OMRON E3T-ST23M Photoelectric Sensor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

OMRON E3T-ST23M Photoelectric Sensor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

OMRON E3T-ST23M Photoelectric Sensor

Detalhamento do código do modelo (E3T-ST23M with 2M Cable) Segment Definition E3T Series of ultra-miniature thin built-in amplifier photoelectric sensors ST Through-beam opposed type 2 Body size specification, 300 mm sensing distance model 3 Output logic: PNP Light-ON M M3 threaded mounting holes (models without M adopt M2 mounting) 2M Standard 2-meter outgoing cable Split components sold as ...

  • Detalhes do produto

Detalhamento do código do modelo (E3T-ST23M with 2M Cable)

SegmentoDefinição
E3TSeries of ultra-miniature thin built-in amplifier sensores fotoelétricos
STThrough-beam opposed type
2Body size specification, 300 mm sensing distance model
3Output logic: PNP Light-ON
MM3 threaded mounting holes (models without M adopt M2 mounting)
2MStandard 2-meter outgoing cable

Split components sold as a complete set: Emitter E3T-ST23-L, Receiver E3T-ST23-D

  1. Core Basic Specifications
  2. Optical Performance

Sensing method: Through-beam opposed type (paired emitter + receiver)

Rated sensing distance: 300 milímetros

Light source: 650 nm visible red LED

Minimum detectable object: φ2 mm opaque solid object

Beam angle: Transmitting 2°~20°, Receiving 2°~70°

Tempo de resposta: 1 EM

Indicadores: Orange operation indicator, green stability margin indicator

  1. Elétrica Especificações

Tensão de alimentação: 12~24 V DC ±10%, peak-to-peak ripple ≤10%

Current consumption: Emitter ≤10 mA, Receiver ≤20 mA

Tipo de saída: PNP open collector

Modo de operação: Luz acesa (output turns ON when light is received)

Load rating: Máx.. 50 mA, load voltage ≤26.4 V DC

Residual voltage: ≤2 V for 10~50 mA load; ≤1 V for load below 10 mA

Funções de proteção: Reverse polarity protection, output short-circuit protection, mutual interference suppression

  1. Mecânico & Especificações Ambientais

Montagem: Fixed with M3 screws (mounting screws not included, para ser adquirido separadamente)

Ingress protection class: IP67

Housing material: Plástico de engenharia PBT

Cable outlet: 2 m 4-core straight cable

Weight per set: Aprox.. 20 g

Temperatura operacional: -25 ℃ ~ +55 ℃ (sem condensação)

Certificações: CE, RoHS, UL

III. Wiring Definition (4-cabo central, receiver side)

  1. Marrom: DC12~24 V positive (+)
  2. Azul: 0 V negative (GND)
  3. Preto: PNP signal output (connect load positive to black wire, load negative to 0 V)
  4. Branco: Não utilizado (empty pin)

The emitter only has 2 fios: Marrom (+), Azul (GND), without signal output wire.

  1. Output Logic Description
  2. Luz acesa (este modelo)

No obstruction, light path unblocked → Output ON (high level on black wire)

Object blocks light path → Output OFF

  1. Cross-series reference: E3T-ST24M is PNP Dark-ON with identical 300 mm distância de detecção
  2. Cenários típicos de aplicação
  3. Presence detection & counting of materials on small production lines
  4. Transmittance detection for terminals, tiny parts and thin materials (minimum φ2 mm detectable)
  5. Installation in narrow equipment spaces (ultra-thin compact body)
  6. Embalagem, 3C automation, lithium battery equipment, small conveyor lines
  7. Position limit detection, blanking presence detection
  8. Alternative Selection Reference within the Same Series
ModeloSaídaModo de operaçãoMounting HoleDistância de detecção
E3T-ST21MNPNLuz acesaM3300 milímetros
E3T-ST22MNPNDark-ONM3300 milímetros
E3T-ST23MPNPLuz acesaM3300 milímetros (Modelo Atual)
E3T-ST24MPNPDark-ONM3300 milímetros

VII. Instalação & Precauções de operação

  1. Emitter and receiver lenses must be coaxial aligned; misalignment will drastically reduce sensing margin
  2. Sensing margin curve: Only 2× margin at 300 milímetros; higher margin at short distances
  3. When multiple units are mounted side by side, stagger installation to avoid mutual interference
  4. Prohibit long-term oil stain and dust accumulation on lenses; clean lenses regularly
  5. Do not over-tighten M3 mounting screws to prevent housing cracking
  6. Load current shall not exceed 50 mA; direct driving of high-power solenoid valves is forbidden

OMRON E3T-ST23M Detection Accuracy / Minimum Detectable Object Specifications

  1. Objeto Mínimo Detectável (Core Accuracy Index)

Official specification: φ2 mm opaque solid object

Under standard light path at rated 300 mm distância de detecção, opaque objects with diameter ≥2 mm can trigger the sensor stably.

Theoretical occlusion ratio: 2 mm blocks the beam, corresponding accuracy of approx. 0.67% relative to effective beam diameter

  1. Beam Spot Size (Affects Fine Detection Accuracy)

Transmitting divergence angle: 2°~20°, spot diameter approx. 6~8 mm at 300 mm distância de detecção

Light intensity peaks at the spot center with reduced edge sensitivity; tiny workpieces smaller than 2 mm will be missed

  1. Repeat Positioning Accuracy (Switch Repeat Error)

Tempo de resposta 1 ms with zero mechanical clearance inside the photoelectric sensor; electrical repeatability:

Trigger repeat error <0.01 mm (stable static detection)

Under high-speed dynamic conveying conditions, accuracy is determined by conveying speed; no inherent lag error from the sensor itself

  1. Edge Fine Detection Explanation
  2. Only suitable for presence detection, counting and position limit control, not for high-precision dimensional measurement;
  3. This model lacks sufficient accuracy for detecting tiny 0.5~1 mm parts; select E3T-SL series narrow-beam through-beam or fiber optic sensors instead;
  4. Thin transparent films and semi-transparent materials: O 2 mm standard does not apply, unstable detection will occur for light-transmitting workpieces.
  5. Accuracy Limitations in Application

Misalignment error: Offset over 1 mm between emitter and receiver enlarges effective detectable diameter and degrades accuracy;

Dust and lens dirt equivalently expand the spot size, increasing minimum detectable dimension and worsening accuracy;

300 mm maximum sensing distance is the extreme operating condition; shorter distances (50~150 mm) deliver smaller spot size and better practical accuracy, enabling stable detection of workpieces close to 1.5 milímetros.

 

Nominal minimum detection accuracy: 2 mm objeto opaco (padrão 300 distância mm)

Accuracy can be improved to approx. 1.5 mm with short-distance mounting;

Not applicable for micron-level dimensional measurement; only for workpiece presence detection.

Full Sensing Distance Specifications of OMRON E3T-ST23M

  1. Rated Standard Sensing Distance (Official Nominal Value)

300 milímetros (0.3 eu)

It belongs to short-range through-beam type in E3T-ST2 series; dígito “2” in model code represents 300 mm specification.

  1. Valid Operating Range

Minimum installable distance: 5 milímetros (emitter and receiver cannot be tightly attached to avoid light path saturation)

Standard rated distance: 300 milímetros (optimal design installation distance with green stability indicator steadily lit)

Maximum detectable limit: Light margin decays rapidly beyond 300 milímetros; installation over 400 mm is highly susceptible to interference from dust, misalignment and vibration, long-term use is not recommended

Curve Description:

Only approx. 2× stability margin at 300 milímetros, just meeting the lower limit of stable detection;

Sufficient margin within 0~200 mm short range, delivering stronger anti-interference and anti-offset performance.

  1. Sensing Distance Classification for Same-Series Through-Beam Models (Referência de seleção rápida)
Série de modelosDistância de detecção nominal
E3T-ST1□M100 milímetros
E3T-ST2□M (including ST23M)300 milímetros
E3T-ST3□M2000 milímetros (2 eu)
  1. Distance Application Notes
  2. 300 mm is the rated maximum limit; prioritize installation at 50~200 mm on-site for drastically improved detection stability;
  3. Shorten installation distance for scenarios with multiple side-by-side sensors, heavy dust environment or severe equipment vibration;
  4. Installation beyond 300 mm causes missed detection of tiny φ2 mm workpieces and increases the minimum detectable dimension.

Temperature Specifications of OMRON E3T-ST23M (Official Datasheet)

  1. Temperatura operacional (Powered Running)

-25 ℃ ~ +55 ℃

Constraints: Environment free of icing and condensation; frost or condensation will cause lens light path failure and internal circuit short-circuit damage.

  1. Armazenar / Temperatura de transporte (Power Off)

-40 ℃ ~ +70 ℃

Storage under icing or condensation environments is also prohibited.

Supporting Humidity Reference

Operating humidity: 35%~85% RH (sem condensação)

Storage humidity: 35%~95% UR (sem condensação)

On-Site Usage Notes

  1. For high-temperature operating conditions (>50 ℃), shorten sensing distance and reduce load current to avoid thermal drift of the sensor;
  2. Under low-temperature conditions (<-20 ℃), avoid rapid cold-hot alternation of equipment to prevent lens frosting;
  3. Long-term use of this model is not recommended near heating furnaces and ovens with high ambient temperatures; dedicated high-temperature resistant photoelectric sensors shall be adopted instead.

Translation Standard Note

All terminology follows Omron global official datasheet industrial English standards, unified international photoelectric sensor industry vocabulary, consistent with European & American automation equipment documentation writing norms.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado