS / Pico
Data StorageNo local storageNo local storageSD card local storage, auto logging with adjustable sampling interval; offline acquisition supported
Only temporary MAX/MIN record and HOLDOnly temporary MAX/MIN record and HOLD
Interface de comunicaçãoPorta serial RS232 (real-time upload to PC)Porta serial RS232 (real-time upload to PC)Porta serial RS232 + SD card dual mode; data export to PC
MostrarStandard LCDStandard LCDBacklit LCD, available for low-light environment
Principais vantagensModelo básico, econômico; leve, spare parts easy to sourceAdds displacement measurement based on VB‑8200; displacement reading available for maintenanceSD card for long-term auto logging, continuous monitoring without permanent PC connection
Typical PurposeRoutine factory predictive maintenance inspection, periodic check, overhaul acceptance (vibration severity evaluation by mm/s per ISO2372)Motor / pump overhaul, cases requiring both velocity and displacement, simple vibration severity assessmentContinuous monitoring during equipment commissioning, fault trend tracking, raw data archiving
DesvantagensNo displacement, no SD card; only on-site reading or real-time online acquisitionNo SD card; only on-site reading or online acquisitionPreço mais alto; SD card needs regular backup
Cenários de aplicação recomendadosMost factory conventional predictive maintenance inspectionEquipment overhaul, coupling alignment inspection, when reports require displacement dataContinuous monitoring during equipment commissioning, fault trend tracking, raw data retention
Selection ConclusionPreferred option if only vibration severity (mm/s) é necessárioSelect when peak-to-peak displacement is required in reportsSelect when long-term auto logging and offline data storage are required

Notas Suplementares

  1. All three models cannot perform spectrum analysis or envelope demodulation. They only read vibration magnitude and cannot distinguish unbalance, misalignment or bearing faults. Professional vibration analyzer is required for further diagnosis once vibration exceeds limit.
  2. VB-83 probe is interchangeable among the three main units, magnetic base compatible.
  3. Fonte de energia: All use 9V PP3 battery.