LS ELÉTRICO ABE404B-4P-400A MCCB - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 LS ELÉTRICO ABE404B-4P-400A MCCB - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

LS ELÉTRICO ABE404B-4P-400A MCCB

  Model Part Meaning ABE Series code, Meta-MEC economy MCCB, viagem termomagnética, low breaking capacity (economy type) 40 Frame rating current 400A 4 4 postes (4P), suitable for three-phase four-wire system protection B Breaking capacity class B (10kA@AC380V) 400A Rated operational current 400A, set by plug module Key Technical Parameters Item Specification Description Product Type ...

  • Detalhes do produto

 

Peça do modeloSignificado
ABECódigo da série, Meta-MEC economy MCCB, viagem termomagnética, low breaking capacity (economy type)
40Frame rating current 400A
44 postes (4P), suitable for three-phase four-wire system protection
BBreaking capacity class B (10kA@AC380V)
400UMRated operational current 400A, set by plug module
  1. Principais parâmetros técnicos
ItemEspecificaçãoDescrição
Tipo de produtoEconomia Disjuntor em caixa moldada (MCCB)Viagem termomagnética, fixed mount
Tensão nominalAC 600V, Ui 690VEm conformidade com IEC 60947-2
Frequência nominal50/60HzUniversal frequency range
Quebrando CapacidadeIcu=10kA@AC380VClass B economy breaking capacity
Tipo de viagemFixed thermal-magnetic tripProteção contra sobrecarga (tempo inverso) + proteção contra curto-circuito (instantâneo)
Tensão nominal de isolamentoUi=690VMaximum voltage for insulation performance
Mechanical Endurance8500 operaçõesStandard operating cycles
Resistência Elétrica1000 operaçõesOperating cycles at rated current
Tipo de montagemTipo fixoStandard 35mm DIN rail or panel mount
ConexãoConexão frontal / Conexão traseiraOptional for different installations
Applicable StandardsCEI 60947-1/2, EM 60947-1/2International electrical standards
  1. Series Model List (400AF Frame)
ModeloPolonesesQuebrando CapacidadeFaixa atual nominal
ABE402b2P10o250UM, 300UM, 350UM, 400UM
ABE403b3P10o250UM, 300UM, 350UM, 400UM
ABE404b4P10o250UM, 300UM, 350UM, 400UM
ABS402b2P25o250UM, 300UM, 350UM, 400UM
ABS403b3P25o250UM, 300UM, 350UM, 400UM
ABS404b4P25o250UM, 300UM, 350UM, 400UM
ABH402b2P35o250UM, 300UM, 350UM, 400UM
ABH403b3P35o250UM, 300UM, 350UM, 400UM
ABH404b4P35o250UM, 300UM, 350UM, 400UM
  1. Recommended International Brand Replacements
MarcaSérieModelo de substituiçãoPrincipais parâmetros de correspondência
SchneiderEZD SeriesEZD400E44004P, 400UM, 10o, viagem termomagnética
Siemens3VT Series3VT8440-1AA034P, 400UM, 10o, viagem termomagnética
ABBTmax SeriesT2N400 TMD 400/400 FF 4P4P, 400UM, 10o, viagem termomagnética
EatonPower DefenseLZMN4-A400-I4P, 400UM, 10o, viagem termomagnética
Interruptor ChangshuCM3 SeriesCM3-400M/4300B 400A4P, 400UM, 10o, viagem termomagnética
  1. Aplicativos & Notas de seleção
  2. Aplicações Típicas

End protection in low-voltage distribution systems, por exemplo, lighting and power distribution in commercial buildings and industrial plants

Three-phase asynchronous motor protection (≤200kW, 380V)

Proteção de banco de capacitores

Small generator outlet protection

  1. Diretrizes de seleção

Confirm system voltage (≤600V) and frequency (50/60Hz)

Calculate circuit rated current to ensure 400A meets long‑term operation

Evaluate short-circuit level: if >10o, use higher breaking capacity ABS (25o) or ABH (35o) série

Consider pole requirement: 4P for neutral protection applications

Confirm mounting (fixed/drawout) and connection direction (front/rear)

  1. Recursos do produto & Vantagens
  2. Econômico & Practical: ABE series is cost-effective for budget‑limited projects
  3. Standard Design: Complies with IEC standards, interchangeable with other brands
  4. Reliable Protection: Thermal-magnetic trip provides basic overload and short-circuit protection
  5. Instalação flexível: Supports front/rear wiring and multiple mounting methods
  6. Complete Accessories: Can be equipped with auxiliary contacts, contatos de alarme, liberação de subtensão, etc..
  7. Manutenção & Solução de problemas
  8. Inspeção Regular: Inspect appearance and tighten terminals quarterly to avoid looseness or overheating
  9. Trip Test: Perform manual trip test annually to verify mechanical reliability
  10. Solução de problemas:

Frequent overload tripping: Check load or replace with higher rated model

Short-circuit tripping: Locate and repair short circuit before closing

Falha ao fechar: Check mechanical jam or replace damaged parts

LS ELECTRIC ABE404B-4P-400A is an economy 4-pole MCCB with 400A rated current and 10kA breaking capacity, suitable for low-voltage distribution systems with moderate breaking requirements. Para maior capacidade de interrupção, use ABS (25o) or ABH (35o) série.

Applications of LS ELECTRIC ABE404B-4P-400A MCCB

Posicionamento central:

This 4-pole economy MCCB (4P, 400UM, 10o) is mainly used for end protection in low‑voltage distribution systems, especially where neutral protection is required, short-circuit current ≤10kA, and budget is limited.

  1. Commercial Building Distribution
AplicativoSuitabilitySelection Tip
Main distribution board main breaker4P protects 3-phase 4-wire; 400A fits small‑to‑medium commercial buildingsTotal load ≤320A (80% duty), short-circuit ≤10kA
Main A/C protection400A for large central A/C units (≤200kW, 380V)Match compressor inrush; recommend undervoltage release
Emergency lighting4P ensures neutral continuity for reliable emergency operationUse with EPS/UPS; front connection for easy maintenance
Elevator room power400A for multiple elevators; 4P prevents neutral faultsInstall in dedicated cabinet; ensure ventilation

Casos Típicos:

3–5 story office buildings, chain supermarkets, hotels as main or important branch breaker.

  1. Industrial Plant Applications
  2. General Machinery

Main breaker for small‑medium production lines: 400A covers multiple branches; 10kA suits general industrial short-circuit levels

Motor group protection: Total power ≤200kW, used with thermal relays for precise protection

Auxiliary equipment: Fãs, bombas, compressores; 4P for control circuits with neutral

  1. Specific Industries

Food processing: Cost-effective for light industry; 4P ensures safety and quality

Electronic assembly: 400A for multiple lines; 4P avoids neutral drift affecting precision equipment

Warehouse power: Main breaker for lighting and forklift charging

Aviso:

If short-circuit current >10o, upgrade to LS ABS (25o) or ABH (35o).

  1. Public & Edifícios Residenciais
  2. Education & Medical

School main distribution: 4P protects lighting, Ar condicionado, computer rooms; 400A for whole building

Community hospital: 4P for medical equipment with neutral; economy for primary care

Stadium auxiliary systems: Iluminação, audio, seats; 400A for local zones

  1. Infrastructure

Small wastewater treatment: 400A for pumps and blowers; 4P prevents control system failure

Urban landscape lighting: Main breaker for multi-loop lighting with reliable neutral

Small waste transfer station: 400A for compressors and conveyors; low operating cost

  1. Special Applications
  2. Capacitor Bank Protection

For capacitor banks ≤100kvar; 4P prevents inrush and short-circuit during switching

Recommend adding SPD for surge protection

  1. Small Generator Systems

Main breaker for generators ≤300kVA; 4P ensures safe isolation from grid

Used with synchronizing equipment for smooth switch between mains and generator

  1. Temporary Power

Construction site temporary power main breaker; 400A for cranes, welders

4P suitable for harsh site conditions; prevents electric shock from broken neutral

  1. Seleção de chave & Application Criteria
FactorRecomendadoNot Suitable For
Short-circuit level≤10kA: adequado; >10o: use ABS/ABHHigh-risk areas (químico, mineração) com >10o
Load typeResistive & cargas indutivas (iluminação, motores)Large rectifiers, arc furnaces, high nonlinear loads
Earthing systemTN-S, Sistemas TT (4P neutral protection)IT systems (operating rooms, minas)
AmbienteIndoor dry, ≤40°COutdoor, damp, explosive areas (needs special enclosure)
Operation frequencyOperação pouco frequente (≤12/day)Frequent duty (guindastes, elevator main circuits)
  1. Application Advantages
  2. Econômico: High cost-performance for budget projects
  3. Full protection: 4P design covers 3-phase + neutral for modern distribution
  4. Conformidade padrão: CEI 60947-2, interchangeable with major brands
  5. Instalação flexível: Front/rear wiring + 35mm trilho DIN
  6. Confiável: Mecânico 8500, elétrica 1000 operações

Best Combination:

Use ABE404B-4P-400A as main breaker + LS MCBs for branch protection to form a reliable two‑stage system.

For higher performance or electronic protection, upgrade to ABS (25o), ABH (35o), or ABN (viagem eletrônica) série.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado