Definição de código de modelo
| Segmento | Código | Significado |
| G2R | – | Série de produtos: General-purpose Power Relay |
| 0.5 | – | Contact pole: 1-pole SPDT (10UM) / 2-pole DPDT (5UM) |
| -S | – | Tipo de terminal: Plug-in, matched with 8-pin socket |
| -N | – | Função: Built-in LED operation indicator |
| -D | – | Função: Built-in coil surge suppression diode (DC coil only) |
| -EU | – | Função: With lockable test button, manual actuation for circuit inspection |
| (S) | – | Extra function: Standard mechanical indicator and nameplate for model & purpose marking |
| DC24/AC220 | – | Rated coil voltage, specify upon order; AC and DC cannot be mixed |
Mnemonic Rule: G2R series includes 1/2 postes. SNDI integrates LED, freewheeling diode and test button. (S) equips mechanical indicator and nameplate. Select correct AC/DC voltage.
- Tabela de especificações principais (Modelo: G2R-2-SNDI DC24 (S))
| Categoria | Parâmetro | Observações |
| Especificações básicas | ||
| Relay Type | Plug-in miniature power relay | Compatível com IEC 61810-1 |
| Configuração de contato | 2c DPDT / 1c SPDT | 8 pins for 2-pole, 5 pins for 1-pole |
| Carga nominal | 2-pólo: 5A @ 250VAC / 5A @ 30VDC | Carga resistiva; derate for inductive load |
| 1-pólo: 10A @ 250VAC / 10A @ 30VDC | ||
| Inductive Load Capacity | 2-pólo: 2A @ 250VAC / 0.5A @ 30VDC | Fator de potência 0.4, L/R=7ms |
| 1-pólo: 7.5A @ 250VAC / 5A @ 30VDC | ||
| Max Switching Power | 2-pólo: 2500VA(AC) / 300C(CC) | |
| 1-pólo: 3000VA(AC) / 300C(CC) | ||
| Resistência de contato | ≤50mΩ (DC5V 1A voltage drop method) | Initial value |
| Parâmetros da bobina (CC24V) | ||
| Tensão nominal | CC24V | Allowable fluctuation: ±10% |
| Corrente nominal | 21.6mA | |
| Resistência da bobina | 1113Oh | Measured at 20°C |
| Coil Inductance | Aprox.. 3.6H | Reference value |
| Tensão de captação | ≤75% de tensão nominal (Max DC18V) | |
| Tensão de queda | ≥10% de tensão nominal (Min DC2.4V) | |
| Mecânico & Desempenho Elétrico | ||
| Tempo de operação | ≤15ms (excluding contact bounce) | |
| Hora de lançamento | ≤20ms (diode built-in type) | Standard type ≤10ms |
| Max Operation Frequency | Mecânico: 18,000 cycles/hour | |
| Elétrica: 1,800 cycles/hour under rated load | ||
| Resistência de Isolamento | ≥1000MΩ (DC500V megohmmeter) | Between coil and contact |
| Resistência Dielétrica | Coil to contact: 2000VAC 1min | 50/60Hz |
| Between contacts: 1000VAC 1min | ||
| Between coils: 500VAC 1min | ||
| Ambiental & Propriedades Físicas | ||
| Temperatura operacional | -40°C ~ +70°C | Sem condensação |
| Temperatura de armazenamento | -40°C ~ +85°C | |
| Umidade | 35% ~ 85% RH | Sem condensação |
| Peso | Aprox.. 20g | |
| Tipo de montagem | Matched with P2RF series sockets, recommended P2RF-08-PU Push-In Plus socket | 60% wiring time saved |
| Botão de teste | Lockable type (lockable at ON position) | Circuit inspection without power supply |
- Full Model List SNDI Type (G2R-□-S (S) Série)
3.1 1-pole Models (G2R-1-SNDI (S))
| Prefixo do modelo | Descrição da função | Tensão Opcional | Order Example |
| G2R-1-SNDI | Indicador LED + built-in diode + lockable test button | AC12/24/100/110/200/220V | G2R-1-SNDI DC24 (S) |
| DC6/12/24/48/100V | |||
| G2R-1-SNI | Indicador LED + lockable test button (no diode) | Igual ao acima | G2R-1-SNI AC220 (S) |
| G2R-1-SND | Indicador LED + built-in diode (no test button) | Igual ao acima | G2R-1-SND DC12 (S) |
| G2R-1-SN | Only LED indicator | Igual ao acima | G2R-1-SN AC110 (S) |
| G2R-1-S | Tipo padrão (no LED/diode/test button) | Igual ao acima | G2R-1-S DC48 (S) |
3.2 2-pole Models (G2R-2-SNDI (S))
| Prefixo do modelo | Descrição da função | Tensão Opcional | Order Example |
| G2R-2-SNDI | Indicador LED + built-in diode + lockable test button | AC12/24/100/110/200/220V | G2R-2-SNDI DC24 (S) |
| DC6/12/24/48/100V | |||
| G2R-2-SNI | Indicador LED + lockable test button (no diode) | Igual ao acima | G2R-2-SNI AC220 (S) |
| G2R-2-SND | Indicador LED + built-in diode (no test button) | Igual ao acima | G2R-2-SND DC12 (S) |
| G2R-2-SN | Only LED indicator | Igual ao acima | G2R-2-SN AC110 (S) |
| G2R-2-S | Tipo padrão (no LED/diode/test button) | Igual ao acima | G2R-2-S DC48 (S) |
3.3 Modelos Especiais
| Modelo | Função Especial | Aplicativo |
| G2R-2-SNDI-AP3 | AP3 certified, compliant with UL508 | Industrial control for North America |
| G2R-1-SNDI-G | Gold-plated contact | Low-level signal switching ≤100mA |
- Cross-brand Replacement List
| Omron Model | Marca Alternativa | Modelo de substituição | Principal diferença |
| G2R-2-SNDI DC24 (S) | Schneider | RXM2AB2BD + test button accessory | Extra test button needed, similar price |
| Siemens | 3RT1015-1BB42 + locking test unit | Larger dimension, different contact material | |
| ABB | CR-MX024DC2L + test module | Identical mounting, preço mais alto | |
| Weidmüller | DRM57024 + manual test switch | Different terminal design, external test function | |
| Domestic brand | YHRJ2S-CL DC24V + botão de teste | Econômico, consistent performance, optional test button | |
| G2R-1-SNDI DC24 (S) | Schneider | RXM4AB2BD + test accessory | 10A 1-pole capacity, extra test part required |
| Siemens | 3RT1016-1BB42 + test device | 12A 1-pole capacity, complete test function |
Sugestão de seleção: Prioritize Omron for integrated design. Choose domestic alternatives for cost control. Match original brand for system compatibility.
- Falhas Comuns & Soluções
| Fenômeno de falha | Possíveis causas | Soluções |
| Queima da bobina | 1. Mixed AC/DC voltage | 1. Verify AC/DC marking |
| 2. Voltage exceeds 卤10% rated value | 2. Keep voltage within rated range | |
| 3. Reversed DC coil polarity | 3. Wire per +/- terminal marking | |
| No contact actuation after power-on | 1. Test button locked at ON | 1. Switch test button to OFF |
| 2. Voltage lower than 75% valor nominal | 2. Raise voltage over 80% valor nominal | |
| 3. Mechanical jam & unreset button | 3. Confirm full reset of test button | |
| No response in manual test | 1. Botão de teste danificado | 1. Substitua o relé |
| 2. Mechanical blockage | 2. Check mounting and socket tightness | |
| 3. Soldagem por contato | 3. Replace relay and inspect overload | |
| LED off while relay operates | 1. Broken LED | 1. Substitua o relé |
| 2. Burnt current-limiting resistor | 2. Check circuit overcurrent | |
| 3. Reversed DC polarity | 3. Correct coil wiring polarity | |
| Failure to reset after power cut | 1. Locked ON test button | 1. Reset test button |
| 2. Residual coil voltage | 2. Add discharge circuit or replace coil | |
| 3. Soldagem por contato | 3. Replace relay and check load type |
Precauções: Reset test button properly. Do not mix AC and DC. Correct polarity wiring. Add absorption circuit for inductive load. Do not exceed rated current.
- Conformidade com frete aéreo & Certificações
6.1 Conformidade com frete aéreo
| Item | Status | Descrição |
| Built-in lithium battery/supercapacitor | Nenhum | Electromagnetic relay without energy storage components |
| Magnetic property | Weak magnetism | Compliant with IATA DGR Class 9 unrestricted goods |
| Shipping category | Carga geral | No UN number required |
| Embalagem | Standard anti-static package | Avoid impact to prevent component damage |
6.2 Certificações
| Certificate | Padrão | Compliance Status |
| CE | LVD 2014/35/EU + EMC 2014/30/EU | Compliant |
| RoHS | RoHS 2.0 10-substance restriction | Lead & cadmium free eco-design |
| UL | UL508 Industrial Control Equipment | Optional for partial models (-AP3 suffix) |
| CSA | C22.2 No.14 Canadian Standard | Synchronized with UL certification |
| CEI | CEI 61810-1 General Relay Standard | Compliant |
Export Notice: Provide CE & RoHS documents for EU market. Select UL/CSA certified models with -AP3 suffix for North America.
- Casos de aplicação & Industry Matching
7.1 Cenários típicos de aplicação
| Indústria | Aplicativo | Pontos-chave da seleção |
| Automação Industrial | PLC output expansion, drive solenoid valves, motores pequenos, contactor coils | DC24V G2R-2-SNDI(S) with P2RF-08-PU socket for convenient circuit test |
| Automação Predial | Controle de climatização, fã & water pump startup, controle de iluminação | AC220V G2R-1-SNDI(S), mechanical indicator for on-site maintenance |
| Equipment Manufacturing | Signal switching for test, medical and semiconductor devices | DC12V G2R-1-SNDI-G(S) gold-plated contact for reliable low-level signal |
| Indústria Energética | Control loop of solar inverter & UPS | DC48V G2R-2-SNDI(S), built-in diode for surge suppression |
| Trânsito Ferroviário | Auxiliary vehicle system, porta & air conditioning control | DC24V G2R-1-SNDI(S), shock resistance, easy maintenance test |
7.2 Case Analysis
Case Title: PLC Control Circuit Test Optimization for Auto Parts Production Line
Demanda: Frequent fault inspection; traditional powered test is inefficient and risky
Seleção: G2R-2-SNDI DC24 (S) + P2RF-08-PU Push-In Plus Socket
Efeito:
- Lockable test button realizes manual actuation without power, 30% efficiency improved
- LED duplo & mechanical indicator reduces misjudgment
- Built-in diode suppresses back EMF and protects PLC modules
- Push-In Plus socket cuts wiring time by 60% and lowers installation cost
- Nameplate marking facilitates circuit management
- Regras de seleção & Resumo
Dicas de seleção
- Choose poles by load: 1-pole 10A for heavy load, 2-pole 5A for dual circuit
- Identify functions by suffix: Integrated LED, diode and test button; (S) with mechanical indicator
- Confirm voltage: No AC-DC interchange, pay attention to DC polarity
- Match P2RF socket series to save wiring labor
- Lockable test button enables offline circuit inspection
Principais vantagens
All-in-one design with complete indicators and test functions
Easy installation and remarkable wiring efficiency improvement
Convenient offline fault diagnosis
Effective surge protection prolongs service life
Eco-friendly wide temperature range from -40°C to +70°C
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares