Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Disjuntor miniatura Schneider C65N-DC/2P-C6A DC - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

Disjuntor miniatura Schneider C65N-DC/2P-C6A DC

ParâmetroValueDescription
Número do pólo2PTwo-pole design, protecting both the positive and negative poles of the circuit simultaneously
Corrente nominal6UMMaximum current for normal operation
Tripping CharacteristicTipo CStandard tripping curve with an instantaneous tripping range of 8.5In 20%
Tensão nominal125V DCSuitable for 125V DC systems
Quebrando Capacidade6oMaximum short-circuit current that can be safely interrupted at 125V DC
Mounting MethodDIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

  • Detalhes do produto

C65N-DC/2P-C6A is a disjuntor miniatura specifically designed for DC systems by Schneider Electric (Acti9 series). The detailed parameters are as follows:

ParâmetroValueDescription
Número do pólo2PTwo-pole design, protecting both the positive and negative poles of the circuit simultaneously
Corrente nominal6UMMaximum current for normal operation
Tripping CharacteristicTipo CStandard tripping curve with an instantaneous tripping range of 8.5In 20%
Tensão nominal125V DCSuitable for 125V DC systems
Quebrando Capacidade6oMaximum short-circuit current that can be safely interrupted at 125V DC
Mounting MethodDIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

Working Principle & Características

The C65N-DC series is a circuit breaker dedicated to DC systems, featuring the following characteristics:

  1. Arc Extinguishing System: Equipped with a special arc extinguishing device designed specifically for DC circuits, effectively quenching DC arcs (DC arcs are more difficult to extinguish than AC arcs).
  2. Características de disparo:

Type C Curve: Suitable for protection of general loads and distribution lines, with an instantaneous tripping current of approximately 51A (8.5×6A).

Thermal-Magnetic Tripping: Integrates dual protection functions of overload protection (thermal protection) and short-circuit protection (magnetic protection).

  1. Structural Features:

Compact design with a depth of only 68mm, saving installation space.

Mechanical service life of up to 20,000 operações, ensuring high reliability.

Protection class IP20 (for the unit itself) / IP40 (when installed in distribution boxes), providing dust and electric shock protection.

Cenários de aplicação

This circuit breaker is suitable for various DC power supply systems:

Automação Industrial: DC motor control, PLC control systems.

New Energy Sector: Solar inverter output protection, energy storage systems.

Communication Equipment: DC-powered devices such as base stations and switches.

Rail Transit: Vehicle auxiliary power supply systems.

Marine Electrical Systems: DC distribution systems.

Typical Application: Protecting DC loads below 6A, such as sensors, small controllers, módulos de comunicação, etc..

Selection & Usage Notes

  1. Correspondência de tensão: Must be used with 125V DC systems; not applicable for AC systems.
  2. Current Selection:

The rated current (6UM) should be greater than the maximum operating current of the circuit.

Consider load starting current: Type C curve allows short-term overloads (por exemplo, motor startup).

  1. Pole Number Selection: The 2P structure disconnects both positive and negative poles simultaneously, providing safer circuit isolation.

C65N-DC/2P-C6A is a compact protection device developed by Schneider for DC systems. Integrating overload protection, proteção contra curto-circuito, and circuit control functions, it is particularly suitable for protecting loads below 6A in 125V DC systems.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado