The Moxa NPort 5210A is an industrial-grade 2-port RS-232 serial device server that enables serial device networking via Ethernet. Possui ampla operação de temperatura (0~60°C), proteção de nível industrial (surto/isolado/ESD), redundância de energia dupla e configuração flexível. It is widely applied in manufacturing, energia, transportation and other industries. Its compact structure and diverse mounting methods make it an ...

  • Detalhes do produto

The Moxa NPort 5210A is an industrial-grade 2-port RS-232 serial device server that enables serial device networking via Ethernet. Possui ampla operação de temperatura (0~60°C), proteção de nível industrial (surto/isolado/ESD), redundância de energia dupla e configuração flexível. It is widely applied in manufacturing, energia, transportation and other industries. Its compact structure and diverse mounting methods make it an ideal choice for upgrading legacy serial devices. Following maintenance guidelines and troubleshooting manuals ensures long-term stable operation and reduces system maintenance costs.

  1. Definição de código de modelo
Segmento de modeloSignificadoDescrição
NPortSérie de produtosProduct line identifier for Moxa serial device servers
52Código da série5200A series, stands for 2-port industrial serial server
10Serial Port Type10 = RS-232 interface; 30 = RS-422/485; 50 = RS-232/422/485 triple-in-one
UMVersion MarkEnhanced version with wider operating temperature range (0~60°C vs original 0~55°C) and upgraded protection level
-TOptional SuffixWide-temperature model, operating temperature extended to -40~75°C
  1. Tabela de especificações principais
CategoriaEspecificaçõesObservações
Configuração Básica2-port RS-232 serial serverSupports serial device networking and RS-232 to Ethernet communication
1×10/100BaseT(X) RJ45 Ethernet port
DB9 male serial connector
Serial PerformanceMax Baud Rate: 921.6 kbpsCompatible with most industrial serial devices
Data Bits: 5,6,7,8
Parity: Nenhum, Even, Odd, Espaço, Mark
Stop Bits: 1, 1.5, 2
Flow Control: RTS/CTS, XON/XOFF
Network FunctionsOperation Modes: TCP Server, TCP Client, UDP, Real COM, Reverse Telnet, RFC2217Adaptable to various industrial application scenarios
Protocolos Suportados: PI, TCP, UDP, ARP, ICMP, DHCP, BOOTP, HTTP, Telnet, SNMP
Electrical ProtectionSerial Surge Protection: 0.5 kVIndustrial protection for harsh electromagnetic environments
Ethernet Port Isolation: 1.5 kV built-in magnetic isolation
Proteção ESD: Contato 8 kV, Ar 15 kV
Power FeaturesDual DC Input: 12~48 VDC (24 VDC recommended)Redundant power design for stable operation
Interface de energia: Screw-type connector + terminal block
Max Power Consumption: 3.6 C
Propriedades FísicasDimensões: 77 × 111 × 26 milímetrosCompact design for diverse installation sites
Peso: 340 g
Montagem: Desktop, DIN-rail (optional kit), Wall-mount
Parâmetros AmbientaisTemperatura operacional: Standard 0~60°C, Wide Temp -40~75°CExcellent industrial environmental adaptability
Temperatura de armazenamento: -40~75°C
Umidade relativa: 5~95% (sem condensação)
Vibração: 5~500 Hz, 1.5 g
Choque: 10 g, 11 EM
CertificaçõesCE, FCC, UL/cUL, Class I Division 2Complies with international industrial standards, applicable in hazardous areas
Ordering CodeNPort 5210ADistinguish standard and wide-temperature models
NPort 5210A-T (Wide Temperature)

III. Full Series Model List (NPort 5200A Series)

ModeloSerial Port TypeFaixa de temperaturaPrincipais recursos
NPort 5210A2-Port RS-2320~60°CBasic model for RS-232 serial connection
NPort 5210A-T2-Port RS-232-40~75°CWide-temperature model for extreme temperature environments
NPort 5230A2-Port RS-422/4850~60°CDifferential serial port for long-distance communication
NPort 5230A-T2-Port RS-422/485-40~75°CWide-temperature RS-422/485 serial server
NPort 5250A2-Port RS-232/422/4850~60°CTriple-in-one serial port for flexible device matching
NPort 5250A-T2-Port RS-232/422/485-40~75°CWide-temperature triple-in-one serial server
  1. Replacement Comparison: Old & New Models / Peer Products
  2. Old & Substituição de novo modelo
Modelo AntigoNovo modeloMajor Upgrades
NPort 5210NPort 5210AExtended operating temp to 0~60°C; enhanced surge protection; dual power input; simplified web configuration
  1. Peer Product Comparison
ModeloMarcaQuantidade de portasSerial TypeTemp RangeNível de proteçãoFaixa de preço
NPort 5210AMoxa2RS-2320~60°CSerial 0.5kV surge, Ethernet 1.5kV isolation$260~$300
EKI-1521Advantech2RS-2320~60°CSerial 1kV surge, Ethernet 1.5kV isolation$240~$280
IES-202Contato Fênix2RS-232-20~60°CSerial 0.5kV surge, Ethernet 1kV isolation$280~$320
UNO-2170Advantech2RS-232/4850~55°CSerial 0.5kV surge, Ethernet 1.5kV isolation$220~$260
  1. Application Environments & Industry Cases
  2. Cenários Aplicáveis

Indústria de transformação: Networking for PLC, Máquinas-ferramentas CNC, barcode scanners and industrial test equipment

Energia & Utilitários: Integration of power meters, RTU and SCADA systems

Óleo & Gas Industry: Remote management of serial devices

Smart Infrastructure: Automação predial, monitoring system and IoT integration

Transporte: Rail transit signal equipment and vehicle monitoring system

Equipamento Médico: Networking for laboratory instruments and medical diagnostic devices

  1. Non-recommended Scenarios

High humidity environment (relative humidity over 95%, condensing condition)

Severe chemical corrosion environment without special anti-corrosion coating

Underwater or high-pressure occasions (non-waterproof design, only for dry indoor/covered outdoor use)

POE power supply required (NPort 5210A does not support POE, separate power supply needed)

  1. Casos de aplicação típicos

Caso 1: PLC Networking for Automotive Production Lines

Aplicativo: Connect legacy PLC RS-232 ports to Ethernet for remote monitoring and programming

Configuração: Adopt Real COM mode to create virtual serial ports on PC, no modification needed for original PLC software

Vantagem: Realize Industry 4.0 upgrade without replacing expensive PLCs, cut costs by 70%

Caso 2: Smart Grid Meter Data Collection

Aplicativo: Gather data from distributed RS-232 power meters to SCADA system via NPort 5210A

Configuração: TCP Server mode, central server collects meter data through Ethernet

Vantagem: Realize remote meter reading and real-time monitoring, reduce manual inspection cost and improve data accuracy

  1. Falhas Comuns & Soluções
Fenômeno de falhaPossíveis causasSoluções
Unable to access Web configuration page1. Different IP network segment1. Adjust IP address, use Moxa IP Search Tool
2. Firewall interception2. Disable firewall or add access rules
3. Abnormal power supply3. Check power indicators and dual power connection
Fail to open virtual COM port by application1. Incorrect COM mapping configuration1. Reconfigure Real COM mode
2. Network disconnection2. Ping device IP to check network connectivity
3. Driver installation failure3. Reinstall official latest drivers
Unstable serial communication1. Mismatched baud rate & parity1. Unify serial parameters with terminal devices
2. Electromagnetic interference2. Use shielded cables, keep over 30cm away from power cables
3. Overlong or poor-quality serial cables3. Replace qualified cables within 15m length
Flashing power indicator1. Unstable input voltage1. Ensure input voltage within 12~48VDC
2. Power module failure2. Replace spare power module
3. Internal short circuit3. Contact Moxa technical support for maintenance
Network disconnection1. Defective network cable1. Replace network cable for test
2. Faulty switch port2. Change switch port
3. Damaged Ethernet port3. Check port indicators, send for repair if abnormal

VII. Replaceability Analysis of Core Components

ComponenteReplaceabilityOperation DifficultyRequired ToolsNotas
Módulo de potênciaAlto (External)BaixoChave de fendaPower off in advance, use 12~48VDC standard power supply
Serial ConnectorMédioMédioSoldering iron, solder wireProfessional welding skills required, anti-static operation
Ethernet Port ConnectorMédioMédioSoldering iron, solder wireHighly integrated with mainboard, professional maintenance recommended
MainboardBaixoAltoFull set of electronic maintenance toolsHigh replacement cost, whole device replacement preferred
Heat SinkAltoBaixoChave de fendaFix firmly and apply thermal grease evenly
Luz IndicadoraMédioMédioSoldering iron, solder wireSMD component, fine operation required

VIII. Manutenção Diária & Prevention Guidelines

  1. Instalação & Regras de fiação

Prioritize dual redundant power supply, fasten screw connectors tightly

Keep serial cables at least 30cm away from power cables to reduce EMI

Ensure reliable equipment grounding with grounding resistance below 4Ω

  1. Cronograma de manutenção regular
Item de manutençãoCycleOperation Content
Atualização de FirmwareTrimestralUpdate to latest stable firmware to fix security vulnerabilities
Dust CleaningSemi-annuallyClean surface and vents with compressed air after power off
Connection InspectionMensalCheck looseness of all wiring especially power and network lines
Operation MonitoringWeeklyCheck running status, temperature and communication statistics via Web page
Configuration BackupAfter every modificationExport configuration file to avoid data loss
  1. Fault Prevention Measures

Avoid placing devices under extreme temperature, humidity and dusty conditions

Install surge protector at power input terminal against voltage surge damage

Enable IP filtering and strong passwords for network access restriction

Adopt dual-device redundancy for core applications to enhance system reliability

  1. Air Freight Compliance & Certificações
  2. Air Freight Compliance

No built-in lithium battery, compliant with IATA dangerous goods regulations, deliverable as general cargo

Use original packaging or anti-static packaging meeting transportation standards

Mark FRAGILE label to avoid heavy pressure and violent vibration

  1. Documentos de Certificação
CertificaçãoPadrãoEscopo de aplicação
CEEM 55032/24 (EMC), CEI 61000-4 série (EMS)European market access
FCCPart 15BNorth American market access
UL/cULUL 61010-1North American safety approval
Class I Division 2ANSI/ISA 12.12.01Approval for hazardous location deployment
  1. Selection Rules & Quick Memorization

Regras de seleção rápida

  1. Port definition: 10=RS-232, 30=RS-422/485, 50=triple-in-one
  2. Faixa de temperatura: Standard 0~60°C, -T version -40~75°C
  3. Protection standard: Serial 0.5kV surge, Ethernet 1.5kV isolation, ESD 15kV
  4. Power specification: 12~48VDC dual input with screw terminal & block interface